Over The Top? DATA Cables In Domestic

Sdílet
Vložit
  • čas přidán 4. 07. 2024
  • Getting started on running power and data into the office. Unfortunately for me there is 29 data cables to run in this property.
    Get 10% off Rhino Trade Insurance using code BUNDY10 at www.rhinotradeinsurance.com/quote
    Ansell gloves i wear czcams.com/users/redirect?even...
    Use code BUNDY25 at unilite.co.uk/product-categor... for 25% off
    Use code BUNDY10 at www.expertelectrical.co.uk for 10% discount
    Join this channel to get access to perks:
    / @nbundyelectrical
    This video is for entertainment purposes only and is in no way intended as a guide or 'how to'.
  • Zábava

Komentáře • 196

  • @amenaspecialist
    @amenaspecialist Před 4 dny +25

    Me and my dad put cat5e though our house back in the 2000’s
    At the time my mum was like, why the hell do we need 8 ports per room 🤷‍♂️
    Fast forward 20 years and there still in use today, and their a godsend!
    Put what you can in while the floors are up!

    • @UhOhUmm
      @UhOhUmm Před 3 dny

      Switches are so cheap, why do you need 8 ports per room?

    • @edknight1982
      @edknight1982 Před 2 dny +1

      Can be cheaper to have just one switch and easier to manage. ​@UhOhUmm

    • @kaasmeester5903
      @kaasmeester5903 Před dnem +3

      @@ortivox That, and it can be used for different purposes if you patch rather than switch. Can run a land line (ha ha), HDMI-over-Ethernet, PoE devices, even non-Ethernet stuff like temperature sensors or thermostats, anything that tolerates a long twisted pair can be ran over Ethernet... as long as it can be connected to something appropriate at the patch panel.

  • @benbarnett1571
    @benbarnett1571 Před 3 dny +39

    Nick try to avoid using CCA cable for Networking, it's not suitable for PoE applications like security cameras and wireless access points. Stick with solid copper cables, they're about 50% more expensive on a box than CCA but it could save you a headache in the future!

    • @calebbrookes7896
      @calebbrookes7896 Před 2 dny

      What type of solid copper cables do you mean?

    • @benbarnett1571
      @benbarnett1571 Před 2 dny +4

      @@calebbrookes7896 Network cables like Cat5e and Cat6 / 6A are either sold as CCA or copper. Solid copper are the better option for infrastructure, terminate at a face plate and then use a patch cable to connect.

    • @MathewSpearey
      @MathewSpearey Před 2 dny +1

      I don't think Nick is using CCA here, as far as I know CCS doesn't supply CCA cable. Still a valid point, to avoid CCA cable though.

    • @simonjz05
      @simonjz05 Před dnem +1

      Can't agree more. CCA has a higher attenuation and also will break easier if bent. This is from experience in my own house.

    • @benbarnett1571
      @benbarnett1571 Před dnem +2

      @@MathewSpearey 11:43 there's a box of CCA on the floor - czcams.com/video/wDTDv7Wbt3Y/video.html

  • @philcoe1857
    @philcoe1857 Před 4 dny +41

    When we had an extension we had a complete re-wire. Got the electrician to run 2 cat 6 points to every corner of every room, 20+ to the office, 20+ to my garages/ workshops and a fibre run to every room, a wired access point in each room/outbuilding, cctv and 4 behind each tv, even a couple of waterproof ones on the deck. Over the top, yes but have come in handy. Biggest regret was agreeing that the spark ran all the cables and I would terminate them. Ended up being over 200 runs and it was mind numbing however all being terminated to a central location means I can run anything to anywhere I.e. HD base T and all my equipment is on one place.

    • @veri8tor
      @veri8tor Před 4 dny +2

      Bet your fingers were sore after all those data terminations 😅

    • @timballam3675
      @timballam3675 Před 4 dny

      Fibre to rooms is a bit over the top but the rest is spot on, I have a 4 core armoured OM3 link from my garden office to house. Nice 20Gbs link at the moment but have some 50Gbs fibre transceivers on the shelf for after the sommer holidays....

