  • This is a video to address some very common questions I get - What's the lowest wattage it can run at? Does it run on cloudy days? Does it need to be reset after it shuts down due to low power? I address all of these questions in this video.
    Get a $50 discount from Signature Solar on ordered over $500 with the code SmitHVAC
    EG4 Solar heat pump with pre-charged lines:
    signaturesolar.com/?ref=_KvVr...
    Join my Solar heat pump group!
    m. groups/7456267...
  • Auta a dopravní prostředky

Komentáře • 246

  • @SmitHVAC.
    @SmitHVAC.  Před rokem +4

    EG4 Solar heat pump with pre-charged lines:
    signaturesolar.com/?ref=_KvVrzchAclARI

  • @mdunbar04
    @mdunbar04 Před rokem +17

    Best explanation video on CZcams about the EG4 mini splits. 👍👍👍

  • @rccrashed
    @rccrashed Před rokem +19

    Very informative video, the first one I have seen demonstrating how low of solar power you can actually run down to. Thanks for making these videos!

    • @SmitHVAC.
      @SmitHVAC.  Před rokem

      You're welcome! Thanks for watching!

  • @ibenglish
    @ibenglish Před 7 měsíci +2

    That’s some very good information on the mini split. Good job explaining things 👍🏻

  • @kansasadventure1831
    @kansasadventure1831 Před měsícem +2

    I need to revisit this video at a future date. Thanks for posting.

  • @phxBird
    @phxBird Před 6 měsíci +1

    Thanks for the ac limiter setting information.. I’ll start using that option on my second summer using E4 unit to keep my man shed cool in the Arizona summer months as I unplug unit during winter months as the unit warm up man shed nicely during the day to keep in the warmth during the 12 hours of no power from solar during the winter here in Arizona. Nice video!! Thanks 🙏🏻

  • @scottramey3371
    @scottramey3371 Před rokem +3

    I hope you get in on the ground level of these hybrid systems! There is a ton of potential and your videos are awesome to help others. I’m contemplating getting their 24k diy unit if it is as good as you say it is. Especially being in Minnesota.

    • @SmitHVAC.
      @SmitHVAC.  Před rokem

      Thanks! I really like mine, I'll be helping a family member install 2 of the new DIY versions in a month or so, so keep an eye out for that video. The 24k is on backorder right now so they're taking orders first come first served.

  • @andys5203
    @andys5203 Před 5 měsíci +1

    Awsome presentation, sir 👏

  • @ramhammer10-4
    @ramhammer10-4 Před 11 měsíci +1

    Thank you for that detailed information.

  • @davidcoffey6413
    @davidcoffey6413 Před rokem +2

    Very interesting video. Thanks, I didn't realize the app had so many features.

    • @SmitHVAC.
      @SmitHVAC.  Před rokem

      It's a pretty good app! Thanks for watching.

  • @JohnBaker3000
    @JohnBaker3000 Před rokem +1

    Excellent! Great explanation! Thank you.

  • @OFFGRID_Trucker
    @OFFGRID_Trucker Před 11 měsíci +1

    I installed a 9k pioneer last summer here in my '28 RV. They are super efficient on power and whisper quiet.. There inverter type mini splits were just coming out but expensive as well. I'm saving to buy some land and go offgrid.. looks like I'll be replacing it. After the fact, I want a 12k upgrade.. so it'll work out.

  • @PreppinontheCreek12
    @PreppinontheCreek12 Před 11 měsíci +1

    Very good video with lots of info. Thanks for sharing.

  • @forester057
    @forester057 Před rokem +1

    Learned a lot. Thanks

  • @verohandymike
    @verohandymike Před 2 měsíci +3

    I can't afford one right now, but this explanation is what makes me want to buy one, and I will soon. I am off grid in Jamaica and have a little window unit that does OK with the setup I have, but it does require a lot of manual adjustments for me. I will wait until the SOC is at 100%, usually around 11am, then turn it on. Typically when the day is sunny I can go until 4-5PM and still be 100%, then I either turn it off or make up my mind to run on battery into the night. I think I'll get this EG4 mini split and have it run independent of the system I have now, even if I have to get it's own battery, just so I really can run it without any concern about it pulling from my current setup. A big bonus is how low watts it will run at, in sunny Jamaica I see no problem using this unit.

  • @TopShotDustin
    @TopShotDustin Před 4 měsíci +1

    So for least power consumption of an empty house maintenance, would AC Limiter or Dry mode best?

    • @SmitHVAC.
      @SmitHVAC.  Před 4 měsíci

      I'd probably use Ac limiter

  • @1turf32
    @1turf32 Před rokem +1

    Video thanks for answering those questions now I know. Stay cool

  • @stacyhackney6100
    @stacyhackney6100 Před 2 měsíci +1

    Thank you

  • @mossup-
    @mossup- Před 11 měsíci +1

    Definitely A good video, thankyou ♥

  • @slip0n0fall
    @slip0n0fall Před rokem +1

    This is awesome, thanks. I have been thinking about asking all the questions answered here. I basically have a 2car garage that i don't really want to pay the electricity to heat/cool, but if it's purely *solar*...

    • @SmitHVAC.
      @SmitHVAC.  Před rokem

      Thanks for watching, I just found out the 24ks are on back order. 12ks are available but 24k is preorder with availability in Sept.

  • @Ed123
    @Ed123 Před rokem +1

    Very interesting. Thanks.

  • @mckrunchytoast2469
    @mckrunchytoast2469 Před měsícem +2

    I've been looking at this playlist and I started at your 1 year video for the EG4. I'm doing a "skoolie" build and I think this would be a fantastic solution to my cooling needs over a traditional mini split. I hope you see this because I would love your input on what you would say the Minimum amount of Wattage would recommend dedicating to the EG4. I'm going to dedicate a percentage of my panels for the EG4 then the rest for my battery bank. love your vids you've got a new loyal subscriber now!

