- 194
- 2 114 495
Helpful & Bright TV
Pakistan
Registrace 13. 03. 2020
CFM Measurement + & - Air pressure in the high raise building Extech AN100 AN200 HVAC Anemometer
#cfm #EXtech #HAVC
Subscribe Now czcams.com/users/hbtv2020
Subscribe Now czcams.com/users/hbtv2020
zhlédnutí: 679
Video
How to use Digital Tachometer RPM Meter Speed Meter for measuring the Motor RPM On & Off Load
zhlédnutí 2,6KPřed rokem
#rpm #tachometer #motorspeedsensor Subscribe Now czcams.com/users/hbtv2020
ATS (Automatic Transfer Switch) Panel with DC Power Source along with Generator Purpose/Working All
zhlédnutí 2KPřed rokem
#atspanel #automatictransferswitch #backuppower Subscribe Now czcams.com/users/hbtv2020
FAHU Control Panel | Hight Rated Motor control by Star Delta | Motor Auto Start & Manual Start |
zhlédnutí 6KPřed 2 lety
#motorcontrol #stardelta #controlpanelwiring Subscribe Now czcams.com/users/hbtv2020
Refrigerant Recovery Procedure / Gas Recovery from Chiller by Recovery Machine fill into Cylinder
zhlédnutí 2KPřed 2 lety
#aircooledchiller #refrigerant #chillerac Subscribe Now czcams.com/users/hbtv2020
Flash Tank / Economizer in Air Cooled Chiller with Electronic Expansion Valve and Refrigerant Cycle
zhlédnutí 7KPřed 2 lety
#economizer #chillerplant #Expansionvalve Subscribe Now czcams.com/users/hbtv2020
Air Cooled Chiller w8 VSD Technology Flush Tank Economizer Screw Compressor Electric Expansion Valve
zhlédnutí 2,5KPřed 2 lety
#chiller #aircooledchiller #HVAC Subscribe Now czcams.com/users/hbtv2020
Three Way Valve with Actuator It's Purpose in Chilled Water System or HVAC System Practically Shown
zhlédnutí 3KPřed 2 lety
#3wayvalve #Electricvalve #cooling Subscribe Now czcams.com/users/hbtv2020
24 Volt with 0 to 10 DC Volt Actuator / Motorized Valve & Two Way Valve in FCU/ Chilled Water System
zhlédnutí 17KPřed 2 lety
#Twowayvalve #motorizedvalve #actuator Subscribe Now czcams.com/users/hbtv2020
Commercial UPS 100 KVA with Battery Bank Wiring & Purpose Difference between Generator & UPS Power
zhlédnutí 7KPřed 2 lety
#ups #inverter #batterybank Subscribe Now czcams.com/users/hbtv2020
VRF Variable Refrigerant Flow or VRV Variable Refrigerant Volume in HVAC Explained Practically
zhlédnutí 674Před 2 lety
#VRF #VRV #vrfsystemdesign Subscribe Now czcams.com/users/hbtv2020
Zone Control Valve & Flow Switch Internal Structure & Connection for Wet Firefighting System
zhlédnutí 13KPřed 2 lety
#firefighting #flowswitch #zonecontrolvalve Subscribe Now czcams.com/users/hbtv2020
DRV Valve in the Chilled Water Cooling System / Cooling Issue Resolved by doing this 4 FCU AHU FAHU
zhlédnutí 17KPřed 2 lety
#DRVvalve #acnotcooling #hvac Subscribe Now czcams.com/users/hbtv2020
How to Disable & Enable Smoke / Heat Detector & Pull Station from Addressable Fire Alarm Panel
zhlédnutí 15KPřed 2 lety
#addressablefirealarmsystem #firealarmsystem #firedetectionsystem Subscribe Now czcams.com/users/hbtv2020
Changeover Timer for Hot/Cold Circulation Pumps Wiring & Setting / Pump Controller / Pump with Motor
zhlédnutí 1,6KPřed 2 lety
#electricaltrainingvideos #electricalcontrolpanel #timerrelay Subscribe Now czcams.com/users/hbtv2020
Electrical Distribution Board Types DB EDB UDB & their load. Different types of DB by Section & Way
zhlédnutí 3,5KPřed 2 lety
Electrical Distribution Board Types DB EDB UDB & their load. Different types of DB by Section & Way
A/c Package Unit Control Panel Wiring Toggle Switch LP/HP Switch On Delay Relay Phase failure Relay
zhlédnutí 987Před 2 lety
A/c Package Unit Control Panel Wiring Toggle Switch LP/HP Switch On Delay Relay Phase failure Relay
Connection & Purpose of On Delay Relay for Compressor in DX Package Unit's Control Panel Eng Subs/CC
zhlédnutí 1KPřed 2 lety
Connection & Purpose of On Delay Relay for Compressor in DX Package Unit's Control Panel Eng Subs/CC
Emergency Light Wiring with Addressable Module, Battery, Charging Circuit & Control Panel CBU System
zhlédnutí 4,9KPřed 2 lety
Emergency Light Wiring with Addressable Module, Battery, Charging Circuit & Control Panel CBU System
#EasiCheck Emergency Lighting System Login Password Enable/Disable Light Functional Test/Programing
zhlédnutí 2,4KPřed 2 lety
#EasiCheck Emergency Lighting System Login Password Enable/Disable Light Functional Test/Programing
LPG / Natural Gas Pressure Reducing from 4 bar to 20 mbar/ Resting of Gas Solenoid & Regulator
zhlédnutí 3,6KPřed 3 lety
LPG / Natural Gas Pressure Reducing from 4 bar to 20 mbar/ Resting of Gas Solenoid & Regulator
