How to Properly Enable Solis Grid Tie Limiter Function

Sdílet
Vložit
  • čas přidán 5. 09. 2024
  • This video shows you how to prepare your Solis Grid Tie limiter functions enabled. What to do properly prior to activating your limiting functions on your Grid Tie.

Komentáře • 198

  • @anakngjurassik
    @anakngjurassik Před 3 lety +2

    Ayos to ka solar magandang info ito..stay safe

  • @benkanobe7500
    @benkanobe7500 Před 6 měsíci

    Thank you for attempting this CZcams. I had my computer lap top turned to Max Volume and I could barely hear you. I do not think that was a simple set up and you seemed confused as to what to press next. Also, what was all the "Waiting"? I am looking to replace my Sun blue box 1000Watt Grid Tie Inverters with limiters, but this demonstration did not convince me this is any better. Can you recommend another CZcams on this subject with Solis Inverter? Thank you, it sure looks like a nice inverter.

    • @MarkMinoza
      @MarkMinoza  Před 6 měsíci

      Thats "Waiting" to sync to the Grid for 10 minutes as a requirement by the local DU.

  • @allanbarge69
    @allanbarge69 Před 2 lety +1

    Thanks for the video

  • @CB27
    @CB27 Před rokem +3

    Thank you for making this video.
    I have a 4G 5kW Solis inverter. Recently it started showing a hint alarm "Grid over voltage". How do I adjust the setting to stop the alarm. The grid is 238V, so not over voltage (240V system).

    • @MarkMinoza
      @MarkMinoza  Před rokem +1

      you can change its Grid Standard to UL-240. Any voltages that goes beyond 235Vac, UL-240 is being used and stable.

  • @johnruben1444
    @johnruben1444 Před 10 měsíci

    Very informative video, thank you very much. I have done the same setup and also limited export to -00000w (negative) since I do not have net metering from electricity company. The issue is throughout the day my minimum load is around 250-300watts due to my home UPS/inverter but LimByEPM generates around 160watts and limits the rest, when I turon on geyser then it generates more and delivers 2000w to 2600watts for the geyser, but when i switch off the geyser, it is back to 160-180watts and not generating full required load, why is this happening and I have the same CT and my solis inverter is S6 3kw with 540w x 6 mono perc panels. Pls help if further setting is needed to maximize my load. Also should I change my CT sampling ratio ?

    • @MarkMinoza
      @MarkMinoza  Před 10 měsíci

      Don't change your CT ratio if it's working. Though I upgraded my 3kw Solis meter type. I only observe that if my PV voltage drops to 200v. Check your graphs for confirmation.

    • @johnruben1444
      @johnruben1444 Před 10 měsíci

      @@MarkMinoza my PV voltage doesn't drop, most of the time I see PV being above 220+ and inverter only controls the amp. My graphs are usually up and down. What if I change export to +100w ? But I am scared my electricity bill will shoot up as mine is not a bi-directional meter.

    • @MarkMinoza
      @MarkMinoza  Před 10 měsíci

      @@johnruben1444 you may consult your local support. your inverter might need a firmware upgrade.

  • @MrJeonard1985
    @MrJeonard1985 Před 2 měsíci

    can i series 2 unit s6 5kw gridtie? if yes how connect the ct

    • @MarkMinoza
      @MarkMinoza  Před 2 měsíci

      yes, CT can be placed on both Active Line wire. if more than 2 in parallel, you need EPM for that.

  • @raffy323232
    @raffy323232 Před 3 lety +1

    good and informative video.... just want to ask kung talagang matagal talaga yung "status"... napansin ko... from 9:06am.... nag start and mga around 12:30pm na nag start mag produce ng around 630 watts at nag start na mag configure ng settings

    • @MarkMinoza
      @MarkMinoza  Před 3 lety +1

      Ang explanation ko sir sa video is to have the grid tie first get its maximum generation. This is to validate that we have no issue sa output ng gti bago e limit. Kasi pag nag limit kaagad tayo din hindi natin nakuha ang peak generation, ang usual question ng mga user palaging, baba ng harvest ko. I hope I answer your inquiry right.

  • @rickyrusselburgusa8644
    @rickyrusselburgusa8644 Před 7 měsíci

    Hey Mark, great video. So if you had to do over again, would you still go with the salmon burgers?

  • @TubolMotoadventures
    @TubolMotoadventures Před rokem +1

    What do u mean by make sure the load is above 500w? You mean the limiter wont work if the load is below 500w? so 300 watts will be just all be coming from the grid because it is below 500?

    • @MarkMinoza
      @MarkMinoza  Před rokem +1

      You current load (watts) should be above 500w for the limiter to be activated. The CT will detect who big is your power during the CT Link test.

