Sentinel X100 Inhibitor Rapid Dose. How to use???

Sdílet
Vložit
  • čas přidán 5. 09. 2024
  • How to dose a central heating system using sentinel X100 Rapid Dose Central Heating Scale Inhibitor

Komentáře • 5

  • @user-mm8kh5he3f
    @user-mm8kh5he3f Před 8 měsíci +5

    You did that wrong - ur supposed to open rad valve before you dose and attach the can - the bullet in the can prevents the system pressure forcing water out the tube - attach the can and its dosed in a few secs. Remove can from tube . Shutand the bullet acts as a NR valve. Shut rad valves and reattach bleed screw - or the whole nipple as u removed. Way you did it with valves closed meant you put a lot of pressure into a small space rather than spreading it through the system which is why you got a problem trying to remove tube. Do that in a smaller rad and it won't all go in or might even blow the tube out.

    • @alfonsode_beckwith7209
      @alfonsode_beckwith7209 Před 3 dny

      That's what I thought, so I came to the comments to check. Thanks for your comment.

  • @aliderisi8656
    @aliderisi8656 Před 3 měsíci +1

    You didnt say turn the radiator off

  • @paulrossiter9567
    @paulrossiter9567 Před rokem +1

    Nice vid …It’s never nice adding inhibitors to those rads 🤦🏼‍♂️ gimme a towel rad any day haha. 🎉