    • @davidreason8334
      @davidreason8334 Před 4 dny +7

      Nick, if doing that many network cables and also chasing it, be better they all go to a central location and into a patch panel and to face plates rather than RJ45 ends this would prevent that main cable getting damaged from use

    • @marria01
      @marria01 Před 4 dny +3

      @@timballam3675is that 20Gbps on a single lambda? Or multiple 10Gb links? I've not seen an IEEE ratified standard for 20Gbs interfaces on fiber, I thought it was 25? That said, I'm not sure I've seen any single lane 50 either. We tend to use multiples of 10, 25, 40 and 100 on MTP/MTO.

    • @neilcowen2831
      @neilcowen2831 Před 3 dny

      Bore off bellend

  • @mastweiler22
    @mastweiler22 Před 4 dny +10

    When I see people asking about data cabling for new builds or rewires, I always say put twice as much in as you think you'll need then add a few more. Damn sight easier then than later!

    • @firsteerr
      @firsteerr Před 4 dny +2

      @@mastweiler22 the Brunel method

  • @zombiefeelpain
    @zombiefeelpain Před 4 dny +19

    I ran 24 runs of Cat6a when we stripped our house last year, all ready for data and POE needs running on Ubiquiti gear, great feeling knowing I can get same wifi speeds from the front of the drive to the end of the back garden. 🤣

  • @stevecraft00
    @stevecraft00 Před 3 dny +2

    Probably a bit harder with 25mm but a handy trick with 20mm oval is to squish the end a few mm into the back box. Two benefits. Don't need grommets, and easier to rewire in future.

    • @NBundyElectrical
      @NBundyElectrical  Před 3 dny +1

      Have used this technique in the next video on the rewire mate, I wish everyone did this 30 years ago, to make our lives easier on rewires

  • @richrowley8355
    @richrowley8355 Před 4 dny

    As always, the nod to going the extra mile to do the best job. awesome work ethic mate. Loved the video

  • @eliotmansfield
    @eliotmansfield Před dnem

    I’ve got 62 cat6 data ports in my house. Don’t forget to run cat6 to ceilings for poe access points.
    I have 50mm ducting to all the major parts of the house and outbuildings too - 10 years from the install and I can still add more things in

  • @lordgeeker1138
    @lordgeeker1138 Před 4 dny

    Great video Nick - love learning some of the little tricks you have to make life easier. While I'm not in the trade, I've learnt enough to talk about what I want with my sparky and understand the convo. And wire in some Shelly Pro relays

  •  Před 3 dny

    Thank you man. This is a great video.

  • @tuboid001
    @tuboid001 Před dnem

    Nice leaflet placement on the windowsill! 😉😂

  • @ForTheBirbs
    @ForTheBirbs Před 9 dny +1

    Nice work Nick!

  • @apmullen
    @apmullen Před 4 dny

    Great video Nick very tidy conduit work and I'll use that one some day. Cheers

  • @alhughes9698
    @alhughes9698 Před 4 dny +2

    Good Work Nick.

  • @philphil3707
    @philphil3707 Před 4 dny +8

    Ignore the haters, Nick. I love all your content, and I think you do a great job. It's why I recommend you to my friend, in Warwick, to do his rewire. You did it a few months ago. (Chris Wright). Keep up the good work 👍

  • @seanbranagh
    @seanbranagh Před 3 dny

    When we bought our house back in 2018 I tore the house apart and install Cat 6 absolutely everywhere. 30 cables in total back to patch panels in the garage.
    The materials were not that expensive and I done the work myself. Best thing I ever done. WIfi is no substitute and data cables can be used for other things also. I use one for extending HDMI.

  • @veri8tor
    @veri8tor Před 4 dny +8

    lol every time a sparky runs more than 4 CAT6 they think it’s mental 😂 Welcome to the world of home automation Nick! Wait until you start pulling in 100-200 for the bigger houses 👍🏼
    Top job on the labelling wish all the electricians I worked with did as nicer job as that!

    • @lordgeeker1138
      @lordgeeker1138 Před 4 dny

      The labelling was *does Nicks beautiful kiss thing*

  • @camperventure388
    @camperventure388 Před 4 dny +1

    Impressive stuff. I remember I got my previous house rewired it was a mess the whole house was like a bomb went off, nothing like what you've done it.