    • @charlonesantos9796
      @charlonesantos9796 Před 25 dny

      @@MarkMinozayou mean sir sa ct link test dpat over 500 watts ang load mo. Sa testing lng? After non khit below 500 kna gagana n ng maayos ang gridtie inverter?

    • @MarkMinoza
      @MarkMinoza  Před 25 dny

      @@charlonesantos9796 yes sir, one time setup lang po yan.

    • @charlonesantos9796
      @charlonesantos9796 Před 24 dny

      @@MarkMinoza ok po akal ko need always 500 ang load para gumana ang ct link nya

  • @seans5960
    @seans5960 Před rokem +1

    I have this inverter and a second 6kw hybrid 5G (with the meter) - but it’s exporting far greater than the backflow limit, it’s like the hybrid can’t “see” what the non hybrid 4g is exporting- any suggestions? The address on both inverters is 01, is that correct?
    Thank you 🙏

    • @MarkMinoza
      @MarkMinoza  Před rokem

      Are you trying to limit the production? If you do. Enable. The limiter on Hybrid, have the GTi lower rating do all the harvest.
      What meter are you using in your Hybrid?

    • @seans5960
      @seans5960 Před rokem

      No, I want to limit exporting -EPM. The meter is RS485, the model is Acrel ACR10R.
      If I set the backflow to zero, the hybrid stops exporting but the 4g inverter keeps exporting

    • @MarkMinoza
      @MarkMinoza  Před rokem

      @@seans5960 then enable limiter on the 4G GTi. Regardless if its a ct or meter.

  • @oshinaguilar
    @oshinaguilar Před 2 lety +2

    The sequence of Commissioning; 1. start the Inverter ON; 2. AC breaker ON; 3. DC Breaker On? Correct po?

    • @MarkMinoza
      @MarkMinoza  Před 2 lety +1

      1. Enable the Grid first
      2. Enable your PV side ON
      Regardless anong gamit nyo na safety device (disconnect switch or MCB) , importante may pang disconnect kayo ng supply (PV or Grid). Iba naman gamit fuses.

    • @oshinaguilar
      @oshinaguilar Před 2 lety

      @@MarkMinoza when will be the inverter turn ON? before or after GRID & PV turned on? salamat po.

    • @MarkMinoza
      @MarkMinoza  Před 2 lety +1

      @@oshinaguilar it will turn on Only when your PV has reach its MPPT startup voltage (check your data sheet) . Depende sa wattage nyo, 3kw - 8kw Solis has 120Vdc startup while lower ratings has 90v and 60v.

  • @markgensiquian5399
    @markgensiquian5399 Před 3 lety +1

    ty bossing

  • @ramkumarsharma4139
    @ramkumarsharma4139 Před 2 lety

    What means power in watts in lcd schreen.it is generating by panels or going to household out appliances?

    • @MarkMinoza
      @MarkMinoza  Před 2 lety

      It's generating power going to the grid, not household. Its your grid that powers your appliances in your house loads.

  • @SoLuna137
    @SoLuna137 Před rokem

    how does Meter in Load work? does it mean that the CT is placed in the Load side of facility?

    • @MarkMinoza
      @MarkMinoza  Před rokem

      Meter in Load connection depends on the type of meter you’re using, I’ve placed a reference link below. But the way it works, think of it like connecting a sub meter to other connection. The meter is placed between source and Load. DU setup is meter in Load. Accuracy is high also in terms of reading.
      czcams.com/video/XalI0hPni3o/video.html ,

  • @emydg.9872
    @emydg.9872 Před rokem

    sir what is the procedure when shutting down the inverter? Which breaker to turn off first?

    • @MarkMinoza
      @MarkMinoza  Před rokem

      If its running, do the following steps.
      1. Disconnect your Grid
      2. Disconnect your PV

  • @wolfgangcorrea7878
    @wolfgangcorrea7878 Před 9 měsíci

    Hi, When CT is 100:33mA .. sample ratio should be 3000:1 I guess. But i see a lot of people recommending 1500:1. Why is it?

    • @MarkMinoza
      @MarkMinoza  Před 9 měsíci

      That's the standard value using the specific CT provided by Solis. No idea why some.people would have more than 3000:1 ratio.

  • @andyronan1202
    @andyronan1202 Před 2 lety +1

    OMG you have just fried my brain,

  • @francisjunsay39
    @francisjunsay39 Před 2 lety +1

    boss baka may video ka paano magconfigure ng energy meter via rs485 zero export

    • @MarkMinoza
      @MarkMinoza  Před 2 lety

      Need nyo po API ng hardware to be able to do that. Solis supports modbus protocol running on rs485 using A B connection. External Energy meter is like the EPM. Please see my EPM unboxing vid, may pin config po doon.

  • @romelnungay7776
    @romelnungay7776 Před rokem

    Does LimByEPM status means that my export control is off or on?

