DX Type Fresh Air Handling Unit | DX-FAHU | HVAC in Urdu/Hindi

Sdílet
Vložit
  • čas přidán 20. 08. 2024

Komentáře • 322

  • @TanweerAhmed
    @TanweerAhmed  Před rokem +2

    Treated fresh air handling unit: czcams.com/video/LZ5wk-B4W_k/video.html

  • @technicalhelp9769
    @technicalhelp9769 Před 3 lety +4

    Allah ap k ilam ma or izzfa kary Ameen😍😍

  • @designdraftingservices1950
    @designdraftingservices1950 Před 4 lety +10

    I'm getting a lot knowledge from your valuable videos

    • @TanweerAhmed
      @TanweerAhmed  Před 4 lety

      That's good

    • @nawajali8369
      @nawajali8369 Před 4 lety +1

      Ham ko bhi kam ki talas hai H B A C ka 7292855241 Nawaj Ali

    • @nawajali8369
      @nawajali8369 Před 4 lety

      Good morning sir mera naam nawaj ali hai ham ko H B A C ka karna hai or ham hyedarabad se cors kiye hai 7292855241 I miss job

  • @abduljabbaransari8462
    @abduljabbaransari8462 Před 4 lety +3

    Bohat aala nice work

  • @Anonymous_110
    @Anonymous_110 Před rokem +1

    Getting lots of value from thjs channel. .thanks a lot

  • @fahadraja218
    @fahadraja218 Před 3 lety +1

    Bahut badhia Aapne video banaya hai jazakAllah

  • @muhammadans5951
    @muhammadans5951 Před 3 lety +2

    My lovely teacher
    Super hero engineer
    U r great

  • @HyderAli-qv4fq
    @HyderAli-qv4fq Před 2 lety +2

    Salute to you.. you are wonderful teacher

  • @mohdsiddiquequreshi9054
    @mohdsiddiquequreshi9054 Před 4 lety +2

    Learning practical knowledge thank you

  • @Dilshadkhankolkata
    @Dilshadkhankolkata Před 3 lety +1

    Thanku so much bhaijan bahot acche tarika se btate hai aap😊😊

  • @syedfaiyaz3762
    @syedfaiyaz3762 Před 3 lety +1

    Ma sha Allah, Allah aapko aur tarakhi de

  • @rukhsar07
    @rukhsar07 Před 4 lety +3

    Nicely described with clerifications.

  • @raidon948
    @raidon948 Před 3 lety +2

    very nice practical explaination

  • @mohamedali-ur7op
    @mohamedali-ur7op Před 4 lety +2

    Thanks your concern to share your knowledge

  • @hvac707
    @hvac707 Před 4 lety +5

    Sir my request is to u please make a video on duct testing practically
    How to find out practically
    Like - static pressure, velocity pressure, and cfm

  • @gyaanyeww5197
    @gyaanyeww5197 Před rokem +1

    you have done fantastic job ...i was searching for latest dx chiller n i found here ..lots of love from karnataka ..india ..keep sharing latest equipment details ...thank you

  • @kumarrishikesh6843
    @kumarrishikesh6843 Před 3 lety +2

    Very Nice bro.Allah aap ko madad kare.

  • @designdraftingservices1950

    My super teacher you are great

  • @shahamathahmed
    @shahamathahmed Před 2 lety +1

    Luv d way u have explained Sir .. Crystal clear NGL 👌

  • @user-vm3np2tt9u
    @user-vm3np2tt9u Před 6 měsíci +1

    Tanweer Ahmed Good work keep it

  • @venkatarr
    @venkatarr Před 3 lety +2

    wonderful video. well explained.

  • @sahidmalek652
    @sahidmalek652 Před 4 lety +3

    Thank you sir for this information

  • @fidamuhammad6542
    @fidamuhammad6542 Před rokem +1

    A good informative video.

