Video není dostupné.
Omlouváme se.

MSA Training in Hindi/NDC/Variable MSA/Core Tools/QDS/ Quality Documents Solution

Sdílet
Vložit
  • čas přidán 16. 08. 2024
  • Please subscribe the channel and click lick as given below for watching more videos
    IATF 16949 Awareness
    • IATF 16949/ISO/TS/1st ...
    VSA T2 Checklist (Part-1)
    • VSA T2 Audit Checklist...
    VSA T2 Checklist (Part-2)
    • VSA T2 Checklist (Part...
    VSA T2 Checklist (Part-3)
    • VSA T2 Checklist (Part...
    Change Management
    • 4 M Change management ...
    MARU-A (Safety Parts)
    • MARU A/Special Charact...
    Types of Audit
    • Types of Audit in hind...
    *New Control Plan as per IATF 16949:2016
    • Control Plan in Hindi/...
    APQP - Advance product quality planning
    • APQP Training in Hindi...
    PPAP- Production Part Approval Process
    • PPAP Training in Hindi...
    *New FMEA- Failure Mode & Effect Analysis- 1st Edition
    • New FMEA(AIAG - VDA)/F...
    MSA- Measurement System Analysis
    • MSA Training in Hindi/...
    SPC-1 Statistical Process Control
    • SPC Training in Hindi/...
    SPC-2 Statistical Process Control
    • SPC Training in Hindi/...
    7 QC Tools
    • 7 QC tools in hindi/7 ...
    If there is any training required in your organization,
    please mail us on
    isovipinmandal@gmail.com
    or
    visit us on
    www.qualitydoc...

Komentáře • 65

  • @nileshkokane7180
    @nileshkokane7180 Před 3 lety +3

    Very simple language are used for presenting MSA......thanks sir for understanding MSA in simple ways..
    ...

  • @rightvision1522
    @rightvision1522 Před 5 měsíci

    Thank you very much Sir,

  • @Bikash88
    @Bikash88 Před 2 lety

    Nice teaching way

  • @RadheRadhe-tq3ys
    @RadheRadhe-tq3ys Před 4 lety +2

    Very nice. Basic concept of msa is explained in very easy form

  • @GaneshKumar-fr9jz
    @GaneshKumar-fr9jz Před rokem

    Lots of thanks 🙏🙏🙏 Sir

  • @deepakrajput3134
    @deepakrajput3134 Před 3 lety

    Very usefull video

  • @rahulhire2690
    @rahulhire2690 Před rokem

    dear sir, very respectful of you - so happy after watching this video. concept are clear about NDC

  • @pawanjangra3051
    @pawanjangra3051 Před 4 lety +1

    Great explain... NDC confusion totally cleared.... thank you sir

  • @Rakeshkumar-ou9ic
    @Rakeshkumar-ou9ic Před 3 lety

    Thank you sir plz update attributes variable video

  • @satyendramaurya6685
    @satyendramaurya6685 Před 3 lety

    Thanks sir

  • @omkarsingh3320
    @omkarsingh3320 Před rokem

    Dear sir
    Explain the alluminum composition effects on casting defects and plz explain good effect and bad effect on casting

  • @bhupendrarajput8596
    @bhupendrarajput8596 Před 3 lety

    Thanks you sir for the information

  • @ajayphad2306
    @ajayphad2306 Před 4 lety +1

    Nice explanation sir!

  • @vinaypathak4980
    @vinaypathak4980 Před 4 lety

    Thank you sir.... Video is amazing👍🏻...
    Can you please provide MSA GRR format.....
    Thank you once again sir

  • @pawannagarkoti1015
    @pawannagarkoti1015 Před rokem

    Sir please help me to know about gauge capability (cg and cgk) learning

  • @vivekanandpandey5348
    @vivekanandpandey5348 Před 7 měsíci

    Sir,
    We are manufacturer of stearic acid for a tyre company .
    We checks all the parameters like iodine value , acid value etc. by chemical titration method then how can we perform MSA.

  • @hariombhardwaj4231
    @hariombhardwaj4231 Před 4 lety +1

    Aap ki vedio bhut acchi hai sir. Mera ek question hai sir ki appraisers variation or equipment variation kitna hona chaiye ya kitna hota hai

    • @qualitydocumentssolution-q8183
      @qualitydocumentssolution-q8183  Před 4 lety +1

      Appraiser & equipment variations criteria not defined in MSA manual but logically it can be defined if equipment variations is greater than AV then the variation present in Equipment and if AV is greater than EV then the variation is present in AV .
      But the standard defined on R&R acceptance criteria.
      If R&R less than 10% the measurement system acceptable and Measurement system is whole thing you need to understand measurement system.

  • @nehashukla6542
    @nehashukla6542 Před 2 lety

    Sir,can u explain how many trial for MSA standard ???

  • @ravindragaikwad754
    @ravindragaikwad754 Před 4 lety +2

    Sir if we have 4 micrometer, but we mention in the control plan that measurement method by micrometer, in this case can we have to do msa for all micrometer Or any one of them.?

    • @qualitydocumentssolution-q8183
      @qualitydocumentssolution-q8183  Před 4 lety +3

      You can do MSA of any one micrometer but The range and least count should be same means equipment should be from same family.
      In case the range and LC are differ then you have to do MSA for all measuring equipment

  • @atultyagi3299
    @atultyagi3299 Před 4 lety

    So Informamative session 😊,
    Sir may you provide ppt link so that we would download it ?