  • @luisreyes2546
    @luisreyes2546 Před rokem

    What is your pv connections? I have 4pcs pv panels 250w @34.1Voc each, what connections do I do?

    • @MarkMinoza
      @MarkMinoza  Před rokem

      Have it all in series. What I have is 12 x 100w all in series. Vdc startup is at 60v. So your 4 pv is perfect.

    • @luisreyes2546
      @luisreyes2546 Před rokem

      @@MarkMinoza Done, sir all 4 in series. And it's generating power. Thank you

  • @kmb123999
    @kmb123999 Před rokem

    May I ask, what specification of Solar Panels for 1kw Solis GTI S6 model. Thank you

    • @MarkMinoza
      @MarkMinoza  Před rokem +1

      my setup is having a 100w x 12. GTi on the video is 4G Model, not yet S6.

    • @kmb123999
      @kmb123999 Před rokem +1

      Thanks sir Mark :D

  • @lopin-nh2oy
    @lopin-nh2oy Před měsícem

    SIR KASAMA BA CT LIMITER SA PACKAGE NG SOLIS INVERTER? OR NEED KO PA BUMILI SEPARATE

    • @MarkMinoza
      @MarkMinoza  Před měsícem

      @@lopin-nh2oy alam ko kasama, but ask bago bumili just to make sure.

  • @murattan3865
    @murattan3865 Před 2 lety

    CT connect ?

    • @MarkMinoza
      @MarkMinoza  Před 2 lety +1

      Connect your CT to your main line, before the Load.

  • @MrJ-s3j
    @MrJ-s3j Před 5 měsíci

    Every morning po ba need to set the limiter kapag ng power on na inverter?

    • @MarkMinoza
      @MarkMinoza  Před 5 měsíci

      once lang yan sir e set. then activated na.

    • @MrJ-s3j
      @MrJ-s3j Před 5 měsíci

      @@MarkMinoza how about load sir kahit bellow 500w example umalis ako maga at 200 watts lang maghapon nakaactivate pa din po limiter nun? Worry ako kc baka magexport sa DU. TNX PO

    • @MarkMinoza
      @MarkMinoza  Před 5 měsíci

      @@MrJ-s3j regardless, once ma set ang limiter, activated na po yan kahit gaano kaliit ang load.

  • @murattan3865
    @murattan3865 Před 2 lety +1

    Is a smart meter necessary? Is just ct enough?

    • @MarkMinoza
      @MarkMinoza  Před 2 lety +1

      Depending on the GTi type, this one is CT. Solis also has Meter type GTi, you need to ask it from your seller.

  • @MrJ-s3j
    @MrJ-s3j Před 5 dny

    sir ano adviseable na sampling ratio 3000:1 or 1500:1

    • @MarkMinoza
      @MarkMinoza  Před 5 dny

      @@MrJ-s3j its 3000:1 po yan. Dahil sa ratio ng CT na ginagamit.

    • @MrJ-s3j
      @MrJ-s3j Před 4 dny

      @@MarkMinoza Export_P. -0027w power 570w ibig po ba sabihin nyan 27w galing sa grid 570 frm solar? salamat

    • @MarkMinoza
      @MarkMinoza  Před 2 dny

      @@MrJ-s3j Export = Selling, nag babato ka ng power papuntang Grid. Importing is ginagamit mo ang power ng Grid.

  • @anuledsroma
    @anuledsroma Před rokem

    Hello Mark, gusto kong mag-ADD ng isa pang SOLIS inverter, i am using SOLIS-1P5K-4G at naka net-metering na, problem kulang na yung 5K sa akin. need more, can Solis be paralleled connection tho net metering?
    Salamat po. God bless po
    Paano po yung electrical wiring diagram?

    • @MarkMinoza
      @MarkMinoza  Před rokem

      Yes, no issue on parallel if its net metered. Buy the Meter type GTi S6 models. Just like your existing, just add it to a new branch circuit.

  • @ramkumarsharma4139
    @ramkumarsharma4139 Před 2 lety

    335 watt 15 panels sir

  • @ramkumarsharma4139
    @ramkumarsharma4139 Před 2 lety

    Sir good morning pl solve my problem.as in my house 3 phase Solis inverter and in one or 2 phases from 12 noon to 3.00 pm voltage comes from 170 to 195 Can we with yr kind help limit the minimum input voltage to reqd level to run the inverter without alarm and produce electricity.sir what is min voltage reqd to run inverter smoothly or we can set / modify the range as minimum under un- g- v01 or v02. Pl advise me or any other solution.pl

    • @MarkMinoza
      @MarkMinoza  Před 2 lety

      Hi Ram, User Define is country specific. Values might be different ours. If its low grid voltage, choose UL-208 grid standard.

    • @ramkumarsharma4139
      @ramkumarsharma4139 Před 2 lety

      @@MarkMinoza sir by this option problem will be solved because after 3 to 4 pm grid voltage reaches above 200 .so pl give yr mob no to chat and solve the problem.

