Replacing an R600 compressor - JDNel Refrigeration

Sdílet
Vložit
  • čas přidán 28. 08. 2024
  • Replacing an R600 compressor with R12 in a mini bar fridge

Komentáře • 207

  • @thingsbeensaidanddone.2378

    For a electronic engineer this is pritty violent. Those flames and explosions Hihi. But I learned a lot! He knows his job! Great video! Thanks!

    • @gaj1111
      @gaj1111 Před 2 lety

      At no time at university studying to be an electrical engineer, did you learn how to spell the word 'pretty'. Pls don't engineer anything electrical for me lol 🙄

    • @thingsbeensaidanddone.2378
      @thingsbeensaidanddone.2378 Před 2 lety +4

      @@gaj1111, in Belgium we speak Nederlands, French and German as official languages of the country. English is my fourth language. I am happy you understand me. Not expecting to write it perfectly. Sorry for that!

  • @Berni0707
    @Berni0707 Před 5 lety +15

    Replacing a damn R-600 compressor with pure R-12!? You're my HERO!

  • @AnhHaiCanTho
    @AnhHaiCanTho Před 4 lety +1

    I have a 4 doors Samsung refrigerator, and it’s not cold on the fridge side. I open the evaporator cover, and I found out that the evaporator has ice on it. I have replaced 2 sensors and a fan, but it still has the same problem. I decided to call Sears, 2 techs came out to check. They told me that its a 600 refrigerant, its very flammable. I asked them to see if they can fix it, they said they don’t have the equipment. I told them that I can order the compressor at Sears DIY website. 1 tech said the equipment is back order. I then asked them can you convert it into 134A or R12, they told me no. I wish you are closer to my place. I love your video. Thanks sir!

    • @JDNelRefrigeration
      @JDNelRefrigeration  Před 4 lety +1

      By changing the refrigerant, you will not solve the problem of over icing on your evaporator coil.

    • @hsnwfl7766
      @hsnwfl7766 Před 4 lety

      Yes most refrigerators and freezers are R600a now, need more videos with R600a .

    • @djnemesis82pluss1877
      @djnemesis82pluss1877 Před 2 lety

      Most Samsung defrost problems are thermistors or control boards…

    • @tuvoca825
      @tuvoca825 Před 6 měsíci

      You also need an unopened filter-dryer. It needs to be removed, brazed in. Cooled. Vacuumed. Charged with (R600 was it?). The system is designed mathematically for a specific refigerant.... the length of the capillary tube and everything are by design. Flammable gas.

    • @tuvoca825
      @tuvoca825 Před 6 měsíci

      ​@@JDNelRefrigeration True.

  • @carstencroessmann
    @carstencroessmann Před 3 lety +7

    He deserves the medal "Balls of steel "

  • @edwardtsang3243
    @edwardtsang3243 Před 3 lety +6

    Great worker no winging very practical guy.

  • @seanashcroft9713
    @seanashcroft9713 Před 2 lety +3

    Always enjoy watching your videos! Mooi! Thanks for sharing!

  • @user-li4ik9qs8c
    @user-li4ik9qs8c Před rokem +1

    excellent work, Mr. Nel,
    I'm sure you've heard about the concept of restriction that causes by Capillary tube
    some HVAC engineers say: it's 300psi Max. for R600 and 240 PSI Max. for r12
    I think that was the reason for the overheating of the motor and the filter..
    Thank you

  • @primeminister807
    @primeminister807 Před 3 lety +3

    R12 is still my favourite gas to work with in refrigerators but its now banned in my country.

  • @moagiphotodiodes7611
    @moagiphotodiodes7611 Před 6 lety +3

    sir i like they way you go into details of what you are doing thanks

  • @jimdefilippis9630
    @jimdefilippis9630 Před 2 lety +1

    love your video's. I learn something every time I watch them. The condenser you added on, is it hooked into the original condenser . Also, does the r-12 and r-600 compressors have similar running amps. Thanks for the video

    • @JDNelRefrigeration
      @JDNelRefrigeration  Před 2 lety +1

      I link the 2 condensers together to make 1 large condenser. Any domestic fridge with a compressor less than 250 Watt, you wont notice a difference on running amperage

  • @alimohammedkhan1535
    @alimohammedkhan1535 Před 3 lety +2

    Good knowledge

  • @calebnugent5515
    @calebnugent5515 Před 5 měsíci +2

    You are supposed to blow the lines out with nitrogen multiple times before you attempt to add heat.

