How to control RH (Relative Humidity) by AHU | HVAC System | HVAC World

Sdílet
Vložit
  • čas přidán 20. 08. 2024
  • Hell guys!!
    HVAC se related choti SE choti problem ki video ham bana KR upload krte rhte jisse apko HVAC ki knowledge milti rahe
    so plz
    LIKE | COMMENT | SHARE | SUBS C R I B E
    Keep Sharing - And Subscribe For More Updates...
    THANK YOU.

Komentáře • 228

  • @HVACWorld
    @HVACWorld  Před 4 měsíci +1

    www.hvacwworld.in/
    Visit our official website 😊😊

  • @arsalanbaig9196
    @arsalanbaig9196 Před 4 lety +9

    Probably the most amazing and detail video on this topic (Hindi) on CZcams...... I believe. Thank you so much.

  • @aashirathorenagour694
    @aashirathorenagour694 Před 2 lety +1

    Best vedio on HVAC tooic, in hindi language on you tube, grate👍👍🙏🙏🤟

  • @zubaitkhan2404
    @zubaitkhan2404 Před rokem +1

    Very very informative, so nicely explained, the most confusing topic in HVAC . Thanks dear.

  • @hiteshtawate1921
    @hiteshtawate1921 Před 16 dny +1

    nice information...

  • @deepraja
    @deepraja Před 2 lety +1

    A Job well done. All the comments below are the proof. Keep it up. Thanks

  • @basilkaskar1212
    @basilkaskar1212 Před 3 lety +4

    I wish to give hundred likes, very well explained on this topic. 👍

  • @hirazareen2598
    @hirazareen2598 Před 2 lety +1

    Best of the best video... The way u explained it is mind blowing

  • @AbhishekTripathi412
    @AbhishekTripathi412 Před 3 lety +2

    Very nice... Explained technically to the point... Awesome Sir

  • @shortworld8599
    @shortworld8599 Před 2 lety +2

    Thanks sirji
    This is very helpful for me 👍👍👍👍

  • @syedahsanbukhari4400
    @syedahsanbukhari4400 Před 3 lety +2

    Boss you have lot of knowledge

  • @usmankhalid2954
    @usmankhalid2954 Před 3 lety +5

    Best Regards from Pakistan Sir please explain about low delta T syndrome in detail. want to clear my concept from you so kindly make another video of this.
    Stay blessed

  • @rbr_96
    @rbr_96 Před rokem

    Thank you so much for the Beautiful Explanation.

  • @amirsohail2010
    @amirsohail2010 Před 3 měsíci +1

    very useful and informative video

  • @ajeetkumarguptahvac3017
    @ajeetkumarguptahvac3017 Před 3 lety +2

    Bahut achha anlayses kiye sir ji
    Ahu ,rh, d-humidification humidification, cooling d- humidification ,
    Sir ap ase hi psycrometric ko bataye

  • @starindia7042
    @starindia7042 Před 2 lety

    thnq sir, clean and good explain finally i understand
    thnx ❤

  • @akashbadgujar3339
    @akashbadgujar3339 Před 2 lety +1

    Very useful information sir

  • @vinodpatel-qw2yj
    @vinodpatel-qw2yj Před rokem

    Good job & good experience in HV/AC

  • @girijanayak8814
    @girijanayak8814 Před 3 lety +1

    Thanks Sir for explaining with clarity, an excellent initiative 👍👍👍👏

  • @mo.mubashshir3400
    @mo.mubashshir3400 Před 8 měsíci +1

    Nice explain
    Thank u

  • @idz4998
    @idz4998 Před 2 lety

    Hello Sir, very well explained in simple way. I will share this video with my Juniors so that they get the point. Thank You.

  • @ajecindia9659
    @ajecindia9659 Před 10 měsíci

    very nicely explanation keep it up. thank you.

  • @sultansalahudheen3530
    @sultansalahudheen3530 Před 11 měsíci +1

    Hello brother,
    Very good explanation and clarify nicely. I will contact directly I have some doubts in HVAC. Bcz your explanation is very good. Thanks a lot and keep it up.