    • @MarkMinoza
      @MarkMinoza  Před 2 lety

      @@ramkumarsharma4139 have you tried contacting your local support? You can choose the User Define Options, I'll. Be making that video on the coming days to address your concern.

    • @ramkumarsharma4139
      @ramkumarsharma4139 Před 2 lety

      @@MarkMinoza sir It is possible to make / modify limit coming from grid as such 170 to 195 during hot sunny time when solar produces optimistic valuable energy to max and it's use in real sense sir.Can I talk to yourself when Co man comes today most peobly and he will set the lower limit of grid voltage as required to run the 3 phase inverter smoothly sir.or we have to change single phase Solis inverter sir pl

    • @MarkMinoza
      @MarkMinoza  Před 2 lety

      @@ramkumarsharma4139 you can configure it. V1/V2 is youre threshold values.

  • @hawkray77
    @hawkray77 Před 6 měsíci

    sir new user ako ng solis s6 gr1p6k s, pwede po ba magparuro pano set-up ang limiter nito? salamat po

    • @MarkMinoza
      @MarkMinoza  Před 6 měsíci

      Sa Model S, wala pa akong guide, ill make one. kaka kuha ko palang ng unit.

  • @RandyNicolas-mu9wp
    @RandyNicolas-mu9wp Před rokem

    Sir, saan puede bumili ng current sensor para sa 6k s6 ct type. Thank you sor Mark.

  • @anethemia7857
    @anethemia7857 Před 2 lety

    Sir mark yung linya namin dito sa cebu province is line to line,saan po dapat elagay yung ct sensor sir?

  • @kamalhussain8517
    @kamalhussain8517 Před 3 lety

    How can I buy one of these

    • @MarkMinoza
      @MarkMinoza  Před 3 lety

      Depending where you are, Solis is available worldwide. You may reach them thru this site. www.solisinverters.com . If you live in PH, Lazada or Shopee online portal has one.

  • @ranelmaglangit
    @ranelmaglangit Před 3 lety

    sir mark panu po ba yung hybrid ko??6kw sya..tapos 1 to 2 kw lng na haharvest nya..wala pang battery...den naka limiter ako

    • @MarkMinoza
      @MarkMinoza  Před 3 lety

      Remove the limiter para malaman nyo sir ang max output. Install also the soliscloud app. Nakikita mo kasi lahat doon ang consumption nyo vs generation kung tama. Maganda ang graph ni Solis sa portal, puede kang mamimili ng data.

  • @ramkumarsharma4139
    @ramkumarsharma4139 Před 2 lety

    In my single phase inverter status shows LIM By Vg normally in midday 12 to 3 pm when grid voltage show 270+ and oneby one some time generating and limbyvg Is It harmful to inverter and vice versa how to rectify this problem sir.pl

    • @MarkMinoza
      @MarkMinoza  Před 2 lety

      What's the model of your Inverter and its max PV installed?

    • @ramkumarsharma4139
      @ramkumarsharma4139 Před 2 lety

      @@MarkMinoza Solis inverter single phase 1P 5 k 4 G and panels 15 for 5 KW sir

    • @MarkMinoza
      @MarkMinoza  Před 2 lety

      @@ramkumarsharma4139 can you provide the break down of your PV String, how many are in DC1 , DC2 and DC3 in series ?

    • @ramkumarsharma4139
      @ramkumarsharma4139 Před 2 lety

      @@MarkMinoza in DC1 seven panels and DC2 8 panels .normally in DC1 status shows approx 230 or 240 and in DC2 shows above 250 to 270 in mid day time sir

    • @MarkMinoza
      @MarkMinoza  Před 2 lety

      @@ramkumarsharma4139 your pv setup is correct, the alert on LimbyVg is has something to do with power generation. The inverter limits its power generation during that time. Check your Advance Information page for more details or your SolisCloud Portal.

  • @arielyu7103
    @arielyu7103 Před 11 měsíci

    Hello sir, paano po setup ng ng limiter pag dalawang Solis grid tie na nka parallel? Hindi ko kasi mkita sa manual. Salamat po

    • @MarkMinoza
      @MarkMinoza  Před 11 měsíci

      Connect both CT on live wire, or use external EPM to consolidate your graphs.

    • @arielyu7103
      @arielyu7103 Před 11 měsíci

      @MarkMinoza salamat sir.. kahit 6-10pcs na ct sensor pwede ilagay lahat sa live wire?

    • @MarkMinoza
      @MarkMinoza  Před 11 měsíci

      @@arielyu7103 parallel still stable at 2 GTi, more than that, you need EPM if you plan to limit it. But if you don't. EPM is optional. For more info on EPM, kindly see this video.
      czcams.com/users/liveyOFpafL-h4o?si=F-OjJ9nODGJygkuA

    • @arielyu7103
      @arielyu7103 Před 11 měsíci

      ​@@MarkMinozacopy. salamat sa pag share ng knowledge sir.

