AHU drain water over flow problem with solution | HVAC Training video | HVAC World

Sdílet
Vložit
  • čas přidán 20. 08. 2024
  • Hell guys!!
    HVAC se related choti SE choti problem ki video ham bana KR upload krte rhte jisse apko HVAC ki knowledge milti rahe
    so plz
    LIKE | COMMENT | SHARE | SUBS C R I B E
    Keep Sharing - And Subscribe For More Updates...
    If you are having any problem at site plz send video on ayanbabu133@gmail.com
    we will come out to you with suitable solution
    THANK YOU.

Komentáře • 104

  • @subhash6433
    @subhash6433 Před rokem +1

    Sir thank u...sahi me bhi ye problem face kar raha hu. Abhi try karta hu

  • @yashavantkesare4417
    @yashavantkesare4417 Před 3 lety

    We also have same problem nd luckily i get ur video

  • @ttrenterprisesonline6399
    @ttrenterprisesonline6399 Před 2 lety +2

    Right now good quality sir

  • @mohdhalimquraishi1364
    @mohdhalimquraishi1364 Před 3 lety +1

    Best video sir thank you so much

  • @janibashamolla
    @janibashamolla Před rokem +1

    Exlent explanation sir ji

  • @mdaafanhasan2651
    @mdaafanhasan2651 Před 4 lety +1

    You explained very well

  • @satyamprajapati9064
    @satyamprajapati9064 Před 3 lety +1

    Nice explain

  • @spgelectrical8797
    @spgelectrical8797 Před rokem +2

    Filter bhi shi hai u trap bhi shi hai fir bhi blower pani khich leta hai

    • @HVACWorld
      @HVACWorld  Před rokem +1

      Zyada static ka AHU hoga....iske liye double U trap bnana hoga..

    • @m4team825
      @m4team825 Před 2 měsíci +1

      drain se pani kench raha​@@HVACWorld

    • @HVACWorld
      @HVACWorld  Před 2 měsíci

      @@m4team825 U trap ko AHU supplier k design k according banwao

  • @birdsandnature8891
    @birdsandnature8891 Před 2 lety +1

    Excellent

  • @Panghal2017
    @Panghal2017 Před 3 lety +1

    Nice explanation

  • @abdulgaffoorriyazahmed7215

    Thanks

  • @RashidKhan-lr4fh
    @RashidKhan-lr4fh Před 3 lety +1

    Great thanks

  • @fjiddimanijiddimani1663

    Best explanation

  • @moideenyousaf3757
    @moideenyousaf3757 Před 3 lety +1

    also, the coil face velocity to be limited. the water shall be carried over when the face velocity go above 500 fpm

  • @shailendrapal5157
    @shailendrapal5157 Před 4 lety +2

    Agar AHU CFM jyada ho to bhi blower water Apni Taraf khinchta Hai or AHU ki CFM Pully size glt hone se jyada CFM Dene lgta hai

    • @HVACWorld
      @HVACWorld  Před 4 lety

      Exactly...good observation...

  • @nareshkumar9218
    @nareshkumar9218 Před 3 lety +1

    Best video

  • @sarojkumargouda3730
    @sarojkumargouda3730 Před 3 lety +1

    Thanks you sir for sharing the information

  • @hintertainment258
    @hintertainment258 Před 2 měsíci

    Drain bhee clear hai filter bhee clean hai fir bhee water leakage aarahi hai

  • @taiyabansari5905
    @taiyabansari5905 Před 4 lety +1

    Nice video sir ji

  • @mohammedkirmanisyed7960

    Awesome...Explanation. ..

  • @mohsinsayyad4143
    @mohsinsayyad4143 Před 2 lety

    Haa sahi kaha sir

  • @nagunagaraj5103
    @nagunagaraj5103 Před 4 lety

    Super super super explained 👏👏👏👏

    • @nagunagaraj5103
      @nagunagaraj5103 Před 4 lety +1

      FAHU also same solution? Please reply

    • @HVACWorld
      @HVACWorld  Před 4 lety +1

      Yes almost same solution....if you have any issues you can share with us with video we will provide exact solutions

  • @nafisahmad001
    @nafisahmad001 Před 7 měsíci +1

    G sir ye issue hamare project pe v hai

  • @drymindfitnessclub3848
    @drymindfitnessclub3848 Před 10 měsíci

    Same problem h FAHU some time water leak in fahu duct

  • @shaikjuned712
    @shaikjuned712 Před 3 lety

    Thnq bhai

  • @raheeztp3158
    @raheeztp3158 Před 2 lety +1

    👍👍👍👍👍👍

  • @blaisefernandes
    @blaisefernandes Před rokem

    What if we use water pump to pump water after it reaches flood switch.even split until are using drain pump y u traps