  • @KevinFrancis556
    @KevinFrancis556 Před rokem

    Just let the gas blow out. Lol. Good thing your in South Africa.

  • @uniquebhojpurimusic9136
    @uniquebhojpurimusic9136 Před 2 lety +2

    Amazing sir

  • @a.belladonna8316
    @a.belladonna8316 Před 6 měsíci

    i love this video because he don't care ozone layer😁

  • @billmea5593
    @billmea5593 Před 4 lety +15

    The best idea is to purge the entire system with nitrogen before you bring your torch in there and blow things up

    • @JDNelRefrigeration
      @JDNelRefrigeration  Před 4 lety +1

      Yes, Good idea

    • @kojsiusoaliu6772
      @kojsiusoaliu6772 Před 3 lety

      'And blow things up' hahahah

    • @gaj1111
      @gaj1111 Před 2 lety +1

      Nothing blew up. It was all controlled. You're the stiff that's blowing up. Welcome to how actually gets done

  • @syedbasheer8210
    @syedbasheer8210 Před 3 lety +2

    Great job..

    • @syedbasheer8210
      @syedbasheer8210 Před 3 lety

      Sir, need more videos from your side.every week😀😀👌

  • @billyflanagan9657
    @billyflanagan9657 Před 2 lety +1

    No nitrogen purge? What a mess.This guy is the biggest hack I have ever seen.🤣

  • @HDXFH
    @HDXFH Před 2 lety

    Gotta love hydrocarbon refrigerants

  • @johnnystamboel7745
    @johnnystamboel7745 Před rokem

    The title says r600 but i noticed r12. How come ? Or did you replace the r600 compressor and charged the new one with r12, Sir?

    • @JDNelRefrigeration
      @JDNelRefrigeration  Před rokem

      Yes. I removed the r600 compressor and replaced it with a 1234a compressor which I charged with r12.

  • @guuuuustaf
    @guuuuustaf Před 2 lety

    You seem to be very knowledgeable. I am also a hvac tech. I had very little experience on capillarytube systems. I normally work with larger systems and eevs and txvs. But i recently diagnosed a capillary tube system. I noticed ice on the capillarytube like 1 feet or more from the end. Can low refrigerant cause this? could not find leak. My conlusion was a restriction by dirt or moisture. I took out the refrigerant, flushed with nitrogen, pulled a good vaccum, and recharged. After the procedure the machine worked great again( no ice on the outside of capillary anymore. Am i wrong if Ì say the if the capillarytube has ice far back. there is a restriction by moisture or dirt. Or could low refrigerant cause ice on the outside of capillary aswell?.

    • @JDNelRefrigeration
      @JDNelRefrigeration  Před 2 lety +1

      On a capillary system that is warm and you are just starting off, you do get ice forming on the outside of the capillary for the first few minutes, but as soon as the fridge is cold that ice should disappear. A restriction in your dryer will cause the capillary to form ice as well as you rightfully diagnosed.

    • @guuuuustaf
      @guuuuustaf Před 2 lety

      @@JDNelRefrigeration thank you for the answer😊

  • @mrniceguy5731
    @mrniceguy5731 Před rokem +2

    use nitrogen at 100psi to purge please not r12

  • @ilosappliancevideos47
    @ilosappliancevideos47 Před 2 lety

    Watching from the US.
    You mean you converted R600A to R12? You're my HERO, I can't tell you how much I hate R600a units. However, the government here is phasing out R12 refrigerants, hard to find these days.

  • @liviuion9651
    @liviuion9651 Před rokem

    Sir, I need your opinii:Lately, when I repair a fridges with a hole in the coil(it is about R600a fridges), after a period from the repair, the compresors fail, too.
    Did You notice Something Like that in your practice?