  • @anethemia7857
    @anethemia7857 Před 2 lety

    Sir good day po,alwys watchng from cebu prvince.sir mark kung mag install ng sOLis ano una dapat esettings sah parameters sir?.

    • @MarkMinoza
      @MarkMinoza  Před 2 lety +1

      kung similar hardware na Grid Tie inverter (Solis), this YT is your guide to enable the Inverter not to export.

    • @anethemia7857
      @anethemia7857 Před 2 lety

      @@MarkMinoza sir mark hindi bah masira ang solis inverter kung sakali ang load ng aking bahay ay aabot ng 5kw,tapos yung sOLis invrtr koh ay 3kw lng sir?

    • @MarkMinoza
      @MarkMinoza  Před 2 lety +1

      @@anethemia7857 Hindi po since its a Grid Tie Inverter, walang issue sa overload since regardless of load, sa Grid siya nag send ng power, not to your load.

    • @anethemia7857
      @anethemia7857 Před 2 lety +1

      @@MarkMinoza ok thank u sir.

  • @richardalegre9881
    @richardalegre9881 Před rokem

    Goodmorning sir, mag tatanong lang po ako about sa export control sir ng Solis, lalabas lang po ba yung status po na "LimByEPM" pag sobra napo yung ginegenarate po kesa sa load ng building po?

    • @MarkMinoza
      @MarkMinoza  Před rokem +1

      Yes sir, lalabas yan. pag nag hahabol at it will have Generating display. 1Kw output, pero ang load is 2Kw, Generating ang lcd nyo.

    • @richardalegre9881
      @richardalegre9881 Před rokem +1

      @@MarkMinoza Maraming salamat Sir!

  • @sofiakulittv4880
    @sofiakulittv4880 Před 2 lety

    Good day sir....ok lang ba pag LimByEPM yung nsa satatus nya?....tnx you po

    • @MarkMinoza
      @MarkMinoza  Před 2 lety

      Yes po, that means the limiter is enabled.

  • @kentoy5598
    @kentoy5598 Před 3 lety

    Good day, Bakit kaya sir yung solis 3kW inverter ko kapag e on na yung transformer type na welding machine sa grid sya kumukuha ng power?

    • @MarkMinoza
      @MarkMinoza  Před 3 lety

      Sa grid po lahat, since your gti is connected sa grid. Mag depende naman po yan sa generation ng gti nyo during usage ng welding nyo. Malakas ang welding.

    • @kentoy5598
      @kentoy5598 Před 3 lety

      @@MarkMinoza Kasi pag nka on na yung welding machine may 8 amps reading ang clamp meter sa grid na side then 300 watts sa inverter. Papalo ng 1kW mahigit genereated power sa inverter kapag mag wewelding na. Sa grid side nman aabot ng 10 Amps. Gusto ko sana pag nka standby yung welding machine sa inverter sya kukuha ng power mara masagad yung harvest.

    • @MarkMinoza
      @MarkMinoza  Před 3 lety

      @@kentoy5598 the Inverter cannot react automatically sa surge ng welding nyo po. Also, kung naka limiter kayo, talo pag may welding kayo. To get your current ng inverter nyo, but a clamp meter with inrush capability. Para makita nyo gaano kalaki ang lumalabas na current during welding.

  • @ejjuan9220
    @ejjuan9220 Před 3 lety

    Kahit po ba to connected sa grid, di sya mag oon hangga't walang power si panel?

    • @MarkMinoza
      @MarkMinoza  Před 3 lety

      Yes po, the gti will shutdown without PV

  • @maymay1382
    @maymay1382 Před 2 lety

    Sir paano gamitin ang user define kc laging nag highvoltage s amin kaya nagkulay orange si inverter gusto k sanang iadjust voltage range ng solis 3kw na gamit kp. Tnx po sana maituro niyo po.

    • @MarkMinoza
      @MarkMinoza  Před 2 lety

      User Define is based on your Grid provider. Sila ang mag bibigay sa inyo nyan. Ill come up with a guide on that also dahil marami ding nag tatanong. But if your grid is high, use the UL-240 settings.

    • @maymay1382
      @maymay1382 Před 2 lety +1

      @@MarkMinoza tnx po. Try ko po, aabot kc ng 242 - 246volts ang grid namin kaya lging alarm pag sa tanghali lng nman.

  • @muhammadhilmiyusra8932

    This solis 1kw or 3kw?

    • @MarkMinoza
      @MarkMinoza  Před 2 lety

      the procedure works on any Single Phase Solis units. Im using a 1Kw GTi on this video

    • @muhammadhilmiyusra8932
      @muhammadhilmiyusra8932 Před 2 lety +1

      can you make a video for the installation from beginning like how to install solar panel to inverter and grid from electric home. Thankyou sir because i wanna make solar grid tie in my home.