    • @SmitHVAC.
      @SmitHVAC.  Před měsícem +1

      I'd give it at least 1200 and try to be over 150vdc

    • @mckrunchytoast2469
      @mckrunchytoast2469 Před měsícem +2

      @SmitHVAC. I absolutely appreciate that. I'll definitely keep watching your whole Playlist and taking notes. Heck I'll end up watching all your videos before it's said and done. Thanks a million!!

    • @SmitHVAC.
      @SmitHVAC.  Před měsícem +1

      @@mckrunchytoast2469 thanks for watching!

  • @BlackGuyDIY
    @BlackGuyDIY Před 10 měsíci +1

    Great video.

  • @DaddyEric222
    @DaddyEric222 Před 11 měsíci +1

    Wow! That’s efficient! The 9.5k btu unit I put on my campervan pulls 1000-1250 watts… works well but even with my 15kwh battery it dies in about 12-24 hours. Good for what I needed though.

    • @SmitHVAC.
      @SmitHVAC.  Před 11 měsíci

      It is very efficient! Sounds like a nice setup you have

    • @mikemotorbike4283
      @mikemotorbike4283 Před 10 měsíci

      maybe on startup. should amble along at 500w when it finds your temp, unless you're sitting in hell's canyon. check again. are you trying to heat a tourbus?

    • @DaddyEric222
      @DaddyEric222 Před 10 měsíci

      Lowest I've watched it pull while the compressor was running is about 750-800 watts. I have Victron shunts to measure the power. It pulls 80 watts just to run the indoor fan. @@mikemotorbike4283

  • @mycabinlife1291
    @mycabinlife1291 Před 8 měsíci +1

    It would be a great video if you did the same exact test but using the Heat and the power station again LOL

  • @mizaelnoriega9301
    @mizaelnoriega9301 Před rokem +3

    Very good videos! Im going to buy serval of these EG4 units thanks to your reviews. I have 4K watts worth of panels i havent installed in a array yet so they will be perfect for this setup! Easy plug n go.

    • @SmitHVAC.
      @SmitHVAC.  Před rokem +1

      That's awesome, I'm glad to hear it. It's a great system! I'd appreciate if you used my link, helps me keep the videos coming!

    • @mizaelnoriega9301
      @mizaelnoriega9301 Před rokem +1

      @@SmitHVAC.i will, im thankful i found your channel👍

    • @SmitHVAC.
      @SmitHVAC.  Před rokem +1

      @@mizaelnoriega9301 Thanks so much! I'll have another video coming Saturday

  • @ShaneS071
    @ShaneS071 Před rokem +1

    great informative video, you say it takes about 150-160 watts to restart, did you take note of the voltage at the time of restart

  • @jamespierce8157
    @jamespierce8157 Před rokem +1

    I purchased the EG4 24,000 BTU unit. with it in A/C inhibitor mode my runs at approximately 750 watts at the peak part of the day, according to the app on my phone.

    • @jamespierce8157
      @jamespierce8157 Před rokem +2

      In normal mode my unit will run at 2600 watts when it is at the peak of the day (102'F)

    • @SmitHVAC.
      @SmitHVAC.  Před rokem

      Sounds like it's working good!

  • @paulpurcell5658
    @paulpurcell5658 Před 11 měsíci +2

    Great video, I have a 24v system currently running a Mitsubishi air conditioning worried about my batteries life span agm this could be a great fix Paul

    • @SmitHVAC.
      @SmitHVAC.  Před 11 měsíci

      Hard to beat a Mitsubishi but yes if your batteries start to fail you can install one of these for the same price as a few batteries

  • @danortiz51
    @danortiz51 Před 5 měsíci

    What's the square footage of the room you have in it

  • @constructionbeforesandafters

    Your video helps alot ..I was just wondering how many solar panels should I use , how many watts to total

    • @SmitHVAC.
      @SmitHVAC.  Před 2 měsíci

      Right now I have 6 panels at 280 volts DC 1250 watts. Will be switching them out for 4 panels at 160v 1600w

  • @FakeName39
    @FakeName39 Před měsícem +1

    this is exactly what i been looking for, I want a couple solar mini splits, and i live in a desert. It rains like 3 days a year, so i have A LOT of sunshine, but when its summer its 110+ on average. At night 11PM it is still 95, so then okay great, i got solar splits for the day but how in the world do i keep them going at night time as well. One thing I am wondering about is how long are these things supposed to last?

    • @SmitHVAC.
      @SmitHVAC.  Před měsícem

      I just got a 6000xp to run my 2 minisplits through the night, it's a little pricey but it's an amazing system. Avg minisplit life is 7 to 10 years, depends if you want to fix it or replace it when something major breaks.
      signaturesolar.com/eg4-wallmount-indoor-battery-280ah-51-2v-14-3kwh-eg4-6000xp-off-grid-inverter-bundle-8000w-pv-input-6000w-output-all-in-one-solar-inverter-bndl-e0009/?ref=_KvVrzchAclARI

  • @ClarksAutoAndPerformance

    I'm struggling to get my unit to connect to the app.

  • @shephusted2714
    @shephusted2714 Před rokem +1

    it looks like you could run the heat pump plus recharge batteries on 3-4 panels - good look at system!

    • @SmitHVAC.
      @SmitHVAC.  Před rokem

      Panels are definitely the next upgrade, thanks for watching!

  • @Ulbre
    @Ulbre Před 10 měsíci +1

    Interesting and informative video. Is this the 24K BTU version?
    Do you have any info on typical overnight energy use, especially if running off batteries.

    • @SmitHVAC.
      @SmitHVAC.  Před 10 měsíci +1

      This is the 12k btu. It really depends on the temperature you're trying to achieve and the outdoor temp, it can ramp down as low as 200w or as high as 1300w so it's hard to put a number on the power consumption.

  • @extendedp1
    @extendedp1 Před měsícem +2

    Thanks for the video. Would one of these work for a walk in insulated cooler room or root cellar to store food? People make those with window AC’s, they trick the temp sensor so it runs constantly, getting the room colder than designed. I guess you would need to start with an AC that can put out 40F air to start with though. Thanks

    • @SmitHVAC.
      @SmitHVAC.  Před měsícem +1

      I've seen a few people hook the coolbots up to minisplits, definitely more common on the window AC's but this would work.

