Design of footing | Isolated Square Footing | Limit State Method | IS 456-2000 | RCC Footing Design

Sdílet
Vložit
  • čas přidán 9. 11. 2019
  • Complete Design of Isolated Square Footing with uniform thickness is explained in detail. Explained clearly how to fix Size of Footing, how to Calculate Net Upward Pressure, fixing Depth of Footing, how to Perform check for One Way Shear also known as Beam Shear, how to verify Two Way Shear (Punching Shear), determining Area of Reinforcement explained in simple and lucid manner, all stipulations follow Indian Standard Code IS 456-2000, all page numbers used from IS Code has been mentioned while solving problem .
    My Phone : amzn.to/311uFDW
    Amazon Basics 50-Inch Lightweight Tripod with Bag : amzn.to/3ayCdkG
    Laptop : amzn.to/3hi2yGp
    Limit State Design of Reinforced Concrete Design by B.C.Punmia : amzn.to/315UEu2
    Reinforced Concrete Design: IS:456-2000 Principles and Practice : amzn.to/315WLxY
    Illustrated Design of Reinforced Concrete Buildings : amzn.to/349rM62
    Design of Reinforced Concrete Structures : amzn.to/3142DYz
    Any difficulties encountered in this video, you can comment in the comment section and we will try to solve your difficulties within 24 hours.
    #squarefooting #designoffootings #isolatedsquarefooting #gate2023

Komentáře • 417

  • @vasachisenjubean5944
    @vasachisenjubean5944 Před 4 lety +86

    By far the best video regarding footings, on the internet

  • @satya4472
    @satya4472 Před 2 lety +44

    Legends here ,during exams.🙂

  • @ChandanDas-de6cv
    @ChandanDas-de6cv Před rokem +9

    Sir, please set the dog free. He's just crying continuously. 😢

  • @rajacharibr1584
    @rajacharibr1584 Před 2 lety

    Net upward pressure u have done wrong its only column load by area u have taken total load make it correct

  • @constructionvt9955
    @constructionvt9955 Před 3 lety

    Sir ..u don't find the development length and finely u don't show the cross section of footing....

  • @gajendra_kanwar394
    @gajendra_kanwar394 Před 2 lety

    Why column size is .5?

  • @PujaKumari-rj8qv

    Sir size of column is not given in the question then how you have taken b=0.5? I'm totally confused😢

  • @vedantpawar230
    @vedantpawar230 Před rokem

    We are to design the footing for total load that is dead load and superimposed load, then why to design the footing for the 660 KN rather than 1260KN

  • @inyshel7018
    @inyshel7018 Před rokem

    the puppy in the back

  • @HemantKumar-hn7lx
    @HemantKumar-hn7lx Před 2 lety

    Sir,net upward pressure nikalte time w ka value total load lenge ya factored load.please clarify the doubt tomorrow is my semester exam

  • @Dmanish54

    Please tell no of bars in central band

  • @fakrudinahmed5141
    @fakrudinahmed5141 Před 2 lety +3

    Sir u r one of the best lecture i have seen in my life wish I would had youtube during my college days i would have been design engineer at this moment

  • @abhinavmishra1990
    @abhinavmishra1990 Před 2 lety +6

    I wish I could have got this video during my graduation...highly recommended to study/revise structural engineering

  • @harikrishna0204
    @harikrishna0204 Před 3 lety +7

    Exam time Lo ela prepare avalani fear undedi but your explain so good thank you so much

  • @avinashkumar2730
    @avinashkumar2730 Před 3 lety +7

    I think this is the best way to understand the footing problems

  • @parthdhoriyani6982
    @parthdhoriyani6982 Před 3 lety +4

    There is calculation mistake in punching shear step:

  • @marvilnelson8350
    @marvilnelson8350 Před 2 lety +5

    Thanks very much, you are a very good lecturer for better than the ones that I have at my school.

  • @abhisheksing8379
    @abhisheksing8379 Před 3 lety +9

    Wow! All of my doubts were cleared just looking at the diagrams. Great work, sir. Thanks a lot.

  • @denimrajsaikia652
    @denimrajsaikia652 Před 3 lety +5

    The best and simplified explanation on footing

  • @veerendrapal4088
    @veerendrapal4088 Před 4 lety +7

    Thank you so much sir you have cleared all my doubts regarding isolated footing.🙏