  • @alihaidar8724
    @alihaidar8724 Před 4 lety +3

    Thanku so much sir for this information.😍

  • @minhaj897
    @minhaj897 Před 2 lety +1

    Nice explanation sir

  • @gongagaming3352
    @gongagaming3352 Před 2 lety +1

    Great 👍

  • @akramhussain6501
    @akramhussain6501 Před 3 lety +1

    Great job sir I am BMS operator but I know about plumbing basic HVAC.

  • @SAHILALI-nr9st
    @SAHILALI-nr9st Před 3 lety +1

    It's really good information

  • @ArshdeepSingh-wb4du
    @ArshdeepSingh-wb4du Před 2 lety +1

    Thanking sir ji

  • @NAsarkar-yq7yq
    @NAsarkar-yq7yq Před 3 lety +2

    Thank you sir🤲🤲🤲

  • @KNOWLEDGEIQ
    @KNOWLEDGEIQ Před 3 lety +1

    May Allah Blesses you good health,I saw your right hand covered with Plaster of Paris,I think Be safe and Delived knowledge .this tutorial with schematic are really good way to Expalnation.Thanks alot for such a great job.

  • @durgab.k.2051
    @durgab.k.2051 Před 4 lety +3

    Thank you for the nice video!

  • @muhammadusmangujjar5437
    @muhammadusmangujjar5437 Před 4 lety +2

    ماشاءالله تبارك الله

  • @ssraorao7565
    @ssraorao7565 Před 4 lety +2

    Excellent your are great 👏

  • @alisher9528
    @alisher9528 Před 4 lety +2

    Knowledgeable

  • @naveedakhtar2979
    @naveedakhtar2979 Před 3 lety +1

    Excellent

  • @fahadraja218
    @fahadraja218 Před 3 lety +1

    Masha Allah bahut acha

  • @hoshsethar6698
    @hoshsethar6698 Před 3 lety +2

    Good knowledge

  • @fahadraja218
    @fahadraja218 Před 3 lety +1

    Nice explain

  • @rameezraja7778
    @rameezraja7778 Před 4 lety +2

    Great defined Brother

  • @rahulrajbhar7918
    @rahulrajbhar7918 Před 3 lety +1

    Bahut achcha aapane bataya sar

  • @horizonparvez3612
    @horizonparvez3612 Před 4 lety +2

    Great job sir.

  • @fahadraja218
    @fahadraja218 Před 3 lety +1

    Very nice

  • @abdulnabi7912
    @abdulnabi7912 Před 4 lety +2

    Keep it up...good

  • @MohammadDanish-yf5ro
    @MohammadDanish-yf5ro Před 3 lety +2

    Excellent bro

  • @mohammedjaberasim8259
    @mohammedjaberasim8259 Před 5 měsíci +1

    Good sir

  • @irshadqureshi3596
    @irshadqureshi3596 Před 4 lety +1

    Very good enformatiom

  • @chrisshine3953
    @chrisshine3953 Před 4 lety +2

    Thank you Sir!!!

  • @hvacengineerhvacengineer6101

    Weldon sir

  • @kishanbhargava6890
    @kishanbhargava6890 Před 2 lety

    Explained clearly👍

  • @piyushpandey6303
    @piyushpandey6303 Před 3 lety +1

    v good

  • @hvac707
    @hvac707 Před 4 lety +2

    Nice video sir

  • @RajendarKumar-di7qn
    @RajendarKumar-di7qn Před 3 lety +1

    Good

  • @khansalahuddin8986
    @khansalahuddin8986 Před 2 lety +2

    Sir aap ke bms me fault chaq kaise krte hai uska mentaince kaise krte hai iska vedio de

  • @villagemedia8594
    @villagemedia8594 Před 4 lety +1

    Thank you sir

  • @ahsanayyaz6310
    @ahsanayyaz6310 Před 2 lety +1

    nice

  • @danishakram9831
    @danishakram9831 Před 3 lety +1

    Sir please make videos package unit control and wiring of Dunhum bush company

  • @mdshamimhossen1541
    @mdshamimhossen1541 Před 5 měsíci +1

    ❤️❤️❤️

  • @lovesongsandbabytvchannel8898

    Hi may i request for english sub title? Because some of us watching your because cannot understand your language. Highly appreciate if you do that. Because I know, you can share many informations regarding to HVAC System.Thank you..

