Design of Cantilever Beam | How to Design a RCC Cantilever Beam | Cantilever as per IS 456-2000

Sdílet
Vložit
  • čas přidán 8. 09. 2024

Komentáře • 161

  • @dipen_official
    @dipen_official Před 3 lety +10

    Sir we love yr videos a lot, plz be concern on our interest of learning through yr videos
    And teach us continuously

    • @structuralanalysisanddesign
      @structuralanalysisanddesign  Před 3 lety +2

      It gives me immense pleasure to know that you all love my videos, definitely i will try my best to upload videos regularly

    • @rohitshetty8758
      @rohitshetty8758 Před 2 lety

      ​@@structuralanalysisanddesign why you took 1.5

    • @rohitshetty8758
      @rohitshetty8758 Před 2 lety

      ​@@structuralanalysisanddesign sir

    • @mdhasann2640
      @mdhasann2640 Před 2 lety

      @@rohitshetty8758 it's an factor of safety

  • @bigfore7083
    @bigfore7083 Před 3 lety +6

    I wonder, how on earth someone put a dislike to such well polished explanation

    • @structuralanalysisanddesign
      @structuralanalysisanddesign  Před 3 lety +2

      Thanks for appreciating, some people will be there to dislike but it gives us more motivation to do more videos which are helpful to civil engineering community

  • @vikeshtalda1069
    @vikeshtalda1069 Před 3 lety +2

    Thank you sir, your explanation is so simple, we understand like a piece of cake.

    • @structuralanalysisanddesign
      @structuralanalysisanddesign  Před 3 lety

      So nice of you, these kind of words will motivate to come up with more videos, support us by sharing, all the best

  • @ashokkumarar4334
    @ashokkumarar4334 Před 2 lety +2

    I found something wrong i.e., Instead of taking Mu=0.138 fck b d2 for Fe415 you took Mu= 0.133 fck b d2 which is for Fe500.
    I have been seeing all your videos and its very clearly explained.. Keep doing brother..

  • @yuwabharatshakti3603
    @yuwabharatshakti3603 Před 3 lety +4

    First of all gd evening।
    Your videos is very helpful in ssc je mains paper।

  • @saifaly359
    @saifaly359 Před rokem

    A very thank you sir. Because of you I passed this subject

  • @civilexplorer7038
    @civilexplorer7038 Před 3 lety +10

    Sir, In the problem u have taken Fe415 grade but while finding d u took
    Mu= .133fckbd2 which is for Fe500. As well Mulim comes out to be 94.46kNm

  • @slgamerty9076
    @slgamerty9076 Před 6 měsíci

    Ur my god plz continue your vedios 🎉🎉 super explanation sir 😊

  • @fistonndongalo139
    @fistonndongalo139 Před 3 lety +1

    SIMPLY THE BEST , Keep up the great work Sir

  • @MasterCivilEngineering
    @MasterCivilEngineering Před 3 lety +4

    Awesome video Sir

  • @shashankda2002
    @shashankda2002 Před rokem +1

    Thank you so much sir. Please make more videos of different methods. ❤️❤️

  • @abhijeetbhatnagar3562
    @abhijeetbhatnagar3562 Před 3 lety +1

    Thank you sir, very well explained

  • @structural_design8001
    @structural_design8001 Před 3 lety +2

    It is good practice to provide at least 25 % of the Ast (minimum) and subject to two bars (minimum) at compression side also, even if it is not required,

  • @surajthapa1059
    @surajthapa1059 Před 3 lety +1

    thanks sir from nepal

  • @tendayimapawona3237
    @tendayimapawona3237 Před 9 měsíci

    Perfect, well explained thank you sir

  • @sarfrajahmad2850
    @sarfrajahmad2850 Před 3 lety +1

    You are fabulous sir

  • @saipraneethasp9847
    @saipraneethasp9847 Před 3 lety +1

    Sir, I just watched ur videos for ssc je mains.. tnx for this neat nd clean explanation sir.. Pls start Steel if possible..

