#ETSRoom

Sdílet
Vložit
  • čas přidán 25. 06. 2020
  • #chiller #chilledwater #coolingsystem
    Subscribe Now czcams.com/users/hbtv2020?sub...
    Here are more Interesting video about HVAC System, Please have a look.
    #Ducting for Bigger Area along with VAV & VCD, Adjusting Flow Rate L/s as per Area with Eng Sub/CC • #Ducting for Bigger Ar...
    #VAV Controlling with Thermostat & BMS System along with Occupancy Sensor Wiring with DDC Eng Sub/CC • #VAV Controlling with ...
    What's ETS Room? What are the Equipment's Inside & their Purpose? Chilled Water Pipe line Network. • #ETSRoom What are Equ...
    Chilled Water #PressurizationUnit |Explanation about #PressureSwitch & #PressureVesselTank • Chilled Water #Pressur...
    Plate #HeatExchanger in the #DistrictCoolingSystem Primary & Secondary Pipe line Purpose/Working All • Plate #HeatExchanger i...
    Chilled Water Automatic & Manual Chemical Dosing System in the District Cooling System full Detail • Chilled Water Automati...
    FAHU|Exhaust Air & Supply Air System|Heat Recovery Wheel|Filter Types|Cooling Coil| Air Blower| • FAHU | Fresh Air & Exh...
    Air Handling Unit works |Different Types of Filters|Chilled Water System Along with Temp&Pressure| • Air Handling Unit work...
    Chilled Water #PressurizationUnit |Explanation about #PressureSwitch & #PressureVesselTank • Chilled Water #Pressur...
    HVAC Chilled Water Pumping System|Controlling of CHW Flow|Pipping#Strainer Motor Plate Info #ETSRoom • HVAC Chilled Water Pum...
    Actuator/Motorized Valve|Wiring|Connection|Working|1way&2Way|Manually Control| BMS Control | • Actuator/Motorized Val...
    How does Thermostat works, Connection, Addressing and Operation Full Detail • How does Thermostat wo...
    BMS Control Panel which apply to FCU, How Devices are been wired & DDC Card Full Detail • BMS Control Panel whic...
    Differential Pressure Transmitter/Air Velocity meter Working Principle, Installation & Wiring Detail • Differential Pressure ...
    BTU Meter/Water flow meter/Temperature meter their units of measure/Installation/Connection all here • BTU Meter/Water flow m...
    Explanation about Fan Coil Unit, FCU parts, Actuator and DRV Valve with English Substiles • Explanation about Fan ...

Komentáře • 72

  • @sayyedadnan4062
    @sayyedadnan4062 Před rokem

    Bahot Shandaar

  • @chanddar78
    @chanddar78 Před 4 lety

    Thanks for Sharing this knowledge

  • @muahammadjahangir6014
    @muahammadjahangir6014 Před 2 lety

    Good jazak Allah

  • @kazirahim4764
    @kazirahim4764 Před 3 lety

    Good information 👍

  • @rakeshdsouza166
    @rakeshdsouza166 Před 3 lety

    Good explanation . Thank you bro

    • @HBTV2020
      @HBTV2020  Před 3 lety

      Thanks please support my channel

  • @stifanfernandes1170
    @stifanfernandes1170 Před rokem

    Tq sir

  • @saddamhussain-rx8hq
    @saddamhussain-rx8hq Před 3 lety

    Good knowledge bro Thanks for sharing knowledge 👍

    • @HBTV2020
      @HBTV2020  Před 3 lety

      my pleasure please support my channel as much as you can thanks

  • @amarjits268
    @amarjits268 Před rokem

    Thanks brother.

  • @sachinkp4504
    @sachinkp4504 Před 3 lety

    Superb bro... 👌

    • @HBTV2020
      @HBTV2020  Před 3 lety +1

      Thanks Bro please support my channel as much as you can

  • @sherazlodhi2222
    @sherazlodhi2222 Před 3 lety

    good work buddy!

