- See how to control a Variable Frequency Drive (VFD) from a PLC!
Traditionally you would use the tiny buttons on the drive to commission it or use a separate Drives Commissioning tool.
With Siemens - it’s all integrated into one single package….Drives, PLC, HMI and networking.
No communication protocols to set up, no mapping, no hardwired analog signals…and built in diagnostics is included in simple English text.
The result is that you can set-up and test your project in minutes rather than days.
#VFD #G120 #SINAMICS
________
Helpful Resources:
G120 + Simatic HMI (without PLC), display alarm and error messages via text list:
support.indust...
SINAMICS G Speed Control using “SINA_SPEED” block
support.indust...
Application Examples: support.indust...
______________
Connect with us:
LinkedIn: / eandm
CZcams: / eandmonline
Twitter: / eandmonline
Facebook: / eandmonline
Best Video I seen for Drive Configuration , Thanks
How to download Library
Useful information, Thank you so much.
very informative video but I could not find the drive block which u added.
Excellent presentation Hardik, I appreciate it, thank you to make it so simple.
This is the best tutorial I have seen concerning how to control VFD with TIA Portal. Thank you! Please how do I find where to download the text list for Diagnostics? Thanks again!
Thanks Hardik for uploading this informative video,
please upload more vidoes of PLC communication with 3rd party VFD's via PROFIBUS
Nice job. Thanks Hardik.
hi everyone! i want to control my VFD using simatic manger... may somebody please help me..
Wonderful tutorials
what communication method you are using? and how to set up related parameters in the G120 drive? drive control block is a function block?
Thanks sir .... Please tell me what things in the VFD are must to know as.a fresher automation engineer
please can you share the program inside the FC ?
Hi hardik thanks for sharing such a great video. i have a task for designing a rig crane having the 3 main operating functions i.e. Slew,boom & hoist so can u give me some guidence on that plz.
Please suggest How to Run MM420 and MM440 with siemens S7-315/2 pn/dp on Profibus. .....
Sir .I have problem in my vfd can u help me .Schneider vfd altivar 61
What if I use SINA SPEED ? It do the same thing
Hardik,Where on Siemens support did you find the preconfigured drive block?
Sir i want to know how can i download that library block.
i want to know how Torque should control in Micromaster440 .
where did you get that drive block?
Nice workm please send me the FC block, i cannot find it
I need some help about vfd atv 61???
brother can u provide this drive
Sir please help me sample project source files 🙏for practice
What if there where two drives ?, How is the function block pointing to the particular drive connected ?,
S7 PLC inputs IW256 and IW258 receive 'Status word 1' (ZSW1) and Speed Actual from the first G120 drive and S7 PLC sends 'Control word 1' (STW1) and Speed Reference from QW256 and QW258 to the first G120 respectively.
A second G120 drive on the same PROFINET network would need to use different input addresses (e.g. IW260 and IW262) and output addresses (e.g. QW260 and QW262) of the same S7 PLC.
The PROFINET telegram used in this example only sends and receives 2 words each way.
Hope this helps you 6 months on.
Can you simulate the VFD? I mean without the hardware
I was searching for this for long time did you find any method to simulate with h/w
So i walked through the entire Siemens support site and could not locate this block. Did you make the block yourself from the V13.1 sample program and then save it to your global library? its hard to reproduce this exaxtly with out the block referenced in your video, Would you please include a link in the description to the correct support forum with the FC you used? Thanks
Please send us an email to support@eandm.com and we'll send you the block and library.
@@eandmonline I looked for this block all over Siemens website and couldn't find it too, could you please send me the block to mokrane.ouarezki@gmail.com, thank you very much in advance.
Where on Siemens support did you find the pre-configured drive block? i search on siemens online support but didn't get it. can u please send me link for that
+Sumit Jadhav The blocks are included under Instructions/Technology in TIA portal. See screenshot here: www.eandm.com/media/EandM/images/TIA_Portal.jpg
I am not getting drive section in the add new device section can someone guide me what can i do.
Hello. You need to have STARTDRIVE installed. Do you?
how can I download drive that you've got or somehow if you can help, please gimme the content. thanks very much
+nguyenvan linh We're not quite clear what you're asking. Could you send us more details/particulars for what you need? You could also try sending an email to support@eandm.com.
i am not getting that block for v13?
Hello Dinesh,Please send us an email to support@eandm.com and we'll send you the block and library.Thanks!
Hi, Do You have a similar block for profibus network between PLC and a sinamics G120? I sent you an e-mail for the "drive FC", thanks in advance, nice video.
@@eandmonline HI sir good day, can you send also to my email for educational purposes. Thank you, juantamad17delacruz@gmail.com
How to get free Siemens plc software
were can i download the drive block???????
Hello! Hopefully this will help: The blocks are included under Instructions/Technology in TIA portal. See screenshot here: www.eandm.com/media/EandM/images/TIA_Portal.jpg
please tell me sir how to control vfd with only profibus
Where can i Download the Drive Block?
Hello. You can do so here:
www.automation.siemens.com/mc-app/sinamics-application-examples/Home/Index?language=en
Great explained but I still can´t find the Drive block that You are using... Did You download it from Siemens or did You made it yourself?
Hello Mats-Erik. Did you try this link? www.automation.siemens.com/mc-app/sinamics-application-examples/Home/Index?language=en
Yes, but I´m not sure wich of the applications I should choose...
Watch this video to see how to control a VFD with a PLC via Ethernet in only 5 minutes. czcams.com/video/VcaxeTn4VZU/video.html