Perfect earthing for 🏠 Home | Full process to making of plate earthing with PVC pipe
Vložit
- čas přidán 30. 06. 2021
- #BEEEWorks #Earthing #electricals
Hello Friends ! Welcome back to our channel. I hope this video may helps you 😊
🔴 Red wire = Phase
⚫ Black wire = Neutral
🟢 Green wire = Earthing
🔷Like 🔷Share 🔷Comment 🔷Subscribe
___________________________________________________
⚫ Follow us🔻
🔶 CZcams -1
/ @megaelectricals
🔶 CZcams -2
/ beeeworks
🔶 Instagram
/ beee.works
___________________________________________________
⚠️ WARNING...❗
This video is only for educational purpose. High voltage can damage your life. Some works can be Dangerous. And for that, you dont risk and damage your self. Iam a professional in my work. You should take care or precautions before attempting the experiment or work.
___________________________________________________
🔷 For Business Quarys🔻
💌 beeeworks.official@gmail.com 😊
___________________________________________________ - Věda a technologie
Beautiful very good sir. God bless your family.
Very nice to see this particular interest and informative earting demo.. I like and to see more
Simple and best video sir
Full detel and easily install
thanks sir
Thankyou thankyou thankyou.. Very very important procedure.. It is very useful for Electrical. For wiring new structures..
......
Kafi knowledge full video bhai
Excellent
Nice working 👍
Good proces.. Helps a lot for domestic power consumer s who do not have any knowledge about earthing /Grounding procedure.
This video is very useful to me.
Thinks gee.
Very nice explanation
Vrey very nice video hai
Nice presentatin ..superb
Good information bro thankyou.
Super ❤️🙏 THANQ VERY MUCH FOR YOUR BEST PRESENTATION SIR 👌🙏
افهم اشي كيف إنتاج الكهرباء
@@saadhegmssaadhe7661 ý
Good work thanks bro
Super Anna well done bro
Nice work ze
Thanks a lot for good video ,sir
Good work 👍👍👍👍
Wonderful
Very nice sir.
Good job. Suggesting to speak on each step. Use yellow/Green cable for Earthing. Also use terminal clip/lugs for termination
W s r s t up in
O
Excellent Work
Nice. kindly do more videos with explanation.thank u
Sure
Good idea
Good video sir
Super👍
Very nice sir
Very good 👍
Very fine information. Thank you
Hi sir send Ur contact number
Contact in Instagram
Great 👍 job, but you didn't run an earth resistance test to know the actual earth resistance value..
Earth resistance must be zero thats why bulb glown...
@@ashwinsawant6466 resistance ager zero hoga to current kaise zammen me jayega. Suppose V=230v and resistance=0 then I=V÷R,230/0=infinity isiliye earth resistance 1 ohm hona chahiye
Great
Good very good
Super thank you
Super brother
THANKS YOU SIR
Good job
Nice sir
One nambar
Amazing
Very nice
సూపర్ అన్న
Super anna
Very good information. You could have used screwdriver for tightening instead of tester. Thank you. Vaazhga Valamudan
Very nice boss
good video
Supar 😊😊😊
Good work. The GI Earthing plate witj Pipe may be made at least 10 Ft long for lower Earth Resistance.
Nice
Super bro vera level handsome 🙂🙂🙂🙂
Super
Keep it up guys 😁
good da boiiii
good but had it been more effective if wire would have been bolted directly with the copper strip rather than with the aluminium strip.
Good information
In this case which rule is applied I don't know, but I am sure it is not at per IE rules.
Copper & G.I both are different metal but making joint each other, what will be the reaction that was not described. Also the value of earth resistance was not mentioned. Only shows the glowing lamp, how the values of earth resistance measures, by which instruments not mentioned, value of earth resistance is important factor.
Thanks for your hard work & sincere presentation please.
Exactly.
Never coupled two different metal this create galvanic couple and favorite metal corrosion (add salt improve this ionic exchange and quick the corrosion of metal..
Copper need screws and copper joint.
👌👍😎
Good job
But please increase the conductor size to atleast 16mm for it to carry the fault curren
Current
No need to add 16mm wire. Leakage current is rarely passing into ground. Hence we just need 1 to 2mm wire.