    • @structuralanalysisanddesign
      @structuralanalysisanddesign  Před 3 lety

      Thank you for appreciating my lectures, yes i am starting design of steel structures in a very detailed manner very soon, keep watching and sharing with your friends

  • @armyofficermanishsharma5039

    Happy Navratri sir

  • @amansah9354
    @amansah9354 Před 3 lety +1

    tq very much sir for this video

  • @adityajoundal8500
    @adityajoundal8500 Před 2 lety

    Thanks sir 👌👍

  • @michaelshongwe9995
    @michaelshongwe9995 Před rokem

    Clear explanations, thanks 🙏

  • @NileshRoamingNITIAN
    @NileshRoamingNITIAN Před 3 lety +1

    Just Amazing 🔥🔥🔥🔥

  • @Anuradha135
    @Anuradha135 Před 3 lety +2

    Very Nice Video Sir 👍👍

  • @NehaNaaz-o6j
    @NehaNaaz-o6j Před měsícem

    Now a days using Fe 500,550
    Expecting design of rectangular footing on this subject

  • @RohitSingh-xb8ic
    @RohitSingh-xb8ic Před 3 lety +1

    How to know whether to use 2 legged stirrups or 4 legged stirrups

  • @nksconstructionworld2819
    @nksconstructionworld2819 Před 3 lety +1

    Thanks you sir

  • @masoodmomin5296
    @masoodmomin5296 Před 3 lety +3

    Thank you very much sir. What is live load you considered. Is it brick dead load of bricks. Also called as super imposed load

    • @structuralanalysisanddesign
      @structuralanalysisanddesign  Před 3 lety

      Yes overall live load

    • @masoodmomin5296
      @masoodmomin5296 Před 3 lety

      @@structuralanalysisanddesign we take live load Max upto 3 kn/m2 on slab. What is that load. Which taken as live load in problem.

    • @structuralanalysisanddesign
      @structuralanalysisanddesign  Před 3 lety

      Nowhere they had mentioned from where load was coming, its assumed overall load coming on beam say brickwork etc

  • @advselvaa5555
    @advselvaa5555 Před 3 lety

    Superb. Thank you sir.

  • @vkchowdary7924
    @vkchowdary7924 Před 3 lety +3

    Thank you sir, will you make video on Continuous slabs.

  • @amiteshsingh8682
    @amiteshsingh8682 Před 3 lety +3

    *Sir, can you upload videos of design of steel structure,bolted connection,joints,tension members and compression members?*

  • @sasikumartherayil9620
    @sasikumartherayil9620 Před 3 lety +1

    Sir
    Your efforts are good
    Go for IS Code
    Minimum mix is M25 for rcc.
    Now a days 415 steel is not available.
    Make it more practical by
    Bring a project in to it.
    So that the students will understand why it is a cantelever.
    Why it is starting from column.
    Tell how the load is coming.
    Shiw full details then come to the xantelever

    • @structuralanalysisanddesign
      @structuralanalysisanddesign  Před 3 lety

      Good suggestions, i will try to do it, but M20 is minimum mix for RCC as per IS Code and problem is solved as per IS code only

  • @gauravarya2419
    @gauravarya2419 Před 3 lety +2

    Hi sir, really loving all your videos. Could you please clear one of the practical doubt of the following case. It is for my home site. How do I extend a balcony of 1.2x2.5m of a preconstructed apartment using cantilever beams? It is a third floor. Column size is 9x12 inches. I am going to use 6 top bars of 16 mm and 3 bottom bars of 16mm, curtailing 2 top bars at 0.6m with the main slab bars of 12mm and distribution bars of 10mm. Stirrups bar of 8mm with spacing 4 inches center to center. cover block of 30mm with hook angle 135 degrees and angling downwards. slab thickness at support 6 inches
    As it is preconstructed apartment, I could not extend the bar back, however I have reclaimed around 0.6m beam and slab bars after demolishing beam and slab. Will this be enough for lapping length of slab and development length of cantilever beam. I plan to create a brick wall (4 inches, 9 feet ceiling height) to include this space inside to be used as a kitchen counter of 2 feet and overhead storage. What modifications I can perform to ensure safety.
    Total reinforcement area is now 3feet 6 inches cantilever, column(9″x12″), 2feet overlapping length.

  • @adityajoundal8500
    @adityajoundal8500 Před 2 lety

    Excellent 👍

  • @sheetal_baisa
    @sheetal_baisa Před 2 lety

    great efforts.

