    Harmonic current causes additional heating of the transformer and cabling to the VFD, which reduces the capacity of the cable and transformer. An ac line reactor or dc link reactor (dc choke) is used to mitigate the impact of harmonics in VFD applications

Komentáře • 102

  • @sanjayhake6872
    @sanjayhake6872 Před 18 dny +1

    Very nicely explained

    • @bishantkumar12589
      @bishantkumar12589  Před 18 dny

      Thank you so much sir 😊 kindly share the channel with your electrical team 🙏🏼

  • @trulyhumane1591
    @trulyhumane1591 Před 2 lety +1

    Thank you for making an informative video.

  • @papanbauri8954
    @papanbauri8954 Před 10 měsíci +1

    Great sir

    • @bishantkumar12589
      @bishantkumar12589  Před 10 měsíci

      Thank you so much sir. Kindly share this channel with your electrical team 🙏

  • @RiyazShaikh-yd3me
    @RiyazShaikh-yd3me Před rokem +1

    Nice

  • @yashwantchouhan340
    @yashwantchouhan340 Před rokem +1

    Thanks sir for this video
    🙏🙏🙏🙏

  • @srinivasulupeddapasupala2335

    Excellent video

  • @shubhammhatre179
    @shubhammhatre179 Před 2 lety +1

    knowledgeable information....👍👍👍👍👍👍

  • @SachinPatel-vx3yi
    @SachinPatel-vx3yi Před rokem +1

    Good information

  • @wasimsharif8242
    @wasimsharif8242 Před rokem +1

    Very best explanation bro

  • @vijithdavis9977
    @vijithdavis9977 Před 2 lety

    Sir iam not able to run an inverter ac on a 5kva sine wave inverter. Inverter transformer is vibrating even at 900 watts and the PF was 83. I had tested resistive load of more than 2000 watts on this inverter. is there anything to do with harmonics, since its an inverter ac which has vfd like thing? also kindly provide the solution. Thanks..

  • @Deepakranjan555
    @Deepakranjan555 Před 2 lety +1

    Nicely explained..drive mein sabko expert kar dijiye

  • @arjunthakur4762
    @arjunthakur4762 Před 3 lety

    Sir ht 3.3 kv capacitor ko hum direct 3 phase 70 kvar ka hai fuse thru vcb starter se on karte hai lekin fuse bar bar udta hai aur flash hota hai capacitor ki 3 phase bitwin meggar velue kitni honi chahia please iske bare me video banaia thanks

  • @digvijayrana8297
    @digvijayrana8297 Před rokem +1

    We have Siemens drive it's showing Contintinuty between R and Y phase in coming side of vfd

  • @digvijayrana8297
    @digvijayrana8297 Před rokem +1

    Can you telling me what is the reason when motor stat so input choke very noisy it's choke problem or any problem in vfd

    • @bishantkumar12589
      @bishantkumar12589  Před rokem

      Due to high inrush current at starting it happens. But most cases it should not happen.

  • @shoaibqureshi5114
    @shoaibqureshi5114 Před 2 lety +1

    Aj yehi pucha interview me ... thank you for the information 👍

  • @astronaut-x
    @astronaut-x Před rokem +1

    Sir anyone can tell me about fanuc amplifier function and working.
    I'm Thankful those guy who give some information about fanuc amplifier.

    • @bishantkumar12589
      @bishantkumar12589  Před rokem +1

      Sir. Presently we don't have this equipment here, hope in future I will arrange as suggested

  • @jaysinghyadav9112
    @jaysinghyadav9112 Před 3 lety +1

    Brake operate karne ke liye drive me konsa paramater feed karna padta hai

  • @omkarkumar5000
    @omkarkumar5000 Před 3 lety +1

    Very nice sir in easy way we can understand sir please detail video baniye ACS 800 ya AcS 1000

    • @bishantkumar12589
      @bishantkumar12589  Před 3 lety +1

      Okay sir

    • @omkarkumar5000
      @omkarkumar5000 Před 3 lety +1

      @@bishantkumar12589interview main kya kya pucha ja sakta hai wo point bhi btaye thank you so much for your valuable response

    • @bishantkumar12589
      @bishantkumar12589  Před 3 lety

      @@omkarkumar5000 sure sir. I'll make separate video on this topic. Thank u

  • @mohammadnehal7532
    @mohammadnehal7532 Před rokem +1

    We call input reactor out put reactor right

  • @mithunray6017
    @mithunray6017 Před 11 měsíci +1

    Vfd ka out put sinusoidal wave kaysa hota hai?

    • @bishantkumar12589
      @bishantkumar12589  Před 11 měsíci

      VFD ka main components hai IGBT wo input DC signal ko pulse width modulated sine wave signal me convert kar deta hai which is nearly perfect sinusoidal power waveform.

  • @nasiruddinhimu5075
    @nasiruddinhimu5075 Před 4 lety +1

    Dear sir thanks.... line filter or choke filter same device or different device ????

  • @sadaqatmehmood6204
    @sadaqatmehmood6204 Před rokem +1

    how to read the electrical diagram

    • @bishantkumar12589
      @bishantkumar12589  Před rokem

      Pl check my last video, it was on ELECTRICAL DOL Starter Drawing and next coming on VFD drawing soon

  • @mangeshpawar5308
    @mangeshpawar5308 Před 3 lety +3

    Sir plz upload more videos of Siemens drive plc panel

  • @anilbhogil4983
    @anilbhogil4983 Před 3 měsíci +1

    Hi sir,
    For electrical wiring work के लिए which cource is comfortable plz suggeste me..👏

    • @bishantkumar12589
      @bishantkumar12589  Před 3 měsíci

      Sir. Iska saahi idea mujhe nai hai. Aap CZcams se help le k dekho

  • @mithunray6017
    @mithunray6017 Před 11 měsíci +1

    Vfd operated motor me huming sound kiu ata hai ?