    • @MarkMinoza
      @MarkMinoza  Před 2 lety

      @@muhammadhilmiyusra8932 you might want to see this past video using micro GTi i did. Ill create one in the future. you can drop me an email and ill be happy to help you.
      czcams.com/video/dqj1wfxc-kY/video.html

  • @franklaurencecanoy617
    @franklaurencecanoy617 Před 3 lety

    Nice vid. hi sir may alam po bakayung model ng solis inverter 4kw, na may export limiter ?

    • @MarkMinoza
      @MarkMinoza  Před 3 lety +1

      1/3/5/6/8/10kw lahat po may limiter functions. Ask your seller to include one.

    • @franklaurencecanoy617
      @franklaurencecanoy617 Před 3 lety

      @@MarkMinoza thank you po, Pano po ba malaman na may export limiter siya sir? may ibang name ho ba cya na it means this inverter is has export limiter ? kasi sa data sheet d ko makita yung exact word na export limiter, pa help po

    • @MarkMinoza
      @MarkMinoza  Před 3 lety

      @@franklaurencecanoy617 check your serial #, on the 6th digit, it should be 1 or 2, 1= ct, 2=meter. Pag 0, hindi activated ang limiting functions. Bili ka ng external EPM para mag function ang limiter.
      SN# 123A45 1

  • @ryanvarona730
    @ryanvarona730 Před 2 lety

    sir, once mulang e set/enable yung limiter? or do you have to enable it everyday?

    • @MarkMinoza
      @MarkMinoza  Před 2 lety

      once lang sir, the system will automatically save it.

  • @boymakul8vlogs363
    @boymakul8vlogs363 Před 2 lety

    Ask lng po paano kung na install na lahat tapos ang power lang is 30w ang nasa display ano po gagawin

    • @MarkMinoza
      @MarkMinoza  Před 2 lety

      dont enable the limiter muna. Just like in my video, pina takbo ko muna para makita ko ang peak harvest then doon pa ako nag enable ng limiter. Now, ang pag lagay sa CT mag depende sa Grid type nyo. Pag L-L no issue, pag L-N, sa L nyo ikabit.

  • @bibsky222
    @bibsky222 Před 3 lety

    sir may paraan ba para ma zero limit ang grid. kc kahit mganda naman harvest ay may 70 to 80 watts pang consume sa grid.

    • @MarkMinoza
      @MarkMinoza  Před 3 lety +1

      Ang limiter nyo po nag aadjust lagi sa load nyo. Either mahuli o mauna. Hindi talaga ma 0 yan unless ang load nyo constant, hindi gumagalaw. Kung 100w, 100w lang talaga, pero hindi yan mangyayari dahil ang mga gamit natin pabago bago.

    • @bibsky222
      @bibsky222 Před 3 lety

      @@MarkMinoza k salamat sir. nkita ko kc solax 0 and 5 lng lagi yung makikita mong cobsumed load s metro. maliban lng kung mababa harvest. yung sakin solis 1 kilowatt pv ang max load ko lng ay 300 watts . pansin ko kahit tirik araw more or less 700 watts na ang harvest pero mataas pa din yung load s metro bka may mali ako sa settings.

    • @MarkMinoza
      @MarkMinoza  Před 3 lety

      @@bibsky222 nakikita ko sa 3kw ko na mag 0 using may external digital watt meter sa bahay. Ang 1kw ko pang test lang so hindi ko na test properly. Ill test again.

    • @KutsiTekin
      @KutsiTekin Před 2 lety

      İnverter devredeyken gücüne göre şebeke enerjisini sıfır tüketen cihaz bakıyorum tavsiyeniz varmı ?

    • @jasonking4697
      @jasonking4697 Před 4 měsíci

      Set mo lng backflow power from 0 to 100 watts ma zero yn lalo n pag malakas harvest vs load

  • @raymundzacarias834
    @raymundzacarias834 Před 3 lety

    bakit ung sakin naka set nmn na ung ct at correct nmn pero bakit pag nagbawas na aq ng load sa bahay eh nag exxport aq sa meralco, any tips? ung linya nmin d2 110v-0-110v khit sa kabilang linya same parin nag eexport parin aq.. baka pd nyo aq matulungan sa issue q salamat po

  • @reggieanuta675
    @reggieanuta675 Před 3 lety

    Sir..paano po ba ang tamang paglagay ng limiter..
    1.Dapat ba malapit sa main panel box ng bahay?
    2.Ano po ang position ng arrow..Papunta ba sa main panel box?

    • @MarkMinoza
      @MarkMinoza  Před 3 lety +1

      1. Hindi po kailangan since ang CT lang dapat malapit sa main breaker
      2. Nasa video po paano malaman kung tama ang ang link. Dapat e test mismo.