    • @HVACWorld
      @HVACWorld  Před 11 měsíci

      Plz contact me on 8130349987

  • @hadishansari5974
    @hadishansari5974 Před 3 měsíci +1

    Too good explain

  • @yaseeysyed3009
    @yaseeysyed3009 Před 2 lety

    Superb technical explanation, very good effort

  • @ssraorao7565
    @ssraorao7565 Před 3 lety +1

    Excellent explation thank sir👏🙏

  • @adventure_man6739
    @adventure_man6739 Před 2 lety +1

    Most Amazing video

  • @satyamprajapati9064
    @satyamprajapati9064 Před 3 lety +1

    Very nice explain

  • @nagendrakunchala8985
    @nagendrakunchala8985 Před rokem +1

    Excellent Presentation

  • @tariqueraja8773
    @tariqueraja8773 Před měsícem +1

    Thanks ❤❤

  • @mdsaddamhussain9465
    @mdsaddamhussain9465 Před 2 lety +2

    Sir please upload videos on documents used in MEP and also how to prepare Time sheet. And Daily progress report

  • @sunilkumar4126
    @sunilkumar4126 Před 3 lety +1

    Nice video

  • @robingupta1645
    @robingupta1645 Před rokem

    Very informative video

  • @sajidazhar2456
    @sajidazhar2456 Před 2 měsíci

    Good explanation.🤝 Please make video how to work supply air Statics pressure.

  • @rawooframzan3358
    @rawooframzan3358 Před 3 lety

    Bht ache bhai...nice explain ...jazakallah bhai

  • @MDAmir-vb9rm
    @MDAmir-vb9rm Před 2 lety +1

    very good

  • @GufranAnsari-qy5nq
    @GufranAnsari-qy5nq Před 3 měsíci

    Good job good information

  • @wahabkazmi4254
    @wahabkazmi4254 Před 3 lety +1

    Excellent explanation . 👍

  • @usmankhalid2954
    @usmankhalid2954 Před 3 lety

    Sir how we treat our waste air and fresh air in FAHU and how FAHU supplies fresh air to every AHU of building floors. So kindly explain. Thanks a lot A lot of love.

  • @fahadraja218
    @fahadraja218 Před 3 lety

    Bahut badhia

  • @manoharlal9495
    @manoharlal9495 Před 3 lety

    Very Exalant Sir open type compressor me pump down kaise karte hai Sir

  • @joydipghosh3273
    @joydipghosh3273 Před 2 lety

    Thanks for your video... please share a video of calculation of humidifier & reheat coil with task...

  • @sanjaymavani1882
    @sanjaymavani1882 Před 2 lety +1

    Nice

  • @shahidansari9139
    @shahidansari9139 Před 2 lety

    Thanks alot for your valuable knowledge. It helped me to understand the concept of relative humidity. Request you to please make video on material estimation such as copper piping,duct sheet,insulation etc.

  • @dubai611
    @dubai611 Před měsícem +1

    🙏🙏🙏🙏

  • @nareshshirsath4436
    @nareshshirsath4436 Před 4 lety +1

    Very nice video sir

  • @anutoshdutta3178
    @anutoshdutta3178 Před rokem

    Excellent Explaination. Thank you so much. But where do I have to install Rh Sensor and Temperature Sensor to control it by a PLC based panel?

  • @anubhavsingh5853
    @anubhavsingh5853 Před 7 měsíci +1

    Great content

  • @bujjamma6669
    @bujjamma6669 Před 2 lety

    Excellent explanation sir

  • @syedbasheer2299
    @syedbasheer2299 Před 9 měsíci

    👍👍👍

  • @jawadkhan4178
    @jawadkhan4178 Před 3 měsíci

    Really appreciate ❤

  • @omprakashyadav2055
    @omprakashyadav2055 Před 3 lety +1

    मजा आ गया महाशय

  • @Reelsworld228
    @Reelsworld228 Před 3 lety

    Very good explanation

  • @anthonysalve4023
    @anthonysalve4023 Před rokem

    1. Please/show explain this heating & humidification in AHU. 2. Cooling & dehumidication on psychromatic chart.

  • @waquarahmad8601
    @waquarahmad8601 Před rokem

    First of all you are doing great job!!
    We appreciate your greater efforts.
    My question is below.
    How do we decide or calculate the quantity of steam or water to be added to the AHU to achieve the desired humidity level in the space?
    Can you please elaborate in the next video.
    Or anyone there who can explain this?
    Thank you in advance!