  • @NeonXXP
    @NeonXXP Před 4 dny

    I'm extending my house right now and every room is getting data ports and an exchange to share two physical phone lines and networks :) No more WiFi latency, no more fighting over bandwidth.

  • @peterigrenyi9176
    @peterigrenyi9176 Před 4 dny +4

    I think that jole drilled near that notch for paipe or old cable run is waaay too close.

  • @hamfish225
    @hamfish225 Před dnem +1

    Data cables are a must - WiFi is hot garbage with all the interference. From an ISP support perspective, when customers are having speed issues, the first thing we do is say are you on WiFi? if yes, we say OK now try on a cable? no issue? great use a cable. My suggestion is to only use it for things where you absolutely can't use Ethernet cables. There are just too many factors at play with WiFi that can cause you all manner of issues.

  • @louislunterbusch5571
    @louislunterbusch5571 Před 4 dny +1

    Interesting to see how electrical installations in the uk are made and how different it all is compared how we do it in the Netherlands.

  • @anthonysmiles67
    @anthonysmiles67 Před 4 dny

    Great video as always 👌🏻

  • @johnyoung6479
    @johnyoung6479 Před dnem +1

    very impressed with the installation but confused why you didn't suggest dado trunking in the office.

  • @FrozenThai
    @FrozenThai Před 2 dny

    Interesting, first time I have seen a plastic channel in the wall like that. Probably neat solution for for a wall mounted TV too.
    For comparison, in Norway I would have used pre pulled corrugated plastic conduit and Castor DKS in the walls.

  • @WilliamMulligan
    @WilliamMulligan Před 4 dny

    That was a really neat job.

  • @effervescence5664
    @effervescence5664 Před 4 dny +1

    I do chuckle at VIR stopping in the 1950s and then having 15 years or there about of decent T&E before the horror show that is green goo T&E from 1965-1972.

  • @allahdittababu4802
    @allahdittababu4802 Před 4 dny +1

    Honestly since Adam gone your 💪 are getting bigger ... lol ... good job like all the new kit your using

  • @ukbullylife7968
    @ukbullylife7968 Před 4 dny

    Good work mate 👍🏽

  • @supersparks9466
    @supersparks9466 Před 4 dny +3

    Top job nick, nice to have the time to do it so neatly. I spent 10 years installing data in offices and factory’s , some offices with over 2000 cat 6 points, the terminating at the patch panels were mind numbingly painful to do.

  • @daveash9572
    @daveash9572 Před 4 dny

    When I bought my house, I flooded it with data cabling, totalling 56 points, back to the cabinet, plus six more going to the garage through a 600mm deep trench, all cat 6.
    Guess what? It wasnt enough.
    Ive since had to go back and add more in almost every room, especially the loft and the kitchen.
    Just like sockets, you cant have too many data outlets.

  • @nigelmorse3909
    @nigelmorse3909 Před 3 dny

    Hi I’m a retired electrician. I remember vir cable, interesting that you found some that was still in good condition - the ones I found the rubber had become solid and crumbled to bits if you so much as looked at it

  • @MarcusNailor
    @MarcusNailor Před 4 dny

    Doing a top job! 🙌🙌🙌

  • @lawoila1
    @lawoila1 Před 2 dny

    Finally, someone else who is a member of the church of heatshrink label printing

  • @NorthernMonkeeUK
    @NorthernMonkeeUK Před 2 dny

    I'd say 29 is underkill... When we moved here we ran just shy of 1000m of cat 6a, 63 points termating to a room at the back of the garage. Most of them are in use now.

  • @samphire
    @samphire Před dnem

    Tidy job. If it's a smaller house, these days, I'd run Cat6e to make it future proof at 10Gb. We ran Cat5 when this house was built, every room, every socket, every light switch, I'm slowly swapping it out as needed. I put it in an old newbuild many years ago, the person that bought it off me wanted to cut it out because he wasn't "computer literate", I suggest he just ignored it. The person who bought it off them emailed me out of the blue and thanked me for putting it in which cheered me up. Always put it in if you can.

  • @MrGingerFatCat
    @MrGingerFatCat Před 3 dny

    BEAUTIFUL WORK

  • @simonmaddocks6178
    @simonmaddocks6178 Před 4 dny +1

    Good work be careful with running date side by side to power, you can get signal degradation, look at double shielding as a minimum if parallel and min 100 mm gap!