    • @JDNelRefrigeration
      @JDNelRefrigeration  Před rokem

      Yes, I think when the fridge loses all its gas the compressor keeps on sucking air in through the puncture where the gas leak is, and builds up a tremendously high highside pressure, which damages the compressor.
      Especially on R600 systems where the compressor is designed to pump a very low pressure gas.

  • @DWAYNE2ism
    @DWAYNE2ism Před 7 lety +6

    hey good video. why is R-12 and not dry nitrogen.

    • @DWAYNE2ism
      @DWAYNE2ism Před 7 lety +2

      in the Caribbean they have ban all cfc and phasing out hcfc and already looking into phasing out hfc

    • @JDNelRefrigeration
      @JDNelRefrigeration  Před 7 lety +4

      I blew the system through with a little bit of R12 not Dry nitrogen purely because the pressure of dry nitrogen could rupture the internal evaporator. They rupture at about 150 psi.

    • @JDNelRefrigeration
      @JDNelRefrigeration  Před 7 lety +4

      They are also phasing out cfc and hfc in South Africa but I use it because I have some stockpiled.

    • @Tim_Small
      @Tim_Small Před 6 lety +3

      JDNelRefrigeration You're obviously a smart guy, so please try and find something less damaging for your descendants than R12 for purging! GWP of 2400 and also Ozone depleting. In a lot of the world you'd face stiff fines for doing that...

    • @juanclavijo853
      @juanclavijo853 Před 6 lety +3

      HE CHARGED THE UNIT WITH R-12 CAN'T DO THAT IN US!

  • @carloslandaverde6475
    @carloslandaverde6475 Před rokem

    I accidentally broke a 3/16 pipe from the compressor of my kegarator, the gas leaked out, Inleft it outside for about two weeks now. I am sure I can braze the pipe back into the compressor port (after removing the little piece that was left), my only concern is: do you think that all remaining r600a has been evacuated from the system? When full it has like 1.5 oz

    • @JDNelRefrigeration
      @JDNelRefrigeration  Před rokem +1

      Blow another type of gas through the system, That will flush all the R600 out. Yes, they do weld successfully I have done hundreds of them through the years. Clean all the paint off with a wire brush attached to your drill then use a silver solder with a high silver content and a very big flame.

    • @carloslandaverde6475
      @carloslandaverde6475 Před rokem

      @@JDNelRefrigeration thank you so much! If I am getting it right, even though the mini fridge has been outside with the broken and separated pipe for two weeks, there is still r600a in the system? That is why I need to blow it out with other type of gas

    • @JDNelRefrigeration
      @JDNelRefrigeration  Před rokem +1

      @@carloslandaverde6475 Yes. There could still be some traces of R600.

  • @radenkorastovic2524
    @radenkorastovic2524 Před 4 lety

    Sir i have a small domestic frezer size around 100L the compresor is dead it runs on R12 .I have a second hand good compresor but what refrigirant should i put in cause R12 is baned .I have R600a and R134 .On wich refrigerant schould i do the conversion .

  • @efrendominguez2335
    @efrendominguez2335 Před 3 lety

    A 2 door no frost unit leak out.. Charge with r600.... Can I just charge it with r134a? Do I need to change oil and capillary tube

    • @JDNelRefrigeration
      @JDNelRefrigeration  Před 3 lety +3

      You don't need to change the oil but r600 capillary is much smaller than r134a so if you can change it, yes, also 134a needs a bigger condenser. If you can, add extra condenser. The bigger the fridge, the bigger the difference. On very small bar fridges you can use the same condenser and capillary.

  • @alejandromariano8422
    @alejandromariano8422 Před 5 lety +1

    Si le pones R12 , en lugar de R600, el motor se rompe ??

    • @JDNelRefrigeration
      @JDNelRefrigeration  Před 3 lety

      On small compressors it does not make a difference, but on larger fridges it does.

  • @dodden1
    @dodden1 Před 3 měsíci

    making an ozone hole with the R!2

  • @bmw5002
    @bmw5002 Před 29 dny

    try a 3-in-1 hard start capacitor before you condemn the compressor...

