HOW TO RECOVER REFRIGERANT "FASTER"FROM AN AC SYSTEM
zhlédnutí 379Před 9 hodinami
In this video I will take you step by step how to recover refrigerant faster from an AC system. www.supplyhouse.com/Appion-MGAVCT-1-4-Valve-Core-Removal-Tool?Shopping_Neutral_New_users&gad_source=1&gclid=CjwKCAjw9IayBhBJEiwAVuc3fqH0EoehvMYnkDl3om4abW_spf_BoCAssv4r1Dk76I5dtKkQIW5bChoCUkAQAvD_BwE trutechtools.com/MGABAS?gad_source=1&gclid=CjwKCAjw9IayBhBJEiwAVuc3fuB7DPV7gVjJ3mJKCgdrL3sfLprLbgNX7u...
WHAT TO DO WHEN YOU HAVE LONGER AIR CONDITIONER LINE SET.
zhlédnutí 444Před 21 hodinou
In this video I will show you step by step what to do when you have longer line sets on an air conditioner.
HOW TO LEAK TEST AN AC SYSTEM WITH NITROGEN PRESSURE
zhlédnutí 237Před 14 dny
In this video I will show you step by step how to leak test an AC system with nitrogen pressure. www.amazon.com/Regulator-Connection-Heavy-Duty-Self-reseating-NAKAO/dp/B08SJBVS45/ref=asc_df_B08SJBVS45/?tag=hyprod-20&linkCode=df0&hvadid=507714472492&hvpos=&hvnetw=g&hvrand=8837598213913646555&hvpone=&hvptwo=&hvqmt=&hvdev=c&hvdvcmdl=&hvlocint=&hvlocphy=9021511&hvtargid=pla-1295324872303&psc=1&mcid...
HOW TO RECOVER REFRIGERANT FROM AN AC UNIT.
zhlédnutí 328Před 21 dnem
In this video I will show you step by step how to properly recover refrigerant from an AC unit. This method is the most used and the slowest. www.amazon.com/Robinair-RG3-Twin-Cylinder-Portable-Refrigerant/dp/B00NMOYPVG/ref=sxin_16_pa_sp_search_thematic_sspa?content-id=amzn1.sym.15bb851a-7b12-4426-b7a1-b84d50f201d9:amzn1.sym.15bb851a-7b12-4426-b7a1-b84d50f201d9&crid=FPOHCNANXNQC&cv_ct_cx=robinai...
HOW TO USE A HVAC CHEATER CORD
zhlédnutí 368Před měsícem
In this video I will show you step by step how to get 120 volts out of a 240 condensing unit. www.amazon.com/Adaptor-Accessories-Compatible-Extension-Breaker/dp/B0BG6J178N/ref=asc_df_B0BG6J178N/?tag=hyprod-20&linkCode=df0&hvadid=652455257749&hvpos=&hvnetw=g&hvrand=5784130862779723408&hvpone=&hvptwo=&hvqmt=&hvdev=c&hvdvcmdl=&hvlocint=&hvlocphy=9021511&hvtargid=pla-2003525980999&psc=1&mcid=d3ef18...
HOW TO SNAKE STEP BY STEP A 2 IN DRAIN WITH A RIDGID K400 3/8 SNAKE AUGER
zhlédnutí 199Před měsícem
In this video I will take you step by step how to clean a 2 In drain with a K400 snake auger machine.www.homedepot.com/p/RIDGID-K-400-Drain-Cleaning-Snake-Auger-120-Volt-Drum-Machine-with-C-32IW-3-8-in-x-75-ft-Cable-4-Piece-Tool-Set-Gloves-52363/206405033?source=shoppingads&locale=en-US&pla&mtc=SHOPPING-BF-CDP-GGL-D26P-026_007_PLUMB_REPAIR-NA-NA-NA-PMAX-NA-NA-NA-NA-NBR-NA-NA-NEW-PMax&cm_mmc=SHO...
HOW TO REPLACE A FRIGIDAIRE MICROWAVE/HOOD FUSE
zhlédnutí 204Před měsícem
In this video I will show you step by step how to install a frigidaire micro hood fuse. www.amazon.com/dp/B0CQ59182D?psc=1&smid=A3FX7C4A9P37IQ&ref_=chk_typ_imgToDp
GE DISH WASHER BEEPING 3 TIMES. DOOR LOCK AND CONTROL BOARD REPLACED.
zhlédnutí 106Před měsícem
In this video I will show you how to troubleshoot and replace the door lock and the control board. DW M# GDF610PMJ2ES
ELECTRIC BURNER TOO HOT IN LOW SETTING. HOW TO RELPLACE THE INFINITY SWITCH.
zhlédnutí 170Před 2 měsíci
In this video I will take you step by step how to troubleshoot an infinity switch and how to replace it.
CEILING FAN LIGHTS DONT WORK OR FLICKERING. TROUBLESHOOTING. REPLACED WATT LIMITER.
zhlédnutí 181Před 2 měsíci