    • @tcpnetworks
      @tcpnetworks Před 4 dny

      Oah dear... I guess he didn't even thing of that before you commented... Time to read the regs buddy.

    • @lordgeeker1138
      @lordgeeker1138 Před 4 dny

      With Cat6 cable it's much less of an issue. EV Cables even have some Cat5 built in now.

  • @Grow_A_Pair
    @Grow_A_Pair Před dnem

    Did mine in CAT7 (Yup non ratified standard blah blah.) But for £20 for a 1000m drum and 40gb potential on short runs worked out 15 x cheaper than CAT6. it's thicker gauge than CAT6a, rated for in wall, SFTP for extra elelctrical insulation full copper cable and coupled with the right CAT6/7 keystones into a 48 port patch panel you can run the lot fully grounded and benefit from grounded patch cables on both ends. 4-6 ports per room and 8 in the lounge to help with POE sensors and smart devices all terminating to the loft to keep noise down. I still think to this day even with CAT8 available, incredibly expensive and 40gb being overkill for the home... CAT7 is the sweetspot due to so more surplus drums available from companies over speccing and flogging it ;)

  • @paulbrenning7022
    @paulbrenning7022 Před 14 hodinami +1

    That is one small office with too much infrastructure.

  • @Shanky_TH9540
    @Shanky_TH9540 Před 23 hodinami

    I prefer to use 20mm oval and squish the ends slightly, they fit into the metal knock out boxes perfect and dont need a grommet, its a old school way I was taught during training and done it that way ever since for last 20 years

  • @stevenhinchley3588
    @stevenhinchley3588 Před 4 dny

    Did a 6 bed mansion. Ran cat 6nto every tv in the house and a few extra dor some rooms.

  • @likebossgameplay
    @likebossgameplay Před 3 dny

    Have a look at using a media plate for all them data’s and sockets, it’s one plate with 2x double sockets and 8 Euro mods

  • @triplexdread
    @triplexdread Před 4 dny

    First time here kidda, just earned yourself a sub.. ;) Was doing installs for many years. Never seen that stapler thingy. TBH I don't like the idea. Struggle to get ya cables out if anything goes wrong years after install. I do all my networking aswell. Looking forward to see what switches and other gear is installed. Well done..Working on ya own. Quite a big job for ya lonesome that is. I watched a guy a few months ago installing CAT5e on a new install. I critiqued, maybe i shouldn't of but Cat5? I asked why he replied its perfectly fine.........

  • @Bari_Khan_CEng_CMarEng
    @Bari_Khan_CEng_CMarEng Před 4 dny +2

    Nick, thank you so much foe your efforts to tecord and doxument everything, and pass on your experience - it is much appreciated. I am not an electrician by trade but tackling a home data project, and this video was spot on.

  • @user-sk2ms6zn7h
    @user-sk2ms6zn7h Před 4 dny

    Hello Nick please what size chisels did you use so the 25mm trunking could fit in nicely

  • @robertturner2516
    @robertturner2516 Před 4 dny +1

    I like the heat shrink labels. Would it work to label consumer unit tails, earth, neutral and line tails seperate. That could be a game changer on eicr maintenance, as the more times they are delved into the less neat they would get.

  • @dimitar4y
    @dimitar4y Před 4 dny +2

    Make your life easier, instead of worrying about the hole weakening the joists, get one of those reinforcement metals then you can make a big a hole as you want for days.

  • @martinburgess2322
    @martinburgess2322 Před 4 dny

    Apsolute Quality👌⚡👊

  • @carlrobson5745
    @carlrobson5745 Před 9 dny

    That’s a lot of cable 😁

  • @tcpnetworks
    @tcpnetworks Před 4 dny

    Nice work. We can't run into such a shallow box though - there's no room for the mech and cable, whilst maintaining minimum bend radii to the manufacturers minimum. I'd be getting a fail on the compliance checker.
    We don't use cable ties either - velcro is king... That or we are using staples designed for C6. The last two story here in Australia, we installed a meter enclosure outside, with four non-RCD breakers going to subs on each floor, the basement and the shed. Out of there, we had local radials and applicances. 3 Phase subs with everything using AFDDs - mental trying to keep everything correct and in the same switching domain. 30 final sub-circuits and about 60 data outlets in an inner-Melbourne three-story on a 290M2 block. Such a PITA job....