  • @anethemia7857
    @anethemia7857 Před 2 lety

    may 2kw bah nah solis sir?

  • @pierduos2099
    @pierduos2099 Před 2 lety

    Good day sir baka pwd po pahelp .. panuka namin makontak gusto lang po namen magpa assist. Sa solar set up namin?

    • @MarkMinoza
      @MarkMinoza  Před 2 lety

      You may ask for Solis Support from the FB Group here.
      facebook.com/groups/413473389645478/?ref=share_group_link

  • @anethemia7857
    @anethemia7857 Před 2 lety

    Kung magset up ng grid tie sir,kaelangan paba magpaalam sah DU Sir mark?

    • @MarkMinoza
      @MarkMinoza  Před 2 lety +1

      not necessarily since On Grid po, sa umaga lang libre. kung gusto mong putulin si DU, mag Hybrid Off Grid ka. though mahal dahil sa battery.

    • @anethemia7857
      @anethemia7857 Před 2 lety +1

      @@MarkMinoza ok po sir,maraming slmat sayo.

    • @anethemia7857
      @anethemia7857 Před 2 lety

      @@MarkMinoza yung CT sensor sir,kasya bah sya eclamp sah stranded wire nah ang sukat ay 25mm or 35mm sir?

    • @MarkMinoza
      @MarkMinoza  Před 2 lety

      @@anethemia7857 Kasya pa sa 25mm (4awg) sa 35mm mukhang hindi na mag kasya.

  • @ruelebio8179
    @ruelebio8179 Před rokem

    Puede ba yan i set na off grid lng?

    • @MarkMinoza
      @MarkMinoza  Před rokem

      Grid Tie Inverter po yan, hindi po yan tatakbo na walang grid. Need nyo po is off grid Inverter or hybrid off grid inverter para magamit nyo ang hardware kahit walang grid ang lugar nyo.

  • @shaagaelecp6musicmadhushan795

    sound is very low. 😪

  • @alaehcjsvlog
    @alaehcjsvlog Před 2 lety

    boss tanung lang po about sa ct pano po gagawin dun naka saksak naman po sya pero wala sya sa settings po walang mode select at ct sampling ratio wala po sa setting solis 3kw din po gamit ko

    • @MarkMinoza
      @MarkMinoza  Před 2 lety

      Napasok nyo po ba ang “Advanced Settings” ng unit nyo?

    • @alaehcjsvlog
      @alaehcjsvlog Před 2 lety

      @@MarkMinoza opo wala nga po dun

    • @alaehcjsvlog
      @alaehcjsvlog Před 2 lety

      @@MarkMinoza wala po sya sa advance settings

    • @alaehcjsvlog
      @alaehcjsvlog Před 2 lety

      @@MarkMinoza na reset and update kona din po sya wala parin po

    • @MarkMinoza
      @MarkMinoza  Před 2 lety

      @@alaehcjsvlog anong model ng unit nyo?

  • @marigoldkitchenette6103

    Magandang araw po sir 3k Solis inverter po ung gamit ko.bkit po kya pag binubuksan ko ung aircon nag aalarm ung inverter ko.salamat po

    • @MarkMinoza
      @MarkMinoza  Před 3 lety

      Paanong alarm? Baka puedeng ma share mo ang alarm code or description.

    • @marigoldkitchenette6103
      @marigoldkitchenette6103 Před 3 lety

      Ung monitor po nya sir naka kulay orange.tsk bkit po ung export ay sobrang laki ng nilalabas? salamat po sir sa pag bigay nyo ng pansin

    • @marigoldkitchenette6103
      @marigoldkitchenette6103 Před 3 lety

      @@MarkMinoza hnd po ako marunong mag insert photo sa youtube

    • @marigoldkitchenette6103
      @marigoldkitchenette6103 Před 3 lety

      @@MarkMinoza sir may contact No.po b kyo para kyo n lng irecomend ko sa kaibigan ko

    • @marigoldkitchenette6103
      @marigoldkitchenette6103 Před 3 lety

      Hnd po kya dahil pag malaki ang Load umiinit ung inverter kya nag aauto shot down?ok lng po kya sir lagyan ng cooling fan?

  • @aldeebigueja9609
    @aldeebigueja9609 Před rokem

    sir yun arrow ng limiter papalabas ba ng grid or papasok, sa video kc papalabas pero binago nyo. tnx

    • @MarkMinoza
      @MarkMinoza  Před rokem

      Yung CT link Test po ang susundin nyo kung saang arrow. Hindi nyo ma activate ang limiter kung hindi kayo mag CT link sa CT type Inverter. Sa meter no need, ill post a new video using meter.