  • @shahamathahmed
    @shahamathahmed Před 2 lety +1

    Subscribed

  • @MRKROLEX786
    @MRKROLEX786 Před 4 lety +1

    Good video

  • @awaheedshaikh4962
    @awaheedshaikh4962 Před 8 měsíci +1

    What is difference between Dx type and VrF ac units.
    Please share immediately for interview

    • @TanweerAhmed
      @TanweerAhmed  Před 8 měsíci

      Single split DX type unit run constantly and VRF type units are variable according to load. VRF units are also DX type. VRF units are energy saving and DX are not energy saving

  • @mozammilimam7880
    @mozammilimam7880 Před 3 lety +2

    AHU me Air pressure switch kyun use krte hain?

    • @TanweerAhmed
      @TanweerAhmed  Před 3 lety

      Air pressure switches is a device used to actuate an electric switch based on differential pressure across two points and this electric switch used to sense airflow status across the fans, dirty status across the filters in air handling unit or it can be used to connect any control circuit to perform the required operation when switching condition goes on and off

  • @The-hvac-life-of-Dubai-1997

    Nice

  • @armanraja8363
    @armanraja8363 Před 4 lety +1

    Thanks boss

  • @HaniRao-gk6iw
    @HaniRao-gk6iw Před 2 měsíci +1

    Sir, package unit pr video bna dejay

  • @mohdviquar5875
    @mohdviquar5875 Před rokem +1

    Sir FAHU me blower suction side par casing lagi hui hai toh woh suction kaha se karega aagey cool air ko discharge karne ke liye

  • @tajammulhussainKhadir
    @tajammulhussainKhadir Před 4 lety +2

    Acha ye batao vrv outdoor unit se ahu ko jo refrigerants (supply and return ) line jaati hai uspe motorized valve and temperature sensor lagte hain ya nahi?

    • @TanweerAhmed
      @TanweerAhmed  Před 4 lety

      This video is not related VRV. No motorized valve is used in VRV as I know. Temperature sensors are used.

  • @ajaxtyson
    @ajaxtyson Před rokem +1

    Sir, aapne jo video me AHU bataya usska CFM capacity kya he?

    • @TanweerAhmed
      @TanweerAhmed  Před rokem +1

      I have not memorized. But different according to area and conditions wise

  • @gulabrbbani2261
    @gulabrbbani2261 Před 3 lety +2

    FAHU or AHU ME difference samajh me aaraha hai Sir..but treated fresher air handling unit nahi samajh pa raha hu.

    • @TanweerAhmed
      @TanweerAhmed  Před 3 lety +1

      Treated fresh air handling unit may jo fresh air 100% supply ki jatey hy usay treat kiya jata hay. Is ka matlab ye hay ka, fresh air ko cool kya jata hay, ya humity control ki jati hay, ya heat kiya jata hay, etc.

    • @gulabrbbani2261
      @gulabrbbani2261 Před 3 lety +1

      @@TanweerAhmed thank you sir

  • @muhammadimranusman8404
    @muhammadimranusman8404 Před 3 lety +2

    As slam u alaikm sir please answer me very fast ,diploma Mera hvac me he aur b.tech electrical me he halnkey mechanical me krna tha ab me Kya karu.

  • @ajaxtyson
    @ajaxtyson Před rokem +1

    Sir Kitne condenser dx unit chahiye ye kaise decide hota he? Agar area ke upar hota he to ek dx unit kitna area cover karta he? Thank you.