  • @MichaelMantion
    @MichaelMantion Před 4 lety +2

    HOW much is that tank of r12?????? that's crazy.

  • @darrosmaintenance2748
    @darrosmaintenance2748 Před 4 lety

    dear sir can you explain me how replace r600a to r134a my compressor is good . can possibly without replace compressor and oil changed r134a

    • @JDNelRefrigeration
      @JDNelRefrigeration  Před 4 lety

      I do not change the oil between compressors, I use the same oil. I replace the old compressors when they do not function properly anymore.

  • @jasonwhitaker4836
    @jasonwhitaker4836 Před 2 lety

    Anywhere close to Harlan KY, that I can get mine R-600 charged?

  • @leonrudman6293
    @leonrudman6293 Před rokem

    Why do the freezer work but fridge not one compressor please assist

  • @johnking1079
    @johnking1079 Před 4 lety +1

    Using R12 as a drying gas?? Expensive, hazardous and not very green. Why not nitrogen instead? Also brazing with R12 in the system can generate phosgene gas.
    Just curious... how expensive is R12 there? Here that jug is worth like $600.

    • @JDNelRefrigeration
      @JDNelRefrigeration  Před 3 lety +2

      When R12 was phased out I bought a stockpile which I am still using I have enough for another 2 years. I bought that gas 18 years ago.

    • @johnking1079
      @johnking1079 Před 3 lety +1

      @@JDNelRefrigeration That's awesome... that stuff is probably worth more than the fridge your putting it in (In the US anyway... $600 to $700 US a jug....) Similar market in South Africa?

    • @JDNelRefrigeration
      @JDNelRefrigeration  Před 3 lety +1

      @@johnking1079 No Not similar at all. There is no market for it.

  • @christianfredericks9225
    @christianfredericks9225 Před 4 lety +1

    Mini fridge?

  • @fordeo53
    @fordeo53 Před 3 lety +1

    Wtf mate. R12??? Also no micron gauge?

  • @mrsowt4897
    @mrsowt4897 Před 6 lety +2

    Nice sirr

  • @nuhsriqathar2029
    @nuhsriqathar2029 Před 4 lety +1

    Legendary

  • @bijoytudu165
    @bijoytudu165 Před 7 lety +1

    sir what is the length of capillary and suction line of deep frize 350 Lt . show video of deep frize making

  • @moeketsielias9935
    @moeketsielias9935 Před 6 lety +8

    R12 gas is banned in my country due to its damage effect on the environment. It is totally unexceptable to flash and allow this gas into the atmosphere.

    • @alyssaxu1915
      @alyssaxu1915 Před 2 lety

      Yeah.it’s the gas that’s been phased out slowly

    • @ilosappliancevideos47
      @ilosappliancevideos47 Před 2 lety +1

      I agree. I was shocked to see the tank labeled R12 in bold. We can't even find them here for old units.

  • @isanderrodriguez755
    @isanderrodriguez755 Před rokem

    my friend you must know that every refrigerant must be recover , not vent out to the air

  • @efrendominguez2335
    @efrendominguez2335 Před 4 lety

    Good day.... If r600 compressor leak out... Can I charge with r134a? Should I change the oil?

  • @rafamirtech8920
    @rafamirtech8920 Před rokem

    Can you use Indonesian subtitles? So that I can understand it? Thank you.

    • @JDNelRefrigeration
      @JDNelRefrigeration  Před rokem

      I use English sub titles, perhaps you can copy and paste them into Google Translate.

  • @barkingbarky858
    @barkingbarky858 Před 5 lety +10

    Using R12 is forbidden. Have you ever heard of ozone depletion and montreal protocol? In general: changing the refigerant requires the adaption of capillar tube, condenser and evaporator. You should evacuate the system and use dry nitrogen before brazing. Also the pressure test and the check of tightness are missing. Sorry, but your work is bad.

    • @Berni0707
      @Berni0707 Před 4 lety +5

      It's all about bussiness, chlorine is everywhere; it evaporates from the salts of the oceans and volcanos. Ozone is regenerated when and electric stom arrives, electrolisis process happens and turns O2 (oxigen) to O3 (ozone) end of montreal bussiness and this flammable refrigerants.