In this video I will show you how to troubleshoot a ceiling fan light that does not work or it flickers. We are going to replace the watt limiter.
HOW TO REPLACE A KOHLER TOILET FLUSH VALVE SEAL
zhlédnutí 5KPřed 2 měsíci
In this video I will show you step by step how to install a Kohler toilet flush valve seal. www.homedepot.com/p/KOHLER-Seal-for-All-Single-Flush-Class-5-and-Class-6-Canister-Toilets-K-GP1059291/202524230 www.homedepot.com/p/Korky-Universal-3-in-Flush-Valve-Seal-Kit-435CM/202402377
REFRIGERATOR NOT COOLING ENOUGH. REPLACED FAULTY CONDENSER FAN MOTOR.
zhlédnutí 511Před 2 měsíci
In this video I will take step by step how to remove and install condenser fan motor.
DISH WASHER NOT WORKING. IT SHUTS OFF AFTER 2 MIN. PRESSURE SENSOR FAULTY
zhlédnutí 86Před 2 měsíci
DISH WASHER NOT WORKING. IT SHUTS OFF AFTER 2 MIN. PRESSURE SENSOR FAULTY
WATER HEATER INSTALLATION WITH RIDGID MEGA PRESS AND PRO PRESS.
zhlédnutí 576Před 3 měsíci
WATER HEATER INSTALLATION WITH RIDGID MEGA PRESS AND PRO PRESS.
HOW TO REPLACE B AND G PUMP COUPLER AND MOUNTS (100 SERIES)
zhlédnutí 265Před 3 měsíci
HOW TO REPLACE B AND G PUMP COUPLER AND MOUNTS (100 SERIES)
HOW TO REPLACE A WATER MAIN VALVE INSIDE A HOUSE WITH THREADED FITTINGS.
zhlédnutí 417Před 3 měsíci
HOW TO REPLACE A WATER MAIN VALVE INSIDE A HOUSE WITH THREADED FITTINGS.
HOW TO INSTALL A CERAMIC FLOOR STEP BY STEP USING THE RUBI CYCLONE LEVELING SYSTEM.
zhlédnutí 302Před 3 měsíci
HOW TO INSTALL A CERAMIC FLOOR STEP BY STEP USING THE RUBI CYCLONE LEVELING SYSTEM.
HOW TO REPLACE A WATER HEATER TEMPERATURE/PRESSURE RELIEF VALVE.
zhlédnutí 596Před 4 měsíci
HOW TO REPLACE A WATER HEATER TEMPERATURE/PRESSURE RELIEF VALVE.
WHITE RODGERS 1311-102 STEP BY STEP REPLACEMENT.
zhlédnutí 694Před 4 měsíci
WHITE RODGERS 1311-102 STEP BY STEP REPLACEMENT.
HOW TO REPLACE A COPPER PIPE THAT WASNT COPPER . IT WAS BRASS!!!! YIKES!!!!
zhlédnutí 405Před 4 měsíci
HOW TO REPLACE A COPPER PIPE THAT WASNT COPPER . IT WAS BRASS!!!! YIKES!!!!
HOW TO REPLACE A BOILER PRESSURE VALVE. SAFETY AND HOW IT WORKS.
zhlédnutí 424Před 4 měsíci
HOW TO REPLACE A BOILER PRESSURE VALVE. SAFETY AND HOW IT WORKS.
WATER HEATER VS BOILER TEMPERATURE/PRESSURE RELIEVE VALVE. I REPLACED BOTH.
zhlédnutí 209Před 4 měsíci
WATER HEATER VS BOILER TEMPERATURE/PRESSURE RELIEVE VALVE. I REPLACED BOTH.
BOILER LOW VOLTAGE THERMOSTAT WIRING PROBLEM. EASY FIX
zhlédnutí 235Před 5 měsíci
BOILER LOW VOLTAGE THERMOSTAT WIRING PROBLEM. EASY FIX
HOW TI FIX/RE-ANCHOR A LAMP POST USING AN ELECTRIC CONCRETE BREAKER
zhlédnutí 86Před 5 měsíci
HOW TI FIX/RE-ANCHOR A LAMP POST USING AN ELECTRIC CONCRETE BREAKER
WHAT TO DO WHEN YOUR GARAGE DOOR DOESNT CLOSE AND THEN IT GOES BACK UP
zhlédnutí 221Před 5 měsíci
WHAT TO DO WHEN YOUR GARAGE DOOR DOESNT CLOSE AND THEN IT GOES BACK UP
HONEYWELL ZONE VALVE FAILED STUCK OPEN. HOW TO REPLACE IT.
zhlédnutí 5KPřed 6 měsíci
HONEYWELL ZONE VALVE FAILED STUCK OPEN. HOW TO REPLACE IT.
HOW TO REPLACE A SUBMERSIBLE WELL PUMP. STEP BY STEP
zhlédnutí 12KPřed 6 měsíci
HOW TO REPLACE A SUBMERSIBLE WELL PUMP. STEP BY STEP
LOCHINVAR FTLX LOCKOUT INLET SENSOR FAULT
zhlédnutí 1,1KPřed 7 měsíci
LOCHINVAR FTLX LOCKOUT INLET SENSOR FAULT
MUNCHKIN BOILER. HOW TO CLEAN HEAT EXCHANGER. REPLACED TARGET WALL, BURNER SEAL, DOOR GASKET ETC.
zhlédnutí 1,8KPřed 7 měsíci
MUNCHKIN BOILER. HOW TO CLEAN HEAT EXCHANGER. REPLACED TARGET WALL, BURNER SEAL, DOOR GASKET ETC.

