  • In this video I do a 7 month review on the EG4 mini split 9k BTU mini split. This EG4 mini split is rated at 29.5 Seer2. This EG4 mini split is an impressive unit. I highly recommend it.
    To purchase this mini split using my affiliate link click here:
    tinyurl.com/2w...
    Use the discount code UNPLUGGEDTEXAN50 at checkout to save $50
    To check out my solar ebook I wrote go to:
    solar-ebook.com
    Below is a list of affiliate links to the equipment I used for the installation of the mini split:
    Wall mounting Bracket
    amzn.to/3U4c31m
    Disconnect - this is a 240v disconnect, since this mini split is only 120v I just connected the neutral line to the other leg of this disconnect (an electrician is highly recommended for this part)
    amzn.to/43Lh6Ht
    Wire whip - this is the wire you'll need to take power from the disconnect into the wire compartment on the mini split condenser. Keep in mind that there is no white (neutral) wire in this whip. You'll need to use the red wire as you're neutral since the mini split is only 120v.
    amzn.to/3VKOpZ3
    To download a free copy of my off grid solar system design pdf click here. This is a wiring schematic of my entire system with all equipment and links to components I used for the installation:
    Solarpdfdownlo...
    FTC Disclosure Statement and Disclaimers: Some links on this youtube (or other) channel may be affiliate links. We may get paid if you buy something or take an action after clicking one of these. My videos are for educational purposes only. Information is subject to change/update at any time. Electricity is DANGEROUS and can kill you! An electrician is recommended when working with both AC and DC electricity. This CZcams (or other) channel is a participant in the Amazon Services LLC Associates Program, An affiliate advertising program designed to provide a means for sites to earn advertising fees by advertising and linking to Amazon.com

Komentáře • 41

  • @robertvantichelt6448
    @robertvantichelt6448 Před měsícem +3

    I installed one of those 9k BTU 38 SEER mini splits at my girlfriend's house. 1700 sq ft. Heats the entire house in the winter. Cools the entire family room kitchen/dining area to a comfortable 78 this summer at 112 degrees outside. Back bedrooms reach above 83 degrees. I'm in 9b climate. Have 4000 watts worth of off grid solar with 3 eg4 lifepower batteries. 15 Kwh. Running the 38 SEER. We added an additional 9k 21 SEER unit in a back bedroom. And a 6000 BTU window unit that pulls 600 watts. All off grid summer and winter.

  • @mrrustygray
    @mrrustygray Před 5 měsíci +6

    Moved to 2 Prime Mini Splits and it cut my power bill by 100/mo. I have a large house and 2 full hvac systems. These will run you out of the room, chilled, and are so quiet. More efficient than a window unit.

    • @tamikaskinner2264
      @tamikaskinner2264 Před měsícem

      Nice. My home is old with uninsulated walls. The air handler unit and ductwork is in my unconditioned attic. I'm paying over $237 to keep my home at 82 degrees with fans running. Not happy. I'm excited to have my 9k btu minisplit installed next week. It going to cover my living and family room. It's embarrassing to have company over and it's 82 degrees inside

  • @ronjones5651
    @ronjones5651 Před 6 dny +1

    I have two of the 1 ton units that use direct PV in or regular 120 volt. They both work flawlessly!

  • @sspyder181
    @sspyder181 Před 5 měsíci +5

    Ive been running v1 (not pre filled lines) of this unit for over a yr now and its freaking awesome. Saved me 700kwh in solar last yr. Makes great heat at 15f. Im in Pa

  • @HotGritz910
    @HotGritz910 Před 3 měsíci +2

    I bought the 12k unit for my shuttle bus rv build. I plan to run it with a bluetti ac200L power station, which has 2048 wh. I also have 1100 watts of solar on my roof. Going by your review, this eg4 will work really well for me.

  • @paul.phillips
    @paul.phillips Před 5 měsíci +2

    I have one of these still in the box in my garage, going to install it in a nice new wood framed 10'x12' shed. I figure it should keep an insulated 120sf cool pretty well.

    • @unpluggedtexan
      @unpluggedtexan  Před 5 měsíci +1

      Yeah it will heat and cool that in no time at all.

  • @sarentopi1502
    @sarentopi1502 Před 2 měsíci +1

    At 950 watts your unit is drawing 7.917 amps, which exceeds by 2 the rated current of 5.97 amps. You state you wired the unit into a 15amp breaker, whereas the manual calls for a 20amp breaker (minimum circuit ampacity listed: 19.05 A). What wire size is on the circuit? Maybe it is running an excessive length inducing a voltage drop that causes the unit to draw more current.

  • @MitchOfCanada
    @MitchOfCanada Před 5 měsíci

    Jack of all trades master of none, though oftentimes better than master of one.

  • @majorhavoc9693
    @majorhavoc9693 Před 4 měsíci

    You should strap the extra line horizontal under the condenser outside.