    • @extendedp1
      @extendedp1 Před měsícem

      @@SmitHVAC. thanks

  • @czexybeast
    @czexybeast Před rokem +2

    How much efficiency are you getting off the Victorian vs the built in MPPT? Really digging this series, BTW.

    • @SmitHVAC.
      @SmitHVAC.  Před rokem +1

      Thanks Damon! I haven't calculated it but the victron definitely does a better job. I only have one panel hooked up to it right now. Upgrades coming soon!

  • @michaelbravo3866
    @michaelbravo3866 Před rokem +1

    sweet

  • @yamafanboy
    @yamafanboy Před měsícem +1

    With the AC limiter option selected while running dehumidification mode simultaneously how many hours of runtime can you get on battery only? ( just trying to work out how far an ecoflow delta pro will get me overnight tbh lol)

    • @SmitHVAC.
      @SmitHVAC.  Před měsícem +1

      Depends how much battery you have, it runs just under 200w so 12hrs = 2400wh

  • @user-vb5ud2vs2r
    @user-vb5ud2vs2r Před 10 měsíci +1

    For L,N wiring. can you link what you used? To power it through AC power.
    L,N means live (hot) and N (neutral), correct? I am not asking about the gauge, but rather the cabling.
    I was wondering if I could just cut an extension cable and use those wires given that it has the appropriate gauge wiring

    • @SmitHVAC.
      @SmitHVAC.  Před 10 měsíci

      Technically it should be Nmw 14G for outdoor use but yes, L is line voltage, N is neutral

  • @Deveak
    @Deveak Před 11 měsíci +1

    Wish they would use this tech fit walk in coolers and freezers. Huge market.
    Can you oversize the array fit consistent performance or would that damage it?

    • @SmitHVAC.
      @SmitHVAC.  Před 11 měsíci

      As long as you don't exceed the max voltage you'll be fine

  • @JonOffgrid
    @JonOffgrid Před rokem +1

    😎👍

  • @gormanthomas8135
    @gormanthomas8135 Před rokem +1

    I’m a new subscriber. Nice videos. I’m getting output temps in the low to mid 30 degrees range (F) on my 2 Pioneer mini splits. I was kind of surprised by the temp outputs in the video. I am in AZ. Maybe low humidity helps??

    • @SmitHVAC.
      @SmitHVAC.  Před rokem +1

      Thanks for subscribing! That's pretty cold, typically you should see a 20 to 25f temp drop through the unit so it depends on your indoor temp, how many btus and the size of the space, but it sounds like it's working well!

    • @gormanthomas8135
      @gormanthomas8135 Před rokem +1

      @@SmitHVAC. Ah ok. That makes sense. Thx! Looking forward to more awesome content. 👍

  • @ramonstinedurf5691
    @ramonstinedurf5691 Před 3 měsíci +1

    If you we’re totally off grid or a grid down situation could the unit be run off the battery bank and inverter?

    • @SmitHVAC.
      @SmitHVAC.  Před 3 měsíci

      Yes. I have a few videos running it on an inverter and batteries

  • @911aDay
    @911aDay Před rokem +1

    Do you know if the EG4 split has an open API would like to monitor with my other home automation? Thanks for this!! ☀

    • @SmitHVAC.
      @SmitHVAC.  Před rokem

      I believe it does, there are a few pages of home automation settings in the app

  • @zgomez68
    @zgomez68 Před 3 měsíci +1

    Does the unit need a dedicated solar panel? Or can the panel also be connected to your battery bank at the same time?

    • @SmitHVAC.
      @SmitHVAC.  Před 3 měsíci

      Dedicated. You might be able to connect it to both of you got creative..

  • @phxBird
    @phxBird Před rokem +1

    I love mine, the only issue I had was swiping up to see my data I accidentally hit the heat button taking it off cold. I thought it was broken but it was actually me that was broken 😂

    • @SmitHVAC.
      @SmitHVAC.  Před rokem

      😂 It happens to the best of us

  • @silverlex1
    @silverlex1 Před 3 měsíci +1

    Did you do something special to get 2 liquid tight cables on the outdoor unit? Our EG4 minisplit has MC4 connectors for the solar input (and i'd rather all the wiring be in liquid tight conduit).

    • @SmitHVAC.
      @SmitHVAC.  Před 3 měsíci +1

      This is the first generation version without the precharged lineset, they had internal Mc4 connectors but it's a tight squeeze in there

    • @silverlex1
      @silverlex1 Před 3 měsíci

      @@SmitHVAC.thanks for following up! I may see if we can convert it to internal connectors, external mc4 just seems less professional.

  • @dl7481
    @dl7481 Před 5 měsíci +1

    I just did a dyi install, the green icon shows in my minisplit but the app shows no pv wattage. Its running off ac voltage at the moment. I have 5 34v panels in series. I have 170v feeding the condenser. But have 0 watts being showed on the app

    • @SmitHVAC.
      @SmitHVAC.  Před 5 měsíci

      That's odd. Is the polarity correct? If you disconnect the AC power does it work at all?

  • @siarlbychan
    @siarlbychan Před 2 měsíci +1

    Thank you for this wonderful video on the EG4 Hybrid A/C. I purchased the 12000 BTU but have not set it up yet. Still need to purchase the solar panels. Which is my question. I had listened to another youtuber introduce this almost two years ago and he stated that he had x4 400 watt solar panels and that you would need at least that much to run it during the day with no problem. Would you say that is about correct with your experience where you are? The math equation when calculating solar and the technical jargon are not my specialty. You demonstrated that 140 watts coming in would be the bare minimum? How does that translate to what I would need in regards to solar panels? The x4 400 watt minimum? Thanks again.

    • @SmitHVAC.
      @SmitHVAC.  Před 2 měsíci

      4 x 400w is the perfect number for best efficiency, you can get away with less but most people like to connect the maximum allowable solar so it can run better in poor sun conditions

    • @siarlbychan
      @siarlbychan Před 2 měsíci

      @@SmitHVAC. Thank you so much for your perspective. That will be what I shoot for then. Have a great day and keep the videos going!