Komentáře

  • @user-rx8tg6yz4t
    @user-rx8tg6yz4t Před 17 hodinami

    Did you use different wax or the one that comes with the toilet??

    • @alexthehandyman3494
      @alexthehandyman3494 Před 17 hodinami

      HELLO I used a different one. Thicker and taller with no core reinforcement. #10 from Menards or Home Depot. However the one that comes with is perfectly fine. Thanks.

  • @josemederos1305
    @josemederos1305 Před 18 hodinami

    do you have a video to trouble shoot speed queen washer commercial card is not reading

  • @Ih8chew
    @Ih8chew Před 18 hodinami

    I’m dealing with having to replace this relic right now along with my 20 year old AC condenser. Same set up, no heating just AC. l’m getting quotes of $4k-$6 for the condenser plus another $$3k-$6k to change out the ceiling mounted fan coil. So far two quotes are $9.3k and $10k. Absolute insanity, I had no clue how much this type of set up costs. If you have this definitely keep up the maintenance because you’re on borrowed time and it’s gonna be a fortune to replace.

  • @richlikeg3722
    @richlikeg3722 Před dnem

    Great video tutorial. So these new condensers don’t come pre-charge with any refrigerant?

    • @alexthehandyman3494
      @alexthehandyman3494 Před 19 hodinami

      Hello Yes they do. This one in particular is 5 years old and it lost its refrigerant through a leaky valve.