    • @lordgeeker1138
      @lordgeeker1138 Před 4 dny

      Came here to say this - I'd be careful of the metal clips and defo use velcro for Cat6. Also, deeper backboxes (35mm at least) would be better. Terminating with RJ45 and using a 'passthrough' patch panel for home use isn't the end of the world. Personally I'd rather go straight to a patch panel and punch down. Though I have no good stories of sparkies terminating Cat5 / 6 :D

    • @chippy3350
      @chippy3350 Před 3 dny

      Ain’t going to get a failure on short runs may be on say 90 meter runs, usually caused by bad terminations or jacket burn damaging polyethylene coating covering copper core or split pairs…….

  • @sonacphotos
    @sonacphotos Před 3 dny

    For me personally it would be too much. I work in IT so I pull a lot of data cable. For my home I prefer a really fast wifi solution for most devices. I have data POE ran for cameras, doorbell, wifi points and even to my shed so there is wifi and cctv down there. I think I have 13-14 runs. 29 seems excessive but then again given the amount of sockets this customer wants... not surprised.

  • @shawnhayden6674
    @shawnhayden6674 Před 2 dny

    I guess I'm crazy and sticking with 90 plus % wireless everything in residential.

  • @aussiegruber86
    @aussiegruber86 Před 3 dny

    We brought a Milwaukee stapler, but the iron bark hard wood frames in a lot of the older houses makes it useless.

  • @ItsJustPhillip
    @ItsJustPhillip Před 18 hodinami

    What heat gun do you use Nick!? I have a DeWalt but it’s a little overkill and I’m looking to get a smaller one for fitting shrink wrap to cable.

  • @Ste2023
    @Ste2023 Před 4 dny

    Omg love it

  • @familyingram7308
    @familyingram7308 Před 4 dny

    Dear Nick please check CAT 5 and CAT6 standards. Fixed wiring is single core and must terminate on a patch or socket outlet. The IDC connection are not designed for solid and can fail. Patch cable is stranded and matches the IDC. Solid core IDC is a v shape. I learnt the hard way at a large install at the Natural History Museum in London where my install of 100s of connections was rejected by inspection.

    • @jonathanbuzzard1376
      @jonathanbuzzard1376 Před 4 dny

      You can get faceplates and keystone jacks that are compatible with stranded cable. You can also get RJ45 plugs that are compatible with solid core. The reason that solid core is used in the fix bit is *purely* down to cost. It's like electrical wiring you can use stranded to run your ring main but it would be a lot more expensive so nobody does.

    • @JasonEDragon
      @JasonEDragon Před 3 dny

      Having ethernet socket(s) at each destination is a good idea for neatness, but from a practical standpoint, adding a patch panel near where the network switch goes is a bit overkill for residential. That adds cost and complexity, takes up space, and that location is still going to be a rat's nest of cables. Many of the RJ45 connectors I see on Amazon say they are rated for both stranded and solid wire. And for my house I've periodically added new cables and have found it easier to just buy cables with premade ends of the desired length - especially for outdoor POE cameras where a weather rated cable is nice. For POE devices I'd rather have fewer connections.

  • @EdwardBretherton
    @EdwardBretherton Před 4 dny

    nice job but always a but why not just use an adjustable square for the measuring down the joist , better than a stick thing😄

  • @garyeales1116
    @garyeales1116 Před 4 dny

    350mm that’s some thick joists 😂😂

  • @sipols55
    @sipols55 Před 4 dny

    Finally, Nick, some decent content. Something to learn from….

  • @topgazza
    @topgazza Před 3 dny

    Never have enough cat cables. Great video mind you. Very I teresting

  • @sygad1
    @sygad1 Před 4 dny +7

    I installed cat6 to every room, all running back to my office.......ended up ripping it out and replacing with fibre optic to each room with switches in each room, so much easier to manage fibre optic cable than multiple runs of cat6, gives expandability in each room as well

    • @friskyfrogs4747
      @friskyfrogs4747 Před 3 dny +6

      Having to have a specific switch in each room of the home with the relevant SFP connectors, or even fibre convertors is just insanely unimaginable for 99.9% of homeowners. It'd also be probably even less of a number that'll ever even remotely hit the throughput cap on cat6 let alone fibre. God forbit you drilled through one and had to re-run it rather than just rejoining the cable with a connector.