    • @aldeebigueja9609
      @aldeebigueja9609 Před rokem

      @@MarkMinoza sir mark m ano ibig sabihin ng fail safe sa gti

    • @MarkMinoza
      @MarkMinoza  Před rokem

      @@aldeebigueja9609 you can enable Fail Safe or Not, hindi requirement sa atin yan. Ang trabaho ng failsafe is to check the connection ng CT at Inverter. Pag nawala or open ang ct mo, mag alarm.

    • @aldeebigueja9609
      @aldeebigueja9609 Před rokem

      ​@@MarkMinoza sir bakit kaya 11w lang na generate ng gti ko 4x240w pv ko tnx

    • @MarkMinoza
      @MarkMinoza  Před rokem

      @@aldeebigueja9609 anong Vmp ng pv nyo at rating ng Solis Inverter na Ginamit? Disable nyo muna ang limiter para ma check ang max output.

  • @marigoldkitchenette6103

    Sir ano po ibig sabihin ng limbyVar. Salamat po

    • @MarkMinoza
      @MarkMinoza  Před 3 lety

      Not familiar by it. You may escalate it to support.

  • @fireandrevivalinmyheart6365

    Hi po boss pano po mg install ng 30kw grid tie po na solis grid tied po diko po alam yung pag parallel nga solar panel po hehehe ng try lng mg design sir... hehehe

    • @MarkMinoza
      @MarkMinoza  Před 2 lety

      need nyo po EPM for that huge capacity. ang EPM may manual, nandoon ang design paano nyo e parallel ang connection.

    • @fireandrevivalinmyheart6365
      @fireandrevivalinmyheart6365 Před 2 lety +1

      @@MarkMinoza salamat po bossing try ko e search duon..thanks

    • @MarkMinoza
      @MarkMinoza  Před 2 lety

      @@fireandrevivalinmyheart6365 sali ka po sa PH Solis Group, may local support naman yan. facebook.com/groups/413473389645478/?ref=share

  • @markgilder9990
    @markgilder9990 Před 2 lety

    About as clear as mud.

  • @anethemia7857
    @anethemia7857 Před 2 lety

    Good po sir mark,magkano ang 2kw solis sir?

    • @MarkMinoza
      @MarkMinoza  Před 2 lety

      sa OnePoint ko eto nabili, 1Kw and 3.6Kw ang available sa kanila. 12K bili ko sa 1Kw ko. 27K ang 3.6Kw nila

    • @anethemia7857
      @anethemia7857 Před 2 lety

      @@MarkMinoza yung output ng solis invrtr sir mark,saan dapat elagay sir sah input ng main breakr ng bahay sir?.

    • @anethemia7857
      @anethemia7857 Před 2 lety

      @@MarkMinoza maraming slmat sah mga sagot moh sir,alwys watchng ur vedios from cebu province.

  • @werdem
    @werdem Před 2 lety

    mali ata. nag ON nang EPM pero Generating parin. dapat LimByEPM. mag babayad ka sa meralco nya. dagdag load

    • @MarkMinoza
      @MarkMinoza  Před 2 lety +1

      Half of the vid po ata ang nakita nyo, or you skip it. 8:15 timeline ang limbyepm.

    • @werdem
      @werdem Před 2 lety +1

      @@MarkMinoza tama. hnd ko nakita limbyepm.

    • @MarkMinoza
      @MarkMinoza  Před 2 lety

      @@werdem pina generate ko muna para makita ko ang Peak harvest before enabling the limiter. Kasi pag enable nyo kaagad, palaging tanong ng iba, bakit ang baba ng harvest?

  • @llewellynala6807
    @llewellynala6807 Před 3 lety

    Sir ano ibig sabihin ng LimBEPM STATUS

    • @MarkMinoza
      @MarkMinoza  Před 3 lety

      Limited By EPM = active ang limiter po.

    • @llewellynala6807
      @llewellynala6807 Před 3 lety

      @@MarkMinoza meaning pag active na siya pagmag sobra ang supply ng pv solar hindi ko eto consumption? Tama ba?

    • @MarkMinoza
      @MarkMinoza  Před 3 lety

      @@llewellynala6807 hindi ka po mag export ng power sa grid. Pag sobra ang pv generation, e limit ng inverter, e supply lang nya anong current load mo sa bahay.

    • @llewellynala6807
      @llewellynala6807 Před 3 lety

      @@MarkMinoza curious lang talaga ako sir . Kasi meron ako clamp meter pagtumaas ang harvest napansin ko sa clamp meter ko tumaas din ang consumptions ko. Hindi kaya instead na makatipid eh mas lalong madadagdagan consumptiins ko sir? Or baka merong settings na kailangan ko pang e configure. Need your thoughts po sir. Tnx

    • @llewellynala6807
      @llewellynala6807 Před 3 lety

      Tsaka para wala kasing indicator dito sa screen kung nag produce at nag export ba etong grid inverter ko