    • @bishantkumar12589
      @bishantkumar12589  Před 11 měsíci

      Maine practically esa observe nai kiya.
      Generally, Humming sound motor me single phasing k chalte aata h.
      VFD me humming sound may be high frequency me esa hone ka changes h because of the raising the switching frequencies.

  • @consoultechnical1688
    @consoultechnical1688 Před 3 lety +1

    Sir mujhe agar choke ko check karna hai ki vo thik hai ki nahin usko kaise check karoonga multimeter se

    • @bishantkumar12589
      @bishantkumar12589  Před 3 lety +1

      Choke, inductor hota hai, ar usko Multimeter se check karna h too uska resistance check kar sakte h. Teeno choke me same resistance hona chahiye

  • @avinashawasthi9268
    @avinashawasthi9268 Před 3 lety +1

    is there any book or may i have your no.

  • @arunchowdhury4366
    @arunchowdhury4366 Před 2 lety +1

    How to choose I/p choke rating sir?

  • @sumits_shetty
    @sumits_shetty Před 2 lety +1

    Hey bishant sir, Can i feed auxiliary supply to digital voltmeter via choke coil( 40watt) to prevent damaging from voltage surges?

  • @gokulaher2476
    @gokulaher2476 Před rokem +1

    Nice informative video
    What would be market price of
    5.5kw (7.5hp) Line reactor or line choke?

    • @bishantkumar12589
      @bishantkumar12589  Před rokem

      Which company's make line reactor you need ?

    • @gokulaher2476
      @gokulaher2476 Před rokem

      @@bishantkumar12589 which company is making good quality and reliable
      I am looking for that
      Kindly provide company and price details
      Thank you!💐

    • @gokulaher2476
      @gokulaher2476 Před rokem +1

      @@bishantkumar12589 can you pl. provide the information like
      which are the top 3 best line choke making company in India?
      And what would be the price of
      Line choker compatible to
      5.5kw 15amp, 7.5hp motor
      Thank you!

    • @bishantkumar12589
      @bishantkumar12589  Před rokem

      @@gokulaher2476 okay. I'll try. You are from ?

    • @bishantkumar12589
      @bishantkumar12589  Před rokem

      ABB is good choke as per my experience. I can arrange that for you.
      Send me the complete details on my mail - bishantkumar03@gmail.com

  • @vartagujarati
    @vartagujarati Před rokem +1

    What if capacitance effect becomes dominant?

    • @bishantkumar12589
      @bishantkumar12589  Před rokem

      Capacitance effect of ?? Power cable ?

    • @vartagujarati
      @vartagujarati Před rokem

      @@bishantkumar12589 if cables length are more than 300 m and we do not use output choke...what is the consequences?

  • @rc0342
    @rc0342 Před rokem +1

    Adha adhura Gyan..

  • @mdsaqibansari6713
    @mdsaqibansari6713 Před 3 lety +2

    Sir, i am design engineer in Dubai... I make this VFD panel nidec control technique 160kw(master) 120kw(follower) ...input reactor and output reactor filter....

    • @mdsaqibansari6713
      @mdsaqibansari6713 Před 3 lety

      give me about more info please... i need your no... to learn more ..

    • @ravijha2122
      @ravijha2122 Před 3 lety

      Can we discuss on vfd.. request you to give your contact details...

  • @avinashawasthi9268
    @avinashawasthi9268 Před 3 lety +1

    how can we design a choke

  • @pankajsanwal2010
    @pankajsanwal2010 Před rokem +1

    Choke की value कैसे calculate करोगे ???

    • @bishantkumar12589
      @bishantkumar12589  Před rokem +1

      czcams.com/video/RFyC1-aPI3w/video.html
      Aapke kaam aayega ye video

    • @pankajsanwal2010
      @pankajsanwal2010 Před rokem

      @@bishantkumar12589देखते हैं । आशा है आपका अनुमान सही होगा । 😀

  • @Maddyharyana3821
    @Maddyharyana3821 Před 3 lety

    E.M.C FILTER OR CHOKE SAME HOTE HAI SIR???

  • @swaroopmohanty963
    @swaroopmohanty963 Před 6 měsíci +1

    Sir non linear meaning

    • @bishantkumar12589
      @bishantkumar12589  Před 6 měsíci

      Devices in which current do not follow voltage eg - diodes scr etc

  • @brajkishorsingh4002
    @brajkishorsingh4002 Před 2 lety

    After 1 yr, i am here.

  • @vgautomation8759
    @vgautomation8759 Před 3 lety

    Sir please aap VFD ki drawing provide kr dijiye pdf me

  • @sanjaykumarbharvad1828
    @sanjaykumarbharvad1828 Před 4 lety +1

    Sir apaka nabar dijiy plz

  • @sumitjambhulkar8875
    @sumitjambhulkar8875 Před 4 lety

    Video quality bahut hi kharab hai. Sudhar karo.

  • @michaelmelling4277
    @michaelmelling4277 Před 2 lety

    HEY - If your video title is English then you should speak English!!

    • @bishantkumar12589
      @bishantkumar12589  Před 2 lety

      Ya true !!! But most of my viewer understand Hindi language much better than English.
      Still, if there's anything I could help you, I'll !!

    • @bishantkumar12589
      @bishantkumar12589  Před rokem

      Link for my Electrical Channel in English language - Can Subscribe for upcoming new videos there . Thank you ☺️
      czcams.com/video/vxtOQvs7U6I/video.html

  • @Deepakranjan555
    @Deepakranjan555 Před rokem +1

    Nice