    • @sygad1
      @sygad1 Před 3 dny

      @@friskyfrogs4747 with a use case of 4 runs per room and a capacity of 8, it quickly adds up, I had a 48 port switch in my office nearly max'd out, that was a huge PIA to cable manage. Now I have 8 pairs of fibre optic cables taking up a faction of the space and I have expandability in every room beyond the 8. Appreciate it's not for every home, but home automation and distributed AV soon puts a demand on individual runs going back to a central location.

  • @Eileen-p4v
    @Eileen-p4v Před 4 dny

    Nick. With the pipe work being run over the joists, I've seen metal plates being added to protect against screws, nails. Also those place where cables have been notched in the joists. Would you consider this if not a total rewire?

  • @ConfidentialMeerkat
    @ConfidentialMeerkat Před 4 dny

    Im in the process of dragging my grandparents' 1905 house into the 21st-century and by god is it putting up a fight! as the walls have what appears to be flint in them making it difficult to drill or chase cables in Im now having to use conduit to put runs into the few rooms that need it as the walls are so thick wifi does not get to where its needed! Really the place needs to be stripped right back to brick and start from fresh but they are too old at this point for such upheaval, thats the next owners problem!

  • @darrencoyle3290
    @darrencoyle3290 Před 3 dny

    Excellent quality of work Nick ..I am looking to run a Cat 6 cable externally on an outside wall of my house, is there any type of small oval capping that you know off.

  • @stevenhinchley3588
    @stevenhinchley3588 Před 4 dny

    Like it mate

  • @streaky81
    @streaky81 Před 4 dny +2

    Over the top? Naw, I installed a backbone of OM4 in my house that runs up through three stories that will do me for 100gbit with current tech with a change of optics and probably more in future (though I'm using it to connect three switches at 10gbit). That's probably over the top - but I know I won't need to touch it for 20 years so swings and roundabouts. People who rely on wifi are mad as a bag of cats, particularly if they consume media or WFH.

    • @tcpnetworks
      @tcpnetworks Před 4 dny

      Hey - that's the way to do it. I have OS2 to the shed, 400M away, installed 19 years ago. I've got fibre right around the property now... Simpler to use.

    • @lordgeeker1138
      @lordgeeker1138 Před 4 dny

      @@tcpnetworks Ha, I considered fibre to a new garage connection. And between floors. Ultimately I decided a short 10gb run on the Cat6 will do me. (replaced the rubbish Cat5 the sparky ran to the garage though!). Please tell me you have a media server and aren't just browsing the web :D

  • @SixStringNoiseBox-vv7lu

    350mm thick joists? Are you sure?😁Also, that's a lot of data. Good job man. Noice

  • @chandreshvarsani2190
    @chandreshvarsani2190 Před 4 dny +3

    Really need to use a dedicated space out of sight for Data and CCTV cabling such as the loft. if that office ever needs to have a change of purpose then it will look awful with cat 6 out of the wall and way too many power sockets, I would usually advise clients to purchase a Power Distribution Bar (PDU) which can give up 8+ sockets and be mounted on wall of fixed underneath desk

    • @chandreshvarsani2190
      @chandreshvarsani2190 Před 4 dny +1

      Ceiling mounted Unfi AP Pro in every floor would be very reliable also and may need more than one on ground floor for garden wifi also

    • @lordgeeker1138
      @lordgeeker1138 Před 4 dny

      @@chandreshvarsani2190 Yep, I got a single U6 mounted top of the stairs which is pretty central. Just added one into the garage as drive way / garden was low signal. But please, feed the cable through the celing, not putting a network plate ON the ceiling! Putting a cab in the loft is preferable, unless you have a central cupboard - just watch for heat it if it gets hot in summer. Mine has been okay, even during the 40 degree summer. Just.

