SINAMICS G120C DRIVE COMMUNICATION WITH SIEMENS S7-1200 CPU

Sdílet
Vložit
  • čas přidán 29. 07. 2023
  • HOW TO COMMUNICATE SINAMICS G120C WITH SIEMENS CPU S7-1200 OVER PROFINET?
  • Věda a technologie

Komentáře • 17

  • @zackk_54544
    @zackk_54544  Před rokem

    Kindly share your feedbacks and suggestions

  • @skysrivat
    @skysrivat Před 3 měsíci +1

    I have 1 query here. Why are we creating UDT with 8-15 bits of Cw first then with 0-7 bits of Cw? Is there any reason for it ? I feel some data gets transferred in byte format ?

    • @zackk_54544
      @zackk_54544  Před 3 měsíci +1

      Siemens blocks has predefined bit structure for control/ status words. We have to follow stuructre to read /write the data if we using those blocks.
      For more queries connect on Instagram.

    • @skysrivat
      @skysrivat Před 2 měsíci +1

      @@zackk_54544 :I went through the manual and found that the format is as mentioned by you 🙂 Thank you.

  • @amazighman9935
    @amazighman9935 Před 2 měsíci +1

    Hi, I think that the DPRD and DPWR are only to be used in a PROFIBUS communication right ??

    • @zackk_54544
      @zackk_54544  Před 2 měsíci +1

      Hello, these blocks are to be used for both profibus / profinet communication.

    • @amazighman9935
      @amazighman9935 Před 2 měsíci

      @@zackk_54544 okay, thanks

    • @zackk_54544
      @zackk_54544  Před 2 měsíci

      For more queries connect on Instagram
      All the best

  • @fazimalik5214
    @fazimalik5214 Před 4 měsíci +1

    Quite informative video

    • @zackk_54544
      @zackk_54544  Před 4 měsíci +1

      Thank you for sharing feedback Mr. Malik. Do share your ideas as well, on which you want informative videos.

    • @fazimalik5214
      @fazimalik5214 Před 4 měsíci +1

      @@zackk_54544 well i would like to request you to make a video on a motion control as well.

    • @zackk_54544
      @zackk_54544  Před 4 měsíci

      @@fazimalik5214 Noted, will share the video on topic soon for sure.

    • @zackk_54544
      @zackk_54544  Před 4 měsíci

      @@fazimalik5214 You can also share more specific details regarding your application if you want. Also join the instagram handle as well.

  • @zackk_54544
    @zackk_54544  Před 10 měsíci

    Is your mind running like a Horse? Don't worry
    Read the Chapter-23
    Master your Emotions.
    amzn.to/48JRn4m

  • @lafatraandrianina1849
    @lafatraandrianina1849 Před 4 měsíci +1

    I'm new to the world of plc and I have a few questions in reference to the video which by the way is very good. why do we use the DPRD_DAT and DPWD_DAT blocks instead of the SINASPEED block, what is the difference? and are all these variables in the plc data types all really necessary to put? THANK YOUU🤍

    • @zackk_54544
      @zackk_54544  Před 4 měsíci +1

      Hello Friend, I have not used that SINASPEED block, but as per the block description mentioned in help section I guess we can use it instead of using DPRD_DAT & DPWR_DAT blocks. Main difference is only standard Telegram 1 can be used with SINASPEED. Also, No need to mention all variables in data types but make sure you use the right bit to turn on as per the bit addresses. You can check the help section of the SINASPEED block. Variables are necessary to be defined in the data types If you use DPRD_DAT, DPWRDAT.

    • @zackk_54544
      @zackk_54544  Před 4 měsíci +1

      If your application does not required much functions go for the SINASPEED and share your feedback.
      For more queries you can join the Instagram handle.
      Thank you