This channel will provide tutorial videos related to electrical engineering principles and practices.This will also serve as a review center to engineering students and aspiring engineering graduates who are planning to take Philippine professional board examination. Mathematics (algebra, trigonometry, geometry, calculus, etc.), engineering sciences and allied subjects, and electrical engineering subjects are being planned to be taught in this channel.
Protection Setting Calculation for LV Motor with MCCB or EOCR Protection
Performed protection relay setting calculation of LV motor with different protection devices.
zhlédnutí: 1 096
Video
Protection Relay Setting Calculation for MV Incoming Feeder Source B2 | Part 8 of 8
zhlédnutí 515Před rokem
Relay setting calculation for 51, 51N, 59 and 27 relays.
Protection Relay Setting Calculation for MV Bus Coupler with Directional Relay | Part 6 of 8
zhlédnutí 498Před rokem
Relay setting calculation for 51, 67, 67N, 59 and 27 relays.
Protection Relay Setting Calculation for MV Incoming Feeder Source B1 | Part 7 of 8
zhlédnutí 540Před rokem
Relay setting calculation for 51, 51N, 59 and 27 relays.
Protection Relay Setting Calculation for MV Cross Tie Feeders with Directional Relay | Part 5 of 8
zhlédnutí 445Před rokem
Relay setting calculation for 51, 67, 67N, 59 and 27 relays.
Protection Relay Setting Calculation for MV Incoming Feeder Source A1 & A2 | Part 4 of 8
zhlédnutí 525Před rokem
Relay setting calculation for 51, 51N, 59, and 27 relays.
Protection Relay Setting Calculation for MV Bus Coupler Upstream | Part 3 of 8
zhlédnutí 574Před rokem
Relay setting calculation for 51, 51N, 59, 27 relays.
Protection Relay Setting Calculation for MV Outgoing Cable Feeder | Part 2 of 8
zhlédnutí 826Před rokem
Relay setting calculation for 51, 51N, 59 and 27 relays.
Protection Relay Setting Calculation for MV Bus Coupler Downstream | Part 1 of 8
zhlédnutí 1,1KPřed rokem
Relay setting calculation for 51, 51N, 59 and 27 relays
Protection Relay Setting Calculation for MV Capacitor Bank Feeder
zhlédnutí 1,5KPřed rokem
Relay setting calculation for 51, 51N and 27 relays.
Protection Relay Setting Calculation for Transformer Feeder (Iow set, high set & instantaneous)
zhlédnutí 4,9KPřed rokem
Relay setting calculation for 51, 51N and 27 relays.
Arc Flash Analysis Using ETAP
zhlédnutí 9KPřed rokem
Performed Arc Flash Analysis using two different methods, i.e. IEEE 1584-2002 and IEEE 1584-2018.
How to Prepare a Key Single Line Diagram (SLD)
zhlédnutí 1,6KPřed rokem
Discussed on what are the information required in preparing a Key Single Line Diagram
Relay Coordination Study Using ETAP | Part 2
zhlédnutí 5KPřed rokem
Phase element coordination between downstream LV circuit breakers and upstream MV circuit breaker.
Relay Coordination Study Using ETAP | Part 1
zhlédnutí 19KPřed rokem
ANSI 51 relay phase element coordination study.
Usapang PEC | Article 6.95 Fire Pumps | Tagalog
zhlédnutí 4,2KPřed 2 lety
Usapang PEC | Article 6.95 Fire Pumps | Tagalog
Protection Relay Setting Calculation for MV Motor Feeder Relays
zhlédnutí 9KPřed 2 lety
Protection Relay Setting Calculation for MV Motor Feeder Relays
Optimal Capacitor Placement and Capacitor Bank Sizing Using ETAP
zhlédnutí 4,2KPřed 2 lety
Optimal Capacitor Placement and Capacitor Bank Sizing Using ETAP
Protection Relay Setting Calculation for Transformer Feeder Relays
zhlédnutí 26KPřed 2 lety
Protection Relay Setting Calculation for Transformer Feeder Relays
Protection Relay Setting Calculation for Double Ended LV Switchgear Incomer Relays
zhlédnutí 5KPřed 2 lety
Protection Relay Setting Calculation for Double Ended LV Switchgear Incomer Relays
Harmonic Analysis and Harmonic Filter Sizing Using ETAP
zhlédnutí 6KPřed 2 lety
Harmonic Analysis and Harmonic Filter Sizing Using ETAP
Motor Starting Analysis Using ETAP - Dynamic
zhlédnutí 3,1KPřed 2 lety
Motor Starting Analysis Using ETAP - Dynamic
Motor Starting Analysis Using ETAP - Static
zhlédnutí 2,1KPřed 2 lety
Motor Starting Analysis Using ETAP - Static
Short Circuit Analysis Using ETAP Based on IEC 60909 Standard
zhlédnutí 4,5KPřed 2 lety
Short Circuit Analysis Using ETAP Based on IEC 60909 Standard
Short Circuit Analysis Using ETAP Based on ANSI C37 Standards
zhlédnutí 6KPřed 2 lety
Short Circuit Analysis Using ETAP Based on ANSI C37 Standards
How to Customize ETAP Library by Adding New Cable Data
zhlédnutí 6KPřed 2 lety
How to Customize ETAP Library by Adding New Cable Data
Cable Voltage Drop, Ckt. Breaker KAIC Rating and Busbar Bracing Verification Using ETAP
zhlédnutí 6KPřed 2 lety
Cable Voltage Drop, Ckt. Breaker KAIC Rating and Busbar Bracing Verification Using ETAP
can you share what setting you had for distribution pannels, HVCB and cables?