  • @firsteerr
    @firsteerr Před 4 dny +1

    set up your square save time when repeat measuring

    • @NBundyElectrical
      @NBundyElectrical  Před 4 dny +1

      good shout

    • @firsteerr
      @firsteerr Před 4 dny +2

      @@NBundyElectrical of course there is a 99% chance that once you have finished put the boards back andcthey carpet is down you will realise you left it in the void

    • @NBundyElectrical
      @NBundyElectrical  Před 4 dny +1

      @@firsteerr that is a very high possibility, mate. I wouldn’t be the first time.

    • @firsteerr
      @firsteerr Před 4 dny

      @@NBundyElectrical I have left the minimum for five complete fans tool kits under floors in ceiling voids over the years at least

  • @HussainAhmed-ku4kn
    @HussainAhmed-ku4kn Před 4 dny

    Could you do a video what keep on your person, like what you keep in your pockets at all time?

  • @TornTech1
    @TornTech1 Před 2 dny

    My biggest Pet hate; Sparkies running data cables 😏

    • @NBundyElectrical
      @NBundyElectrical  Před 2 dny +1

      @@TornTech1 my biggest pet hate is that last bit of wee that dribbles out after your finished 😬

    • @TornTech1
      @TornTech1 Před 2 dny

      Oh yeah! That’s horrendous! Can’t shake it off either right… otherwise it goes over the front of your shorts/jeans and is super obvious!

  • @paulblundell8033
    @paulblundell8033 Před 3 dny

    Had so many issues with 3rd party heat shrink labels. Brother do seem to make it hard to use them. I can get them to print but get the same warning message.
    The Brother original are so expensive and only having 1.5m with the waste a Brother printer can have whilst printing can rack up the cost.

  • @leescott5326
    @leescott5326 Před 3 dny

    over the top? I've got 28 in my gaff and i thought i was quite conservative!
    all new build houses should come with data cabling to every room

  • @GrahamWoodward-ww1zf
    @GrahamWoodward-ww1zf Před 23 hodinami

    Would the office possibly have been better off in 100x50 compartment trunking, quicker, cheaper, flexibility for future movements and able to be removed if converted back to a bedroom.

  • @UKsystems
    @UKsystems Před 4 dny +1

    This is the bare minimum of data runs if you’re going to bother to install networking

  • @voltare2amstereo
    @voltare2amstereo Před 4 dny

    11:53 Adams mum know the feeling

  • @thesavo
    @thesavo Před dnem

    So. UK electricians just DADO a slot in the wall for the electrical wires? What is the protection for that?

  • @se9225
    @se9225 Před 19 hodinami

    I'm going to be running fibre cables alongside CAT 7 on my refurb.. then I'll know I'm 100% future proof but I'll be running inset conduit should I need to change cables should the intranet develop any issues.

  • @Andrew-su3wt
    @Andrew-su3wt Před 4 dny

    If the new holes you drilled were between 0.25 and 0.40 of the span from the support around min 9 it must be a very small room ?

  • @ghosttownlives
    @ghosttownlives Před 4 dny +1

    i have 25 devices scattered over 3 floors/2200sqft + outbuilding at the bottom of the garden, all served over wifi-6 by a single ax1100.
    *no data cables needed🔌*
    the router happily pumps out full bandwith across the house.
    mind boggling that people are still dropping cables in 2024😆

    • @Monkeh616
      @Monkeh616 Před 4 dny +2

      20 years of experience of wifi equipment in the real world is plenty enough reason not to rely on it. Of course, we have wildly differing definitions of 'full bandwidth'..

    • @tcpnetworks
      @tcpnetworks Před 4 dny +1

      Good for you. Performance must be only barely adequate. Those calculations don't work for performance, reliability. End devices connecting at AX wouldn't be very happy on the fringes.

    • @lordgeeker1138
      @lordgeeker1138 Před 4 dny +1

      How does the Power over ethernet for things like phones (as we move to VOIP), cameras etc work? Backbone of cable, suppliment with Wi-Fi

    • @ghosttownlives
      @ghosttownlives Před 3 dny

      @@Monkeh616​​⁠
      full bandwith:
      400mb at the hub
      400mb at the bottom of the garden.
      in the real world even McDonalds or the local village library can happily serve 100 users with free wifi simoutaneously.