  • @FareedKhan-ec5iy
    @FareedKhan-ec5iy Před 3 lety +2

    First i would say, You are a true gem dear, appreciated your effort and the way you explain things A to Z, really really impressed. Keep this great channel going. My question is what if Tv

    • @structuralanalysisanddesign
      @structuralanalysisanddesign  Před 3 lety +2

      Thank you so much for appreciating me and for best wishes to the channel, this kind of motivating words keep me motivated to do videos, keep watching and supporting. To answer your question, if there is no need of shear reinforcement but still we have to provide minimum shear reinforcement in the form of stirrups, kindly refer IS 456-2000 Page 72, clause 40.3

    • @FareedKhan-ec5iy
      @FareedKhan-ec5iy Před 3 lety +2

      @@structuralanalysisanddesign Thanks for your answer. Sir will you provide a lecture on deep and hidden beam design if yes then expected time?

    • @structuralanalysisanddesign
      @structuralanalysisanddesign  Před 3 lety +2

      I cant guarantee but your request noted

  • @biswasmihir0001
    @biswasmihir0001 Před 2 lety

    Thank You Sir.
    Please give us a design calculation on rcc cantilever slab.

  • @amosopiyo6403
    @amosopiyo6403 Před 3 lety +1

    Good explanations and can you please upload a video on simply supported slab with cantilever on both sides

  • @vivekruthvik7468
    @vivekruthvik7468 Před 5 měsíci +1

    here before 3 days of my exam

  • @soimhossen3023
    @soimhossen3023 Před 2 lety

    Beautiful

  • @shanimat3003
    @shanimat3003 Před 3 lety +2

    Awesome!! Sir.....can u upload the lintel design?

  • @manikumar7501
    @manikumar7501 Před 3 lety +3

    sir, as the adopted reinforcement is Fe415 , after concluding the section as under reinforced why did you take Mu = 0.133 fck bd2. 0.133 is for Fe500 and for Fe415 we have adopt the formula Mu = 0.138 fck bd2.

    • @professor766
      @professor766 Před 4 měsíci

      Yaa, taken value of Mulim is wrong

  • @darshancalldarshu6413
    @darshancalldarshu6413 Před 2 lety +1

    Bro you can upload estimation long wall and short wall method and centre line method

  • @sumeetavhad7849
    @sumeetavhad7849 Před 3 lety

    Sir please make video on combined footings and structural analysis topic

  • @sumanbarat2281
    @sumanbarat2281 Před 2 lety

    I think d check is 0.138b D2 fck in place of 0.133 for fe415

  • @yuwabharatshakti3603
    @yuwabharatshakti3603 Před 3 lety +3

    Spacing of sturip remains constant in the middle of the beam or spacing decreases on the fixed portion।plz tell।

    • @structuralanalysisanddesign
      @structuralanalysisanddesign  Před 3 lety +2

      As the Shear force will decrease as you we go towards free end, spacing can be increased as you move towards free end, In this problem i have kept same spacing

  • @vikeshtalda1069
    @vikeshtalda1069 Před 3 lety +4

    Sir, while calculating the dead load, why be always multipy it by 25 ?

  • @brjangid3088
    @brjangid3088 Před 8 měsíci

    Is it not necessary to check against overturning moment.

  • @newera5773
    @newera5773 Před 2 lety

    Hello Sir!! Your explanation skills are outstanding. These are on the great videos of RCC design
    sir at 25:49 we use 2nd formula of tv am I right or wrong.

  • @nilakanthapanda4278
    @nilakanthapanda4278 Před 3 lety +1

    Deflection ?

  • @nepalitechnocrats5168

    How much % of main steel we should provide on bottom side (hanger bars)?

  • @vijaybhasker2928
    @vijaybhasker2928 Před 3 lety

    sir please make a video about design dog-legged rcc stair cases

  • @affu2104
    @affu2104 Před 2 lety +1

    In all problems u have not solved for check for development length..... Is it necessary to check or not..??
    Plz reply

  • @shashankda2002
    @shashankda2002 Před rokem

    Sir please upload tapered cantilever problem

  • @vikeshtalda1069
    @vikeshtalda1069 Před 3 lety +2

    Also sir, in some cantilever problem, I have seen, the addition of wt of rib, what is the formula for it, and what is rib actually?