    • @bilalpurpraveenkumar8257
      @bilalpurpraveenkumar8257 Před rokem

      By measuring the Return Air temperature and supply (cooling coil) air temperature of the AHU we measure that

  • @user-du2kr3fu7h
    @user-du2kr3fu7h Před 5 měsíci +2

    When it is warmer outside, the air holds more water vapour, and when it is cooler outside, the air does not retain as much water vapour. This explains why summers are hot and humid, while winters are frigid and dry. Therefore, the summer season has more humidity than other seasons. don't share wrong information.

  • @abbasmaskati5339
    @abbasmaskati5339 Před rokem

    Nice very informative
    Sir can you please make video on design of hospital operation theater

  • @irshankhan7158
    @irshankhan7158 Před 3 lety +1

    perfect sir..! 🔥❤️

  • @yashavantkesare4417
    @yashavantkesare4417 Před 3 lety

    Great explanation

  • @Mullli713
    @Mullli713 Před 2 lety

    Excellent

  • @akhilihka
    @akhilihka Před 3 lety

    very well done

  • @syedahsanbukhari4400
    @syedahsanbukhari4400 Před 3 lety

    Awesome lecture

  • @sachinkp4504
    @sachinkp4504 Před 3 lety

    Well explained sir

  • @rituthakur307
    @rituthakur307 Před 4 lety +7

    I have doubt if we remove moisture/water by cooling coil.. then why RH increase, as u said rh means amount of water vapour in air...

    • @HVACWorld
      @HVACWorld  Před 4 lety

      Moisture is continuously adding in environment.. because everyone second water vapourisatiin takes place....our body also relases water from our body...and light and computer these are the elemt of latent heat which continuously adding moisture..... because of these every time RH increases which have to put down up to human comfort

    • @Shamiyusif
      @Shamiyusif Před 4 lety +1

      HVAC World computer and light can add only sensible heat not latent heat .

    • @kantmarch1
      @kantmarch1 Před 3 lety +1

      You are saying right. He seems to tell wrong

    • @aymankhan9001
      @aymankhan9001 Před 3 lety

      First of all understand dbt wbt ....latent heat .humidiity..
      How much water present in air then is also called relative humidity rh...
      Dbt and wbt measure by psycrometer...there rr two therometer installed in one equipment system...if the relative humidity is more then we fell uncomfortable why......because due to present of water to more in our surrounding

    • @Nilesh_Shinde23
      @Nilesh_Shinde23 Před rokem

      Right

  • @nimishsingh172
    @nimishsingh172 Před 3 lety

    sir aap mahaan hai

  • @user-hw5kn4gl4k
    @user-hw5kn4gl4k Před 8 měsíci +1

    thanks sir for this video , can RH control possible by ductable units

    • @HVACWorld
      @HVACWorld  Před 7 měsíci

      Yes it is possible up to certain limit

  • @user-ky5ub5yc5e
    @user-ky5ub5yc5e Před rokem

    Thaku

  • @subhadipmohapatra9197
    @subhadipmohapatra9197 Před 4 lety +2

    Hi Sir,
    Excellent Explaination. Thank you so much. Can you explain how to calculate Heater KW ?? I have an application where I need to maintain RH @45%.
    Thanx in advance

  • @bujjamma6669
    @bujjamma6669 Před 3 lety +1

    Professional explained 👌👌👌👌👌👌👌👌👌👌💗

  • @irfankarim8400
    @irfankarim8400 Před 6 měsíci +1

    Hi bro i need your help if we heating coil in AHU can we electric duct heater we can install for the prayer room or kitchen and why

    • @HVACWorld
      @HVACWorld  Před 6 měsíci

      Can you please clarify your question. Sorry I didn't get that

  • @mohammedkarim4790
    @mohammedkarim4790 Před 3 lety

    FAHU york ka hai aur labs me use hota hai jiska return air atmosphere me exhaust karte hai reuse nahi karte

  • @funnymemers3232
    @funnymemers3232 Před 3 lety

    Mast video h sir

  • @ershaikhfahad2816
    @ershaikhfahad2816 Před 2 lety +1

    Sir in sea side luxury hotel here ahu has 4 coil inlet and 4 coil outlet system means 2 chilled water inlet and 2 chilled water outlet and and remaining coils has normal water circulation in closed loop why this is provide after the cooling coil is this the Same dehumidification control via reheat system

