EICR With Apprentice - Coding Talk, Main Heads and Interesting Wiring 😂

SdĂ­let
VloĆŸit
  • čas pƙidĂĄn 15. 09. 2020
  • In this episode I run through an EICR with Adil at a property in North London.
    Instagram: / delroythespark

Komentáƙe • 48

  • @barrysharp3559
    @barrysharp3559 Pƙed 3 lety +13

    Just subscribed Delroy, nice to see a fellow spark working on real jobs in the real world unlike some sparky channels who seem to cherry pick the pretty pretty jobs!! Keep up the Vids pal.

  • @g.williamswilliams8442
    @g.williamswilliams8442 Pƙed 3 lety +5

    More examples of " Safe Isolation " 😁
    Cover off , breakers and main isolator On 😁
    Excellent 😁

  • @mfr58
    @mfr58 Pƙed 3 lety +5

    You can spur to a 13A fused outlet in 1.5mm from the ring circuit. H2.3 Onsite Guide.

  • @Daniellee-gs6ef
    @Daniellee-gs6ef Pƙed 3 lety +2

    Nice to see you taking the time to walk him through and explain what needs doing.

  • @matthewbolton4063
    @matthewbolton4063 Pƙed 3 lety +2

    nice1 del looking after the young apprentice and showing him the ropes :) another good watch

  • @8squared563
    @8squared563 Pƙed 3 lety +7

    the incoming sub standard cast iron DNO head/cut-out definitely need to be replaced, it will have a rewirable main fuse which is likely to be asbestos mounted

  • @MMG_MoonManGuitar
    @MMG_MoonManGuitar Pƙed 3 lety +4

    Fantastic insight as usual Del. đŸ”„

  • @RexBanner_
    @RexBanner_ Pƙed 3 lety +1

    Great vid Delroy!

  • @billsmba
    @billsmba Pƙed 3 lety +6

    I was amazed to actually see Delroy at Canning town London today, first time i saw someone who does CZcams & actually get to meet them in real life, keep up the good work Spark, iv been a spark for 15 years but its nice to see you helping other engineers out there bless

  • @steveday7510
    @steveday7510 Pƙed 2 lety +1

    Another great video! I work a lot with the elderly and social housing, your content is always great and the properties are more like the ones I attend! So as Ali G would say "keep it real"

  • @johnschlesinger2009
    @johnschlesinger2009 Pƙed 3 lety

    Very thorough testing of a ropey installation. You're teaching Adil really well. That service head looks as though it has rewirable fuses: the supply authority will almost certainly change it.

  • @Cablesmith
    @Cablesmith Pƙed 3 lety +1

    Great video Del đŸ‘ŒđŸŒ

  • @ek6868
    @ek6868 Pƙed 3 lety +2

    Tanx for the upload plz do some more fault finding videos👍

  • @peterwilson6503
    @peterwilson6503 Pƙed 3 lety +2

    Delroy and your son do excellent job for your business and customers fare play

  • @ishkebab
    @ishkebab Pƙed 3 lety +5

    6mm bonding conductors are more than adequate on a TNS earthing arrangement, they are required to be no less than half that required of the earthing conductor and no less than 6mm, it’s only where pme conditions apply where table 54.8 is required to size the bonding conductors.
    You cannot code them for being 6mm if it’s a non pme installation.

    • @ishkebab
      @ishkebab Pƙed 3 lety

      K C No it doesn’t play a part, the danger of no rcd protection to a lighting circuit does not change because of the age, the risk is still there, it’s either immediately dangerous, potentially dangerous or improvement recommend, 20 years 10 years, 5 years, the risk doesn’t change.
      An installation doesn’t have to comply to the latest wiring regulations, there’s no law that means you have to comply with the latest edition of the wiring regulations, that is why a C3 code exists.
      All installations that are to an earlier edition do not mean they are unsatisfactory for continued use.

    • @ishkebab
      @ishkebab Pƙed 3 lety +1

      K C Taken from the BPG 4 and guidance note 3. The results of the inspection and testing need to be clearly detailed in a report. Any observed damage, deterioration, defects, dangerous conditions and non-compliances with the requirements of the current edition of BS 7671 that may give rise to danger should be recorded (Regulation 653.2) and appropriately classified for remedial action.
      It should be borne in mind that, as stated in the introduction to BS 7671, existing installations that have been constructed in accordance with earlier editions of the Standard may not comply with the current edition in every respect, but this does not necessarily mean that they are unsafe for continued use or require upgrading.
      My own home is 6 years old, it now does not comply to the current edition of bs7671 however it is in a satisfactory condition even with a plastic CU but it does not require to be brought in line to the current edition of bs7671.
      Installations pre 1966 did not require a cpc to the lighting circuit, this is unacceptable to today’s safety standards and would always be coded, the edition it was installed to is irrelevant, it may have complied once but it is now unacceptable.