  • @gg-gn3re
    @gg-gn3re Před 8 měsíci +1

    If you have no service at your house keep your phone on airplane mode and it'll get like an extra 1-2 days of battery (still can connect to wifi while in airplane)

  • @SynthToshi
    @SynthToshi Před 25 dny +1

    what if you have no ac hooked up? can you run the ac with just solar?

    • @SmitHVAC.
      @SmitHVAC.  Před 25 dny

      @@SynthToshi yes it will run on either, or both

  • @2239968
    @2239968 Před rokem +1

    What happens when the unit doesn't have enough solar to run? Is the switch to grid immediate or is there a delay?

    • @SmitHVAC.
      @SmitHVAC.  Před rokem

      It's immediate, it will start adding grid power before the solar gets too low

  • @genfari9522
    @genfari9522 Před měsícem +1

    if you don't have batteries will it run a lot on hot days, all day? I know it wouldn't run at night, but do you think it would run most of the day on a sunny day? I so want to get one of these in Florida, we have a lot of power outages during hurricane season, but can't afford the battery system. I was thinking of badding extra solar panels because I won't have batteries. Do you also know for this exact system you have about how many panels would be good?

    • @SmitHVAC.
      @SmitHVAC.  Před měsícem

      Yes, that's the best part about these, You can run them on panel only. I have mine running all day, every day on 6 panels. It usually switches over to household power around 730pm

    • @genfari9522
      @genfari9522 Před měsícem

      @@SmitHVAC. Thank you so much for you reply. I have some good battery fans for overnight if needed.

  • @paulpurcell5658
    @paulpurcell5658 Před 11 měsíci +1

    Also just wondering if I would have to get more panels, i have 3× 330 watt panels Paul

    • @SmitHVAC.
      @SmitHVAC.  Před 11 měsíci

      You could get away with 3 but you'd probably want 1 more to make the most of the evening and cloudy day solar

  • @HotGritz910
    @HotGritz910 Před 4 měsíci +1

    Could i expect the same results with 12k btu 28.5 seer unit? I have a ac 200 L power station that i hope to run with mine, i have 1100 watts of solar on the roof of my bus but so far i have only seen a max of 500 watts.. my yard is tree heavy with shade.
    What watt does eco mode normally run on the eg4?

    • @SmitHVAC.
      @SmitHVAC.  Před 4 měsíci

      Should be pretty close. Is it 120v? Eco mode runs around 300w on heat and even less in cooling mode.

    • @HotGritz910
      @HotGritz910 Před 4 měsíci +1

      @SmitHVAC. yes, 120v 30 amp AC. I have (4) 20 amp ac plugs and one rv 30 amp plug. Im going to run the eg4 from one of those plugs with a 20 amp circuit breaker.

  • @Bruxollini
    @Bruxollini Před 6 měsíci +1

    Can you make the same video but about heating in the winter? Also, how many panels do you have powering this system? Thank you!

    • @SmitHVAC.
      @SmitHVAC.  Před 6 měsíci +1

      I plan to at some point! I have 6 230w panels installed right now, will be swapping them out for 4 400w panels soon

    • @Bruxollini
      @Bruxollini Před 6 měsíci +1

      @@SmitHVAC. I’m planing for around 1600 to 2000 watts of PV so I can use it in the winter, and plugging in for use at night and cloud days.

    • @SmitHVAC.
      @SmitHVAC.  Před 6 měsíci +1

      @@Bruxollini 1600w is the maximum input for a 12k

  • @GundamExia88
    @GundamExia88 Před rokem +1

    Nice video! Are the batteries running in parallel?

    • @SmitHVAC.
      @SmitHVAC.  Před rokem

      2 sets of 2 in series, parallelled together

  • @TheRmenke
    @TheRmenke Před rokem +1

    Are you using the Solar Aircon app from the QR code in the EG4 manual? I downloaded it, and it says it is not compatible with my Android version 11 smartphone.

    • @SmitHVAC.
      @SmitHVAC.  Před rokem

      I have heard that from a few people, I had no issues with a Samsung s9 or s20, even an older ZTE tablet. What country are you in?

    • @TheRmenke
      @TheRmenke Před rokem +1

      @@SmitHVAC. I'm in South Central Texas. My older cellphone runs the app., so it's o.k.

  • @wilmorris4225
    @wilmorris4225 Před 9 měsíci +1

    Dumb question here but still researching..this is the 12,000 btu correct? Is 12k the only AC/DC model? They do not make a 9000 BTU AC/DC? For my motorhome, 9k I think is ideal but it seems their 9K model is AC only.

    • @SmitHVAC.
      @SmitHVAC.  Před 9 měsíci +1

      That's correct, they make a 12k and a 24k in the solar hybrid model.

  • @bearupfarm1818
    @bearupfarm1818 Před rokem +2

    Hi Smith, I just wanted to ask if the 12K is as good as the 24K? Do they both run the same power consumption or does the 12k run more. I was just trying to get some information. I’m totally off grid with 48volt system. Thanks for your input.

    • @SmitHVAC.
      @SmitHVAC.  Před rokem

      They are almost identical but the 24k has twice the capacity of the 12k. It would use about double the power, just depends how big the space is that your trying to heat or cool.

    • @bearupfarm1818
      @bearupfarm1818 Před rokem

      Ok thanks.

    • @ryanyoder7573
      @ryanyoder7573 Před 11 měsíci +2

      12k runs on 120v 24k requires 240v split phase

    • @mikemotorbike4283
      @mikemotorbike4283 Před 10 měsíci

      9k most efficient, decreasing efficiency the higher you go, and adding extra heads decreases efficiency of a unit. I wonder if there are there are greater losses running two units over one with two heads. With two separate smaller units you get redundancy, ease of installation and repair. Adding more complexity to a single unit and cost of recharging (every 5 years recommended) because very high skill level required of tech who may not have a lot of experience working on a manifold.
      Just try to find a tech willing to work on your unusual Chinese brand, hybrid unit, custom install, unwarranteed DIY installation without having to trade your firstborn or get on the down-low with the Mayor to get: insurance, local permits, inspection certs and warranty requirements.
      With two smaller units with single heads there are configuration advantages through simplicity of installation and externalities relating to DIY install. Also, you could turn off one at night. Or only run both when you're on AC. But don't listen to me I eat meat.