    • @HVACWorld
      @HVACWorld  Před 2 lety

      Because high humidity near sea area.....coil has to remove moisture from air....and balanced coil having normal or hot water circulation is provided to main RH in air conditioning area.
      Because high level of humidity can not be maintained by dehumidication and cooling. There should be reheat process

  • @abdulkidwai5945
    @abdulkidwai5945 Před 3 lety +1

    Sir plz make video on manual calculation

  • @MandeepSingh-el6un
    @MandeepSingh-el6un Před 3 lety

    Sir plz make video on "calculation of HWG capacity for maintaining RH in OT"
    AND "calculation of HWG capacity for winter heating in existing Chiller circuit"

  • @ATIFKHAN-mz4fp
    @ATIFKHAN-mz4fp Před 4 lety +1

    Good morning sir for year around air conditioning system we apply all above process to control RH

  • @sohailqureshi503
    @sohailqureshi503 Před rokem

    Salam sir h r u sir hmare pass airwash system h usme Sirf water spray k sath air follow hti h duck m to RH control nai hri wese pora saal ase hi chlta h system RH kbi 45 kbi 55 show krta

  • @irfankarim8400
    @irfankarim8400 Před 6 měsíci +1

    If ahu have heating coil and in duct we can install electric duct heater
    Is it possible ?

    • @HVACWorld
      @HVACWorld  Před 6 měsíci

      Yes you can but If AHU has heating coil only why you need to add extra heating source . You can install heater in duct when you have cooling coil

  • @rockypundir2278
    @rockypundir2278 Před 2 měsíci +1

    Bhai apnea concept m today confuse Kar diya Hai, agar wer bulb and dry bulb k bech ka diffence Jada h toh humidity down hogi ya increase hogi ?

    • @HVACWorld
      @HVACWorld  Před 2 měsíci

      RH decrease hogi.... Humidity constant rahega until unless moisture add na ho.

  • @moonshiekh1100
    @moonshiekh1100 Před 3 lety +1

    Bhai ek baat samjh nhj ayi mujhe summer me toh temp jayda hita h Humility jayda hoti h which means ki water vapor jayda h air me isliye garmiyon me chip chipa paseena feel hota h humidity jayda hoti h just opposite in winner me humidity water vapor kam hota h isliye winter me hamri skin dry hota h
    But chat me just opposite show kar rha h garmi me kam nd winter me jayda dekga rha h
    Samjh nhi aya ye kya chakkar h ???

    • @HVACWorld
      @HVACWorld  Před 3 lety

      Bhai summer me humidity kam hoti h

  • @siddheshparab8302
    @siddheshparab8302 Před 3 lety +2

    Lekin summer mein 20% RH hain, aur cooling & dehumidification ke baad toh RH aur kam hona chahiye ?

    • @moonsheikh7117
      @moonsheikh7117 Před 2 lety +1

      Are 44 dbt
      Wbt 23
      Gap jayda h isliye rh 20% kam h
      Summer me cooling krenge
      Jab cool hoga 44 se ye 24 ke pass pass aywga means dbt wbt me gap kam ho gya automatically RH 20 se 50 t0 60 phunch jayega
      Samjh gya logic
      Gap jayda toh rh kam
      Gap kam toh rh jayda
      Iss logic se samjho

  • @virendrapanwar312
    @virendrapanwar312 Před rokem

    Sir data dijiye kitne CFM mai kitne kw ka heater lagaye aur pan humidifier kitne capacity ka lagaye

  • @mohdarman8149
    @mohdarman8149 Před 18 dny

    Pressure relief valves kiya kaam hai HVAC me kahan fiting hote hai

  • @rajeevsrivastava2940
    @rajeevsrivastava2940 Před rokem

    I am facing rh issues in our clean room .
    Not achieved rh

  • @vikashkumarpandey8317
    @vikashkumarpandey8317 Před 2 lety +1

    Please review your RH value for winter and summer.

  • @subhashishbhattacharjee4993

    Sir dry bulb aur wet bulb k liye koi video banaya hai kya?

  • @shabbirali4580
    @shabbirali4580 Před rokem +1

    Is every AHU have enbuild humidifier or dehumidifier.
    In winter we don't need humidifier to control RH, but if it's there in AHU, how to stop humidifier to work in winter.

