Julius Salutan
Julius Salutan
  • 30
  • 153 132

Video

Protection Relay Setting Calculation for MV Incoming Feeder Source B2 | Part 8 of 8
zhlédnutí 515Před rokem
Relay setting calculation for 51, 51N, 59 and 27 relays.
Protection Relay Setting Calculation for MV Bus Coupler with Directional Relay | Part 6 of 8
zhlédnutí 498Před rokem
Relay setting calculation for 51, 67, 67N, 59 and 27 relays.
Protection Relay Setting Calculation for MV Incoming Feeder Source B1 | Part 7 of 8
zhlédnutí 540Před rokem
Relay setting calculation for 51, 51N, 59 and 27 relays.
Protection Relay Setting Calculation for MV Cross Tie Feeders with Directional Relay | Part 5 of 8
zhlédnutí 445Před rokem
Relay setting calculation for 51, 67, 67N, 59 and 27 relays.
Protection Relay Setting Calculation for MV Incoming Feeder Source A1 & A2 | Part 4 of 8
zhlédnutí 525Před rokem
Relay setting calculation for 51, 51N, 59, and 27 relays.
Protection Relay Setting Calculation for MV Bus Coupler Upstream | Part 3 of 8
zhlédnutí 574Před rokem
Relay setting calculation for 51, 51N, 59, 27 relays.
Protection Relay Setting Calculation for MV Outgoing Cable Feeder | Part 2 of 8
zhlédnutí 826Před rokem
Relay setting calculation for 51, 51N, 59 and 27 relays.
Protection Relay Setting Calculation for MV Bus Coupler Downstream | Part 1 of 8
zhlédnutí 1,1KPřed rokem
Relay setting calculation for 51, 51N, 59 and 27 relays
Protection Relay Setting Calculation for MV Capacitor Bank Feeder
zhlédnutí 1,5KPřed rokem
Relay setting calculation for 51, 51N and 27 relays.
Protection Relay Setting Calculation for Transformer Feeder (Iow set, high set & instantaneous)
zhlédnutí 4,9KPřed rokem
Relay setting calculation for 51, 51N and 27 relays.
Arc Flash Analysis Using ETAP
zhlédnutí 9KPřed rokem
Performed Arc Flash Analysis using two different methods, i.e. IEEE 1584-2002 and IEEE 1584-2018.
How to Prepare a Key Single Line Diagram (SLD)
zhlédnutí 1,6KPřed rokem
Discussed on what are the information required in preparing a Key Single Line Diagram
Relay Coordination Study Using ETAP | Part 2
zhlédnutí 5KPřed rokem
Phase element coordination between downstream LV circuit breakers and upstream MV circuit breaker.
Relay Coordination Study Using ETAP | Part 1
zhlédnutí 19KPřed rokem
ANSI 51 relay phase element coordination study.
Usapang PEC | Article 6.95 Fire Pumps | Tagalog
zhlédnutí 4,2KPřed 2 lety
Usapang PEC | Article 6.95 Fire Pumps | Tagalog
Cable Sizing Using ETAP
zhlédnutí 7KPřed 2 lety
Cable Sizing Using ETAP
Protection Relay Setting Calculation for MV Motor Feeder Relays
zhlédnutí 9KPřed 2 lety
Protection Relay Setting Calculation for MV Motor Feeder Relays
Optimal Capacitor Placement and Capacitor Bank Sizing Using ETAP
zhlédnutí 4,2KPřed 2 lety
Optimal Capacitor Placement and Capacitor Bank Sizing Using ETAP
Protection Relay Setting Calculation for Transformer Feeder Relays
zhlédnutí 26KPřed 2 lety
Protection Relay Setting Calculation for Transformer Feeder Relays
Protection Relay Setting Calculation for Double Ended LV Switchgear Incomer Relays
zhlédnutí 5KPřed 2 lety
Protection Relay Setting Calculation for Double Ended LV Switchgear Incomer Relays
Harmonic Analysis and Harmonic Filter Sizing Using ETAP
zhlédnutí 6KPřed 2 lety
Harmonic Analysis and Harmonic Filter Sizing Using ETAP
Motor Starting Analysis Using ETAP - Dynamic
zhlédnutí 3,1KPřed 2 lety
Motor Starting Analysis Using ETAP - Dynamic
Motor Starting Analysis Using ETAP - Static
zhlédnutí 2,1KPřed 2 lety
Motor Starting Analysis Using ETAP - Static
Short Circuit Analysis Using ETAP Based on IEC 60909 Standard
zhlédnutí 4,5KPřed 2 lety
Short Circuit Analysis Using ETAP Based on IEC 60909 Standard
Short Circuit Analysis Using ETAP Based on ANSI C37 Standards
zhlédnutí 6KPřed 2 lety
Short Circuit Analysis Using ETAP Based on ANSI C37 Standards
How to Customize ETAP Library by Adding New Cable Data
zhlédnutí 6KPřed 2 lety
How to Customize ETAP Library by Adding New Cable Data
Cable Voltage Drop, Ckt. Breaker KAIC Rating and Busbar Bracing Verification Using ETAP
zhlédnutí 6KPřed 2 lety
Cable Voltage Drop, Ckt. Breaker KAIC Rating and Busbar Bracing Verification Using ETAP
Load Flow Study Using ETAP | Part 2
zhlédnutí 6KPřed 2 lety
Load Flow Study Using ETAP | Part 2
Load Flow Study Using ETAP | Part 1
zhlédnutí 10KPřed 2 lety
Load Flow Study Using ETAP | Part 1

