North West Gas Certificates
North West Gas Certificates
  • 186
  • 903 977

Video

How to lower the pressure on a Ideal combi boiler
zhlédnutí 115Před 14 dny
Video showing you how to lower the pressure on this Ideal Logic combi boiler.
Biasi Combi boiler. No heating
zhlédnutí 90Před 21 dnem
This Biasi or Caradon Ideal combi boiler gave me some problems and ended up being something simple. There was no heating but hot water was working.
Viessmann Vitodens 100-W. Heat only boiler. High and Low service modes.
zhlédnutí 171Před měsícem
For fellow gas engineers and a reminder to myself. How to put this heat only boiler into service mode.
Worcester Bosch CDI Classic. Re pressurising the expansion vessel using the filter
zhlédnutí 228Před 2 měsíci
Re pressurising the expansion vessel on this Worcester Bosch Greenstar CDI Classic 29KW. This is only to be done by gas safe engineers
Vaillant EcoTec Plus 937. Flue adapter removal and heat exchanger seal replaced
zhlédnutí 160Před 2 měsíci
I've already posted a couple of videos replacing the seal on the top of the heat exchanger. However on this particular model the removal of the flue adapter proved tricky due to its different design. I therefore decided to post. Only for qualified gas safe registered engineers.
Worcester Bosch Greenstar 8000 Condensate trap clean
zhlédnutí 372Před 3 měsíci
Worcester Bosch Greenstar 8000 Condensate trap clean
New radiator install
zhlédnutí 240Před 3 měsíci
New radiator install
Ferroli Optimax 25C. Boiler repair
zhlédnutí 136Před 3 měsíci
Ferroli Optimax 25C. Boiler repair
How to adjust the minimum flame on a hob from going out
zhlédnutí 560Před 4 měsíci
How to adjust the minimum flame on a hob from going out
Vokera combi boiler. Blocked heat exchanger. Full service.
zhlédnutí 2,1KPřed 5 měsíci
Vokera combi boiler. Blocked heat exchanger. Full service.
Bleeding your radiators. For the customer.
zhlédnutí 157Před 5 měsíci
Bleeding your radiators. For the customer.
Toilet repair. DIY.
zhlédnutí 109Před 5 měsíci
Toilet repair. DIY.
Vaillant Ecotec Pro. F75 Fault
zhlédnutí 927Před 6 měsíci
Vaillant Ecotec Pro. F75 Fault
I just purchased a Rothenberger toilet unblocker for £130?? Was it worth it 🤔
zhlédnutí 615Před 6 měsíci
I just purchased a Rothenberger toilet unblocker for £130?? Was it worth it 🤔
Removing radiator cover for customer. Chimney Pot Park in Salford
zhlédnutí 127Před 6 měsíci
Removing radiator cover for customer. Chimney Pot Park in Salford
Toilet repair. New Internal flushcone
zhlédnutí 403Před 6 měsíci
Toilet repair. New Internal flushcone
Vaillant EcoTec Plus. New diverter valve
zhlédnutí 2,1KPřed 7 měsíci
Vaillant EcoTec Plus. New diverter valve
New Ideal Logic combi boiler fails a gas safety certificate
zhlédnutí 540Před 7 měsíci
New Ideal Logic combi boiler fails a gas safety certificate
Ariston Clas One Combi boiler. High and low service modes
zhlédnutí 11KPřed 7 měsíci
Ariston Clas One Combi boiler. High and low service modes
Gas leak ID. I smelt gas when I arrived but it passed the tightness test
zhlédnutí 792Před 8 měsíci
Gas leak ID. I smelt gas when I arrived but it passed the tightness test
Ideal Combi boiler wont go into low service mode. Be patient, its an Ideal tweak!
zhlédnutí 247Před 8 měsíci
Ideal Combi boiler wont go into low service mode. Be patient, its an Ideal tweak!
Ideal Logic Plus Combi Boiler fails landlord gas safety certificate
zhlédnutí 1,2KPřed 8 měsíci
Ideal Logic Plus Combi Boiler fails landlord gas safety certificate
Alpha E Tec Plus NX. High and Low Service Mode.
zhlédnutí 898Před 8 měsíci
Alpha E Tec Plus NX. High and Low Service Mode.
How to replace a thermostatic shower?? DIY
zhlédnutí 101Před 8 měsíci
How to replace a thermostatic shower?? DIY
Vaillant Ecotec Pro 28. Repressurising the expansion vessel
zhlédnutí 12KPřed 9 měsíci
Vaillant Ecotec Pro 28. Repressurising the expansion vessel
Ferroli Optimax 25C Boiler Repair. No hot water or heating
zhlédnutí 1,4KPřed 9 měsíci
Ferroli Optimax 25C Boiler Repair. No hot water or heating
Sentinel X100 Inhibitor Rapid Dose. How to use???
zhlédnutí 3,1KPřed 11 měsíci
Sentinel X100 Inhibitor Rapid Dose. How to use???
Baxi 600 repair. No heating or hot water
zhlédnutí 1,6KPřed rokem
Baxi 600 repair. No heating or hot water
Don't repressurise the expansion vessel without them
zhlédnutí 1,4KPřed rokem
Don't repressurise the expansion vessel without them