what are cable lengths?
sir Juluis, dba grounding cable 1purpose will be for system ground. If the ground fault protection is disabled, is grounding cable ba still needed? Thank you
Your video gave me confidence on Harmonics so that I can tackle clients. Thanks mate
Sir I'm planning to take a whole training this coming nov. May I know how much usually is the amount of etap training? Based on the ff.topics 1. AC system modeling & cable sizing 1 & 2 2. Load flow study, evaluation, result analyzer review. 3. 3-D data base 4. Short circuit study and evaluation (ANSI & IEC) 5.Protective Device sequence and operation 6. Arc flash studies. Thank you
love it
Thank you for this video! I was having problems with my voltage drop on my cables using ETAP, and this video helped me see some options I believe I missed, great video!!
PLEASE GIVE ME THIS DOCUMENT
Thank you.
salamat sir sa dagdag kaalaman, next vid sir sana po mga component na gngamit kapag jockey pump set up or with fire pump set up po. kagaya po nung nasa unang video mga piping diagram po.
one of the best overall lesson
love it
Thank you for sharing your knowledge; I see some doing motor starting analysis in Transient stability module? why?
Thank you very much.
Love it
Great video sir! By the way, can you also demonstrate on how to do Temperature Rise Analysis using ETAP? Thank you very much po.
Sir Julius, How about if the transformer is ONAN/ONAF type? What rating will be considered in load flow analysis? Is it the ONAN or ONAF or both can be considered? Thank you very much po
Thanks sir, well explained. Subscribe to the channel
Sir good day. How to change units to mm squared sir instead of AWG/kcmil?
Thanks sir 👍👍👍
Hi Sir, can you provide calculation and selection on CT and PT sizing.
Thank you, Sir! Ask ko nalang din po if ever na nababago yung single tuned to double tuned? Tsaka RLC filter lang po ba or pwede po kaya ako makapag simulate ng LCL or LLCL filter? Thank you po in advance
Sir thank you for the videos, how you determine operating time T 0.50 second on the calculation for Relay 1??
Please guide on input data of switchgear, bracing asymm rms and peak values.
Thank you so much. So Helpful and informative
what is length of cable
Sorry Can i ask something. How to update library CB?
Nice
Thank you Lodi. Excellent videos
Could you please send me Tr. datesheet
Sir please provide explanation on REF 615
Hello Salaam Peace be upon you Dear I checked it out your last video happened to uploaded an an year before. You technically have good content on ETAP and in Relays Why you are making vlogs on Relays especially and good vlogs to make model analysis on Etap. I encourage you to please continue your knowledge sharing on you tube. You have very good knowledge able skills Regard imran
Hi Julius, I am thinking that 24:15 Earth fault protection If it is set only 2 value i.e., threshold and definite time, it should be called as 50G not 51G Unless you select IDMT Characteristic e.g., NINV, VINV or EINV Normal/Very/Extremely Inverse respectively and set time multiplier this will be 51G
sir, papaano kung customer owned yung transformer or tawag natin sa pinas is owner supplied transfomer, allowed pa rin ba naka tap yung conductor sa secondary side ng transformer?
I am having this error "could not meet all minimum voltage limits. you may increase the number of capacitor banks or add more candidate buses and try again". Can you tell me how to fix it please?
Excellent explanation. Thanks
Very well explained thanks.
Thank you sir !!
sir, can you also discuss how genset circuit breaker in synchronizing panel trip coordination done, condition genset circuit breaker has lower ampere rating compare to the feeder it will serve since 3 genset in parallel
Good job!
Hi , how i can show the data of cables on sld as c.s.a and the length on sld in etap because it is hidden
Thank you for sharing sir. Very informative. Do you have tutorial for plotting transformer damage curve and its equivalent protection. Thank you very much and more powers po!
Good job for your valuable information but please have a look to the vedeo quality as contents are visually not clear in this vedeo
😮
Thank you ❤
Very good clear presentation! 👍
thanks for sharing , can you send me the PDF calculation?
Thank for sharing.
One Problem, for Dynamic, we shall input Moment of inertia WR2 ( kg m2). How to calculate Moment Inertia WR2 (kg-m2) in ETAP? Is there any standard to calculate WR2?. I found in IEC 60034-12, Table 4. External Moment of Inertia J ( kg m2) for each kW of motor. Is it same WR2 and J? J in IEC 60034-12. Mentioned as J=0.04P^0.9xp^2.5