    • @HBTV2020
      @HBTV2020  Před 3 lety

      My pleasure ! please support my Channel

  • @SandeepYadav-wj1kr
    @SandeepYadav-wj1kr Před 3 lety

    Good information sir

    • @HBTV2020
      @HBTV2020  Před 3 lety

      Thanks g Please support my Channel

  • @manishshet3577
    @manishshet3577 Před 3 lety

    Love you brother good

    • @HBTV2020
      @HBTV2020  Před 3 lety

      thanks g plz support my channel as much as you can

  • @kulwindersingh9279
    @kulwindersingh9279 Před 3 lety

    nice work

  • @BlueStormRage
    @BlueStormRage Před 9 měsíci

    What I understood from this is that he is saying cooling tower instead of District Cooling Plant". In UAE we had Empower (DCP) to supply CW. Following HEXs there is no other cooling media for the CW to further cool the water. DCP supplies at the temperature of 4 to 5C to the building. Delta to be maintained as per the energy parameters specified by the in the contract.
    However, still good video! Thanks.

  • @TanweerAhmed
    @TanweerAhmed Před 3 lety

    Good and informative

    • @HBTV2020
      @HBTV2020  Před 3 lety +1

      Thank you so much Sir! Even I have learnt many things from your videos.

    • @TanweerAhmed
      @TanweerAhmed Před 3 lety

      @@HBTV2020 Welcome, we learn and teach eachother

    • @HBTV2020
      @HBTV2020  Před 3 lety +1

      @@TanweerAhmed Of course Sir,

  • @gksam1987
    @gksam1987 Před 6 měsíci

    Sir this system where
    ..i think samatower in dubai sheikzeydroad

  • @nejeebmullappalli7039
    @nejeebmullappalli7039 Před 3 lety +3

    I think the line to heat exchanger is from District Cooling plant Chiller not from the Cooling tower, cooling tower might be in District Cooling plant, cooling tower is connected to Chiller not to the Heat Exchanger. The temperature at cooling tower line might be above 30 deg or some what near to ambient temperature

    • @HBTV2020
      @HBTV2020  Před 3 lety

      There is a cooling tower along with chiller in the District cooling plant in UAE. Return water gets cooled by cooling tower and Chiller as well.

    • @nejeebmullappalli7039
      @nejeebmullappalli7039 Před 3 lety +1

      @@HBTV2020 Ok, do you mean there are two cooling towers, 1 . condenser side of chiller at district cooling plant and 2. Return water side means, another cooling tower between heat exchanger at building and chiller at district cooling plant

    • @altamashshah2035
      @altamashshah2035 Před 2 lety +2

      @@HBTV2020 Boss you are speaking wrong...Return Water only gets cooled in Chiller Evaporator ..It has nothing to do with Cooling Tower .Check you Schematics to understand the concept.

    • @altamashshah2035
      @altamashshah2035 Před 2 lety +1

      @@nejeebmullappalli7039 He is speaking wrong...Chilled Water Supply & Return both are from Chiller Only. Throughout the video he said Cooling Tower which is wrong.

    • @erpoint2661
      @erpoint2661 Před 7 měsíci +1

      First you take knowledge then you make video

  • @Ali_Alhamaly
    @Ali_Alhamaly Před 6 měsíci

    The problem is that the English subtitle is not for the whole video, only a short intro at beginning

  • @villagegallery8531
    @villagegallery8531 Před 5 měsíci

    Where is this plant ?

  • @BasitAli-uy3pc
    @BasitAli-uy3pc Před rokem

    Bro how to connection of sensor and hose tube with chemical dosing pump

  • @villagegallery8531
    @villagegallery8531 Před 5 měsíci

    Where is this plant bro ?

  • @mohammadshahnawaz6165
    @mohammadshahnawaz6165 Před 2 lety

    De coupler motorized valve when should be open and closed

  • @raiannurislam
    @raiannurislam Před 2 měsíci

    2:10 chilled water is coming from cooling tower or chiller?