    • @fauxque5057
      @fauxque5057 Před 3 měsíci

      Actually people should learn how to cut copper tube and flare the end. Then you don't have excess lineset coiled up outside

  • @samfish6938
    @samfish6938 Před 3 měsíci +1

    i read if you put it on ground the outside unit you will get less noise

    • @unpluggedtexan
      @unpluggedtexan  Před 3 měsíci

      I don’t hear it from the inside of my home at all. When I’m outside you can hear a hum. But that’s it. It’s very quiet.

  • @benkanobe7500
    @benkanobe7500 Před 5 měsíci +1

    Do the Right Angle mounts connected to your siding/studs come with the unit? If not, where/what do we specifically purchase them? Is there anything else we need other than electrical stuff?

    • @unpluggedtexan
      @unpluggedtexan  Před 5 měsíci +1

      No that doesn’t come with it. Give me until later today and I’ll add the items I used for the installation as links in the description of this video.

  • @roatanbound2023
    @roatanbound2023 Před měsícem +1

    What would you say it uses over 24h cooling on a hot day? Trying to decide if this will be a good fit for a tiny home I want to build on my property in the Caribbean!
    Thanks

    • @unpluggedtexan
      @unpluggedtexan  Před měsícem

      @@roatanbound2023 my estimate is on a 95 degree day, with decent insulation, and in a room that is the proper size for it, you’d be looking at 5-8 kwh’s over a 24 hr period keeping the room at 70 degrees. If keeping the room at 76 degrees I’ll bet it’s closer to 3-6 kwh’s over a 24 hr period.

  • @benkanobe7500
    @benkanobe7500 Před 5 měsíci +2

    So this is NOT the hybrid one that directly runs on solar panels, correct? I went to order your book and the site said "Not Secured". I don't risk my personal info on an unsecured site. Where else can I purchase your book safely?

    • @unpluggedtexan
      @unpluggedtexan  Před 5 měsíci +1

      It’s only the landing page that is not secure. Once you click on the purchase button it takes you to a secure checkout page.

    • @unpluggedtexan
      @unpluggedtexan  Před 5 měsíci +1

      And no it’s not the hybrid version. I already run 100% on solar so the extra cost for the hybrid doesn’t make sense to me.

  • @TheAnticorporatist
    @TheAnticorporatist Před 5 měsíci +2

    When you say that it runs an average of 250w overnight are you saying that it runs .25kwh/hour?

  • @FranciscoJavier-jn1kb
    @FranciscoJavier-jn1kb Před 4 měsíci +1

    DO you need a permit when installing this?

    • @unpluggedtexan
      @unpluggedtexan  Před 4 měsíci

      Nope. Though your HOA may have a heart attack if the lines and unit can be seen from the street.

  • @oilycare1820
    @oilycare1820 Před 5 měsíci +1

    can you provide the approx dimensions of the indoor unit?

    • @unpluggedtexan
      @unpluggedtexan  Před 5 měsíci

      Sure. It’s 42.5” x 13”. And it’s 9.3” deep.

    • @oilycare1820
      @oilycare1820 Před 5 měsíci +1

      @@unpluggedtexan Thanks! Just curious, are your measurements from the product spec sheet or actual measurements from product itself? Asking since the EG4 12K hybrid is only 37" long. Thought is was strange the 9K indoor unit it larger than the their 12k hybrid unit. So just wanted to verify.

    • @unpluggedtexan
      @unpluggedtexan  Před 5 měsíci

      @@oilycare1820 that was from the spec sheet. But I just measured my indoor unit and the spec sheet is accurate.

    • @oilycare1820
      @oilycare1820 Před 5 měsíci +1

      @@unpluggedtexan That's what I needed. Greatly appreciate you double checking with your installed unit. Keep the videos coming!

    • @unpluggedtexan
      @unpluggedtexan  Před 5 měsíci +1

      @@oilycare1820 make sure to use my discount code UNPLUGGEDTEXAN if you purchase it from Signature Solar to get $50 off. It also helps support my channel. Much appreciated.

  • @cat1racer
    @cat1racer Před 3 měsíci +1

    That code doesn't work.

    • @unpluggedtexan
      @unpluggedtexan  Před 3 měsíci +1

      Add 50 to the end of it.

    • @unpluggedtexan
      @unpluggedtexan  Před 3 měsíci +1

      They made us add numbers to it after they were already created.

  • @2hotscottpro
    @2hotscottpro Před 5 měsíci

    38-41.5 z seer is more gooder

    • @unpluggedtexan
      @unpluggedtexan  Před 5 měsíci +1

      Yeah but there isn’t one with that Seer rating that has the lines precharged with refrigerant. So you’ll have to pay a ton for install unless you do the vacuum pumping yourself.

    • @2hotscottpro
      @2hotscottpro Před 5 měsíci

      @@unpluggedtexan yah but isn’t in my vocabulary lol

    • @k.w.fisher3593
      @k.w.fisher3593 Před 2 měsíci

      SEER or SEER2? The 38 SEER I found by searching is rated at 27 SEER2. The EG4 9K unit is 29.5 SEER2. I would like to find a 38 SEER2 unit.

    • @2hotscottpro
      @2hotscottpro Před 2 měsíci

      @@k.w.fisher3593 Inovair 38 seer 9 kbtu? I don’t see the seer2 rating ? I think Midas has a 42 seer?