    • @HVACWorld
      @HVACWorld  Před rokem

      AHU is also known as dehumidifier....AHU doesn't have inbuilt humidifier. We have to provide humidifier based on requirements or design

  • @shabazkhan282
    @shabazkhan282 Před 3 lety

    Sir ahu ki wairing kaise karte hai usper video banaiye please

  • @asifjutt8824
    @asifjutt8824 Před 4 lety +1

    👍

  • @nehal3749
    @nehal3749 Před 6 měsíci +1

    11:42 agar de humidification hogaya to after coil rh kaise increase hoga aur humidity kaise increase hojayega??

    • @HVACWorld
      @HVACWorld  Před 6 měsíci

      Actually jab air cooling coil se cooled hoti h to uska temperature saturation temperature k pass laya jata h or aap psychometric chart pe dekhoge k saturation line pe air ki RH 100% hoti h... Saturation curve pe air ko lane se hi wo dew point ki trf jati h or jisse k Condensation hota h or air dehumidifie hoti h
      ...jaise hi coil se aage air nikalti h wo room se heat leti h jisse ke uska RH kam ho jata h ...is trh se RH maintain hoti h cooling and dehumidification k case me

  • @jamsheerali7229
    @jamsheerali7229 Před rokem

    Steam type built in humidifier, is control both humidification and de humidification ?

  • @irfankarim8400
    @irfankarim8400 Před 6 měsíci +1

    I have both cooling coil & heating coil in ahu and humidifer
    Can we add electric heater in duct
    Tell me

    • @HVACWorld
      @HVACWorld  Před 6 měsíci

      If your Heating coil se sufficient to maintain the RH inside the room then it is not required to add heater in duct...if you want only heating inside room in winter season and your heating coil capacity is not designed for heating then you can add heater inside duct and use both coil and heater for comfortable heating inside the room...make sure your CHW supply should of in OFF condition

    • @irfankarim8400
      @irfankarim8400 Před 6 měsíci

      Thank you

  • @arunkumar-yl6yt
    @arunkumar-yl6yt Před 2 lety +1

    How will the control system for rh control work

  • @bhivajibargaje4290
    @bhivajibargaje4290 Před rokem +1

    I have installed Humidifier and dehumidifier at my company....now days I am not able to increase the humidity... please

    • @HVACWorld
      @HVACWorld  Před rokem

      Plz check working of humidifier

  • @abhinandansharma3126
    @abhinandansharma3126 Před 4 měsíci

    How to calculate quantity of moisture removal

  • @mahmoodsabbir4561
    @mahmoodsabbir4561 Před 2 lety +2

    u said in summer RH is low..is it okay?? i thhink u said wrong

    • @mahmoodsabbir4561
      @mahmoodsabbir4561 Před 2 lety +1

      u said we use moisture in summer!!!! how funny

    • @HVACWorld
      @HVACWorld  Před 2 lety

      Will answer you by making video deticated for your questions

  • @ramsinghtomar7943
    @ramsinghtomar7943 Před rokem

    Hello Sir please tell us about heater selection how to calculate heater kw

  • @BittuSingh-rw1kr
    @BittuSingh-rw1kr Před 2 lety +1

    Moisture to condense ho gya hai cooling coil ke pass, phirr room me 90% moisture kaise rahegi

    • @HVACWorld
      @HVACWorld  Před 2 lety

      Room me nahi rhegi.... supply air pe rhti h...kyu k coil DBT ko WBT k near about kar deta h

  • @shihasvkd
    @shihasvkd Před 4 lety +1

    Can you please make videos in English ?

  • @Videshi_vlog
    @Videshi_vlog Před 3 lety +2

    Sir meko kaam karna hai aapke saath🙁 mai bhi delhi se hi hu i want an opportunity to learn from you

    • @HVACWorld
      @HVACWorld  Před 3 lety +1

      Av kaha job kr rhe ho???...mai employee hun company me...koi vaccancy aai to zarur inform krunga...apna resume send kr do ayanbabu133@gmail.com pe

    • @DeepakKumar-lx8vl
      @DeepakKumar-lx8vl Před 3 lety

      Hi I m sailing air filters pls contact 8586885884