    • @ghosttownlives
      @ghosttownlives Před 3 dny

      @@tcpnetworks​​⁠​⁠
      pretending something doesnt exist, doesnt stop it from existing.
      as a progressive, i will try something (in real life) instead of making up a false narriative.
      if i know for sure i have tested a solution then i can present my findings with confidence and ensure i am not spreading mis-truths.
      no one is going to stop you spending thousands on obselete data cable, i will stick with routers which will only get faster with the passage of time.
      your cable once installed, you are stuck with it till you rip it all out again.
      this comment will age well⏰⏳🕰️

  • @dimitar4y
    @dimitar4y Před 4 dny +1

    12:44 And add "Brother" to the blacklist right next to HP with their "genuine cartridge" tyranny.

    • @sciroccomods
      @sciroccomods Před 4 dny +1

      I use non genuine cartrages in my brother heatshrink/label machine, and the postage label machine. Just wish i could work out how to stop the wasteage on the heatshrink. Do i really need a huge off cut piece, what a waste.

  • @firsteerr
    @firsteerr Před 4 dny +1

    like garlic bread , its the future i have two in each room ready for all sorts hard wired is better then why fy

  • @AddieDirectsTV
    @AddieDirectsTV Před 4 dny

    Why does the VIR cable look like the Romex cable we have over here?!

  • @Richardincancale
    @Richardincancale Před 4 dny

    I was so happy this week to have a spare data outlet in the living room. Wanted to install a remote digital temperature sensor and was not looking forward to drilling a hole in the concrete floor. Chopped a patch cable in two and soldered one end to the sensor and the other end to the special plug on the monitor - much simpler!

  • @JohnJKelly-of4dc
    @JohnJKelly-of4dc Před 4 dny

    Iv came across cable with a fabric covering as well as rubber...very odd, I'm guessing

  • @tonywatson1412
    @tonywatson1412 Před 4 dny

    Think the earth might have been tinned copper... not sure did,nt seem to tarnish ...even very old terminations were ok. when unscrewed....

  • @Beaglepup70
    @Beaglepup70 Před 4 dny

    I remember the smell just looking at VIR….

  • @johndoe2769
    @johndoe2769 Před 4 dny +1

    Cant believe you didnt print out "Adams mum" for the camera 😂. Missed a trick there

    • @NBundyElectrical
      @NBundyElectrical  Před 4 dny

      next time I promise

    • @johndoe2769
      @johndoe2769 Před 4 dny

      @@NBundyElectrical I was sure it was coming too. Waiting for the camera lens to focus 😂. Lol

  • @TheShinnion
    @TheShinnion Před 4 dny

    Nick your a humdinger 👍

  • @VsUK
    @VsUK Před 13 hodinami

    Your label printer, do you update its software btw? Because unless there's a software problem or a general issue running the printer, you should never update the firmware because what this does is update the software that recognises after market cartages or universal ones to refuse to work with them not because of hardware, but intentional software blocks. And when they release a new update, it's due to new cartages having it's chip software updated to bypass the manufacturers software blocks.
    Just like with inkjet printers, unless there's a problem, never update the firmware or you'll find it no longer works with any of your cartages.

  • @erolozkan2168
    @erolozkan2168 Před 3 dny

    U’ilise or utilise? The only thing you continue to say that gets on my nerves! 🤣
    Love the vids nick!

  • @jonathanchappell9596
    @jonathanchappell9596 Před 4 dny

    Nick, the capping with the all round band is a game changer. I have to confess I got this idea of you a while back and it’s helped me out so much so thank you 🙏🏻 👊🏻👏🏻. Great work and attention to detail as always.

  • @lesmoor001
    @lesmoor001 Před 4 dny

    a lot of work for one guy

  • @kyester123
    @kyester123 Před 4 dny

    Nick Bundle

  • @user-jj6di9sv8h
    @user-jj6di9sv8h Před 4 dny

    👍👍

  • @nickharvey5149
    @nickharvey5149 Před 3 hodinami

    Please dont terminate the CAT6 to RJ45's. They should go to modules.

  • @ShreeBalajiElectricaljhabua

    I am Indiam Electrician ❤

  • @GregNow
    @GregNow Před 2 dny

    0:50 😂😂😂😂😂

  • @voltare2amstereo
    @voltare2amstereo Před 4 dny

    I despise terminating cat cable, but know how, it's been handy many times.
    Gw-G Ow-B Bw-O Brw-Br