  • @shirazalam3633
    @shirazalam3633 Před 3 lety

    Pump rooms ke bhi video bnao bhai..
    Example: irrigation pump room, Rain water pump room, water feature pump room e.t.c

    • @HBTV2020
      @HBTV2020  Před 3 lety

      G g In Sha Allah agar ap fire pump room k barey mein jana chaty hain is link per click karain
      czcams.com/play/PL00BpsWfqvo5E40WkYsQbknzhHiuuRJtu.html

  • @alijahyusuf6827
    @alijahyusuf6827 Před 3 lety

    Can you show us this cooling tower system

    • @HBTV2020
      @HBTV2020  Před 3 lety

      I will try to make a video on this topic

  • @mdakhil2647
    @mdakhil2647 Před 3 lety

    Thanks for the vedio
    Sir, normally chiller system me water from the chiller dirct given to Ahu
    Aur district cooling me kyun heat exchangers use karte hai jabki hamare paas delta T(5degree) maintain kiya hua hai aur required gpm to milta hi hai main district cooling system piping se
    Heatexchanger se hota kya hai sir

    • @HBTV2020
      @HBTV2020  Před 3 lety

      The chilled water has been provided by a outside company they having very big cooling tower and chiller station for big Island
      The purpose of the heat exchanger that consumer can maintain their own temperature in the building and service provider can maintain their standard temperature and it will help to calculate the consumption
      Consumer has to maintain particular Delta T otherwise service provider can fine the consumer because its effect their plant efficiency
      And if consumer by mistakenly made bigger change to their system secondary side it will not immediate effect on service provider company

  • @guddukryadav7507
    @guddukryadav7507 Před 4 lety

    Hello sir es system me water cooled kaise ho raha plate types heat exchanger me kya gas hota Ha or chiller se kaise cooled ho raha hai plazzz give me answer sir

    • @HBTV2020
      @HBTV2020  Před 4 lety +1

      Water cooled cooling tower mein hota hai jahan pani ko Air k 7 thanda kia jata hot water ko fowarey ki trah air k 7 contact kia jata jis sey pani ka temperature kam ho jata yani thanda ho jata hai or plate heat exchanger mein koi gas ni hoti primary side low temperature water pass kia jata hai jo k secondary side mein majud pani ko transfor hoja ye kam sirf heat exhange k material ki waja se hota hai hope ap ka concept clear ho gya ho ga

  • @RejoiceAlbaran1994
    @RejoiceAlbaran1994 Před 2 lety

    You dont have English subtitle?

    • @HBTV2020
      @HBTV2020  Před 2 lety

      Sorry for that I will complete Eng Substiles soon

  • @mdbelalsheikh9126
    @mdbelalsheikh9126 Před 3 lety

    Dear I want discuss on HVAC regarding pls reply me.

    • @HBTV2020
      @HBTV2020  Před 3 lety

      yes plz tell what you want to ask

  • @exterminator4808
    @exterminator4808 Před 3 lety

    Is this building being supplied from some district cooling system? Or are the cooling towers exclusive to this building only? Also, 5 degree centigrade chilled water coming from the cooling tower? In the Middle East? I have a feeling something is missing.

    • @HBTV2020
      @HBTV2020  Před 3 lety +1

      Thank you so much for watching
      Yes this chilled water is being supplied by district cooling company
      There is no cooling tower for this building there is a common cooling tower for whole Island
      Yes it is in Middle East

    • @exterminator4808
      @exterminator4808 Před 3 lety

      @@HBTV2020 Brother I think you have the wrong idea. Cooling towers cannot provide water of temperature 5 degree C. The district cooling system utilises chillers to chill water and the heat removed from this chilled water is rejected to the atmospheric air through the cooling towers. It is true that cooling towers alone are also used to provide chilled water but only in winters and that too in western countries where the winters are real cold. But in the Middle East, it is impossible for a cooling tower alone to chill water to 5 degree C. Think about it.