    • @Mainly_Electrical
      @Mainly_Electrical Pƙed 11 měsĂ­ci

      @@ishkebabvery nice .. did the other chap delete his comments 😂

  • @SupraBdub
    @SupraBdub Pƙed 3 lety

    I've noticed some differences between Brittain and America, namely the"fuse/breaker boxes are metal here, also we generally have GFCI outlets where needed but no rcd protective breakers. And at most houses using a ground pole into the dirt instead of at gas line or whatever. And obvious that we have in wall flush outlets mostly, yours appear to be GFCI, or have a switch on them.

  • @liamjohnny335
    @liamjohnny335 Pƙed 3 lety

    Yr a sound fella... interesting and thorough

  • @londontrada
    @londontrada Pƙed 3 lety +1

    33:20 thats reverse polarity of the L & N, you can check and get the reading by reversing the leads on the tester (obs needs to be fixed)

  • @munafmufc01
    @munafmufc01 Pƙed rokem

    Your a legend Del brilliant advice

  • @e5Group
    @e5Group Pƙed 3 lety +1

    Delroy. 👏👌👍

  • @Cumbrianbushcraft
    @Cumbrianbushcraft Pƙed 3 lety +2

    On 2.5mm twin and earth the CPC resistance is 1.67 x the value of the r1 or rn reading. This is the ratio between 2.5mm and 1.5mm

  • @dsbelectricaldavidbetterid8448

    socket circuit code 3 would be 2 if the supply was used out side napit code brakers book is interesting read

  • @gazdkw82
    @gazdkw82 Pƙed 3 lety +1

    It should be noted that on RFC testing, stage 2 is r1+rn. I know in the real world this is not always done but when the young lad goes into assessments it will be expected. Also cpc is 1.67 times greater.

  • @Madman-ge2eb
    @Madman-ge2eb Pƙed 3 lety

    What’s wrong with a rcd spur and a bit of silicon in the holes đŸ€·â€â™‚ïž

  • @LAsparkTVWireTestLimited
    @LAsparkTVWireTestLimited Pƙed 3 lety +1

    I'm a bit puzzled cos you were testing for Zs on the pendant using one of those kewtech socket adaptors, but you were doing the test between switched live therefore and surely neutral on the other side? Those things can't tell you if it's earthed or not, you have to surely take off the light fitting to find the cpc? If not, I am missing something crucial cos it's the reason I hate doing lighting circuits, I'm always taking all them off and they often break or come off the ceiling if they're stiff! Great video.

    • @vivalasexy
      @vivalasexy Pƙed 3 lety

      Lol I hate testing Zs on lighting circuits. Any time there's pendants I get excited. Or if they loop at the switch Im a happy man lol

    • @ef7480
      @ef7480 Pƙed rokem

      You have to croc clip the earth terminal in the fitting and use the kewtech with the L-N leads to get the Zs .

  • @giovannidipari7412
    @giovannidipari7412 Pƙed 3 lety +1

    i don't see the problem in using a 1.5 cable fused with a 5amp

  • @iangirdler2773
    @iangirdler2773 Pƙed 3 lety

    I'm old school like yourself got my jib approved but didn't do my testing course wish I had love fault finding like the way you explain to the lad I'm sure I've met you somewhere

  • @rowles13
    @rowles13 Pƙed 3 lety +4

    Get the napit codebreaker book.🙌

    • @09weenic
      @09weenic Pƙed 3 lety +1

      Good shout - just got mine last week 👍

    • @aptsys
      @aptsys Pƙed 3 lety

      The Electrical Safety First Best Practice guide is more accurate and approved by most bodies. There's a lot of errors in Codebreakers which the author has admitted which mean many installations are incorrectly getting unsatisfactory results from someone who can only follow a book and not understand regulations.

    • @rowles13
      @rowles13 Pƙed 3 lety

      @@aptsysits just a guide!!!your interpretation of a c2 code could be different to mine đŸ€·â€â™‚ïž

  • @dZxMisq
    @dZxMisq Pƙed 3 lety +1

    Are you taking on any other trainees pal?

  • @bbr9707
    @bbr9707 Pƙed 3 lety

    Kitchen fitters!

  • @arniewheeler4673
    @arniewheeler4673 Pƙed 3 lety

    typical kitchen fitter

  • @nextbigstar8748
    @nextbigstar8748 Pƙed 3 lety +2

    I think its dangerous and bad craftsmanship because in the event you cut all power to lighting and open that up and trust the fuseboard and dont re-test at the switch itself youll get electrocuted

    • @Ragnar8504
      @Ragnar8504 Pƙed 3 lety +3

      That's more of a labelling issue, isn't it? Besides, you should always measure before you touch anything, at least in theory!

    • @ef7480
      @ef7480 Pƙed rokem

      You must surely mean 'workmanship'?

  • @foxxmulder7524
    @foxxmulder7524 Pƙed 3 lety

    you are 100 percent better instructor than Raymond webber.

  • @carljamess5497
    @carljamess5497 Pƙed 2 lety

    You say that R1+R2 should be lower than ze I find most of my r1r2 readings are always higher than ze.

    • @ef7480
      @ef7480 Pƙed rokem

      'big' r1+r2 or 'little' r1+r2? (R1+R2) + Ze = Zs