  • @yangchinlhamu210
    @yangchinlhamu210 Před 3 lety +1

    Sir, the same problem in BC Punmai book ,they are not calculating effective span and have directly taken given length. Sir can you tell in cantilever problems excluding the given clear span problem, where we should calculate effective span and where not ?

  • @ARKK-ORGANIZATION
    @ARKK-ORGANIZATION Před 3 lety +2

    Sir this problem solved by LIMIT state or WORKING state method?

  • @shyamsundaryadav8752
    @shyamsundaryadav8752 Před 2 lety

    Sir, magnel method samjhadijyae naa

  • @DineshKumar-kd2nn
    @DineshKumar-kd2nn Před 11 měsíci

    In case of fe550 checking for deflection
    It's k=0.6
    L/d Max for cantilever is 7 xk=4.2
    Provided is 3000/450=6.667
    It's failing In deflection
    What should I do

  • @bimalkachhap9750
    @bimalkachhap9750 Před rokem

    Pl post the detail calculation sheet paper of design for RCC. cantilever beam, simply supported beam, overhanging beam.

  • @yangchinlhamu210
    @yangchinlhamu210 Před 3 lety +2

    Sir in some books b=0.5 D (overall depth) . And you are solving by b=0.5d (effective depth). Is it okay to use both ?

  • @arnabsikder5917
    @arnabsikder5917 Před 2 lety

    it is limit state or working state

  • @faizanuddin9272
    @faizanuddin9272 Před měsícem

    Sir you didn't divide shear force by 2
    Why ?

  • @ianballesteros6815
    @ianballesteros6815 Před 3 lety

    If Nominal Shear stress is bigger, does it mean Shear Design is not required? Do I still need to provide stirrups? And what will be the spacing if ever?

  • @petermapp5988
    @petermapp5988 Před 3 lety

    I love ALL...OF YOUR VIDEOS.As a do it yourselfer...without civil engineering background...in a world with persons who construct without civil enginerring and THE KNOWLEDGE from your channel...why when i talk..and can explain WHY...the changes must be made..the foreman gives me...THE EVIL EYE

  • @theexecutioner3510
    @theexecutioner3510 Před 2 lety

    Sir which bool did you refer for studying design of cantilever beam. Jain?
    Should I commit this solution?. Pls rply sir.

  • @samcivil9772
    @samcivil9772 Před 3 lety +1

    Sir if point load@end then how it is design

  • @AnkitMaurya-gs2po
    @AnkitMaurya-gs2po Před 7 měsíci

    Plz explain how will be b = 2d/3....🙏🙏🙏🙏

  • @alfavarghese1242
    @alfavarghese1242 Před 3 lety +1

    Can you explain more about negative moment and positive moment

  • @opendicharles3127
    @opendicharles3127 Před 3 lety

    can u also us how to do the curtailment. and also how to design to eurocode2

  • @emaaduddeen
    @emaaduddeen Před 9 měsíci +1

    sir how did you calculated hanging / bottom bars?

  • @MushtaqAhmad-ro9qm
    @MushtaqAhmad-ro9qm Před 2 lety

    Sir we have to design a beam of jib crane,plz sir if u cooperate with us , tomorrow we have a presentation about that....I will tell u about the required values etc

  • @shadabanwar6199
    @shadabanwar6199 Před 3 lety +1

    Sir please upload numerical on shear and bond and also design of doubly reinforced beam as soon as possible please sir it's humble request

  • @akashmadar3396
    @akashmadar3396 Před 2 lety

    What is nominal shear stress

  • @sathiyaprakash6382
    @sathiyaprakash6382 Před rokem

    Where we have implemented design widh

  • @srushtissathish3808
    @srushtissathish3808 Před 3 lety

    👍

  • @BeardMan1.
    @BeardMan1. Před rokem

    Can you change the clickpad 😊

  • @bhushankatore5868
    @bhushankatore5868 Před 3 měsíci

    Curtailment of bars are not provided

  • @atharavupare6479
    @atharavupare6479 Před 3 lety

    why the first stirrup inside the column?