    • @HBTV2020
      @HBTV2020  Před 3 lety +1

      @@exterminator4808 In cooling tower water get cold with two different ways
      first water pass through form cooling tower rejected heat in the atmosphere than it pass through from chillers (chiller evaporator section) which decrease more water temperature then it distributed to the different project
      Even it is possible to gain even 1 Degree Celsius water temperature from cooling tower
      Since cooling Tower receive return chilled water temperature approximately 16 degree which can be reduced into 5 degree Celsius by air cool only
      if outside temperature too high or high Relative humidity level then they use chiller to lower down the temperature of chilled water

    • @exterminator4808
      @exterminator4808 Před 3 lety

      @@HBTV2020 So chillers are used in series with the cooling towers to reduce load on the chillers i.e free cooling.

    • @HBTV2020
      @HBTV2020  Před 3 lety

      @@exterminator4808 Yes, you got me.

  • @melechvestido1102
    @melechvestido1102 Před rokem

    Katsara design

  • @rohan__boy95
    @rohan__boy95 Před 3 lety

    Sir
    Heat exchanger me cooling tower se kyu ayega wo to sirf chiller evaporator se ayega aur HEX se unwanted heat absorb krega

    • @HBTV2020
      @HBTV2020  Před 3 lety

      Chill water ko cold karne ke liye cooling tower yah chiller use Kiya Jata Hai depend on project design
      Chiller se sirf ek building ke water ko hi cold Kiya Ja sakta hai Jab Ke cooling tower se a multiple buildings ke liye water ko code kiya Ja sakta hai jo ki energy-efficiency Jyada Rakhta hai hai vah Bling cost per kam hoti hai

    • @rohan__boy95
      @rohan__boy95 Před 3 lety

      @@HBTV2020 it's new concept for me, till now I know cooling tower is used for Condenser water cycle for water cool chiler

    • @altamashshah2035
      @altamashshah2035 Před 2 lety

      @@rohan__boy95 You are Correct...He is giving wrong information altogether

  • @exterminator4808
    @exterminator4808 Před 3 lety

    I have a genuine question: why are plate and frame heat exchangers being used here? Why not connect the lines directly to the cooling tower? Why maintain 2 water loops and consequently 2 sets of pumps? PHX se to heat transfer efficiency ghat ta hai.

    • @HBTV2020
      @HBTV2020  Před 3 lety +1

      The chilled water has been provided by a outside company they having very big cooling tower and chiller station for big Island
      The purpose of the heat exchanger that consumer can maintain their own temperature in the building and service provider can maintain their standard temperature and it will help to calculate the consumption
      Consumer has to maintain particular Delta T otherwise service provider can fine the consumer because its effect their plant efficiency
      And if consumer by mistakenly made bigger change to their system secondary side it will not immediate effect on service provider company

  • @QasimIbrar
    @QasimIbrar Před 2 měsíci

    CHW lines from the cooling tower????
    seriously...

  • @mischellesanjose4680
    @mischellesanjose4680 Před 3 lety

    English please

    • @HBTV2020
      @HBTV2020  Před 3 lety

      There is a English Subtitles with the video please check on CC on the right hand side bottom

  • @ajmalsharif1
    @ajmalsharif1 Před 7 měsíci

    Prepaired your self before making such clip. By your self you are confused between cooling tower and chilled water lines.

  • @mohammedjahangir974
    @mohammedjahangir974 Před 10 měsíci

    Bhai sab aap sahi samjha nahi parahe hu phir se samjhao

  • @mdrabbani6523
    @mdrabbani6523 Před měsícem

    😂😂😂😂 ja kebseekh feer se

  • @mhworld3898
    @mhworld3898 Před rokem

    Wrong information bhai pahle tum khud janlo tum kya bolrahe ho Uske bad video banana.CT •5 tem Ata hai yar kuch v bolejara hai.😀😀😀

  • @user-gu1yw1fl6x
    @user-gu1yw1fl6x Před 2 měsíci

    Bhai please send email