    • @nickolaswoodswoods2472
      @nickolaswoodswoods2472 Před 4 lety +1

      Let alone the $10,000 reward for anyone who reports this to the EPA?

    • @HVinduction
      @HVinduction Před 23 dny

      @@Berni0707 Lol, that is NOT how it works, chloride is a whole different kind of substance than chlorine gas. In almost all countries R12 is banned since the 2000s, since it is the worst gas for the ozone layer, it was even used as a propellant in spray cans. These substances really destroyed the ozone layer much faster than lightning, and that is not electrolysis but the crazy high temperature of lightning bolts that creates free radicals to convert oxygen molecules to ozone.
      There are so much things wrong in this video, the capillary tube and dryer should be changed so there is no moisture and the pressures are correct for R12/R134a, the oil and compressor must be compatible with R12, flushing with R12 is extremely dumb, heating it creates phosgene, you should use nitrogen and then pull a vacuum to remove all the moisture and air in the system.

  • @devpatel4492
    @devpatel4492 Před 4 lety +1

    Good vark sar theks

  • @s.s.bimbra
    @s.s.bimbra Před 6 lety

    Vry 9ce videos sir.sir can you guide me what is the correct back pressure of r134a in fridge

    • @JDNelRefrigeration
      @JDNelRefrigeration  Před 6 lety

      On a warm fridge not more than 150psi. On a cold fridge 80psi.

    • @s.s.bimbra
      @s.s.bimbra Před 6 lety

      JDNelRefrigeration sir this is low side pressure

    • @s.s.bimbra
      @s.s.bimbra Před 6 lety

      Susan Nel thks sir for helpful information

    • @JDNelRefrigeration
      @JDNelRefrigeration  Před 6 lety +3

      On a warm fridge, not more that 10 psi on a cold fridge, never in vacuum.

    • @s.s.bimbra
      @s.s.bimbra Před 6 lety

      JDNelRefrigeration thnks sir for help

  • @bijoytudu165
    @bijoytudu165 Před 7 lety +3

    sir what is the length of capillary and suction line of deep frize 350 Lt . show video of deep frize maiming,

  • @myopicthunder
    @myopicthunder Před 3 lety +1

    R12 jeez where's the ammonia

  • @cazador51978
    @cazador51978 Před 4 lety +3

    Not safety procedures Sr! plus not sense to come back to R-12 because is old and out the market refrigerant.

  • @cesardadison3972
    @cesardadison3972 Před 2 lety

    Where is the common line running line starting line

    • @JDNelRefrigeration
      @JDNelRefrigeration  Před 2 lety

      Top connection is common. Bottom left is start, Bottom right is run.

  • @nuhsriqathar2029
    @nuhsriqathar2029 Před 4 lety

    Sir.. Can r600a change to r134a.. Is oil are same?

    • @JDNelRefrigeration
      @JDNelRefrigeration  Před 4 lety +2

      Yes on a small domestic fridge.

    • @caseycleveland6564
      @caseycleveland6564 Před 3 lety +1

      No, they do not use the same oil. R600 uses a mineral oil while R134a polyolester oil. Plus a machine compressor should never be changed from one type of refrigerant to another without also changing out the condenser too to the correct specs.

  • @sadiqahmed262
    @sadiqahmed262 Před 2 lety

    What's the back pressure for R600

    • @JDNelRefrigeration
      @JDNelRefrigeration  Před 2 lety

      The high side pressure on a warm fridge should not exceed 120psi, on a cold fridge it can drop as low as 45psi

  • @johnkuhn8665
    @johnkuhn8665 Před rokem

    Dropping R12 gas is illegal and punishable by law, with a sentence of 15 years. Please use nitrogen rather

  • @rknight5748
    @rknight5748 Před 2 lety +1

    Good

    • @rknight5748
      @rknight5748 Před 2 lety

      I am from India 🇮🇳
      Refrigerator AC.water Ro filters.