  • @Wen-mx8ey
    @Wen-mx8ey Před dnem

    You explain so well thank you

  • @andreyliakhnovich2177

    Tanks

  • @zekenzy6486
    @zekenzy6486 Před 2 dny

    Great video. Thank you for sharing

  • @Samlol23_drrich
    @Samlol23_drrich Před 2 dny

    So you ran the evacuation pump with the hoses reversed? It pulled from the tank and spit it into the low side of the system? I’ve never seen that before. Well done. So you can pull down to 200 microns with just an evacuation pump? I saw a dedicated vacuum pump there. You didn’t use that? Why do most guys have both then? Did it just take longer? Thanks. Great vid.

    • @alexthehandyman3494
      @alexthehandyman3494 Před 2 dny

      Morning Richard, Yes the recovery machine doesn't know what is transferring to. It is a device to transfer refrigerant (recover ) from one place to another. From the condenser through the recovery machine to the tank. In this case is going from the tank through the recovery machine to the condenser. It is important to use dedicated hoses to recover and different hoses to vacuum. Vacuum hoses need to be clean to pull an easier vacuum. Yes the vacuum pulled easily to 200 microns. It took me 5 min. It is important to mention that on the vacuum I used thicker hoses and no restrictions. When using regular 1/4 houses with cores and core depressors it can take easily 20-30 minutes. Thanks you so much for your support!!!

    • @Samlol23_drrich
      @Samlol23_drrich Před 2 dny

      @alexthehandyman3494 Thanks for the boatload of info! I have a cheap vacuum pump I've used for my car But always wanted an inexpensive recovery machine. Maybe, just maybe. Thanks again

  • @jinwonjang9199
    @jinwonjang9199 Před 3 dny

    thank you so much! saved $300 and time. I just changed the coils and works greatly. Thank you again!

    • @alexthehandyman3494
      @alexthehandyman3494 Před 3 dny

      My pleasure. Thank you. Don’t forget to like the video. FYI I have a couple dozen videos on SPEED QUEEN

  • @sniper13425
    @sniper13425 Před 4 dny

    i get an air bubble in my toilet during the flush. Alex, do I have to change the flush valve seal in order to get rid of that?

  • @sniper13425
    @sniper13425 Před 4 dny

    is it supposed to bubble just before the water goes down the toilet? Does anybody else have a problem with this model?

  • @Samlol23_drrich
    @Samlol23_drrich Před 4 dny

    As a homeowner, it’s a lot of expensive stuff, even though I got my 608 certification so I can take care of my own two R22 old systems. Each appion is $70, the recovery machine is $500 to $1000, the scale, the recovery tank, the turbo torch and tanks, vacuum pump, even the large vacuum hoses are $60 each. Forget about something like a digital manifold. Big initial investment! That’s before the refrigerant! I spent almost $800 for 30# of R22. Thanks for sharing your knowledge- I should have gone into HVAC. I find it interesting. But you do it all.

    • @alexthehandyman3494
      @alexthehandyman3494 Před 3 dny

      YEAP. As a home owner it doesn't make sense. Why did you get your 608 certification? Wanted to work on Hvac for money. Or just for fun? Greetings!

    • @Samlol23_drrich
      @Samlol23_drrich Před 3 dny

      @@alexthehandyman3494 it almost makes sense, since r22 is so expensive if I call someone. So my house was built in 89. We’ve lived in it 13 years. I have two original Armstrong air R22 units and my original peerless oil boiler. I service them all. The AC I’ve never let anyone touch, since it’s so old and has worked fine. I’ve never even put gauges on it. A few capacitors over the years, a condenser fan or two, and maybe an air handler transformer. About 5 years ago I bought 5# of R22 on eBay. Last summer for the first time ever it wasn’t blowing cold. I studied and took and passed the 608 universal so I could check the pressure and add the refrigerant myself. Small leak in one of the schrader valves on the high side. I added some r22 until the superheat was where it should be (piston), but didn’t change the core yet. I bought 2 of the valve stem removers but I’m afraid since the nylog I put on it seemed to stop the leak. It’s been fine this year after sitting all winter. Plus, I wanted to buy some more r22 just in case. The reality is where I live if anyone came to my house to do any service on the AC, I’d be left with a bill for 50k to replace both units. I love .r22 and the piston. Don’t want to change it unless I must. Thanks for the videos. I always learn a lot. Edit. Oh, and I already had to change the condensate pan in my attic once. It was rusted through. I did it without pumping down my system. If it ever happens again, I will have options, and maybe do it the right way, recover, fix and recharge. Couldn’t do that last time.

