  • Here I show how I used roof jacks to shingle 3000 square feet of 8/12 pitch roof by myself. The pattern worked out well, so I wanted to share it.

Komentáře • 27

  • @miguelvalenzuela
    @miguelvalenzuela Před rokem

    Perfect, thanks Steve, I have to do this stuff in my roof! thanks for sharing!

    • @NashwaukSteve
      @NashwaukSteve  Před rokem

      Any time! Good luck on your project!

    • @NashwaukSteve
      @NashwaukSteve  Před 11 měsíci

      Good to hear from you Miguel! Thanks for supporting my side business;)

  • @Cozcacuauhtli
    @Cozcacuauhtli Před 2 měsíci +1

    THANKS

  • @christelting1359
    @christelting1359 Před rokem +4

    On such a steep roof I'd install some permanent anchor points for a safety lines.

    • @SusiesRepeat
      @SusiesRepeat Před rokem +1

      My exact thoughts, install then now saves time later.

    • @kevindowner766
      @kevindowner766 Před 11 měsíci +1

      Where's this steep roof you talk of?

    • @mikeandrews5834
      @mikeandrews5834 Před 7 měsíci

      That's not a steep roof mine is 12 12

  • @relax-ie3mp
    @relax-ie3mp Před 11 měsíci +1

    Are you leaving the nails in after? Would screws be better because it won't pop out over time? Thanks.

    • @NashwaukSteve
      @NashwaukSteve  Před 11 měsíci +3

      Hello- yeah I used 3” sinker nails and left them in. I’d be a little weary of screws as they can’t handle the same shear load as nails can. For example, I can take out a stripped 3” deck screw by pounding it back and forth a bit, breaking it. I can’t do the same with a 10d sinker. As for pop-out, there are 100’s of roofing nails in the roof, so I hope nothing pops! Thanks for the questionn

    • @GreatDataVideos
      @GreatDataVideos Před 27 dny

      Definitely don't use screws. They shear. The Essential Craftsman just did a video about that (July, 2024).

  • @israelgabriel1989
    @israelgabriel1989 Před 11 měsíci

    What do you do for putting on grip right? Or underlayment?

    • @NashwaukSteve
      @NashwaukSteve  Před 11 měsíci

      I used synthetic underlayment, and I attached it with cap staples. I wanted to give it good wind resistance while I was slowly getting it shingled. I bought a Stinger cap stapler for that job. Kind of spendy though…

  • @johndickerson6363
    @johndickerson6363 Před 26 dny

    I've been roofing for almost 50 years. First thing you should have read the instructions, should have at least 5" offset .You said you used 6" offset, looks like 3" at the top to me. Someone said you put your nails too close, that's because your joints are too close. You voided warranty. Actually, you vary with your joints. Those nails should be 1" from the end. That looks like a 5/12 pitch to me, easily walkable to me. I just roofed my house 7/12 and 9/12 pitch. I walked the 7/12 but used jacks on the 9/12. A little steep but I have seen people walk them. Would make me a little nervous if is 3 story. I hope you don't take this personal, you're a good guy for trying to help people. Maybe you should watch video and read instructions first and learn the safe way. This can be dangerous work. I have seen people fall more than once. Luckily nothing serious. There has been results of people dying from falling from roofs. I always say work smarter, not harder. But #1 is safety first.

    • @NashwaukSteve
      @NashwaukSteve  Před 7 dny

      Thanks for the comment. Some good points. It is most certainly 8/12 though.

  • @ASmith-lh7ex
    @ASmith-lh7ex Před rokem

    nice work !!! what angle are the roof jacks ??

    • @NashwaukSteve
      @NashwaukSteve  Před rokem

      I just checked. These ones were fixed angle intended for 12/12 pitch. I guess they weren’t ideal for my 8/12 roof, but it got the job done!

    • @peterbarlow8912
      @peterbarlow8912 Před 9 měsíci +1

      Those are the lowest pitch fixed roof brackets I’ve ever seen. No way could they be used on 12/12 pitch. The planks would be sloping away from the roof. Jacks for 12/12 would be approaching 90 degrees. Really don’t need staging below 5/12 unless it’s a second story. Then I’d want one across the bottom. Never let your staging plank ends project that far beyond the bracket unless it’s lapping onto another plank on brackets.

  • @jasoncurry2814
    @jasoncurry2814 Před rokem

    Whats the pitch

    • @NashwaukSteve
      @NashwaukSteve  Před rokem

      8/12 - I could carefully walk on the underlayment, but not the shingles. The fresh aggregate was too slippery.

  • @johnsheaffer1738
    @johnsheaffer1738 Před rokem +1

    Your roof is gonna leak your nails are too close to your seams

    • @NashwaukSteve
      @NashwaukSteve  Před rokem

      I see what you’re saying. Time will tell at this point.

    • @kevindowner766
      @kevindowner766 Před 11 měsíci

      It's an 8/12 I'd be alot more worried if it wasn't this steep.

    • @natto_4
      @natto_4 Před 10 měsíci

      ​@@kevindowner766we see roof jack sinker nails rusted in keyways all the time. We also see underdriven sinker nails puncturing the shingles. Roof jacks definitely make moving around the roof easier but definitely seen multiple roofs damaged because of them.

  • @Yorkie285
    @Yorkie285 Před 2 měsíci

    Who ever did that shingle job, looks like crap.