    • @rknight5748
      @rknight5748 Před 2 lety

      I am engineer

  • @firenbubble
    @firenbubble Před 3 lety +1

    flushing with R12 ? seriously ?

  • @jaylou1486
    @jaylou1486 Před 2 lety

    My goodness, R-600 systems are extremely flammable, that is the reason why you do not braze on any R-600 systems. You suppose to use lock rings technique to do all of the seal system joints! You will get someone killed by watching this video.

    • @JDNelRefrigeration
      @JDNelRefrigeration  Před 2 lety +1

      I do on average 150 R600 systems a month in my shop. No fire yet. R500 is more flammable than R600.

  • @stoli6632
    @stoli6632 Před 4 lety +3

    Venting off R12 , not a good idea, should be using OFN.

  • @kindervelt2005
    @kindervelt2005 Před 5 lety +4

    Those fridges are so cheap, why bother?

    • @ka-i
      @ka-i Před 3 lety +1

      Less waste I guess

  • @jasonwhitaker4836
    @jasonwhitaker4836 Před 2 lety

    I need you to fix my R-600 where are you located??

  • @sidndlovu442
    @sidndlovu442 Před 7 lety

    Deep freezzer repairing

  • @alexisaacs699
    @alexisaacs699 Před 2 lety

    What you did here was extremely dangerous.....R600 gas is highly flammable and why didn't you cut all the lines to ensure all the gas was drained from the system before you introduced your naked flame.....

  • @caseycleveland6564
    @caseycleveland6564 Před 3 lety

    HVAC HACK: CZcams edition.

  • @TrendingVidyous
    @TrendingVidyous Před 7 lety

    ok thank you!

  • @GBrides
    @GBrides Před 2 lety

    sir how i collection the size 600 comprser

    • @JDNelRefrigeration
      @JDNelRefrigeration  Před 2 lety

      R600 is the refrigerant 600 not the price

    • @GBrides
      @GBrides Před 2 lety

      @@JDNelRefrigeration dear how i know the size of compser. Do you have size of compser sheet

    • @JDNelRefrigeration
      @JDNelRefrigeration  Před 2 lety +1

      @@GBrides Yes I do have a list of specifications you can email me & i will send it to you
      jdnelrefrigeration@gmail.com

    • @GBrides
      @GBrides Před 2 lety

      @@JDNelRefrigeration ok

  • @auwalusanyi7318
    @auwalusanyi7318 Před 6 lety

    sir what is the number of gauge for r600a

    • @JDNelRefrigeration
      @JDNelRefrigeration  Před 6 lety +1

      I don't use a gauge to determine the charge but it is lower than 134a

  • @johnkuhn8665
    @johnkuhn8665 Před rokem

    Please look at SAQCC gas -

  • @thanapameesit2634
    @thanapameesit2634 Před 6 lety

    Hello. I come. from. thailand

  • @bronzechicken4437
    @bronzechicken4437 Před 4 lety +3

    In the US you can't even purchase R12 and flushing any non-exempt freon, including R12 is how you go to prison.

    • @alyssaxu1915
      @alyssaxu1915 Před 2 lety

      R134a is the international replacement of r 12🥹

    • @ilosappliancevideos47
      @ilosappliancevideos47 Před 2 lety

      ...and they are now replacing everything including R134a with hydrocarbon based refrigerants.

    • @alyssaxu1915
      @alyssaxu1915 Před 2 lety

      @@ilosappliancevideos47 The new generation of refrigerants is replaced by the number starting with 4. Like R410a, R404a, R407C.

  • @jonlester10
    @jonlester10 Před 4 lety

    An open flame with r600(basically propane)? Sooooo dangerous. And not a good idea to switch refrigerants. You also want to scale in the new refrigerant...

    • @toddt6730
      @toddt6730 Před 4 lety +2

      600 is iso butane, 290 is propane, not trying to pick, just being helpful

    • @Superrandomz768
      @Superrandomz768 Před 3 lety

      Do you also own a fridge repair shop Lester! I would much rather trust him then you and all the other modern pansies out there

  • @auwalusanyi7318
    @auwalusanyi7318 Před 6 lety

    OK thanks

  • @inoahmann7542
    @inoahmann7542 Před 4 lety +1

    You could have charged the fridge with propane for way cheaper than r12.