  • @kalpanasingh8299
    @kalpanasingh8299 Před 2 lety

    In MSA Study ,How many Persentage of Part Varriation

  • @bhavnaacharya2254
    @bhavnaacharya2254 Před 3 lety

    sir msa grr value acceptable criteria me meet nahi hota

  • @bhavnaacharya2254
    @bhavnaacharya2254 Před 3 lety

    for forging

  • @zikrullahakhtar9735
    @zikrullahakhtar9735 Před 4 lety

    Sir yaha msa me Jo format ap gauge RR liye h wo excel me kaise likhete hai ye bataiye

  • @heenaeksambe3372
    @heenaeksambe3372 Před 4 lety +2

    When are you going to upload MSA for attribute data...may I know sir please?

  • @ravindragaikwad754
    @ravindragaikwad754 Před 4 lety

    Sir how to decide reference value in linearity and bias study???

  • @manojmishra5445
    @manojmishra5445 Před 11 měsíci

    Dear Sir Can you please send me format of Guage Repeatability and reproducibility data collection sheet

  • @shubhampal6497
    @shubhampal6497 Před rokem

    Sir msa 3 word ka hindi definition bta dejiya m,s,a, ka matlab

  • @heenaeksambe3372
    @heenaeksambe3372 Před 4 lety

    Thank you so much for sharing.... Amazing video...
    I have two doubt..
    1. While doing GRR study, do we have to inspect on the same location Or in 90°.. especially for bore reading ?
    2. Can we have to do MSA on all measuring equipment including CMM? What does about destructive test measurement reading (material yield )?
    Thank you in advance

    • @qualitydocumentssolution-q8183
      @qualitydocumentssolution-q8183  Před 4 lety +1

      1. You have to measure on different locations but in some case you can measure on same location.
      2. If you have defined control method in Control plan the you have to do MSA as per defined measurement & test equipment .
      But the Measurement equipment you will select family wise If you have 5 micrometer and its range 0-25 & least count 0.001mm then you can take anyone for MSA study. No need to take all micrometer because the family is same.
      Thank you

  • @supriyobanerjee9081
    @supriyobanerjee9081 Před 2 lety

    Can someone explain me NDC calculation with an example:
    NDC= 1.41 (PV/R&R).
    How to get PV & R&R value

  • @mihirpandya8477
    @mihirpandya8477 Před 4 lety

    sir, can we Compare Cp, Cpk = Accuracy, precision??
    and Bias , linearity and stability Study is mandatory or not..???

  • @Dodu_Entertain
    @Dodu_Entertain Před 2 lety

    Sir 200 Ni
    I think 20 banegi

  • @nehajogdand760
    @nehajogdand760 Před 4 lety

    What action need to take if msa fails in case of AP n EV ?? What action need to take if part variation is more than equipment variation and apprisal variation

    • @heenaeksambe3372
      @heenaeksambe3372 Před 4 lety

      Action to be based on value of AV or EV....
      If AV- check whos value is higher like wise... One of action is Training.. and need to do again MSA.
      If ev - check where it showed higher ... Replace, repair..
      Sir will add some more into it...

    • @qualitydocumentssolution-q8183
      @qualitydocumentssolution-q8183  Před 4 lety

      First you have to See that if R&R is not acceptable then you need to take action now you need to analyse (through cause and effect analysis) that what is the actual cause of failure of R&R (Appraiser, Equipment, Environment, Method etc) . If you find actual cause then you need to take action on that.

  • @abis1326
    @abis1326 Před 4 lety +1

    What is the Difference between Pareto and histogram

    • @qualitydocumentssolution-q8183
      @qualitydocumentssolution-q8183  Před 4 lety

      Both are bar chat but there is huge difference between Pareto and Histogram
      Pareto chart used to show the defect data in descending order.
      But Histograms are used to show distributions of variables.
      And for more clarification you can watch video as already uploaded

    • @abis1326
      @abis1326 Před 4 lety +1

      Can you send that link

    • @qualitydocumentssolution-q8183
      @qualitydocumentssolution-q8183  Před 4 lety

      czcams.com/video/JFAdbKUYBAg/video.html

    • @qualitydocumentssolution-q8183
      @qualitydocumentssolution-q8183  Před 4 lety

      czcams.com/video/96HuQ39LNaI/video.html

    • @abis1326
      @abis1326 Před 4 lety

      I want separate video on difference between Pareto and histogram

  • @Beingstar_
    @Beingstar_ Před 11 měsíci

    Sir pls share this ppt

  • @ravindragaikwad754
    @ravindragaikwad754 Před 4 lety

    How to decide for which instrument we have to do which study??

    • @qualitydocumentssolution-q8183
      @qualitydocumentssolution-q8183  Před 4 lety

      See the given spec. is 5.0+0.3 then what measuring equipment you will select for inspection (0-25mm) and LC 0.001.
      You have to decide it yourself

    • @ravindragaikwad754
      @ravindragaikwad754 Před 4 lety

      It's ok sir but I want to know that for micrometer we will do GRR study, like that can we do GRR for vernier also or can we do bias for vernier.

    • @qualitydocumentssolution-q8183
      @qualitydocumentssolution-q8183  Před 4 lety +1

      GRR study is mandatory
      But you can do Bias study also

    • @ravindragaikwad754
      @ravindragaikwad754 Před 4 lety

      Sir will you please make a video on graphical analysis of msa studies to understand the results by seen the graphs.

    • @qualitydocumentssolution-q8183
      @qualitydocumentssolution-q8183  Před 4 lety +1

      Ok will make soon

  • @zikrullahakhtar9735
    @zikrullahakhtar9735 Před 4 lety

    Sir apki koi in-house training center h

    • @qualitydocumentssolution-q8183
      @qualitydocumentssolution-q8183  Před 4 lety

      Yes but it is closed now due to Covid-19 you can join my online training program
      Join us on Facebook
      facebook.com/Quality-Documents-Solution-105064617608142/