    • @TanweerAhmed
      @TanweerAhmed  Před rokem +1

      You will not understand without proper design. It is not simple. Get help from designer

  • @jafaragharia8560
    @jafaragharia8560 Před 3 lety +1

    Good information.
    FAHU minimum kitne ton ka hota hai

  • @praveenpoojary6024
    @praveenpoojary6024 Před 2 lety +1

    York DX unit system showing flow switch open . Condensing unit going to off plz give suggestion

    • @TanweerAhmed
      @TanweerAhmed  Před 2 lety

      There is problem which should be trace out practically. May be switch faculty

  • @muzaffershaik8336
    @muzaffershaik8336 Před rokem +1

    Sir It’s is acceptable DOAS return duct connected to toilets(restrooms) to suck return air frm toilets(restroom) please clarify?

  • @moazzamkhot8900
    @moazzamkhot8900 Před 11 dny +1

    Sir what is coil temperature before and after coil,

  • @Mdirfan-tf8hb
    @Mdirfan-tf8hb Před 3 lety +2

    Bhai return air supply ke bare mein aap kuchh nahin bataya ?

    • @TanweerAhmed
      @TanweerAhmed  Před 3 lety

      This is treated 100% Fresh Air Unit and therefore no return fresh is used

  • @waqarjaved6642
    @waqarjaved6642 Před 3 lety +2

    Please also guide about electric Load according to the size of ac

    • @TanweerAhmed
      @TanweerAhmed  Před 3 lety

      Normally electrical load taken from different vendors catalogues of AC units

    • @waqarjaved6642
      @waqarjaved6642 Před 3 lety

      @@TanweerAhmed sir i want to instal this system in my school

    • @TanweerAhmed
      @TanweerAhmed  Před 3 lety

      @@waqarjaved6642 Before installing designing is required. If you will start designing process from designer then you will find out all parameters

    • @waqarjaved6642
      @waqarjaved6642 Před 3 lety

      @@TanweerAhmed sir I am totally blind about it do you have any contacts who can do this all for me

    • @TanweerAhmed
      @TanweerAhmed  Před 3 lety

      Do you want to design HVAC system? If yes then share email address for further coordination

  • @sankarrama8430
    @sankarrama8430 Před 4 lety +2

    Sir ahu aur fahu me kya anter hoti hai plz esper video banaeeye

    • @TanweerAhmed
      @TanweerAhmed  Před 4 lety +1

      Ok noted....but simply difference is that FAHU take 100% fresh air & supply to condition room and AHU take some % fresh air & 80% to 90% return air from room then supply to condition room.

  • @nse08
    @nse08 Před 2 lety

    @13:50 fan reverse rotation, a bit fun ! Why do dirty inside fan compartment ?

    • @TanweerAhmed
      @TanweerAhmed  Před 2 lety

      In video you feeling like this but practically rotating in right direction. Practically record roof fan video then you will feel like same. You should focus on the content, not on house keeping.

  • @ZeeShawn
    @ZeeShawn Před 4 lety +2

    Silencer bhi laga Hota hai duct m

    • @TanweerAhmed
      @TanweerAhmed  Před 4 lety

      It is called acoustic liner or sound liner which reduce the noise of duct

    • @ZeeShawn
      @ZeeShawn Před 4 lety

      sound attenuator is use in fresh air duct or EAD
      Sound attenuator we can also say silencer

  • @jamsheerali7229
    @jamsheerali7229 Před 3 lety +1

    Sir .. why we are using bleed fan for DX fahu? What is inertial filter ?

    • @TanweerAhmed
      @TanweerAhmed  Před 2 lety

      I have not seen any bleed fan installation for DX FAHU. Bleed fan are used for industrial environmental purpose or in aeroplane. Inertial filters are also used mostly for industrial filtration purpose.

  • @shaukathayat1083
    @shaukathayat1083 Před 4 lety +3

    Good Video. Sir FAHU total kitney types k hotey hain?

    • @TanweerAhmed
      @TanweerAhmed  Před 4 lety +1

      Basic two type i.e. (1) Treated fresh air (2) Non treated fresh air.

