Size of plinth beam for residential buildings upto G+3 storey | Reinforcement details | Civil tutor

Sdílet
Vložit
  • čas přidán 29. 08. 2024
  • Download our android app for job oriented courses
    clpsheldon.pag... In this tutorial i have discussed briefly about the size of plinth beam for residential buildings upto G+3 storey and also the reinforcement details.
    2nd channel 👇🏻
    / civiltutorofficial
    Quantity surveying compiled PDFs 👇🏻👇🏻
    store.civiltuto...
    SFD & BMD PDF
    store.civiltuto...
    As we know, Plinth level is the level which lies at the end of the substructure and at the beginning of superstructure. The beam which is provided at the plinth level is known as plinth beam. This is the first beam constructed after the completion of foundation.
    Plinth beams play an important role in a building structure. These provide a connection between the columns and hence prevent them from buckling. They prevent the extension or propagation of cracks from the foundation into the walls, when the foundation suffers from settlement.
    Plinth beams distribute the load of superstructure over the foundation in an evenly manner. The size of plinth depends upon the lateral and axial loads acting on it. That's why it becomes necessary to provide the proper size of a plinth beam.
    In addition to that we must know what quantity of steel should be provided for a particular size to avoid any cracks in the walls of the structure caused by any settlement.
    In this lecture i have discussed what sizes of plinth beams should be provided in residential buildings upto G+3 storey as per thumb rule. I have also discussed about the details of steel reinforcement provided in each type of plinth beam.
    If we want to construct ground floor only....the minimum size of plinth beam should be taken as 9'' x 9'' or 225mmx0.225mm
    For this size of beam we should provide a minimum of 4 number of steel bars (2 at the top and 2 at the bottom) having a minimum dia 12mm plus tie bars/rings of size 8mm spaced at 150mm c/c.
    For G+1 storey, the size of the plinth beam should be taken as 9''x12'' or 225mmx300mm
    And we should provide a minimum of 5 number of steel bars... Out of which 2 number of bars of minimum dia 12mm at top, 2 no of 12mm bars at bottom and one extra bar of 10mm dia at the bottom plus tie bars/rings of size 8mm spaced at 150mm c/c
    For G+2 storey, the beam size should be taken similar to the G+1 storey building i.e, 9''x12'' or 225mmx300mm
    And we should provide 5 number of steel bars.... Out of which 2 number of 12mm bars at top and 3 number of 16mm bars at the bottom.... plus tie bars/rings of size 8mm spaced at 150mm c/c
    The same size should be taken for G+3 storey building i.e, 9''x12''
    And we should provide 2 number of 16mm bars at top, 2 number of 16mm bars at bottom and 2 extra bars of dia 12mm at the centre of the main bars
    Again the tie bars/rings of size 10mm spaced at 150mm c/c
    #quantitysurveying #civiltutor #ErMuyeenMubarak #materialquantity
    Quantity surveying Lec 1
    • Lec 1 | Estimation of ...
    Quantity surveying lec 2
    • Lec 2 | PCC Bed calcul...
    Quantity surveying lec 3
    • Lec 3 | Estimation of ...
    What is water cement ratio?
    (How to calculate the quantity of water in concrete) 👇🏻👇🏻👇🏻
    • Water cement ratio for...
    What is 1.54 in concrete?
    • What is 1.54 in concre...
    How to calculate volume of Cement bag?
    • How to calculate volum...
    Don't click here👇🏻😜
    surl.li/zdrn

Komentáře • 60

  • @kamalakantapradhan3117
    @kamalakantapradhan3117 Před rokem +5

    First time i saw a you tube vedio which is precise to the point no unnecessary boring lecture .
    I really appreciate. Pl let us know about G+4 residential building. &footing details.

  • @etnickstudiocirs7868
    @etnickstudiocirs7868 Před 2 lety +8

    We also need to specify the Code that governs for each country. It varies depending of the seismic condition. Like Most countries, 16mm is the minimum bar used for beams and columns.

  • @user-jo4sn1fg1z
    @user-jo4sn1fg1z Před 2 měsíci

    Really appreciate your explaination, may God bless u

  • @amar9981
    @amar9981 Před 2 lety +3

    very good description, i can easily learn from this type of animation with description.

  • @luimackjohnson302
    @luimackjohnson302 Před 2 lety +3

    Superb! Thank you for sharing this video. Please increase your audio volume by two fold. The video & illustration quality is very good. Greetings from Papua New Guinea.

  • @EdgerMwanga-zh2pj
    @EdgerMwanga-zh2pj Před rokem +1

    So good. Like to understand about columns sizes and spacing

  • @juricmariano1470
    @juricmariano1470 Před 3 lety +12

    Having discuss the size of flinth beam ! Kindly please discuss the TIE BEAMS in the same manner. TYVM

  • @sidza1
    @sidza1 Před 2 lety

    Mai basaan cxe gasakh kashur aasun .......By the way very nice information about Size of plinth beam for residential buildings

  • @sankalp8657
    @sankalp8657 Před 2 lety +1

    Love u sirji❣️u will definitely grow immensely

  • @kannankan827
    @kannankan827 Před 2 měsíci

    very good explanation......thank you so much...

  • @Mahesh-vi7mj
    @Mahesh-vi7mj Před 3 lety +1

    Tanku good explain May god bless you sir

  • @mjazz9017
    @mjazz9017 Před 2 lety +1

    I wish in Pakistan …people start to educate like u do…👍👍👍

  • @MagsasakangMarino
    @MagsasakangMarino Před 2 lety

    Very nice explanation even im not an eng'r,i really understand this

  • @abdulam1302
    @abdulam1302 Před 2 lety

    Hello Sir. Thank you So much
    To feed back My Rft knowledge.