நன்றி நண்பா
25 years ago I used this type of earthing, single pase wire connected about 1 km distance from home electric supplied about 8 hr in a day, past remembrance fresh again. Thanks lot,
Electricity chori??
You hav been stolen electricity 😜
@@aqualivesashtamudi3076 that time 4/5 hrs electricity got in whole day, one transform was enough, now every house have connection and 20/22 hrs electric supply,
@@Devkayasa ok I understood
Bill bhi aata hai kya ??? Digital meter m ..
Good.
Thank you sir
MY UNDERSTANDING IS THAT THE GROUNDING ROD SHOULD BE AT LEAST 2 METERS LONG FOR GOOD EARTHING, & 1 FEET EACH OF ALTERNATE LAYERS OF SAND, COAL & SALT TO THE TOP & PROPERLY SANDED ON TOP. THE PIT SHOULD BE DUG AT LEAST A METER FRONT THE HOUSE.
Like g 🔥🔥🔥🔥🔥🔥🔥👍🎈
Perfect earthing
Dear sir do not put salt in the pit. The copper plate will corrode.you can expect nothing in the pit after a few months.not only the copper plate but also the GI pipe.
It's true..
how about the copper pipe?it can also affected by salt?
Very very vital vedio .
👌👌👌👌👌👌👌👌👌👌👌👌
nice process at last the bulb how glown
If Earthing is perfect then glow, Earthing act as Nuetral
Good
use nut bolt with washers for better contact instead of screw nut.
Good Work
Good effort but is it as per Is: 3043. It would have been better to explain the dimensions of excavated pit, size of pipes, thier grade, qty of salt, charcoal, What is earth resistance, what device used to measure it ? Kindly clarify , thanks. Regards. Jai Hind
If the 100watts Bulb is glow, the value of Earth resistance is too near the required resistance of Earth. To improve ur earthing resistance maintain the earthing as a wet.
Dear Sir, namaskar, your reply is not satisfactory and as per line of requirement. Merely glowing 190 watt lamp is not the solution. Your arrangement is approved by CPWD or PWD? Regards.Jai Hind
You seem to be blindly following some practice
Please provide Testing methods for proper earthing.
किन एस्तो झन्झट गरि बस्नु , बरु सिदै तामाको रड पाउछ बजारमा तेइ हाल्दिने नि । काम तमाम 👍️
Nice information
Yes, indeed 😎
Earthing ఇది proper గా లేదు.
1.earthing కు pit (గుంత) వెడల్పు కనీసం 0.500 మీటర్స్ ఉండాలి.
2. ఎర్త్ పైప్ appr.4 నుండి 6 ఫీట్స్ ఉండాలి.
3. ఎర్త్ ప్లెట్ తో పాటు కొంచెం కాపర్ వైర్ ఎర్త్ ప్లేట్ కు చుట్టి భూమిలో కి పాతలి. ఎందుకంటే GI పైపు కొన్ని రోజులకు rust పత్తి దానికి ఉన్న copper ప్లేట్ ఉడిపోతుంది.
కావున పైప్ కు చుడుతూ భూమిలో కి వెళ్ళేవిదంగా చుట్టాలి.
4. భూమి లోపలి నుండి వచ్చే కాపర్ వైర్ మరియు ఇంట్లోకి కి వెళ్లు ఎర్త్ వైర్ ని ప్రాపర్ గా జాయింట్ చేయటానికి GI పైపు పైన nut బోల్ట్ use చేయాలి.కానీ ఇక్కడ స్క్రూ తో పిట్ చేశారు.
5. Use చేయాల్సినవి.
..... salt (దొడ్డు ఉప్పు 25kg
........బొగ్గు 25 kg
ఎంత ఎక్కువ గా సాల్ట్,బొగ్గు వేస్తామో అంత ఎక్కువ గా ఎర్త్ లైఫ్ ఉంటుంది. వాటర్ పోయాటానికి ఈ విదంగా పైప్ use చేయొచ్చు.
Do you have a video demonstration also?
👍👍👍🙋
Sir meru volteg check cheyandi
Sir, are you get the proper earth value or need to use copper legs and nut boalt with washers, good effort
Ha ! find mistakes. First u form proper sentence. Ur English is poor.