  • @GovindSingh-wp7qi
    @GovindSingh-wp7qi Před 3 lety

    Nyc bro

  • @smsha6824
    @smsha6824 Před rokem

    And also if ur are manually opening cooling actuator to 100 % then there will same issue as well as filters coil cleaning

  • @IrfanKhan-ht8bv
    @IrfanKhan-ht8bv Před rokem

    Awesome 👍😎

  • @rezashahid7768
    @rezashahid7768 Před 4 lety

    Thanks so much sir

  • @balajikumbhar6785
    @balajikumbhar6785 Před 2 měsíci +1

    Sir filter our u trap bhi oky hey phir bhi water lecage ho raha hey

  • @chrisshine3953
    @chrisshine3953 Před 4 lety

    Thank you...

  • @Islamkhan-xp5fw
    @Islamkhan-xp5fw Před rokem

    Water suction from drain line while u trap is also good what problem?

  • @Makeapeacefulworld
    @Makeapeacefulworld Před rokem

    Problem exist after this. Any problem with drift elemintors instaaled in AHU

  • @kiransubedi3763
    @kiransubedi3763 Před 7 měsíci +1

    ये सब कर्ने के बाद भी सेम होरहाहे अब केया बजै हो सकता है पिलिज इसका सोलोषण बतादिजिए न सर🙏🙏🙏

    • @HVACWorld
      @HVACWorld  Před 7 měsíci

      Send me videos on ayanbabu133@gmail.com

    • @kiransubedi3763
      @kiransubedi3763 Před 7 měsíci +1

      जेसा इसभिडियो में भराहुवा हे सेम ऐसा ही भ्र जाताहे

  • @dadakhan9084
    @dadakhan9084 Před 2 lety +2

    Assalamu ulaikum bhai ek baat bataw A.H.U ka return garam pani horaha h hamny sab valve chek krli h sabb opan h doosri baat h pani saf aara h aur pani sarkuling to horaha h fir Kia wajah h jo pani ritarn gram h

  • @shashikumarkalledevar8433

    Shall we provide inverted U trap if space is less below the unit..? And same formula applies there too?

  • @ayankhamaru5449
    @ayankhamaru5449 Před 2 lety

    Sir what about the 15TR AHU drain pump discharge rating and drain pump specification.

  • @melvinfarnandis7585
    @melvinfarnandis7585 Před 2 lety +1

    After U trap also coming what is the reason

  • @rjvlog746
    @rjvlog746 Před rokem +1

    BROTHER DRAIN SW AIR KHICHTA HAI FAHU KYA PROBLEM HO SAKTA HAI

    • @HVACWorld
      @HVACWorld  Před rokem

      Static zyada hoga or U trap proper nahi hoga

    • @rjvlog746
      @rjvlog746 Před rokem

      @@HVACWorld pahile wahi sahi tha abhi air khichta hai lekin fahu ke inside drain me patla sa pipe dal diya hai to air band hogya hai lekin uska water bahut slow jata hai

  • @rakeshkaple3025
    @rakeshkaple3025 Před 4 lety +1

    Che line FCU connected hai inlet ka tem 7 deg.hai & outlet ka 20 deg celcius hai kya problem ho sakti hai.

    • @HVACWorld
      @HVACWorld  Před 4 lety +2

      Sare valve open hai ek baar cross check kr lo....sare valve open hai to strainer saaf karwa lo khol kr kachra jam gaya hoga strainer ki jaali me

  • @skhangamingyt2696
    @skhangamingyt2696 Před 3 lety +1

    I am facing Same problem with two FAHU please reply air band is a good solution for this problem or no

    • @HVACWorld
      @HVACWorld  Před 3 lety +1

      Plz check all things which mentioned in video

  • @mohdziauddin7711
    @mohdziauddin7711 Před rokem

    Sir AHU ke vibration ko kaise control karte h????

  • @kumardinesh1990
    @kumardinesh1990 Před 3 lety

    Isko chalu krne samay kya kya on krna para hai Bhaiya

  • @chiragrana2733
    @chiragrana2733 Před rokem

    How to calculate condensate drain water as per ton coil?

  • @jaffarhussain5669
    @jaffarhussain5669 Před 3 lety

    What kind of insulation you talking about. Usually we dont put insulation on drain pipe

  • @midhunthulaseedharan5943

    AHU water inlet and outlet line are show very high pressure. Why?