    • @TanweerAhmed
      @TanweerAhmed  Před 4 lety +1

      In treated fresh air has further clarification i.e. 1st DX coil and 2nd Chiller water coil

    • @shaukathayat1083
      @shaukathayat1083 Před 4 lety +1

      Tanweer Ahmed thanks 🙏

    • @TanweerAhmed
      @TanweerAhmed  Před 4 lety

      Non treated fresh air is that which is supply without cooling or without treat, means atmosphere air

    • @TanweerAhmed
      @TanweerAhmed  Před 4 lety

      @Design Hub yes, you are right

  • @nadeemmallick7453
    @nadeemmallick7453 Před 2 lety

    And sir make a video of hru fahu with full specification

  • @vishwanathkchavan1739
    @vishwanathkchavan1739 Před rokem +1

    Dear sir why we use rutrn air duct

    • @TanweerAhmed
      @TanweerAhmed  Před rokem

      Return air ducts in AHUs play a crucial role in maintaining indoor air quality, energy efficiency, and comfortable conditions within a building. They allow the HVAC system to efficiently recirculate and condition air, leading to better control over temperature, humidity, and overall indoor environment.

  • @raushankumarsharma725
    @raushankumarsharma725 Před 2 lety

    sir, How to connection between AHU and ACCU unit from start to end including of foundation (concrete pad) please make One video

  • @abidrazashakeb8457
    @abidrazashakeb8457 Před rokem +1

    One query sir kindly solve the problem, in FAHU system both condenser & evaporator are connected to each other in one box ?

    • @TanweerAhmed
      @TanweerAhmed  Před rokem

      This is called package unit like window AC unit

    • @abidrazashakeb8457
      @abidrazashakeb8457 Před rokem +1

      Basically sir mujhe information chahye Dx FAHU & simple FAHU details ..

    • @TanweerAhmed
      @TanweerAhmed  Před rokem

      Simple FAHU is without coil and treated FAHU is with coil

  • @alalmolla3725
    @alalmolla3725 Před 3 lety +1

    Sar dunham bush ahu ma Ferzz poraction alarm comprasar off ata ha plees ansar me

    • @TanweerAhmed
      @TanweerAhmed  Před 3 lety

      Practically to be check compressor and their control system. Moreover, there are more than one compressor and they run all on full load. If load is partial then may be one compressor start and other remain off.

  • @abujarhossen2160
    @abujarhossen2160 Před rokem +1

    FAHU connect with chillers?

  • @haseekhas1102
    @haseekhas1102 Před 3 lety +2

    Sir thank you this video but I need this wiring system please

  • @jamsheerali7229
    @jamsheerali7229 Před rokem +1

    Hi sir .. what is steam type built in humidifier in AHU ,,, is it for humidification or de-humidification ? Please advise in detail

    • @TanweerAhmed
      @TanweerAhmed  Před rokem

      It is used for Humidification if steam used as mist and used for Dehumidification if steam used in coil for heating purpose.

    • @jamsheerali7229
      @jamsheerali7229 Před rokem

      @@TanweerAhmed it can use both humidification and de humidification ? Through DDC ?

    • @TanweerAhmed
      @TanweerAhmed  Před rokem

      My answer is same, further check at your end

  • @minhaj897
    @minhaj897 Před 2 lety +1

    How to calculate tonnage of fresh air handling unit.
    For 3500 CFM. Region is Islamabad, Pakistan .
    Actually I don't know about the formula use.
    4.45 × Delta h × CFM. Is this formula will be used for calculating the Capacity?
    I don't know about the entering enthalpy and leaving enthalpy.
    What should be the entering conditions (Dry and wet bulb temperature for Islamabad, Pakistan)and leaving conditions (dry bulb and wet bulb temperature) for Islamabad, Pakistan.
    Sir kindly reply in comment here these questions for FAHU Capacity calculations. THANKS.
    Also what is the out door design dry bulb and wet bulb conditions of Islamabad, Pakistan.
    Islamabad ,Pakistan altitude is 1667 feet in 2009 ASHRAE Handbook - Fundamentals (IP). How to calculate psychrometric properties for this altitude. Because the Ashrae Chart 1 is for Sea leavel O feet Altitude.
    And please also make a video in details about the FAHU CFM calculations.how much fresh air CFM is required and schedule with capacity calculations of FAHU.

