Main and Transfer bus bar Differential Protection | Bus bar protection 7SS85 relay testing

Sdílet
Vložit
  • čas přidán 20. 08. 2024
  • In this video the topic discussed about Main and Transfer bus bar Differential Protection | Busbar protection 7SS85 relay testing
    and also why we go for check zone.
    only demo not actual testing
    and also primary testing for low impedance bus bar testing.

Komentáře • 32

  • @prabhakarangovindaraj9238

    Really very easily I understanded thank you for my 💓

  • @chandrannarayanan1072
    @chandrannarayanan1072 Před 4 lety +2

    Good bro understandable teach this is we want always you done it

  • @ziaullah-nz9fd
    @ziaullah-nz9fd Před 4 lety +1

    Nice work, keep it up.
    A little suggestion from my side.
    Kindly give a schedule for up coming videos. So everything should be in proper way. In this way, your viewers including me will have more interest and regularly visit your channel. Waiting for your answer.

    • @baranitech1026
      @baranitech1026  Před 4 lety

      thank you for this valuable information . i will make notification here after.

  • @chandrakantaroutray2003
    @chandrakantaroutray2003 Před 2 lety +1

    hey very nicely explained all videos , can u please make session on
    1. how siemens MCU configured for LBB & BUS bar protection.
    2. how bus bar differential for double bus bar system with check zone & bus zone works like main & transfer bus system.

    • @baranitech1026
      @baranitech1026  Před 2 lety +1

      yes i will make one by one after generator protection

  • @sriramamurthy6384
    @sriramamurthy6384 Před 4 lety +1

    Thanks bro, good explanation.

  • @manikandan-oy1rx
    @manikandan-oy1rx Před 4 lety +1

    Great job

  • @sandeepramkumar7503
    @sandeepramkumar7503 Před 4 lety +1

    Thank you sir

  • @muhamedmuneer4540
    @muhamedmuneer4540 Před 4 lety +2

    Can u make video for principle of pilot wire differential protection please?

    • @Krishna-qm5qk
      @Krishna-qm5qk Před 3 lety

      I too request, especially solkor R/RF. Thank Ji..

  • @furqanazam2776
    @furqanazam2776 Před 4 lety +1

    Awesome 👍🏻

  • @jayshankarkumar7681
    @jayshankarkumar7681 Před 3 lety +2

    Sir videos on resistive reach setting in line protection

    • @baranitech1026
      @baranitech1026  Před 3 lety +1

      after touching generation protection i will make this topic

    • @jayshankarkumar7681
      @jayshankarkumar7681 Před 3 lety

      @@baranitech1026 thanks sir. I'm very thankful💕 to you sir.

  • @sagormohammad349
    @sagormohammad349 Před rokem

    When BC is closed then Z1 current is =i1+i2 =. 33+.5 for inc and BC. Why take. 33-.33=0. Video 15:45 min

  • @sureshpadhy2243
    @sureshpadhy2243 Před 3 lety +1

    Please explain bus differential protection for one and half breaker system

  • @Krishna-qm5qk
    @Krishna-qm5qk Před 3 lety +1

    My doubt is why the check zone doesn't consider the bus coupler CT current? If it is considered how will it reflect?

    • @baranitech1026
      @baranitech1026  Před 3 lety

      Check zone only considered current in &out but bus coupler is common so it should not considered. If we take in account then current will get add

    • @Krishna-qm5qk
      @Krishna-qm5qk Před 3 lety +1

      @@baranitech1026 thanks for your reply.

  • @electricaltalks1723
    @electricaltalks1723 Před 3 lety +1

    hi sir in the settings differential current =1 i/ir obj , what is the meaning of i/ir objective

  • @chandrannarayanan1072
    @chandrannarayanan1072 Před 4 lety +2

    How to test in Siemens 7SS52 relay

    • @baranitech1026
      @baranitech1026  Před 4 lety +1

      for configuration of 7SS52 i will make video bro

    • @baranitech1026
      @baranitech1026  Před 4 lety +1

      next video it will be slope and it will be use full for testing

  • @prabha7363
    @prabha7363 Před 4 lety +2

    Really very easily I understanded thank you for my 💓

  • @himanshu2232
    @himanshu2232 Před 4 lety +1

    Thanks sir