    • @JDNelRefrigeration
      @JDNelRefrigeration  Před 4 lety +5

      Before R12 was phased out, I bought hundreds of cylinders and stock piled it.

    • @inoahmann7542
      @inoahmann7542 Před 4 lety +4

      @@JDNelRefrigeration You could probably make some serious cash selling those on Ebay. Nice work on the fridge. Don't listen to the haters. You got it running and that's what matters. I have repaired a couple fridges like the one you fixed and I've recharged both with Coleman propane. There is something to be said for refrigeration practices but on a unit as cheap as a mini fridge the cheapest repair is the right repair.

    • @MichaelMantion
      @MichaelMantion Před 4 lety +3

      @@JDNelRefrigeration There is an underground market in the US for it. Which I don't know why because like he said you can just use propane. Some old cars still have original r12 compressors and people pay $200 to get them charged.

  • @JohnWhite-zl5yl
    @JohnWhite-zl5yl Před 4 lety +1

    Yeeee haaaa cowboy

  • @lincoln6140
    @lincoln6140 Před 4 lety

    Was I the only one expecting a much larger flame? Butane and fire? What the literal crap?

  • @lwangajohn3257
    @lwangajohn3257 Před 6 lety

    Why don't you vacuum through the gauge ?

    • @JDNelRefrigeration
      @JDNelRefrigeration  Před 6 lety +2

      Because the shorter the distance between the vacuum pump & the compressor, the better vacuum I get.

    • @lwangajohn3257
      @lwangajohn3257 Před 6 lety +1

      JDNelRefrigeration would it be of any danger if I used the gauges

    • @JDNelRefrigeration
      @JDNelRefrigeration  Před 6 lety

      No danger whatsoever

  • @geraldvaldez5935
    @geraldvaldez5935 Před 3 lety

    Minimum gas, thats a BOMB!

  • @marchellep7692
    @marchellep7692 Před 6 lety +4

    I like most of your videos but this was not very good. Dont convert the fridges to any other refrigerant. There is no need to. Vacuum your system before disconnecting any pipes. Weigh in your charge its much easier.

    • @JDNelRefrigeration
      @JDNelRefrigeration  Před 6 lety +4

      If we cut a piece of the capillary off to replace the pencil dryer, the volume of the system will be smaller than before and if we put a measured amount of gas in it will have an over charge.

    • @user-bl4yo6jc4q
      @user-bl4yo6jc4q Před 4 lety

      We need oil for Refregrent 600
      How get oil for R 600

    • @1989Chrisc
      @1989Chrisc Před 3 lety

      @@user-bl4yo6jc4q use olive oil

  • @kg4muc
    @kg4muc Před 2 lety +1

    He wouldn’t last long here purging a system with R12 instead of nitrogen. If it purged first after refrigerant removal he might avoid the fire balls 😂

  • @AMERICANPRIDE1100
    @AMERICANPRIDE1100 Před 2 lety

    Geez r12 is like 1000 $ a can how about some r11

  • @NotSoCrazyNinja
    @NotSoCrazyNinja Před 6 lety

    I don't have the nerves to do this kind of work.

    • @toddt6730
      @toddt6730 Před 4 lety +1

      He almost killed himself 6 times in one minute

    • @johnnyriser8519
      @johnnyriser8519 Před rokem

      @@toddt6730 Not so. He had things under perfect control, as he had already removed the R600 gas, and all that was left was residue. He's performed this procedure many times, and knew exactly what he was doing! Thanks for the video sir.

  • @Tonyinmemphis
    @Tonyinmemphis Před 3 lety +1

    Removing r600 compressor and replace with r12 LOL. Not pulling vacuum to remove the 600 very dumb. This unit is not going to last long. R600 cap tube not the same as r12-134a cap tube. R600 runs in a vacuum psi. If his insurance company see this video lord help him. Do not replace r600 with r134 compressor.

