Branch Reinforcing Pad Calculation | ASME B31.3 | Example | Piping Mantra |

Sdílet
Vložit
  • čas přidán 21. 08. 2024

Komentáře • 24

  • @ansarbaig7183
    @ansarbaig7183 Před 2 lety +3

    I am piping Designer and I worked in JGC Japan. I enjoy watching your video as these are interesting and similar to my interest.

  • @sambitp634
    @sambitp634 Před 2 lety +2

    Your valuable information is helping me a lot.Thanks a ton

  • @vivekpatel1483
    @vivekpatel1483 Před 3 lety +1

    Madam, your video is very good

  • @pankajkumar-hr5ok
    @pankajkumar-hr5ok Před rokem

    Good explanation.
    I am so think that if A1 is more than (A2 +A3) then branch reinforcement is required otherwise not. Because A4 is adding to make A1

  • @ahmedanwar4586
    @ahmedanwar4586 Před 2 lety

    Good explanation thanks for your efforts

  • @Suriyapandi.Pitchaimuthu
    @Suriyapandi.Pitchaimuthu Před 5 měsíci

    Thanks for good information

  • @adnannasirvlogs7241
    @adnannasirvlogs7241 Před 10 měsíci

    Very well explained, please make video on impact testing

  • @paritoshpratap87
    @paritoshpratap87 Před 3 lety

    Informative for non designers...

  • @AHMEDALI-rq7jg
    @AHMEDALI-rq7jg Před 2 lety

    very helpful video, than you

  • @AUSSIEMALAYALI2024
    @AUSSIEMALAYALI2024 Před 3 lety +1

    Pump head and pump calculation expected next .thank you

  • @qurankatarjuma397
    @qurankatarjuma397 Před rokem +1

    Dear mam, please make a video regarding Impact test requirements per ASME B31.3

  • @AUSSIEMALAYALI2024
    @AUSSIEMALAYALI2024 Před 3 lety +1

    Great

  • @KarTiratna
    @KarTiratna Před 5 měsíci

    Pl note that the value of L4 selected in Area A3 calculation (example) must be lesser value from 62.5 & 52.5mm whereas 62.5 is selected in calculating A3. It seems to be corrected.

  • @joissreenivas
    @joissreenivas Před 3 lety +3

    In order to calculate A3, two values of L4 of 62.5mm & 52.5mm are calculated and lesser of the two values(52.5mm) is to be used and same is said in explaining but in the example shown 62.5mm is used which is wrong.

  • @lotustweeys
    @lotustweeys Před rokem

    Padding is required in support?

  • @MerajKhan-dn8xo
    @MerajKhan-dn8xo Před 2 lety

    Total area of reinforcements is greater hence Rf pad is not required please clarify based on ur video u said while explaining only formula

  • @umeshbalsaraf6549
    @umeshbalsaraf6549 Před 3 lety

    Is it same for pressure vessel ?

  • @YogeshKumar-hu7dh
    @YogeshKumar-hu7dh Před 3 lety

    Can you share calculations pdf ?

  • @bijubhaskar2407
    @bijubhaskar2407 Před 2 lety

    d2=(Tb-c)+(Th-c)+(d1/2)....its not (Th+c) as mentioned in the video.... Please refer the code