Komentáře

  • @davidnjoroge5576
    @davidnjoroge5576 Před 3 hodinami

    Does oil work

  • @Noname4now2025
    @Noname4now2025 Před 11 hodinami

    If i press - and + together what s happend?

    • @northwestgascertificates
      @northwestgascertificates Před 5 hodinami

      It states it will go into chimney sweep mode. However in the manufactures instructions and whenever I've been with a Vaillant service engineer, they always use the P.01 test mode to put it into high service mode. Therefore i have always done that as well...

    • @Noname4now2025
      @Noname4now2025 Před 5 hodinami

      @@northwestgascertificates the temperature raise instantly...IT îs problem?

    • @northwestgascertificates
      @northwestgascertificates Před 4 hodinami

      @@Noname4now2025 hello. Yes do not press these together. This is just for a gas engineer to do

  • @jessm9274
    @jessm9274 Před 2 dny

    Were getting an E1 errors on this boiler. No drop in pressure though still at 2 bars? Generally if i reset the boiler it seems to start working, but then itll go again a day or so later

    • @northwestgascertificates
      @northwestgascertificates Před dnem

      Check the pressure guage needle isn't stuck on 2 bar. Does it go up when the heating is put on. The pressure sensor inside the boiler maybe at fault as it is this that will generate the E1 code if the pressure is to low not the actual dial on the front of the boiler...

  • @dr.sravanthysunder941

    I sawbyour video and fixed fire alarm batteries.thanks a ton

  • @adreenryan2901
    @adreenryan2901 Před 5 dny

    Would high pressure stop the boiler from running.

    • @northwestgascertificates
      @northwestgascertificates Před 5 dny

      If the pressure ever goes over 3 bar, the pressure relief valve opens up and then often needs replacing. You don't want that. If the pressure starts cold at 2 bar, when the radiators start to heat up, the water in them expands and the pressure will always go up and there is a chance it could reach 3 bar...

  • @chumber05
    @chumber05 Před 7 dny

    Thank you for video

  • @CommercialGasEngineerVideos

    Nice one NWGC

  • @rashtheplumber
    @rashtheplumber Před 8 dny

    Is that an opening within 300mm of flue outlet?

    • @northwestgascertificates
      @northwestgascertificates Před 7 dny

      I think its just a mark on it. Ive re watched but can't really tell to be honest. I didn't notice it at the time...

  • @bikusmoto59
    @bikusmoto59 Před 12 dny

    That's a deep bath trap. In what circumstances would a shallow bath trap be used?

    • @northwestgascertificates
      @northwestgascertificates Před 11 dny

      Only if a deep one was going to hit the floor below. Often there isn't a lot of room so a shallow one is needed 👍

  • @bikusmoto59
    @bikusmoto59 Před 12 dny

    Can you use Plumber's Mate instead of ghastly smelly silicone?

  • @bamaketsemochedisi6062

    🎉

  • @Arsenal-81
    @Arsenal-81 Před 12 dny

    it works, thats the main thing 😂

  • @paulyoung6165
    @paulyoung6165 Před 16 dny

    How do you change the boiler set up from Nat Gas to LNPG once the adaptor kit has been fitted and installation is completed. thanks

  • @kirren7255
    @kirren7255 Před měsícem

    Top tip 👍🏻

  • @madmaycon2531
    @madmaycon2531 Před měsícem

    😮😮😮😮😮

  • @Primexelite8680
    @Primexelite8680 Před měsícem

    I love viessmann.. rinnia = 20 torq screws for simple diagnostics + random chinese letters lol. Germany has been the innovativers of plumbing for a while.