  • @LouisS-cs7bh
    @LouisS-cs7bh Před 4 dny

    I like the way you explain the process step by step. Thank you for sharing your knowledge!!

  • @koc5942
    @koc5942 Před 4 dny

    Thank you 🙏

  • @dionysus2006
    @dionysus2006 Před 4 dny

    Great video !!

  • @adolfolopez224
    @adolfolopez224 Před 5 dny

    Excelente dia espero me puedas ayudar soy de la ciudad de México y tengo una lavadora speed Queen la falla que hace es que al drenar el agua empieza a tronar en tu experiencia crees que sea la hélice y la polea que ya se encuentra desgastadas

  • @dianataylor8685
    @dianataylor8685 Před 5 dny

    I agree. I've watched the other ones where they talk and talk, innecessarily. YOURS is short and sweet. And to the point, you can pause it and watch what to do. I am a 57-year-old woman and I feel like a plumber. Yay Me and Yay you.

  • @hardcorefishermen
    @hardcorefishermen Před 6 dny

    i a certified electrician and engineer, a clogged filter will not raise the circuit load for the type of window unit in the video, the efficiency will be lowered but it will not "do more work" the thermostat will simply run the compressor longer (not harder)to achieve the same temperature

  • @slshock
    @slshock Před 7 dny

    Excellent video! Exactly the CZcams training I needed.

  • @jimgarcia5165
    @jimgarcia5165 Před 7 dny

    First of all the line is not installed correctly, it is not insulated, what happened to trip over it?

  • @williardbillmore5713

    You can use them ,but they will leak... That is the real answer.

  • @JimmieLannon
    @JimmieLannon Před 7 dny

    That is the craziest line set installation .....definetly some hack jobs

  • @invisibles362
    @invisibles362 Před 8 dny

    The refrigeration line set is not install professionnely, it looks really bad. It looks like spider webs. 😂

  • @richlikeg3722
    @richlikeg3722 Před 8 dny

    Good video. You charging with r22? With Goodmans, any length longer than 35ft I usually add a hard start to help the compressor.

    • @alexthehandyman3494
      @alexthehandyman3494 Před 8 dny

      Yes 22. This property bought 30 condensers with( 22)10 yrs ago. They are stuck with them. I guess when these new batch fail or lose refrigerant then we ll convert them with a newer refrigerant. Thanks for the hard start kit. That’s a good idea. Thanks for the tip.

  • @hunterrosen8157
    @hunterrosen8157 Před 8 dny

    My filter button won’t turn on.. idk how to get on I press the button but it won’t go back on. Do I need to press it for atleast 3 seconds?

  • @robstapp4817
    @robstapp4817 Před 8 dny

    good job

  • @robstapp4817
    @robstapp4817 Před 8 dny

    well done

  • @LAGGER7941
    @LAGGER7941 Před 9 dny

    thankyouuu

  • @EFIL4NAISREP
    @EFIL4NAISREP Před 10 dny

    Nice video!

  • @CEINOLHomeDecor
    @CEINOLHomeDecor Před 12 dny

    If you looking for a reliable waterfall faucet. CEINOL will be a good choice.

  • @TheresaMareschal
    @TheresaMareschal Před 13 dny

    Fantastic video and directions. So simple to follow a cave man could do it! Thank you.

  • @Samlol23_drrich
    @Samlol23_drrich Před 14 dny

    Great. Thanks. Is that the same tank you use when you brazed the linesets?

    • @alexthehandyman3494
      @alexthehandyman3494 Před 13 dny

      Hello Richard. Yes it is. That tank is 40cu/ft About 30 $$. Tank is about 170. Take care!! Thank you so much

  • @APTKSU
    @APTKSU Před 16 dny

    Super helpful!! Thank you.

  • @doublee94
    @doublee94 Před 16 dny

    Do you have to worry about discharging the capacitor before replacing the fuse?