  • @JWTX
    @JWTX Před rokem +1

    Does it harm the unit at all with the shutting on/off just in pv mode?... Also what are the voltage and Amos limits on the 12ik unit? ...Thanks..... Jeff

    • @SmitHVAC.
      @SmitHVAC.  Před rokem +1

      I don't think so, I think that's the reason it's a hard cutoff so it doesn't get down to a dangerously low level

    • @SmitHVAC.
      @SmitHVAC.  Před rokem +2

      Sorry Jeff I skipped over your voltage question, recommended voltage is 90-350 with a max of 380vdc. They don't specify a max amps in the manual.

  • @rocktman81
    @rocktman81 Před rokem +2

    Thank you so much for this video. Been watching some videos about combo/solar mini splits and I wondered how little of solar panel it would be possible to get by on for some occasional solar cooling and heating. So this means you could run this off 4 cheap 100W panels from Harbor Freight or Amazon then, huh? Can you please repeat this video in the winter and see approximately how many minimum watts are needed to heat? Thanks! I’m wondering/hoping that I can some day out 4 100W panels on the roof of a 7x7 resin shed to power one of these mini splits on solar only for portions of days. Wish they made a 9k BTU version that would use even less power to make this even more likely to be possible for me.

    • @SmitHVAC.
      @SmitHVAC.  Před rokem +3

      Thanks for watching! I can definitely repeat this in the winter, it does use quite a bit more power in heating mode. You could get away with some cheaper panels but make sure the voltage is high enough, it needs a minimum of 90V DC

    • @kameljoe21
      @kameljoe21 Před rokem

      Most people have said that around 1000 watts is the best to have with these units at the highest voltage that the spec sheet said.
      The most solar if I recall was around 3k and 300 volts or something like that.

    • @hanklinch2833
      @hanklinch2833 Před rokem

      There is a 9000 btu unit available

    • @kameljoe21
      @kameljoe21 Před rokem

      @@hanklinch2833 Is that EG4 branded or Deye? I was unaware that they had the smaller unit. Deye also carries a water heater with the same thing. Which would be quite cool to see how that works. On the water heater side I was thinking that if I had enough electric water heaters in a row I could preheat a lot of water. Yet the price of a 120 gallon water heater is expensive.

    • @rocktman81
      @rocktman81 Před rokem +1

      @@hanklinch2833 Do they have a hybrid/solar 9k available though? Thought they only had a 9k available that was a standard unit (not hybrid that can do solar power too)

  • @mrfuis0n
    @mrfuis0n Před 3 měsíci +1

    I installed thie 12k btu version a week or so ago and it works well. However, even with the temp set to minimun and fan on "turbo", i have not seen this unit pull more than 550W. I was expecting it to reach closer to the rated 1100W. Has anyone else seen this?
    I have about 600W of solar panels plus 120v ac hooked up to this. I do not have the limiter or eco modes enabled. Again, it works fine, i was just expecting a little more out of it.

    • @SmitHVAC.
      @SmitHVAC.  Před 3 měsíci

      Mine runs around the same but I have seen it pull more demand occasionally. It's all algorithm based, how quickly the indoor space is changing temp, how long its been at the current demand with no change etc.

  • @frankz1125
    @frankz1125 Před 4 měsíci +1

    Hi. Do you know where to get an eg4 solar mini split in Ontario Canada? Thanks for sharing. Cheers

    • @SmitHVAC.
      @SmitHVAC.  Před 4 měsíci +1

      signaturesolar.com/?ref=_KvVrzchAclARI
      I'm in Ontario too, where are you from?

    • @frankz1125
      @frankz1125 Před 4 měsíci

      @@SmitHVAC. gravenhurst

  • @kennethoh6928
    @kennethoh6928 Před 7 měsíci +1

    After waiting a month and half and shipping date kept getting pushed back, I’m giving up on hybrid eg4 and going with plan B…
    9k eg4 and small solar system with batteries. How much electricity storage do you think I need to safely run over night plus some cloudy days? I’m in Las Vegas, so sun is out most of year.

    • @SmitHVAC.
      @SmitHVAC.  Před 7 měsíci

      10kwh would be a good number, I use between 5 and 8khw per day depending on the temps

    • @2006mrderrickh
      @2006mrderrickh Před 5 měsíci

      @kwn Update?

    • @SmitHVAC.
      @SmitHVAC.  Před 5 měsíci

      1107kwh total, 370kwh from solar

  • @makehondagreatagain6357
    @makehondagreatagain6357 Před rokem +1

    How would I hook this up to solar and charge battery at the same time is that possible?

    • @SmitHVAC.
      @SmitHVAC.  Před rokem

      No you would need a separate array to charge a battery bank

  • @dominickthornburghakaTRG

    I live in texas and we get a lot of sun, but some shade over my house in the afternoon.
    How many panals and batterys to go totally off grid for this unit?
    Also if I had to up the watts how much bigger of an inverter would I need like a 2,000W ?
    I'd appreciate the help.
    Someday Id like to run my whole house on solar, but this would be a foot in the door. Thanks.

    • @SmitHVAC.
      @SmitHVAC.  Před rokem

      If you were going to go with a 12k btu like this I would go 1600w of solar, 2000w inverter would be fine and probably 8 to 10kwh of battery would be a safe bet if you are somewhat shaded.

    • @dominickthornburghakaTRG
      @dominickthornburghakaTRG Před rokem +1

      @@SmitHVAC. It would need to be a 24v set up correct, or could I use 48v?
      Also thanks for the quick reply.

    • @aznick102
      @aznick102 Před 11 měsíci +1

      Total greenhorn here, but could you not just run solar to batteries and then use 2000w inverter to power 12k btu? Instead of two arrays; one to power 12k unit and another to feed batteries? Sure I'm missing something...