Gas Distribution System In Commercial Kitchen with Regulator Solenoid Valve Gas Detector Push Button
zhlédnutí 6KPřed 3 lety
Gas Distribution System In Commercial Kitchen with Regulator Solenoid Valve Gas Detector Push Button
Cooper / Eaton Emergency Light / Emergency Exit Light Driver / Ballast Connection & Programming
zhlédnutí 2,7KPřed 3 lety
Cooper / Eaton Emergency Light / Emergency Exit Light Driver / Ballast Connection & Programming
Swimming Pool Circulation Pumps along with Skimmer Water Filtration Process in Hindi+Eng Sub/CC
zhlédnutí 1,1KPřed 3 lety
Swimming Pool Circulation Pumps along with Skimmer Water Filtration Process in Hindi Eng Sub/CC
Swimming Pool System with Balancing Tank Chemical Dossing Heat & Cool System Vacuuming Hindi+Eng Sub
zhlédnutí 39KPřed 3 lety
Swimming Pool System with Balancing Tank Chemical Dossing Heat & Cool System Vacuuming Hindi Eng Sub
Astralpool Multi Port Valve for Swimming Pool for Filter Backwash Rinse Recirculate Hindi+Eng Sub/CC
zhlédnutí 5KPřed 3 lety
Astralpool Multi Port Valve for Swimming Pool for Filter Backwash Rinse Recirculate Hindi Eng Sub/CC
Three phase SPD or Surge Protection Device Connection/Purpose/Working & Types in Hindi+Eng Sub/CC
zhlédnutí 3,5KPřed 3 lety
Three phase SPD or Surge Protection Device Connection/Purpose/Working & Types in Hindi Eng Sub/CC
24V / 220 V Magnetic Contractor Connection NO NC Contacts use for Control Wiring in Hindi+Eng Sub/CC
zhlédnutí 1,2KPřed 3 lety
24V / 220 V Magnetic Contractor Connection NO NC Contacts use for Control Wiring in Hindi Eng Sub/CC
Overload relay Auxiliary contacts, Testing Procedure & Connection with Contactor in Hindi+Eng Sub/CC
zhlédnutí 1,7KPřed 3 lety
Overload relay Auxiliary contacts, Testing Procedure & Connection with Contactor in Hindi Eng Sub/CC
Street Light Timer / Analog Timer Setting & Connection Along with LCP Panel ( knx ) Hindi+Eng Sub/CC
zhlédnutí 2,8KPřed 3 lety
Street Light Timer / Analog Timer Setting & Connection Along with LCP Panel ( knx ) Hindi Eng Sub/CC
What about Wifi limit usage?? 😢
Please ACB ko Rack Inn and Rack out kar k dhikhaye...with complete guidance 🙏 thanks
czcams.com/video/y0M6NjnAbak/video.html have a look please
Informative video thank you
Bro can U make it control wiring fully
Ek apartment ke under Kitna flow tak jaaega BTU meter me
Ye koun sa bhsa bol rahahay masid masid bar bar
Apka chanel subscribe Kiya over notification b on Kiya he Thanks
Bahut hi acha he bai khosh rahe
Abhe chootye 0 to 10 v dc k connection to bta kahan se dene hain
How to operate manual
Engine ka control me red indicator Kyu jal raha hai how to solved what is the reason
Suction pressure kitna hota hai please reply
😂😂😂😂 ja kebseekh feer se
Thanks, was very helpful.
Jb coil working na kre oor charging lever working na kre to breaker ko on kese kree?
Kubur kubur kubur kubur kubur kubur kubur kecikkubur 123455432123445543321234454332123454321kg sepakat alur dalam 5432123 0:28
Bhai please send email
CHW lines from the cooling tower???? seriously...
Great video sensor calibration pe ek video please
very informative
2:10 chilled water is coming from cooling tower or chiller?
❤
Why have you installed both simultaneously?
Ets kaise learn kare
How to setup this extech flow meter
Ahu child water systom suply line in comeing retunair actvater using after go ouf supply air coolinv lord afyef acvater op ot go chil water air passing pump premier secondry pump ahu usind in cool passinv
Very informative video
What is the source of the water that gets supplied to the building (building cooling loop) ?
Secondary side water to building kidar se supply hote… please reply
Mujhe es ka course krna h. Kaha hota h mujhe btaye.
Good video sir ji Load ko off kiye Bina bus coupler kese on kar sakte he If we have critical load
Manul Program kese hota hai
What cause buzzing sound from inside acb?
Sir please explain air cooled chiller and primary pump, second pump.
Wet chemical ma kon sa chemical milega kitchen suspension system
داداش دمت گرم
ETS ka SACAD display k bare m video chahiya please
Please speak English. I only understand ENGLISH and a little bit Punjabi like Pajee, Sascrika, Namosta ......😂
❤
information video Thanks eng
Bhaii give me mail id
Where is this plant bro ?
Where is this plant ?
Sir agar ye kharab howa toh kaise change kare
SBC?
Ashan . I'm suresh
Good knowledge
10ma RCCBs not available in the market.
Good 👍 keep it up
Zabardast vedio hai