  • @martymarr8307
    @martymarr8307 Před 18 dny

    I got a stove and the old hose doesnt fit the new one and i cant get it off should i just add an adapter

    • @alexthehandyman3494
      @alexthehandyman3494 Před 17 dny

      Yes just add an adapter. If your gas flex line is too old (10 yrs or more). I suggest you get a new one.

  • @leomurphy9205
    @leomurphy9205 Před 18 dny

    Alex - You are one of the very best Teachers / Instructors I have ever seen!

  • @DosDonts101
    @DosDonts101 Před 19 dny

    Sounds like jumanji

  • @johncasor9698
    @johncasor9698 Před 19 dny

    @ 7:50 i would not touch remove that air dome, just leave it alone, it could start leaking or you could break it or crack it, then what ??? so just leave it alone ,,, you can just remove the little hose on it, that is better then messing with pulling and pushing on it believe me... that air dome is old and brittle and can break or splinter crack then you screwed...

    • @alexthehandyman3494
      @alexthehandyman3494 Před 19 dny

      Hey John, That's very true!! Thank you so much for your input. Greetings !!

  • @jkehoe100
    @jkehoe100 Před 19 dny

    Thank you for the tutorial. By the way, my tree died. Turned out that was its only root. 🥲

  • @overlandersnorthwest
    @overlandersnorthwest Před 19 dny

    Mine is still clogged with the 25 foot snake.

    • @alexthehandyman3494
      @alexthehandyman3494 Před 19 dny

      Did you make sure it went down. Did you see it physically, If it went up then you went through the vent. It needs to go down. Let me know.

    • @alenbazarov3039
      @alenbazarov3039 Před 19 dny

      @@alexthehandyman3494yes brother, I made sure it went down and put full 25 ft snake in, when pulled back nothing came out and then I put a 5 gal bucket of water in each at the same time and it was draining good until the very end it stopped draining again. Help bro !

    • @alexthehandyman3494
      @alexthehandyman3494 Před 19 dny

      @@alenbazarov3039 Maybe you just need a longer snake. You can rent one from Home Depot . Get a 5/16 or 3/8 50 or 70 ft.long. Is this the kitchen drain? How far from the main? Usually the main is by where a toilet is? If this is a kitchen, this is a branch and eventually has to reach the main. Keep me posted. One more thing, Is this pipe 1 1/2 to 2 inch? If is bigger the snake might coil and not go all the distance.

  • @saintpete3573
    @saintpete3573 Před 20 dny

    Is this PCBA for GE SDT750SSF1SS?

    • @alexthehandyman3494
      @alexthehandyman3494 Před 19 dny

      Hello, I dont remember . The part number and my DW number is displayed at the beginning of the video.

  • @saintpete3573
    @saintpete3573 Před 20 dny

    The display froze My washer and I can’t get out of it. It started when daughter played water on the sink and the water from the garbage disposal back flush back into the washer and now it’s stuck displaying “bottle wash” mode and cannot get out of it no matter what I do. It will not reset. I believe my controller board is dead. Please let me know what you think.

  • @bpeterson81
    @bpeterson81 Před 21 dnem

    I live in the west suburbs of chicago and I have to be honest, for the first minute or so, i thought maybe this was my fence from the opposite side. haha. I have a 30 yr old fence that needs replacement and I've wondered if i could just remove the old footings and pour new. This video helps my confidence in that.

    • @alexthehandyman3494
      @alexthehandyman3494 Před 21 dnem

      Hello Peter, Maybe e this is your house. This is Wheaton. Im glad I could help.

  • @Braze-xxx
    @Braze-xxx Před 22 dny

    Thanks for all of the details that other videos didn't mention

  • @googleemail514
    @googleemail514 Před 22 dny

    Great video. Just one question: Make sure it spins freely? What part are you spinning? The camera is showing something not spinning? Is the pulley supposed to spin freely when the spring is connected giving it tension? I replaced the belt but when the spring of the pulley is connected it take effort to spin the pulley. Then the agitator is not working. I wonder if there is a connection but I can't see anything wrong with the installation of the belt.