    • @SmitHVAC.
      @SmitHVAC.  Před 11 měsíci +1

      @aznick102 Yes you can, this is just a cheaper way to get started in solar air conditioning if you don't already have a large battery bank and inverter

  • @155stw
    @155stw Před 11 měsíci +1

    I have one 440w panel and connected it but it when I checked the EG AC app, PV input was 0. I checked my panel and the Isc and Voc of the oanel showed it was functioning.

    • @SmitHVAC.
      @SmitHVAC.  Před 11 měsíci

      It needs a minimum of 90v DC input, you need 2 or 3 more panels

    • @155stw
      @155stw Před 11 měsíci +1

      @@SmitHVAC. I had my suspicioun that my temp PV setup wasn’t meeting the minimum requirements, so thanks for confirming. I actually have 4x440w panels at 48 Voc each so on a Sunny and hot day this should work out fine.

    • @SmitHVAC.
      @SmitHVAC.  Před 11 měsíci

      @@155stw That should be perfect!

  • @robbehr8806
    @robbehr8806 Před rokem +2

    Great video! Do you have any idea if they are going to produce a unit that runs directly off 48 volts DC?

    • @SmitHVAC.
      @SmitHVAC.  Před rokem +3

      Thanks Rob!!! Deye makes one but EG4 has not adopted it at this time.

    • @BobBob-il2ku
      @BobBob-il2ku Před rokem

      I hope EG4 imports those versions

    • @BobBob-il2ku
      @BobBob-il2ku Před rokem +1

      For a purely off grid application I wonder what is better a 48vdc Unit or the hybrid unit you have hooked up like yours solar direct + battery inverter ?

    • @robbehr8806
      @robbehr8806 Před rokem +1

      @@BobBob-il2ku , Some people seem to be configuring these off-grid to either run directly from a dedicated solar array or using 120VAC from an inverter connected to a 48VDC battery, with the 48VDC system charged by an alternate panel array.

  • @armourofgod6310
    @armourofgod6310 Před 6 měsíci +1

    So how many watts of solar do you think you need for this baby to run in winter?

    • @SmitHVAC.
      @SmitHVAC.  Před 6 měsíci

      A lot! Winters around here are pretty dark and grey

  • @bryhan67
    @bryhan67 Před 11 měsíci +1

    Say I have 2000 watts in panels and the house is nice and cool. Is there a way to continue to use the solar to charger batteries or go to the inverter? I wonder iv the PV could be tied to controller and AC unit at the same time. Would be a shame to have all the solar there and cant use it when the house is cool. Or when you dont need cool or heat those panles are useless?

    • @SmitHVAC.
      @SmitHVAC.  Před 11 měsíci

      I'm sure there is a way to do it, you might have to get creative. This is only $400 worth of used panels so it's not really a big deal, panels are pretty cheap!

    • @bryhan67
      @bryhan67 Před 11 měsíci +1

      @@SmitHVAC. yes but the more panels you have the sooner you can start in the morning and run later. Also on cloudy days . I have about 100 panels and I’m off grid . On cloudy hot days I use all that solar . I will call eg4. Down side is can’t put in 600v like the latest controllers. Nice video thanks for posting . 100% off grid using batteries at night it’s nice to see your numbers. Daytime I got tons of power at night gets tricky

  • @aroundtheshop
    @aroundtheshop Před rokem +1

    Can you program it to only run when there is enough PV input? and shut down when it loses sun?

    • @SmitHVAC.
      @SmitHVAC.  Před rokem +1

      If you set a daily start timer and leave the Ac input disconnected it will do that automatically

    • @aroundtheshop
      @aroundtheshop Před rokem

      @@SmitHVAC. Great info! Thanks much!

  • @russellkamp8923
    @russellkamp8923 Před 11 měsíci +1

    How to determine what size array I would need for the 12k btu or the 24k btu? I'm in north Texas. Full sun.

    • @SmitHVAC.
      @SmitHVAC.  Před 11 měsíci

      What are you trying to cool? A house? A garage? A bedroom? You'd need to figure out your sq footage and your insulation values of the space.

    • @russellkamp8923
      @russellkamp8923 Před 11 měsíci +1

      @@SmitHVAC. a well insulated 1300 square foot home. I have a Carrier central heat pump. I would like to use only at night. I'm trying to cut electricity bills and be independent during rolling black outs.

    • @SmitHVAC.
      @SmitHVAC.  Před 11 měsíci +1

      You could go with the 12k if you want to supplement the main Ac. It uses half the solar panels that the 24k needs. 24k would be capable of cooling the while house but requires more real estate for panels

    • @russellkamp8923
      @russellkamp8923 Před 11 měsíci +1

      @@SmitHVAC. thank you!

  • @kenputer56
    @kenputer56 Před rokem +1

    Do you need internet or will the app work off your phone internet ?

    • @SmitHVAC.
      @SmitHVAC.  Před rokem

      The unit itself needs to be connected to WiFi. You could hotspot if you had a lot of data, but it needs internet of some sort if you want to use the app. It also has a remote you can use instead.

  • @hanklinch2833
    @hanklinch2833 Před 11 měsíci +1

    How many AH does it use at night the lowest I can get it to go is 230 watts

    • @SmitHVAC.
      @SmitHVAC.  Před 11 měsíci

      I haven't been using much at night, it's been cooling off here into the low 50s over night lately

  • @MrVlandus
    @MrVlandus Před 6 měsíci +1

    So you turn it on and off with no issues. I want to run a system for my shed and can get a straight answer from anyone.

    • @SmitHVAC.
      @SmitHVAC.  Před 6 měsíci

      Yes, you can turn it on or off. If the sun gets too low it will shut off automatically

  • @lannyhargrove
    @lannyhargrove Před 9 měsíci +1

    How do I switch my display to fahrenheit??

  • @mosbysmen
    @mosbysmen Před 10 měsíci +1

    do you need a cell phone signal to use the app with your phone.