Komentáře

  • @syedhaiderkhawarzmi6269

    can you share what setting you had for distribution pannels, HVCB and cables?

  • @syedhaiderkhawarzmi6269

    what are cable lengths?

  • @raymondgaballo7134
    @raymondgaballo7134 Před měsícem

    sir Juluis, dba grounding cable 1purpose will be for system ground. If the ground fault protection is disabled, is grounding cable ba still needed? Thank you

  • @sms150
    @sms150 Před měsícem

    Your video gave me confidence on Harmonics so that I can tackle clients. Thanks mate

  • @MJS146
    @MJS146 Před měsícem

    Sir I'm planning to take a whole training this coming nov. May I know how much usually is the amount of etap training? Based on the ff.topics 1. AC system modeling & cable sizing 1 & 2 2. Load flow study, evaluation, result analyzer review. 3. 3-D data base 4. Short circuit study and evaluation (ANSI & IEC) 5.Protective Device sequence and operation 6. Arc flash studies. Thank you

  • @user-mu2qu8uo4z
    @user-mu2qu8uo4z Před měsícem

    love it

  • @malcolmherojudge-bu5mm
    @malcolmherojudge-bu5mm Před měsícem

    Thank you for this video! I was having problems with my voltage drop on my cables using ETAP, and this video helped me see some options I believe I missed, great video!!

  • @phucnguyen-im7cj
    @phucnguyen-im7cj Před měsícem

    PLEASE GIVE ME THIS DOCUMENT

  • @user-mu2qu8uo4z
    @user-mu2qu8uo4z Před měsícem

    Thank you.

  • @jelesaraga3107
    @jelesaraga3107 Před měsícem

    salamat sir sa dagdag kaalaman, next vid sir sana po mga component na gngamit kapag jockey pump set up or with fire pump set up po. kagaya po nung nasa unang video mga piping diagram po.

  • @user-mu2qu8uo4z
    @user-mu2qu8uo4z Před měsícem

    one of the best overall lesson

  • @user-mu2qu8uo4z
    @user-mu2qu8uo4z Před 2 měsíci

    love it

  • @charinath5445
    @charinath5445 Před 2 měsíci

    Thank you for sharing your knowledge; I see some doing motor starting analysis in Transient stability module? why?

  • @subbancc
    @subbancc Před 2 měsíci

    Thank you very much.

  • @user-mu2qu8uo4z
    @user-mu2qu8uo4z Před 2 měsíci

    Love it

  • @Electrical_Engineering01abc

    Great video sir! By the way, can you also demonstrate on how to do Temperature Rise Analysis using ETAP? Thank you very much po.

  • @Electrical_Engineering01abc

    Sir Julius, How about if the transformer is ONAN/ONAF type? What rating will be considered in load flow analysis? Is it the ONAN or ONAF or both can be considered? Thank you very much po

  • @noelfaithfulkari2857
    @noelfaithfulkari2857 Před 3 měsíci

    Thanks sir, well explained. Subscribe to the channel

  • @recelalbertcelis8012
    @recelalbertcelis8012 Před 3 měsíci

    Sir good day. How to change units to mm squared sir instead of AWG/kcmil?

  • @pinoyguitartv
    @pinoyguitartv Před 3 měsíci

    Thanks sir 👍👍👍

  • @edwinloquina6693
    @edwinloquina6693 Před 4 měsíci

    Hi Sir, can you provide calculation and selection on CT and PT sizing.

  • @RedIBrown-mn9zs
    @RedIBrown-mn9zs Před 4 měsíci

    Thank you, Sir! Ask ko nalang din po if ever na nababago yung single tuned to double tuned? Tsaka RLC filter lang po ba or pwede po kaya ako makapag simulate ng LCL or LLCL filter? Thank you po in advance

  • @Doti_231
    @Doti_231 Před 4 měsíci

    Sir thank you for the videos, how you determine operating time T 0.50 second on the calculation for Relay 1??