    • @JDNelRefrigeration
      @JDNelRefrigeration  Před 3 lety +2

      3 years later and the fridge is still running beautifully. On a small bar fridge like that the difference in capillary size between 600 & 12 is minute but on a larger fridge it makes a huge difference.

    • @anthonymartin2412
      @anthonymartin2412 Před 3 lety +2

      @@JDNelRefrigeration with the added cond. not up on the captube size. But I know if you never try thing you never know what will work. Like using 404a for r22, I change a r12 2door freezer with r22 @ 125 head it still running been over 7 yrs now.

    • @mauricelinton5867
      @mauricelinton5867 Před rokem

      @tonymartin i have pulled a vacuum and have had r600 trapped in a restricted area, and blow up in my face… some times vacuums don’t work. And he is burning the gas… oil industry does this all the time.

  • @umair9419
    @umair9419 Před 5 lety

    compressor 744 co2 gass replies gass other

  • @blackdotradio8740
    @blackdotradio8740 Před 3 lety +1

    THERE IS A LOT OF WRONG GOING ON HERE.

  • @kjm-ch7jc
    @kjm-ch7jc Před 2 lety

    Trying to tell this donut of the effects on the environment using Dichlorodifluoromethane is like talking to a brick wall.

  • @nickolaswoodswoods2472
    @nickolaswoodswoods2472 Před 4 lety +1

    Good thing you aren’t in America. That is $20,000 fine for the two types of refrigeration you just felt let out of the system. You are supposed to blow the system with nitrogen. Not R12 Freon. You have no idea what your doing.. I have years of certified training and certification.

    • @JDNelRefrigeration
      @JDNelRefrigeration  Před 4 lety +2

      What do you think happened to all the SO2 and Metal chloride before R12 was introduced?

    • @nickolaswoodswoods2472
      @nickolaswoodswoods2472 Před 4 lety +1

      JDNelRefrigeration it got released into the air and now the world is melting because of it... I’m not a “save the world” “global warming is going to kill us” nut job, but I know science. Refrigerants such as the one in the video destroy ozone. No way around it

    • @johnking1079
      @johnking1079 Před 4 lety

      Actually I they upped the fine to $44,539 per day per violation. And... There's a $10,000 reward for someone to turn you in.

    • @AAAA-oe4ii
      @AAAA-oe4ii Před 3 lety +2

      What about chlorine released when volcanoes erupt, r-12 and r-22 are the gold standard in refrigeration.

    • @johnking1079
      @johnking1079 Před 3 lety

      @@AAAA-oe4ii The difference is that volcanoes release water soluble chlorine compounds released by volcanoes (Mostly Hydrocloric Acid) vs CFC's such as R12, R22. For example, HCL has a water solubility of around 720g/L at 20C... R12 has a water solubility of 0.286 g/L @ 20C. i.e. chlorine from Volcanoes gets absorbed by water vapor and falls to the earth as acid rain. chlorine from R12 doesn't. so R12 has a much higher probability of reaching the ozone layer than volcanic compounds.

  • @HDXFH
    @HDXFH Před 2 lety

    Modern junk

  • @daniellonergan5669
    @daniellonergan5669 Před 3 lety +1

    I'm not sure what I've just watched 😂😂😂 someone's not evolved with the trade and modern standards and safe practices , literally a "how not to" video 😂😂

    • @Superrandomz768
      @Superrandomz768 Před 3 lety +1

      Bullshite! You modern pansy...he just shows you how it can be done!

  • @bijoytudu165
    @bijoytudu165 Před 7 lety

    sir what is the length of capillary and suction line of deep frize 350 Lt . show video of deep frize maiming,

  • @bijoytudu165
    @bijoytudu165 Před 7 lety

    sir what is the length of capillary and suction line of deep frize 350 Lt . show video of deep frize making

  • @bijoytudu165
    @bijoytudu165 Před 7 lety

    sir what is the length of capillary and suction line of deep frize 350 Lt . show video of deep frize maiming,

  • @bijoytudu165
    @bijoytudu165 Před 7 lety

    sir what is the length of capillary and suction line of deep frize 350 Lt . show video of deep frize maiming,