  • @bobnoxious1983
    @bobnoxious1983 Před měsícem

    Top man. Great explanation 👍

  • @STEVES7EVE
    @STEVES7EVE Před měsícem

    When it's your first day on the job and you realise there's a tool for everything

  • @quratulainmalikquilling9864

    Thankyou so much was cleaning with tooth pick gas was not coming through

  • @aliderisi8656
    @aliderisi8656 Před měsícem

    You didnt say turn the radiator off

  • @goffyglos5675
    @goffyglos5675 Před měsícem

    Try a grill..

  • @jasonowen8000
    @jasonowen8000 Před měsícem

    Why take vessel out ? Just replace top, unscrew the top clean the body no need to take the whole brass part out 2min job

  • @madmaycon2531
    @madmaycon2531 Před měsícem

    😅😅😅Proper Job!!!😂😂😂😂

  • @kennydaniels6285
    @kennydaniels6285 Před měsícem

    My bath is leaking and you have given me the confidence to tackle it in my own, brilliant video mate and well explained, thanks 👍👍

  • @TheDickPuller
    @TheDickPuller Před měsícem

    Using Coke or Irn Bru is great for cleaning the HX, but you do need to flush it with water after, a good flush!! The Vokera Easiheat is a great wee budget boiler👍👍👍 We look after about 150 here in the West of Scotland. They do need a ‘strip down’ service every couple of years. You also must clean the Condy Trap & Check the Co2, adjust as required. Wee Tip; When don’t your Hi & Lo tests on these. Run the HW & remove the Diverter Valve Actuator. The boiler will remain fired up even on the smallest systems.👍👍👍

  • @aivarasc7525
    @aivarasc7525 Před měsícem

    What there is no pipe like that or taps like that?

    • @northwestgascertificates
      @northwestgascertificates Před měsícem

      A lot of times the taps are under the boiler on the vokera. It will be 2 little taps

  • @mrt227zxr
    @mrt227zxr Před měsícem

    Horrible boilers

  • @rjkelectrical6086
    @rjkelectrical6086 Před měsícem

    Could you not of wired a 3 core and earth, And wire Live supply of the boiler terminal to the live terminal of the receiver then linked L and 1 together in receiver Then from 3 of the receiver to the switch live return To boiler?

    • @northwestgascertificates
      @northwestgascertificates Před měsícem

      Im unsure. The other end of that 5 core literally joined the live, neutral and earth at the boiler supply. Then the normally open and common went where the link wire originally was in the boiler. Im not going to lie, i need more education when it comes to electrics...

  • @zaczac3024
    @zaczac3024 Před měsícem

    Built in thermistor in heat exchanger, cannot be replaced When this $5 part fails the boiler is scrap, guess how I know this 😂

    • @northwestgascertificates
      @northwestgascertificates Před měsícem

      I don't know but Alpha have the same problem. If the flue thermistor goes it is also a new main heat exchanger 🤦‍♂️

  • @CommercialGasEngineerVideos

    Bumped into one of these recently and was wondering about hi and lo. Nice one

  • @rigel8755
    @rigel8755 Před měsícem

    Didn't need to go so hard on the soundtrack bro, DJ Shadow is just for special occasions :)

  • @leonapater6071
    @leonapater6071 Před 2 měsíci

    You helped me a lot

  • @victorvacari6884
    @victorvacari6884 Před 2 měsíci

    Hi, I've got CFS message and beeping every 10 mins, i know its due for service, howevere can i meantime to get rid of this mesaage? Thanks.

    • @northwestgascertificates
      @northwestgascertificates Před 2 měsíci

      Hi. I had the same and phoned Vokera. They talked me through removing this. It was pretty complicated and i wish i had captured it all on a video. You will have to phone them im afraid 👍

  • @zxcherry7356
    @zxcherry7356 Před 2 měsíci

    How do u get it on low fire

    • @northwestgascertificates
      @northwestgascertificates Před 2 měsíci

      Same as high fire but you turn either the water temperature control knob right down or the radiator temperature control knob right down 👍

    • @zxcherry7356
      @zxcherry7356 Před 2 měsíci

      @@northwestgascertificates 👍👍

  • @user-hm9fg6jl8t
    @user-hm9fg6jl8t Před 2 měsíci

    Thanks for the video. I had the same one. No display fan running constantly. Called ideal they said PCB. But the customer wanted a new boiler instead as they have spent lots on it already.

