  • How to install a washing machine and dishwasher downpipe and waste ON THE JOB!
    🚀 LEARN PLUMBING ONLINE IN MY STRUCTURED COURSE (50% Before March): www.learnplumbi...
    🛠 AMAZON TOOL STORE: www.amazon.co.u...
    🥾 10% Off my workboots + workwear Use Plumberparts10: www.bigboots.c...
    👓 10% Off Safestyle Sunglasses Use PLUMBER10: safestyle.com....
    Learn Plumbing Online is perfect for future apprentices, homeowners who want to understand and tackle more plumbing jobs in the home, handymen who keep turning down the odd plumbing job and more. With practical follow along video lessons and discussion board you can boost your knowledge in my amazing trade. Sign up now: wwwlearnplumbin...
    TWITTER🐤 / plumberparts 🔥
    FACEBOOK👉 / plumberparts 🔥
    INSTAGRAM📷 / plumberparts 🔥
    SNAPCHAT👻 / plumberparts 🔥
    -----
    ------
    -------
    PLUMBERS REGISTER HERE: www.plumberpart... ❤️

Komentáře • 56

  • @plumberparts
    @plumberparts  Před rokem +4

    A random job that I thought you'd enjoy!
    🛠 *_AMAZON TOOL STORE:_* www.amazon.co.uk/shop/plumberparts
    🥾 *_10% Off my workboots + workwear Use Plumberparts10:_* elwoodworkwear.co.uk/?ref=Plumberparts10
    👓 *_10% Off Safestyle Sunglasses Use PLUMBER10:_* safestyle.com.au/?ref=PLUMBER10

  • @nobodydoesithalfasgoodasyou

    Of all the guides on fitting waste pipe, this is one

  • @markyfromars
    @markyfromars Před rokem

    I never use joining compound but I use Loctite threadlocker on the threads to be sure😉. great stuff

  • @dimitar4y
    @dimitar4y Před rokem +4

    the FUNNIEST part is you giving up and bringing in a trolley :D

  • @stephengreen6338
    @stephengreen6338 Před rokem +4

    Hi James, I hope them two machines don't discharge at the same time, coz that downpipe don't look long enough, it could back flow out the pipe, hope ya tested it!!

    • @dimitar4y
      @dimitar4y Před rokem +1

      Then he'll get called back and he'll just get one of those spigot fittings and slap it right on, with zero chance of it ever overflowing again.

    • @joun456
      @joun456 Před rokem +1

      Waste is definitely too small for simultaneous discharge… 💦 Also no MEK before gluing? Clean your end before going in!!!

    • @dimitar4y
      @dimitar4y Před rokem

      @@joun456 the heck is a "MEK" or "clean your end before going in"

    • @gadgetman36
      @gadgetman36 Před rokem +1

      @@dimitar4yNot now he’s cut the rubbers off the two hoses!

    • @joun456
      @joun456 Před rokem

      @@dimitar4y methyl ethyl ketone, aka the correct degreaser prior to jointing PVC with adhesive. Two reasons- Firstly contamination on the mating surfaces stops it bonding correctly, mold release from manufacture or even finger prints. Secondly, MEK being pretty aggressive, also primes the surface for bonding, goes matte after cleaning, giving it a bit of a key to further improve adhesion 👍

  • @42RHD
    @42RHD Před 4 měsíci

    Fire extinguishers are good for holding laser levels. You should have one around anyway!

  • @TheTW11
    @TheTW11 Před rokem

    You can get adapters that provide a flat surface for the gasket at 11:01 instead of nipping up to a chamfered edge on that isolator.

  • @AaronM4275
    @AaronM4275 Před rokem

    I will put my life on it that youll be the one fitting the new prv when it eventually goes 😂 great video 👍

  • @ForTheTeoma
    @ForTheTeoma Před 2 měsíci

    Why are waste pipes always taken upward before entering the pipework? Washing machines in particular don't pump all the water out once air gets in, which leaves stagnating water in the grey pipes.

  • @stephenhaley2k3
    @stephenhaley2k3 Před rokem

    Question on how to achieve a decent fall on the drain pipe. The elbow fitting in the corner was glued so presumably not moving much. So do you just 'force' the pipe up at the downpipe side to create the fall?

  • @Leo99929
    @Leo99929 Před rokem +1

    Camera tripod works well for my laser level. It's got the right thread in the bottom.

