  • In this video I am going to demonstrate the change in speed of induction motor using VFD drive which is being controlled by PLC via telegram structure.
    Sinamics G120C Drive or simply VFD (Variable Frequency Drive)
    A Variable Frequency Drive (VFD) is a type of motor controller that drives an electric motor by varying the frequency and voltage supplied to the electric motor. Frequency (or hertz) is directly related to the motor’s speed (RPMs). In other words, the faster the frequency, the faster the RPMs go.
    The benefits of Variable Frequency Drives. VFDs allow you to match the speed of the motor-driven equipment to the load requirement. There is no other method of AC electric motor control that allows you to accomplish this.
    VFDs can reduce energy consumption in your facility by as much as 60%.
    Specifications:
    SINAMICS G120C PN DRIVE with MOTOR
    Drive Specifications : 3-Phase Induction Motor Drive, 0.75KW, 414 Volts.
    Motor Specifications : 3-Phase Motor, 414 Vrms, 1.4Arms, 0.55KW, 0.75 PF, 50 Hz, 1422 RPM, Star Connected.
    Make : Siemens

Komentáře • 12

  • @mohammadomar1558
    @mohammadomar1558 Před rokem +1

    nice & smooth explanation of drive operation through PLC

  • @IK-qu9hw
    @IK-qu9hw Před 4 lety +4

    Excellent video thank so much.

  • @mohammadomar1558
    @mohammadomar1558 Před rokem +1

    searching these type of video many times. at last i got it

  • @amms9016
    @amms9016 Před měsícem

    Sir how to convert RPM to hexadecimal? I try to find online help not found..

  • @chandrasvlogs520
    @chandrasvlogs520 Před 2 lety +1

    Can you plz make a video about how we can configure 10 cpus with one cpu and if I give a command from any one of the cpu that has to be work..

  • @mohammadomar1558
    @mohammadomar1558 Před rokem +1

    big thumbs up

  • @momarmbow8265
    @momarmbow8265 Před 3 lety +3

    How did you get those code for interfacing with g120c ?

    • @nagarjunacharys
      @nagarjunacharys  Před 3 lety +1

      From user manual and also with the help of technician

    • @momarmbow8265
      @momarmbow8265 Před 3 lety

      @@nagarjunacharys please sir can you send me the documentation source and also explain me why did you use the output words Q256 and Q258 . it been two week im trying to understand it . her is my email Mbow374@gmail.com. Thank you again.

    • @momarmbow8265
      @momarmbow8265 Před 3 lety

      @@nagarjunacharys it's ok I found how it work . thanks