EV fundamentals #5: Field Weakening

Sdílet
Vložit
  • čas přidán 23. 11. 2022
  • In this video I go over the implementation of field weakening. It is needed to run permanent magnet motors above their base speed.
    Simulator: github.com/Pete9008/IPMMotorSim
    Thread about it: openinverter.org/forum/viewto...
    Finding Critical current: openinverter.org/forum/viewto...
    Finding flux linkage: openinverter.org/forum/viewto...
    Support on Patreon: / openinverter
    Shop: openinverter.org/shop
    Forum: openinverter.org/forum
    Watch adfree on Odysee: odysee.com/@openinverter:9
  • Věda a technologie

Komentáře • 9

  • @davefiddes
    @davefiddes Před rokem

    Congratulations to you and Pete for getting to the bottom of this. The video is a very helpful summary of what you've been up to and is a lot easier to understand than the thread which was a bit much for my mechanical/software engineer brain to keep up with. Thanks.

  • @vika_papa
    @vika_papa Před 10 měsíci

    Thank you very much for this video, I really lacked understanding of these settings. We are waiting for openivertor to configure itself automatically. Thank you

  • @A2an
    @A2an Před rokem +1

    A lot of work, but satisfying to see it works.😊👍

    • @EngineersFear
      @EngineersFear  Před rokem

      Yes, the first (set of) successful test drive(s) (in both Prius and Leaf based cars) was very thrilling!

  • @bildmateria
    @bildmateria Před rokem +1

    Big respect for this effort for sure! I followed progress of course in the forum and wondered how you can be sure the motor model behaves like a real motor. It worked in the end of course, but I assumed at some point you would need to spin a motor on the bench fast & with a load to provoke the error and tighten your think - deploy - test loop. Maybe this is something to ask Pete at some point!

    • @EngineersFear
      @EngineersFear  Před rokem +1

      Thanks!
      After going back and forth between simulated and real car and Pete making adjustments, we could see the two converge. A test bench with two motors would fill in the gap but is quite an expensive and room-taking endeavour

  • @mehmetcx
    @mehmetcx Před 9 měsíci

    Could you please teach us active short circuit, derating and limp pump mode?

    • @EngineersFear
      @EngineersFear  Před 9 měsíci

      Derating I could do, the other two I've never heard about. What's a limping pump and active short circuit?