    • @alexthehandyman3494
      @alexthehandyman3494 Před 21 dnem

      Hello, After I installed the belt I'm turning the belt clock wise and then I went counter clock wise. First the belt moved "freely". Then when I turned the other way the belt engaged on the helix and move the tub. When the transmission is shut. It will turn one side but not the other one. "So make sure it spins or turns freely" to make sure is ok. Hopefully that helps.

    • @googleemail514
      @googleemail514 Před 21 dnem

      @@alexthehandyman3494 Thank you so much for your response. Like all your videos it is very helpful. I watched all your videos I could find related to my washer's problem (no agitation after overload) and If you have time it would be great if you could make a final one showing a solution that it seems many are looking for when machine does not agitate. The final question is: Is the helix, the tension pulley or the transmission or? what does not allow the agitation? I posted a video showing the final point at which I am stuck: czcams.com/video/CYoatlrcbJk/video.html. -Thanks for all your videos! They are great!

  • @ImranShaikh-kl7mj
    @ImranShaikh-kl7mj Před 23 dny

    Nice informative video.

  • @jamalbenthall151
    @jamalbenthall151 Před 24 dny

    Great video

  • @tms2568
    @tms2568 Před 24 dny

    What was that gray material under the toilet? Leveling cement? I just installed a Champion with elongated bowl. It rocks a little due to floor not being perfectly level front to back. I think a shim or some caulking like the directions say may help. But I saw you had that stuff under before installing and wondered what it was. Thanks for the video!

    • @alexthehandyman3494
      @alexthehandyman3494 Před 23 dny

      Hello, yes. it was cement. The toilet had a leak for a long time and destroyed the floor around the flange. So I repaired it before I installed the new toilet. If your toilet rocks a little bit and your floor is kind of ok you can shim it. Any hardware store sales toilet plastic shims. www.homedepot.com/p/Everbilt-Plastic-Toilet-Shims-4-Pack-88523/205172157?source=shoppingads&locale=en-US&pla&mtc=SHOPPING-BF-CDP-GGL-D26P-026_007_PLUMB_REPAIR-NA-NA-NA-PMAX-NA-NA-NA-NA-NBR-NA-NA-NEW-PMax&cm_mmc=SHOPPING-BF-CDP-GGL-D26P-026_007_PLUMB_REPAIR-NA-NA-NA-PMAX-NA-NA-NA-NA-NBR-NA-NA-NEW-PMax-71700000097492033--&gad_source=1&gclid=CjwKCAjwuJ2xBhA3EiwAMVjkVP9OV6nBKhvSj4sYHM8caqnzzNNyI_6cAyDW0x2OAHXtd0X2DoT6yRoCpecQAvD_BwE&gclsrc=aw.ds

  • @bitshred
    @bitshred Před 24 dny

    I'm confused as to why the concrete looks like a tube. When I built a fence my holes were dug out into a bell like shape, I set my posts and then the concrete went around them. So if you ever tried to dig them out the post would be encased in concrete.

    • @alexthehandyman3494
      @alexthehandyman3494 Před 23 dny

      Hello, that's because the installer used a narrow post digger . The hole is not that big and the cement surrounds the post just a couple inches all the way around.www.homedepot.com/p/Anvil-47-in-L-Wood-Handle-Steel-Post-Hole-Digger-77568-948/313597426?source=shoppingads&locale=en-US&pla&mtc=SHOPPING-BF-CDP-GGL-D28I-028_011_TOOLS-NA-NA-NA-PMAX-NA-NA-NA-NA-NBR-NA-NA-NA-PMAX&cm_mmc=SHOPPING-BF-CDP-GGL-D28I-028_011_TOOLS-NA-NA-NA-PMAX-NA-NA-NA-NA-NBR-NA-NA-NA-PMAX-71700000112731967--&gad_source=1&gclid=CjwKCAjwuJ2xBhA3EiwAMVjkVIB8BMT2wwTr7MMtYKmqLmy85GEe9U5X59Ok8LyRFjgRjDLn04igAhoCZL0QAvD_BwE&gclsrc=aw.ds

  • @solatope11
    @solatope11 Před 24 dny

    What is the link to buy the quiet check valve?