  • @sunderrajp6920
    @sunderrajp6920 Před 2 lety +1

    Wonderfully explained.

  • @mdshamimakram5888
    @mdshamimakram5888 Před 2 lety +1

    Very important knowledge 💕 in civil engineering

  • @ms-kl7jk
    @ms-kl7jk Před 10 měsíci +1

    Thankyou

  • @thekapilbhagatvlogs3429
    @thekapilbhagatvlogs3429 Před 2 lety +1

    Sir I want to ask you. One more thing important is span of column to column... If the span is more than 15ft there is a need of 9"*15" Beam.. And minimum 16mm 3 bars at the bottom and 2 bars at top

    • @naidnI007
      @naidnI007 Před 2 lety

      Long span recommendable for Commercial building.. for domestic purpose Short span with 4*12mm rods more than enough since there wont be extra live load at all time.

    • @sridharsahoo489
      @sridharsahoo489 Před 2 měsíci

      sir maximum span plz

  • @balajistores7255
    @balajistores7255 Před 4 měsíci

    Can u pls suggest what type of steps we should taken For 40 ft width pillar to pillar ..

  • @MrKishorebabukotha
    @MrKishorebabukotha Před 2 lety +4

    Please provide the estimation for G+3 building end-to-end steel requirement with sizes under 185 SqYards with 12 pillers each and 1377 sft

  • @rajdeepnath7939
    @rajdeepnath7939 Před 2 lety

    Tie beam is for tying the columns so that they dont go for Long column. At footing level it is called strap Beam. Please explain if I am false.

  • @ajaychunduru1
    @ajaychunduru1 Před 2 lety +1

    Hello sir u told about beams but did not said about pillars plz say about pillars and Pillar span

  • @vijayyadavs
    @vijayyadavs Před rokem

    I have an existing G+1. I am renovating the 24 year old building which is wall to wall construction without pillars. In the ground floor, I want to break the center wall and give support using 2 C framr making a box type frame vertically support and 1 I frame Horizontal. I planned to construct G+2. Can I use 8 inch width I frame or H frame 6mm thickness for G + 2 support ? What type of support should I give vertically and Horizontally?

  • @sv3830
    @sv3830 Před rokem

    Good information

  • @michael1254
    @michael1254 Před 2 lety

    Thanks for this

  • @hogartoleranciaarmoniaamor2765

    because the upper columns are larger than the ground column. should , is the oppositte

  • @sreejithsr775
    @sreejithsr775 Před 2 lety

    G+3 building
    16 mm steel in bottom
    12mm in top
    0ne 16mm extra bent bar
    Vizag steel
    Plinth beam construction was, completed
    Is there any problem in this method

  • @sudhirbhadarge6282
    @sudhirbhadarge6282 Před rokem

    What kind of foundation required, if there's black soil up to 25ft deep

  • @narenrai536
    @narenrai536 Před 2 lety

    Thanks 🙏🙏🙏🙏🙏

  • @erkrishnadas08
    @erkrishnadas08 Před 5 měsíci

    Sir for G+3 building can my column size 15×8 column

  • @kalidhamza1278
    @kalidhamza1278 Před rokem

    Thanks so much i like to have this pdf please

  • @richardgalan5977
    @richardgalan5977 Před 2 lety

    Sir how about 4pcs. Steel rod 16mm and 12mm for ring column possible for G+2 storey

  • @beautyofbengal2907
    @beautyofbengal2907 Před 2 lety

    Residential house Build up area 950 sq feet. Total no of columns 12. Can I use 10"×10" coloumn and beam with 4 nos 16 mm TMT in each?

  • @keshabsahu9667
    @keshabsahu9667 Před 2 lety +1

    Sir what should be the minimum height of neck column for 3 storey building

  • @saeedqamar1996
    @saeedqamar1996 Před 2 lety

    Nice information

  • @nareshvasava6797
    @nareshvasava6797 Před 2 lety

    Fantastic

  • @nizamali7027
    @nizamali7027 Před 9 měsíci

    Good

  • @B_I_K_I
    @B_I_K_I Před rokem

    Tell about roof beam like this video urgent need

  • @megadesignarch4023
    @megadesignarch4023 Před 2 lety

    Wonderful

  • @koteswararaoav5029
    @koteswararaoav5029 Před 2 lety

    Thank you sir

  • @rabinpaul4638
    @rabinpaul4638 Před rokem

    9" x 12" size is steel or steel + concrete ?

  • @Satishkumar-ne4ug
    @Satishkumar-ne4ug Před rokem

    8mm stitrups are sufficient for g+3, g+4 ...

  • @anjomerpandesarao3053
    @anjomerpandesarao3053 Před 2 lety

    Is plinth beam the same in 2nd and 3rd floor beam??

  • @rupalpatel154
    @rupalpatel154 Před 2 lety

    Please give me steel details for one story building two story building three story and four story building footing net plinth beam upper beams and columns.

  • @julsvlogtv1991
    @julsvlogtv1991 Před 2 lety

    thanks..for sharring.

  • @skhero9103
    @skhero9103 Před 2 lety

    What is the span between column

  • @vnath3676
    @vnath3676 Před 3 lety +1

    👌👏👍

  • @ajaychunduru1
    @ajaychunduru1 Před 2 lety

    Didn't find any link to download pdf were is it???

  • @kevinexit12
    @kevinexit12 Před 2 lety

    what about G+5?

  • @sandysinha5087
    @sandysinha5087 Před 6 měsíci

    करपया हिन्दी मे भी समझाए

  • @khaledmostafa5333
    @khaledmostafa5333 Před rokem

    6m !