  • @fionagregory9147
    @fionagregory9147 Před rokem +1

    Let's see your cat George again please.❤

  • @tylermorgan6020
    @tylermorgan6020 Před rokem +2

    Shouldn’t you install a double check valve before the washing machine connection ? Or is it not needed that’s how I’ve been taught

    • @plumberparts
      @plumberparts  Před rokem +2

      There's one on the water softener. Tbf it's probably overkill anyway...as are all regulations made up by men in suits and not men in boiler suits! 😂

    • @tylermorgan6020
      @tylermorgan6020 Před rokem +1

      @@plumberparts agreed 😂

  • @geeeeeeeezzzzzzzzzz
    @geeeeeeeezzzzzzzzzz Před rokem

    Just want to ask something. I have Willis Emersion heater attached to my hot water tank and if I try and use it then it seems to have gone into reverse flow!!!! The hot water should rise and enter the top of the tank but it seems to be blocked from flowing in that direction so it over boils (kettles apparently, people seem to use them for underfloor heating) and actually expels the hot water from the bottom (what is suppose to be the intake!) of the Willis unit so it can flow in that direction around the loop but not the normal direction which I suspect is some sort of debrie blocking the flow in one direction possibly and so it heats the hot water tank from the bottom and so takes ages and there is some amazing clanking and sucking orchestra to accompany it all lol. It used to work in the other correct direction but no longer so I guess it needs disassembled to see what is causing this possible blockage? It's an old awkward system to drain etc but when it worked properly it was great but now it's doing my head in.

  • @JayG2K
    @JayG2K Před rokem

    I never knew about cutting the rubber spigot off the appliance hose if it goes in to the upstand. hat happens if its left on?

  • @TheJask101
    @TheJask101 Před 7 měsíci

    Where do you join the members area? I can’t find the link?

  • @sergiofernandez3725
    @sergiofernandez3725 Před rokem +3

    Use a twin spigot adaptor with air vent is better than just shoving the 2 hoses in the down pipe

    • @JayG2K
      @JayG2K Před rokem +1

      good call that

  • @rlc2978
    @rlc2978 Před 9 měsíci +2

    Soo, just fix the new pipe over the valve handle and don't worry about it, job done, get paid, someone else's problem later? Got it.

    • @plumberparts
      @plumberparts  Před 9 měsíci

      Exactly that! Have a great life! 😂🙏

  • @MrDbone75
    @MrDbone75 Před rokem +1

    I am in hospital tonight whiching your vlog

  • @loafersheffield
    @loafersheffield Před rokem +3

    Yes! Got to wear that lab coat. Elf n safety. You forgot the following:
    Anti slip, non-conductive, steel-toed work boots.
    Natural fibred socks with antibacterial enzymes. (Stops you having to see if they stick to the wall, before you change them)
    Comfy undies.
    Flame retardant, branded work trousers incorporating ranti rip fibres, elephant eared storage pockets (just don't let your trunk hang out in public)
    Gloves.
    Flame retardant shirt (bra is optional, even for men. Moooobs!)
    Stab vest, welders helmet, ear/nag defenders (See Loafer's missus)
    Air raid siren warning of impending doom and wallet on a sturdy chain.
    I must have forgotten something? 🤔
    All suggestions appreciated.

    • @gadgetman36
      @gadgetman36 Před rokem +1

      He didn’t even fasten the lab coat, so that was also a fail! 😂

  • @Solidsnake0208
    @Solidsnake0208 Před rokem

    check out the plumberparts mandem and their sick grimebeats on the intro fam!

  • @AbsoluteOatcake
    @AbsoluteOatcake Před 4 měsíci

    Gary Rowett

  • @TheScottelias
    @TheScottelias Před 11 měsíci

    All that science and not a single magnet or laser… when you order science from Wish

  • @gadgetman36
    @gadgetman36 Před rokem +1

    I don’t agree with cutting the rubbers off. I’ve been using a twin spigot adapter compression fitting on a 40mm downpipe since 2010.

  • @andrewbaker7548
    @andrewbaker7548 Před rokem

    Why would anyone drill into mortar joints for a decent fixing!

  • @RexBanner_
    @RexBanner_ Před rokem +1

    🔥

  • @GrahamSmart
    @GrahamSmart Před 6 měsíci

    Compression fittings without compound just leak. Always leak.

  • @johnbower
    @johnbower Před 8 měsíci

    Very poor installation, If you cut into that waste pipe at the correct height then the pipe waste pipe you installed would not have crossed in front of that existing wall mounted valve, also the length of waste pipe you fitted along the wall would not have had to slope up so steeply in order for the U bend to miss the existing copper pipe work.

  • @fatwalletboy2
    @fatwalletboy2 Před rokem +1

    The thumb nail pic looks a bit naughty.....look at it again! Looks like youve whipped out ya chopper!

    • @mda5003
      @mda5003 Před rokem +1

      Wishful thinking...... 🤣

  • @Englshman1970
    @Englshman1970 Před měsícem

    Why you dressed like neo

  • @ownyourworld
    @ownyourworld Před rokem

    Not Mcalpine urgh 😂

  • @marshtermind
    @marshtermind Před rokem

    Them fluxuators are crap mate

    • @plumberparts
      @plumberparts  Před rokem

      Ah mate mine's great. Apart from the brush bit at the back. What's wrong with your one? I'll tells Debs.

    • @marshtermind
      @marshtermind Před rokem

      @@plumberparts much easier to use a tub of flux with a hole in the top. Can spread it evenly and quicker especially on price work

  • @jeffrey01UK
    @jeffrey01UK Před rokem

    Not one of your best jobs 😂. Back runs don’t work on ikea kitchens - have to do it at floor level