    • @TanweerAhmed
      @TanweerAhmed  Před 2 lety +1

      Join HVAC design course from any institute or get help from experience designer

    • @minhaj897
      @minhaj897 Před 2 lety +1

      Thank you sir.
      Can you please suggest me the HVAC Design institution in Islamabad. Because I also do job in Islamabad in I9/2

    • @TanweerAhmed
      @TanweerAhmed  Před 2 lety +1

      Suggest to search on Google "HVAC design course in Islamabad" hopefully you will find

    • @minhaj897
      @minhaj897 Před 2 lety +1

      @@TanweerAhmed
      Thanks alot sir

  • @MohammadDanish-yf5ro
    @MohammadDanish-yf5ro Před 3 lety +1

    Sir plz tell me how to set point of this chiller db.plzz

    • @TanweerAhmed
      @TanweerAhmed  Před 3 lety

      Temperature can set through its panel screen. Only technical person set parameters because if any thing insert wrong then chiller can problem

  • @afwmrepairentertainment2432

    assalamuialikum sir 44 umar hai meri aur experience bhi hai gulf ki liye hvac technician ki liye job 44 umar walu ko abhi job offfers hair sir please bataiye sir

    • @TanweerAhmed
      @TanweerAhmed  Před rokem

      If you are interested then avail this opportunity

  • @yasirafzal4267
    @yasirafzal4267 Před 2 lety +1

    Heating k liye Kya karna padta hai?

    • @TanweerAhmed
      @TanweerAhmed  Před 2 lety

      DX-coil is used which is reversible means heating and cooling.

  • @jamsheerali7229
    @jamsheerali7229 Před 2 lety +1

    Hi sir .. shall we consider supply fan static pressure for designing sand trap louver ?

    • @TanweerAhmed
      @TanweerAhmed  Před 2 lety +1

      I am not design Engineer but I think, it should be consider

  • @sashidhar3025
    @sashidhar3025 Před 3 lety +1

    Sir . Here in dx coil doesn't have chill supply and return line

    • @TanweerAhmed
      @TanweerAhmed  Před 3 lety

      DX coil no required chilled water

    • @sashidhar3025
      @sashidhar3025 Před 3 lety +1

      @@TanweerAhmed ok sir .Sir can u give vedio of chill water supply and return pump room vedio

    • @TanweerAhmed
      @TanweerAhmed  Před 3 lety

      Ok noted

  • @jamirkhan1137
    @jamirkhan1137 Před 2 lety +1

    Iska maintenance me kaya karne parta hain bhai jaan

  • @jamsheerali7229
    @jamsheerali7229 Před 3 lety +1

    Thank u sir.. Can u please explain testing and commissioning of AHU accu , checklists etc…

    • @TanweerAhmed
      @TanweerAhmed  Před 3 lety

      Welcome, Insha'Allah will explain

    • @jamsheerali7229
      @jamsheerali7229 Před 3 lety +1

      @@TanweerAhmed thank you sir .. is it mandatory to insulate all the refrigerant pipes ( eg: liquid lines, HOt gas bypas) ???

    • @TanweerAhmed
      @TanweerAhmed  Před 3 lety

      Yes it is

    • @jamsheerali7229
      @jamsheerali7229 Před 3 lety +1

      @@TanweerAhmed why it is needed? AHU and accu are in out side of building..

    • @TanweerAhmed
      @TanweerAhmed  Před 3 lety +1

      Because ambient temperature and refrigerant or chilled water temperature is different therefore heat transfer and energy loss

  • @rameezkhan7697
    @rameezkhan7697 Před 9 měsíci +1

    Is mey expansion valve arey hy??