  • @constructionvt9955
    @constructionvt9955 Před 3 lety

    Bro can u design the cantliver T beam..... With 6ft from wlla

  • @onlineteacher9171
    @onlineteacher9171 Před 3 lety +3

    Sir, From Which Book is page 37???

  • @rakshithvenkatesh9870
    @rakshithvenkatesh9870 Před 3 lety

    Hello Sir!! Your explanation skills are outstanding.. Thank u for such a neat/ detailed teaching.. huge respect!
    I just had one doubt sir.. at 40:09 u have taken the value as 1.6.. ( during the calculation of development length) , but i got the value as 1.92, can u please explain that step?
    Once again, Thank u soo much for such an outstanding lecture!!

    • @MissJYL0w
      @MissJYL0w Před 3 lety

      Yah me too..i'm wondering how he get 1.6..i also got 1.92

    • @petraalbatra9898
      @petraalbatra9898 Před 2 lety

      Actually the total value after multiplying 1.2 and 1.6 comes out to be 1.92. so the value coming out is same. I was also a lil bit confused at that point.

    • @civilengineering953
      @civilengineering953 Před rokem

      For HYSD bars we additional 60% i.e 1.6 ×1.2=1.92

  • @chrisk8z
    @chrisk8z Před 2 lety +1

    may i know what lvs stands for? ty

  • @gujjugamer7585
    @gujjugamer7585 Před 9 měsíci +1

    Which method is this WSM OR LSM

  • @oscarvaron4384
    @oscarvaron4384 Před 2 lety

    What Sizes support??

  • @Leo_Rocky_Rolex
    @Leo_Rocky_Rolex Před 2 lety

    Sir what to do if design moment exceeds limiting moment??

  • @yuwabharatshakti3603
    @yuwabharatshakti3603 Před 3 lety +1

    Why you have not cheak the development length that is come from 26.2.1to26.2.3.3c।plz tell sir।

  • @sprasanna1979
    @sprasanna1979 Před 2 lety

    PLS CORRECT MU LIMITING FOR 415 is 0.138 not 0.133

  • @Alpha_Dad
    @Alpha_Dad Před 2 lety

    Sir, why have you not considered tapering the section and curtailment of steel?

  • @saurabhrajputs
    @saurabhrajputs Před 3 lety +2

    U explained very well but there is 2 mistake one is major and one is minor
    1) U took 0.133(Fe500) instead of 0.138(Fe415)
    2) U didn't mention of clear cover and effective cover.
    PS: Plz do not get offend.

    • @structuralanalysisanddesign
      @structuralanalysisanddesign  Před 3 lety +3

      Thank you for telling the mistake yes its 0.138 i agree, i will put this correction in description box with timings, this is the first i made a mistake in my video and thanks again for letting me know, and as far as possible one can take minimum effective cover.
      Keep watching and keep sharing

  • @sarttfft
    @sarttfft Před 2 lety

    I am going to make 5 ft length of cantilever beam. Size of column = 10'' x12".
    Any suggestions on placing of reinforcement, developmental length and hidden beam?..

    • @structuralanalysisanddesign
      @structuralanalysisanddesign  Před 2 lety

      I strictly suggest you to consult your local structural engineer

    • @sarttfft
      @sarttfft Před 2 lety

      @@structuralanalysisanddesign if you dont mind, can you able to help me somewhere or the other way?

  • @vanand9888
    @vanand9888 Před 3 lety

    Coad book 📚 explanchai sir

  • @aquibmohd
    @aquibmohd Před 3 lety

    20:16 how to get this formula ?

  • @somnathmukherjee5794
    @somnathmukherjee5794 Před 3 lety

    Please upload a file of equal combined footing design.

  • @chandanraj7095
    @chandanraj7095 Před rokem

    Shear ke calculation me clear span lete hai

  • @sushilsawant6688
    @sushilsawant6688 Před rokem

    😢

  • @multicolor10
    @multicolor10 Před 3 lety +1

    Interesante presentación profesor. Solo intento aportar un vídeo dejo link sobre algunos aspectos. czcams.com/video/gIRrSVT_xLY/video.html

  • @gnaneshpramanik5982
    @gnaneshpramanik5982 Před rokem

    Lintel design

  • @adityatendulkar1130
    @adityatendulkar1130 Před 2 lety

    This is wrong