  • @douglassamuel9731
    @douglassamuel9731 Před 6 měsíci

    What uint is that. 6k,12k,24k that info would of been very helpfull.

  • @quartamile
    @quartamile Před 2 měsíci

    Is this the one that needs an entirely dedicated solar array that cannot also charge batteries?

    • @SmitHVAC.
      @SmitHVAC.  Před 2 měsíci

      It can be converted to 48vdc or ran directly off an inverter. Solar direct is the easiest and cheapest. With how cheap solar panels are, what's wrong with a dedicated array?

    • @quartamile
      @quartamile Před 2 měsíci

      @@SmitHVAC. Motorhomes don't have room for a separate array.

  • @justinmitchuson8992
    @justinmitchuson8992 Před 11 měsíci +1

    How many watts will it use while heating ?

    • @SmitHVAC.
      @SmitHVAC.  Před 11 měsíci +1

      Around 1300w on a high demand

  • @378Jona
    @378Jona Před 7 měsíci +1

    Hi i didn't know u can hook up different brand lithium batteries!!

    • @SmitHVAC.
      @SmitHVAC.  Před 7 měsíci

      Most manufacturers recommend not doing this.. But it hasn't been an issue yet

    • @378Jona
      @378Jona Před 7 měsíci

      @@SmitHVAC. ohh ok thanks. Good to know its possible tho. I have 2 12 volt redodo to 24volt bank but i dont have a shunt as yet , wanted to know how low in voltage i can run them down!??

    • @SmitHVAC.
      @SmitHVAC.  Před 7 měsíci

      @@378Jona the BMS cuts them off at 10.8v or 21.6v, depends how much load your pulling if your looking to shut them down just based on voltage

    • @378Jona
      @378Jona Před 7 měsíci

      @@SmitHVAC. thanks very much.

  • @timcat1004
    @timcat1004 Před rokem +1

    I bought a Chinese copy kat of one of these. I have it installed only to find out it's not pre-charged. The guy is coming in a day or two to charge it. Mine came with 1,330 watts of panels.

    • @SmitHVAC.
      @SmitHVAC.  Před rokem

      Hopefully it works well for you, what brand is it?

    • @mizaelnoriega9301
      @mizaelnoriega9301 Před rokem

      Post link please, not enough information on that on the internet.

    • @timcat1004
      @timcat1004 Před rokem +1

      @@SmitHVAC. Recreate brand. Very cheaply made copy kat. I will be doing a YT video on it. 2300 CAD with the 4 times 330 watt panels. Really suspicious that the condenser valves were wide open. The evap was charged with nitrogen.

    • @SmitHVAC.
      @SmitHVAC.  Před rokem

      Interesting. The specs are decent but I don't see a min/max input voltage or a refrigerant volume. Hopefully its printed on the rating plate!

  • @djcory2727
    @djcory2727 Před měsícem

    is this the 24k btu unit?

  • @TravisReeder
    @TravisReeder Před 10 měsíci +1

    Can you turn off the temperature LED on the inside unit?

    • @SmitHVAC.
      @SmitHVAC.  Před 10 měsíci +1

      Yes you can turn off the display

    • @TravisReeder
      @TravisReeder Před 10 měsíci +1

      Great, thanks@@SmitHVAC. Still like this system after a month?

    • @SmitHVAC.
      @SmitHVAC.  Před 10 měsíci +1

      I'm coming up on 8 months actually, I have a bunch of other videos from when I installed it in February! Yes I love it, I just installed 2 more of the new version at the cottage. Video will be coming soon! Thanks for watching

    • @TravisReeder
      @TravisReeder Před 10 měsíci +1

      @@SmitHVAC. What's the new version? We're looking at the 28.5 seer rated one, it's not hybrid, but that efficiency rating sounds pretty great.

    • @SmitHVAC.
      @SmitHVAC.  Před 10 měsíci

      @@TravisReeder the new version has the DIY precharged linesets like a Mr Cool

  • @kennethoh6928
    @kennethoh6928 Před 8 měsíci +1

    What is the ideal solar panels for 12k hybrid?

    • @SmitHVAC.
      @SmitHVAC.  Před 8 měsíci

      The ideal brand or the wattage? I have most 1200w of Canadian solar panels, will be upgrading to 1600 soon

    • @kennethoh6928
      @kennethoh6928 Před 8 měsíci

      Thank you for replying.
      I chose 305 watt Hyundai panels mainly for low price but little confused on how to stay within eg4 requirement.
      Does amperage of panels stay the same if I have 4 or 6 together to meet voltage and wattage requirements?

    • @SmitHVAC.
      @SmitHVAC.  Před 8 měsíci

      If you wire them in series you add the voltage, amperage stays the same. If you wire in parallel you add the amperage of the 2 strings.

    • @kennethoh6928
      @kennethoh6928 Před 8 měsíci +1

      Thank you. So just wire them in series.
      Do you think more solar is better?
      I was wondering if having little more than 1100w of panels would help on cloudy days. May be 5 or 6 panels for total of 1500 watt or 1800 watt.
      I had to buy 10 panels for them to ship so I have extras.

    • @kennethoh6928
      @kennethoh6928 Před 8 měsíci

      I’m planning to run mini split on panels without battery bank and use AC after dark.

  • @user-su5ft8lc9q
    @user-su5ft8lc9q Před 9 měsíci +1

    I was thinking you live out in the woods somewhere, like really just you ,WIFEY and a couple of curtin climbers and of course a couple of dog's. But i see I'm wrong.

    • @SmitHVAC.
      @SmitHVAC.  Před 9 měsíci

      Yup I'm right on the edge of the city. Just a wannabe offgrider!

  • @hayhow11
    @hayhow11 Před 7 měsíci +1

    Is that running with only three panels ?

    • @SmitHVAC.
      @SmitHVAC.  Před 7 měsíci

      No it's got 6 panels hooked to it

    • @hayhow11
      @hayhow11 Před 7 měsíci +1

      @@SmitHVAC. oh ok 👍🏻 what wattage are the panels?