  • @brahimaitoukharaz3039
    @brahimaitoukharaz3039 Před 2 měsíci

    hello, I have a vaillant ecotec plus vcw 356 3-5 boiler that works with natural gas and I would like to run it with propane gas. Sincerely

    • @northwestgascertificates
      @northwestgascertificates Před 2 měsíci

      You will need to buy a conversion kit to change from natural gas to lpg. Propane i am not sure. I would ask Vaillant technical about that 👍

  • @ElectricRootz
    @ElectricRootz Před 2 měsíci

    Mine doesn't reset when I do this. It keeps going back to A01. There is a 💧 symbol with an x going through it. No flame either. It's doing my head in. I've had a couple of plumbers to check it out and none of them can seem to fix it.

    • @northwestgascertificates
      @northwestgascertificates Před 2 měsíci

      Sometimes it works out cheaper to just call out Vokera. They will do a one price fix all deal. Its guaranteed to be sorted...

  • @raj080288
    @raj080288 Před 2 měsíci

    Hi, do we have to release any air that is left in the schrader valve before we replace it?

    • @northwestgascertificates
      @northwestgascertificates Před 2 měsíci

      No. As you start removing the Schrader valve any air will come out anyway..

    • @raj080288
      @raj080288 Před 2 měsíci

      @@northwestgascertificates thanks mate

  • @perryplacey9318
    @perryplacey9318 Před 2 měsíci

    Thanks always have to come back to this video 😅

  • @raj080288
    @raj080288 Před 3 měsíci

    Great video. What is that spray called you sprayed on the valve to check for leaks?

    • @northwestgascertificates
      @northwestgascertificates Před 3 měsíci

      It is rothenberger leak detection fluid. You can use a bit of fairy liquid though as well...

    • @raj080288
      @raj080288 Před 3 měsíci

      Diluted fairy liquid or pure?

    • @northwestgascertificates
      @northwestgascertificates Před 3 měsíci

      Diluted. Just to make sure it is not letting any air out. It will bubble a bit if it is leaking..

    • @raj080288
      @raj080288 Před 3 měsíci

      ​@@northwestgascertificates thank you so much, appreciate the prompt response

  • @amansukoon
    @amansukoon Před 3 měsíci

    How can i put timings for heating to turn on on specific times?

    • @northwestgascertificates
      @northwestgascertificates Před 3 měsíci

      You need to wire in an external thermostat. I have done another video on that 👍

  • @userscott
    @userscott Před 3 měsíci

    Thank you. This was exactly what I needed - spent about an hour on it. 😂

  • @christophergould4013
    @christophergould4013 Před 3 měsíci

    I found this very useful as I have just had a new boiler fitted with this very problem so will investigate thanks

  • @jamesjulian
    @jamesjulian Před 3 měsíci

    That’s why I don’t do safety checks for landlords, I would identify all the same fault and would be the same the following year as they wouldn’t pay to put it right. Race to the bottom. Good short!

  • @jameswilson2899
    @jameswilson2899 Před 3 měsíci

    Great help mate, I find some condensing traps a pain to get in and out. Few more when you have time please

  • @ginola602
    @ginola602 Před 3 měsíci

    The lock shield cap is class,what sort of Muppet does that?

  • @SparkTech0
    @SparkTech0 Před 3 měsíci

    Thanks mate… this just helped me now

  • @pianorags
    @pianorags Před 3 měsíci

    When i turn both valves nothing happens

    • @northwestgascertificates
      @northwestgascertificates Před 3 měsíci

      Make sure the little copper connecting pipe that you see in my video is in place. On rare occasions someone has removed this and there are caps in its place. The boiler would not fill without this in place. Also if you have low water pressure in your house, the filling can be very slow and you have to be patient...

    • @monkeychu420
      @monkeychu420 Před 3 měsíci

      FKN SAAAME

  • @laheart1957
    @laheart1957 Před 3 měsíci

    What is the tool that you used to remove the hob?

  • @Woopbot2
    @Woopbot2 Před 3 měsíci

    Mines 4.5 volts... Still F1 low pressure code. Any ideas?

    • @northwestgascertificates
      @northwestgascertificates Před 3 měsíci

      I would change the pressure sensor. It thinks the pressure is 4.5 bars. As long as you know the pressure isn't that which is off the scale on the gauge, then i would change it, its faulty..