  • @neerajkumaar4821
    @neerajkumaar4821 Před rokem

    o humye Pattaya hi nahi thq

  • @kashifiqbalzafar
    @kashifiqbalzafar Před 4 lety +1

    hello sir ,
    how are you ?

  • @mrlee2691
    @mrlee2691 Před 2 lety

    Ahu off karne ke bat pani nekal ta he q sir plzz rpy

  • @mohammedkarim4790
    @mohammedkarim4790 Před 3 lety +2

    Sirji in my site more than 50 FAHU having same problem and U trap also ok and after changing new bag filter also water flooding and this problem coming in summer only and our Ahus running onVFD so the speed also varies so can u explain what are the causes except what you explain

    • @HVACWorld
      @HVACWorld  Před 3 lety +1

      All these are limited to channels members....if you have member ship then we will resolve it by what's app chat or call

    • @melvinfarnandis7585
      @melvinfarnandis7585 Před 2 lety +1

      Boss there is entering outside humidity reduce fresh air

    • @nasifmajeed7573
      @nasifmajeed7573 Před 2 lety

      Partially close the Damper to 50 or 60 % Summer time Humidity issues will be high due to this water over flow will be there and and you can feel Dryness while touching the chilled water cooling coil

  • @rakeshkaple3025
    @rakeshkaple3025 Před 4 lety +1

    Hi sir

  • @yogeshkamboj4500
    @yogeshkamboj4500 Před 4 lety +1

    Sir abi bi ho rhi hai problem filter bi clean kr diye

    • @HVACWorld
      @HVACWorld  Před 4 lety +1

      Aap you trap check kro....height kya hai you trap ki. .jaisa maine drawing me btaya hai us method se install hua hai ya nahi

  • @mirzaahmedalibaig9273
    @mirzaahmedalibaig9273 Před 3 lety

    Sir in my ahu statistics pressure 1058 how to calculate c.f.m 13929 pls tell me how find out drain fixed

  • @mohammadshamstabrez2406
    @mohammadshamstabrez2406 Před 4 lety +1

    Sir same problem mer AHU me aa raha he

    • @HVACWorld
      @HVACWorld  Před 4 lety +1

      Jo points maine video me btai hai usko check kro fr btana

  • @AsadKhan-uh2dn
    @AsadKhan-uh2dn Před 3 lety +1

    Assalam alaikum kaise hai bhai mai Pakistan sy hu or ap ki videos buhut knowledgeable hai ap apne WhatsApp number mujhe send kar di jiye

  • @waqasmuzaffar1027
    @waqasmuzaffar1027 Před 4 lety +1

    choke k matlab samajh nhi ayea?

    • @HVACWorld
      @HVACWorld  Před 4 lety +1

      Choke ka matlab jaan ho jana...pipe k andr kisi chiz k fasne se pani bahar nhi ata h to use chokhe bolte hai

    • @waqasmuzaffar1027
      @waqasmuzaffar1027 Před 4 lety

      @@HVACWorld thanks for the reply janab

  • @user-pn1le2mn4t
    @user-pn1le2mn4t Před 2 lety +1

    in english please

  • @mirzaahmedalibaig9273
    @mirzaahmedalibaig9273 Před 3 lety +1

    But sir in my ahu almost same problem but EC motors fixed in supply return air using EC motor EC motor frequency can kept supply is 100% return air kept 60% to 80% in this motors frequency can change one more ahu is big size which the centre of cooling coil one more drain try fixed bottom drain connected centre drain try bottom link but here bottom try water is not drain due air taking from u trap but centre Darin tray water sucking fan motor due to 100% supply ahu motor pls suggest me if you give you whathapp number i can send you photos

    • @HVACWorld
      @HVACWorld  Před 3 lety

      facebook.com/100794634950757/videos/758529181554078/
      This is my fb page we can chat over there...

  • @zahidvlogs277
    @zahidvlogs277 Před rokem

    How to control AHUs ducting water drop?

  • @s4shamsi257
    @s4shamsi257 Před 4 lety +1

    Reply dain ge aap

    • @HVACWorld
      @HVACWorld  Před 4 lety

      Ofcourse...we are here for you guys only

    • @s4shamsi257
      @s4shamsi257 Před 4 lety +1

      Can you help me

    • @HVACWorld
      @HVACWorld  Před 4 lety +1

      Yes I will try my level best.... let me know your problem

    • @s4shamsi257
      @s4shamsi257 Před 4 lety

      @@HVACWorld Bhai Jan Khali like Kare gain Maine aik guzarish ki hai

    • @HVACWorld
      @HVACWorld  Před 4 lety

      Konsi guzarish??