    • @SmitHVAC.
      @SmitHVAC.  Před 7 měsíci

      @@hayhow11 they're 225w each. I have some new 400w panels I want to upgrade to I just haven't gotten the chance to install them yet

  • @kameljoe21
    @kameljoe21 Před rokem +1

    Lets keep in mind this is with the most basic solar levels. I think if I recall there is 800 watts in panels total.
    These systems can accept up to 3kwh of solar. At those numbers one might expect to see a massive amount more power over a longer period.

    • @SmitHVAC.
      @SmitHVAC.  Před rokem

      I have 1100 watts right now but I will be upgrading to 1600w before winter

  • @hectorz7860
    @hectorz7860 Před rokem +1

    Hello SmitHVAC, I am having issues with my 12000btu set up. When powering on the unit, the app will show a ramp up to about 550 watts of solar then come back down to about 300 watts. It will stay about that level but the unit will not put out any cold air. Lights, fans, outside fan run ok, but no cold air. My solar set up is 12-100 watt panels and am not connected to house grid power. Any suggestions or ideas would sure be appreciated. And thank you for your videos, they are very helpful.

    • @SmitHVAC.
      @SmitHVAC.  Před rokem

      Sorry to hear you are having issues! Is it newly installed or has it been working for a while now? What voltage are your solar panels individually and what is your total VOC?

    • @hectorz7860
      @hectorz7860 Před rokem +1

      @@SmitHVAC. This is a new DIY install. Solar panels are the standard 100 watt 12v type, with about 20v VOC. I have 10 connected in series and get a reading of about 220 volts. Full sunny day here in SoCal. And thank you for the quick response.

    • @SmitHVAC.
      @SmitHVAC.  Před rokem

      Are you able to tell if the compressor is running? It should be a quiet hum just below where you connected the AC and DC inputs

    • @hectorz7860
      @hectorz7860 Před rokem +1

      @@SmitHVAC. When I am checking the outside unit it is hard to tell if compressor is on because of the fan noise. Also the copper lines are not cold at all.

    • @SmitHVAC.
      @SmitHVAC.  Před rokem

      Interesting.. Did it sound like the refrigerant was released when you opened the valves?

  • @aroundtheshop
    @aroundtheshop Před rokem +1

    Which model is that? 12k Btu or 24k?

    • @SmitHVAC.
      @SmitHVAC.  Před rokem +1

      12k, I thought I had said this in the video but maybe not. Thanks!

    • @aroundtheshop
      @aroundtheshop Před rokem +2

      @@SmitHVAC. I might have missed that! I'm considering this setup for my Detached garage, but would probably need the 24k, I can only assume I'd need double or more the wattage at a minimum to have it run off grid.... Plan would be to put about 2k Watts of panels dedicated to it. Not sure on doing your "off grid battery" method yet. But possible down the road.

    • @SmitHVAC.
      @SmitHVAC.  Před rokem +4

      Yes I would shoot for around 2400w of solar. I have another backup method coming next video, stay tuned!

    • @kameljoe21
      @kameljoe21 Před rokem

      @@aroundtheshop Read the spec sheets about the max solar and max voltage and for a garage that you want to cool and plan on not giving it any grid power then running it slighty colder in there will help that cool or heat last a bit longer.

  • @miamiSincar
    @miamiSincar Před rokem +1

    wowwwww this is the most worth it ac ever

  • @user-zm4yg9xv8q
    @user-zm4yg9xv8q Před 7 měsíci

    There has been little to NO power savings/efficiency gains for 99.5 percent of all window units or small ac systems since the 1940's
    How can that be?
    They say theres 25 percent savings, but no, btu per watt is just about the same, or 1-200 watts less when running the full load of a say 15000btu window or mini split unit (which you can state, they work exactly the same. Efficeincy differences are ONLY from heat radiated inside of the physical metal parts and seals and insulation from the outside of the window unit)
    What window units of decent cooling capacity draw A reasonable 700-800 watts??? These compressors get hot as hell, they should not be exposed to heat because the copper windings will increase resistance, lower efficency, then get hot again and lower efficeincy again because of getting hot.
    There are hot gasses in the compressor, yes, from the heat cycle of the refrigerant. But the motor should be ambient. Not 150c.
    The fans too on the units are pigs, the window units expecially. Mini splits might have good to very good efficeincy, if they are dc fans but then they need some stupid, gonna burn out in 10 yr controller) I know these controllers are cheap and built to break. The engineering departments add complexity unessesary and then they break because one crappy part. And then theyre obsolete and non repairable because its an exclusive part or the part is not accessible to, ort the boards straight up fail and take out all the rest of the parts inline so , basically i can prove that they are junk AND I will DEFUND.
    THe fans should not get hot either, low efficeincy run of the mill units have crappy syncrohnous ac motors with the capacitors that always fail, why do they heat up, and heat up again too from being hot. Copper is only efficeinty in a motor IF IT SAYS COOL!!!
    THe things use 1200 watts 15k units will mostly all at best take 1200 watts.
    The things could be using 50 watts for the fan and 700 watts for the compressor.
    THis means, cop of 5 or 6 or more, Theoretically its like ten, BUT why are they barely scarping by with 3?>??
    It should be called energy efficient only if the motors arent running BOILING HOT 100c 150c they are terrible. They are the worst. 1940s, they had the same shit. GOD DAMN!!!1

  • @stiffmeister0hYeah
    @stiffmeister0hYeah Před 10 měsíci

    My Carrier SEER 19 18k BTU minimum I've ever seen is 1500 watts. Max has been close to 3000. I assume it's because the systems were not properly evacuated and refrigerant not weighed. The MX HVAC technicians in Cabo San Lucas are too damn lazy or stupid to do the work correctly.

  • @ooigfgnnkhjjnc
    @ooigfgnnkhjjnc Před 12 dny

    Canook

  • @enricoderojassarson5596
    @enricoderojassarson5596 Před 3 měsíci

    interesting but doesnt seem to be economically viable if you are on line power. Over $1,400 in batteries, plus panels, plus controller, plus wires and breakers

  • @newemail4917
    @newemail4917 Před 11 měsíci +2

    Company smoking crack with their pricing