  • @dha9jay
    @dha9jay Před 5 měsíci

    Please guide on input data of switchgear, bracing asymm rms and peak values.

  • @user-wq9fm2vg6r
    @user-wq9fm2vg6r Před 5 měsíci

    Thank you so much. So Helpful and informative

  • @alaadilekh4373
    @alaadilekh4373 Před 5 měsíci

    what is length of cable

  • @muhammadfajri5137
    @muhammadfajri5137 Před 5 měsíci

    Sorry Can i ask something. How to update library CB?

  • @9999afshin
    @9999afshin Před 5 měsíci

    Nice

  • @Elangelina
    @Elangelina Před 6 měsíci

    Thank you Lodi. Excellent videos

  • @garciabaptista3392
    @garciabaptista3392 Před 6 měsíci

    Could you please send me Tr. datesheet

  • @raju-by3nb
    @raju-by3nb Před 6 měsíci

    Sir please provide explanation on REF 615

  • @arbabimran388
    @arbabimran388 Před 6 měsíci

    Hello Salaam Peace be upon you Dear I checked it out your last video happened to uploaded an an year before. You technically have good content on ETAP and in Relays Why you are making vlogs on Relays especially and good vlogs to make model analysis on Etap. I encourage you to please continue your knowledge sharing on you tube. You have very good knowledge able skills Regard imran

  • @tuna6423
    @tuna6423 Před 6 měsíci

    Hi Julius, I am thinking that 24:15 Earth fault protection If it is set only 2 value i.e., threshold and definite time, it should be called as 50G not 51G Unless you select IDMT Characteristic e.g., NINV, VINV or EINV Normal/Very/Extremely Inverse respectively and set time multiplier this will be 51G

  • @jessiesantos1641
    @jessiesantos1641 Před 7 měsíci

    sir, papaano kung customer owned yung transformer or tawag natin sa pinas is owner supplied transfomer, allowed pa rin ba naka tap yung conductor sa secondary side ng transformer?

  • @syedbaqirrazakazmi5290
    @syedbaqirrazakazmi5290 Před 7 měsíci

    I am having this error "could not meet all minimum voltage limits. you may increase the number of capacitor banks or add more candidate buses and try again". Can you tell me how to fix it please?

  • @ASIFKHAN-ui7jp
    @ASIFKHAN-ui7jp Před 7 měsíci

    Excellent explanation. Thanks

  • @ASIFKHAN-ui7jp
    @ASIFKHAN-ui7jp Před 7 měsíci

    Very well explained thanks.

  • @diansyahkira7
    @diansyahkira7 Před 7 měsíci

    Thank you sir !!

  • @RaymundSanone
    @RaymundSanone Před 8 měsíci

    sir, can you also discuss how genset circuit breaker in synchronizing panel trip coordination done, condition genset circuit breaker has lower ampere rating compare to the feeder it will serve since 3 genset in parallel

  • @ivaylomanolov1455
    @ivaylomanolov1455 Před 8 měsíci

    Good job!

  • @michaelatef2051
    @michaelatef2051 Před 9 měsíci

    Hi , how i can show the data of cables on sld as c.s.a and the length on sld in etap because it is hidden

  • @kentanilom
    @kentanilom Před 9 měsíci

    Thank you for sharing sir. Very informative. Do you have tutorial for plotting transformer damage curve and its equivalent protection. Thank you very much and more powers po!

  • @abdullahgul388
    @abdullahgul388 Před 9 měsíci

    Good job for your valuable information but please have a look to the vedeo quality as contents are visually not clear in this vedeo

  • @johnngigi5692
    @johnngigi5692 Před 9 měsíci

    😮

  • @AAEL2010
    @AAEL2010 Před 9 měsíci

    Thank you ❤

  • @richardemery6690
    @richardemery6690 Před 10 měsíci

    Very good clear presentation! 👍

  • @LongVu-kl3np
    @LongVu-kl3np Před 10 měsíci

    thanks for sharing , can you send me the PDF calculation?

  • @aungzaw2262
    @aungzaw2262 Před 10 měsíci

    Thank for sharing.

  • @mkhoirun918
    @mkhoirun918 Před 10 měsíci

    One Problem, for Dynamic, we shall input Moment of inertia WR2 ( kg m2). How to calculate Moment Inertia WR2 (kg-m2) in ETAP? Is there any standard to calculate WR2?. I found in IEC 60034-12, Table 4. External Moment of Inertia J ( kg m2) for each kW of motor. Is it same WR2 and J? J in IEC 60034-12. Mentioned as J=0.04P^0.9xp^2.5