CAN WE USE STEEL PIPE INSTEAD OF GI ??
@Phase and Neutral thank u
Lug vestey enka baga untadi
Earthing ఇది proper గా లేదు.
1.earthing కు pit (గుంత) వెడల్పు కనీసం 0.500 మీటర్స్ ఉండాలి.
2. ఎర్త్ పైప్ appr.4 నుండి 6 ఫీట్స్ ఉండాలి.
3. ఎర్త్ ప్లెట్ తో పాటు కొంచెం కాపర్ వైర్ ఎర్త్ ప్లేట్ కు చుట్టి భూమిలో కి పాతలి. ఎందుకంటే GI పైపు కొన్ని రోజులకు rust పత్తి దానికి ఉన్న copper ప్లేట్ ఉడిపోతుంది.
కావున పైప్ కు చుడుతూ భూమిలో కి వెళ్ళేవిదంగా చుట్టాలి.
4. భూమి లోపలి నుండి వచ్చే కాపర్ వైర్ మరియు ఇంట్లోకి కి వెళ్లు ఎర్త్ వైర్ ని ప్రాపర్ గా జాయింట్ చేయటానికి GI పైపు పైన nut బోల్ట్ use చేయాలి.కానీ ఇక్కడ స్క్రూ తో పిట్ చేశారు.
5. Use చేయాల్సినవి.
..... salt (దొడ్డు ఉప్పు 25kg
........బొగ్గు 25 kg
ఎంత ఎక్కువ గా సాల్ట్,బొగ్గు వేస్తామో అంత ఎక్కువ గా ఎర్త్ లైఫ్ ఉంటుంది. వాటర్ పోయాటానికి ఈ విదంగా పైప్ use చేయొచ్చు.
Nice job
How many centimeters have the hole ? Wich materiels you used to do the pick of ground?
Sand use it is roung prossess pit depth not sufficient
ये आर्थिंग पे सिंगल फेज मोटार चल सकती है क्या . सर नमस्ते आपने व्हिडिओ काफी अच्छा बनाया.धन्यवाद सर .
ഇത് നമ്മുടെ നാട്ടിൽ പറ്റുമായിരിക്കും, ഹൗസ് വയറിങ്ങിൽ, ഇൻഡിസ്ട്രി വയറിങ്ങിലും ഗൾഫ് കൺട്രി വയറിങ്ങിലും നടക്കില്ല, മെഖർ ടെസ്റ്റ് നിർബന്ധം.
Process correct,but length at least 4 feet
Nice sirg. Is this permanent solution of earthing?
Yes
If MCB is not going to cut off means earthing is not proper in short circuit condition.
in TT scheme, an MCB won't trip, you need a RCD
Insted of back ground music, better to give cometry to understand the correct processary
Your using three type of materials
1Coal
2Salt
3?????
Sand
@@BEEEWorks
It is rever sand or normal sand?
लंबे समय तक काम नहीं करेगा लेकिन अगर कोई ऐसा करेगा तो उस का काम जरूर हो जाएगा।
For earthing Copper plate is required
That's called plate Earthing
सामान्य घर के लिए केवल अर्थिंग उद्देश्य से ठीक है लेकिन इससे न्यूट्रल कनेक्शन का काम सही नहीं रहेगा ।
How did you do it to make the bulb light
Thanks
I would like to know why do these things had used in this process ?
Will you please do this job of earthing pit in our Apartment?
Not possible
1 kw Heating rod laga ke tuch kar phare pata lage ga earthing proper hai
Bahut sunder. Lekin mera ek saval hai. Agar jamin patharili ho to aisi surat men jo gaddha hai uski gaharai jyada nahi ho paati aisi stithi men kya kiya jaye? Please answer me.
100 % it will be fail,, by using wire
Instead of using wire, use GA copper 10 Gage wire
We just need 1mm wire for Earthing bro.
10mm wire for earth bro
Hope you don't mind
You are right
@@BEEEWorks 0.5mm will do
Test grounding resistance
Go to meger test test lamp not good
It is not cleared that the need of PVC conduit digging in the soil & measuring method of Earth Resistance , thanks.