For 19ft Span - Size of Footing , Column and Beam Reinforcement Details

Sdílet
Vložit
  • čas přidán 21. 06. 2021

Komentáře • 80

  • @truedecors5941
    @truedecors5941 Před 2 lety +1

    Super explanation direct to core content

  • @nsubugadeo7256
    @nsubugadeo7256 Před 11 měsíci +2

    Nice lecturer🎉

  • @fasterfaster5960
    @fasterfaster5960 Před 3 lety

    Baraka lahou fikkk

  • @bollusrinivas
    @bollusrinivas Před 3 lety +4

    Column size 9/15 with 6 Rods(16mm 4bars and 12mm 2bars with 8mm rings @6inch) and distance between two columns is 15.8feet. two rooms, each 12feet/15.8feet. Footing 6.5feet depth width 4x4, with 1feet 40mm and 2.5feet 20mm. Is this good for g+2 residential building?

  • @identidem
    @identidem Před 2 lety

    Thanks a lot o was looking for this for a long time but didn't find much info.
    The span I have is 22 ft.
    Columns 9*14inches, 4 bars16mm and 2 bars 12 mm door/lintel beam is 6inches and the roof beam is 12 inches deep 16mm bars. Will it be sufficient?

  • @engrraufkhan9876
    @engrraufkhan9876 Před 3 lety +7

    Nice lecture,sir Explain Difference between Tie beam and plinth beam

  • @anilshukla8075
    @anilshukla8075 Před 2 lety +1

    Excellent knowledge

  • @venu511
    @venu511 Před 2 lety +1

    Good video sir..more information 👌👌👌👌

  • @pradeepSuriyabandara
    @pradeepSuriyabandara Před rokem

    Thanks for the lesson what about if this G + 2 story with 5 ton of load

  • @KusaasiraNoah7421
    @KusaasiraNoah7421 Před 2 lety

    can you use 16mm diameter bars in columns and 20mm in beams?

  • @ameehasa5504
    @ameehasa5504 Před 3 lety

    How many crank bar we should use? I hope if u have video for framing on all type of soil

  • @syedabdulquddus3469
    @syedabdulquddus3469 Před 2 lety

    supper sir, Thank you very much

  • @dreamer69223
    @dreamer69223 Před 2 lety

    Is 12mm 5 bars, 16 mm 1 bar enough For 14 feet beam ( top 3 - 12mm, bottom 2 - 12mm and 1- 16 mm)??

  • @ph6263
    @ph6263 Před 3 lety +1

    Sir My newly constructed house have one of the beam of length of 5.2 m (16.5 ft) and one secondary beam is tested on it. It is 230×300mm but we used 4 no of steel bars of 16 mm at bottom and 2 nos of 16 mm + 1 no of 12 mm at top.
    So ll it sustain to that amount of load for longer period or developed crack???
    As I see many engineers recommend more than 450 mm deep beam.

  • @faruqahmedbusiness1105
    @faruqahmedbusiness1105 Před 3 lety +1

    Will you show the analysis. Formula or thumb rule for column and footing design like beam depth formula l/20 for depth.

  • @kennethwhite5158
    @kennethwhite5158 Před 2 lety

    Sir, If we have four steel rods on the bottom of the beam and three steel rods in the column to tie off to how is it possible to tie the two middle rods in the beam to one middle rod in the column? I'm confused.

  • @javedalibukhari2326
    @javedalibukhari2326 Před 28 dny

    1 thing missed 😊
    If the size of crank bar 19 fit what is the size of carnk position. What is the is the distribution size..
    It is important as well.

  • @murthyau6620
    @murthyau6620 Před 3 lety +3

    Can we know from you, the load bearing of our existing Residential structure, to go for further floors, at professional consultation. Then how to communicate, please. Regards.

  • @amols9634
    @amols9634 Před 3 lety

    L/20 for 19 feet span 285mm depth so safer side you have to take 230x 380

  • @mohammadmuslim5694
    @mohammadmuslim5694 Před 2 lety +1

    Good lecture

  • @phyohtetkoko929
    @phyohtetkoko929 Před 2 lety

    Thanks For Teaching Sir

  • @byrappakaramaradi4070
    @byrappakaramaradi4070 Před 2 lety

    What should be the height of building?

  • @hemantasingh8606
    @hemantasingh8606 Před 3 lety +2

    6 nos of 16mm in beam (10X12) for 20 feet span.column (12x12) 4 nos 16mm &4 nos 12mm for single room .can we build g+2?

    • @kswvidioyoutube8816
      @kswvidioyoutube8816 Před 3 lety

      It's possible even I'm doing my own house with four 16 mm andtwo 12 mm in one biller size is 8/10

  • @akojuravisankar3492
    @akojuravisankar3492 Před 2 lety

    Thank you for giving good information about construction building.

  • @defersonlyngdohmawlong708

    G 1 G2 G3 means what? Does it mean 1floor 2floor

  • @Mithushahome
    @Mithushahome Před 3 lety

    Super bro

  • @paonamdineshmangang6179

    Sir is it OK to put 4 Steel rod of 16mm on top and 4 on bottom of 17.5 feet long beam

  • @moamar7585
    @moamar7585 Před 2 lety

    what is the thickness of footings?

  • @waluohopaulo2116
    @waluohopaulo2116 Před 3 lety

    Well understood

  • @namahshivay8978
    @namahshivay8978 Před rokem

    Thanks 👍❣️

  • @khan52310
    @khan52310 Před 2 lety

    If I have 24 feet span and other side is 26 feet span for G plus 1 story home only, please reply

  • @UmeshSahu-di2ee
    @UmeshSahu-di2ee Před 2 lety

    Wow bhai....

  • @sridharsahoo489
    @sridharsahoo489 Před 3 lety

    Sir u could not say top reiforcement which mm bar used in this video

  • @kaungsettlinn1179
    @kaungsettlinn1179 Před 4 měsíci

    ACI code(Beam is. span× 0.75=beam depth)

  • @manjunathbc3655
    @manjunathbc3655 Před rokem

    What should be size of beam and column and size of steel which is 7 meters and roof size and steel size G+3

  • @ariezaziziacahlebih2637
    @ariezaziziacahlebih2637 Před 3 lety +2

    Salam sir, does this can apply to 21 ft span?

  • @intkhabahmad453
    @intkhabahmad453 Před rokem

    Steel volume should be 1-2% of RCC volume for beam. Calculate it

  • @salimmahmud1614
    @salimmahmud1614 Před 2 lety

    Maa shah Allah

  • @premjitchakpram4201
    @premjitchakpram4201 Před 3 lety +1

    How about if we made column size 12x12 for G+2 residential house with steel rod of four 16mm and four 12mm?

  • @ayaan5633
    @ayaan5633 Před 3 lety

    Can you do your future video measurements in feet and inches.?

  • @ningthoujamnewtonmeitei5137

    Sir can it apply in normal residential building

  • @muhammadtahirmushtaq6300

    good mashallah

  • @aemisection4460
    @aemisection4460 Před 2 lety

    please post a video for culvert reinforcement details and designs

  • @lakshmanang8316
    @lakshmanang8316 Před 3 lety +1

    Need plinth beam design

  • @kswvidioyoutube8816
    @kswvidioyoutube8816 Před 3 lety

    Very nice explaination but not for the poor peaple it's too much and it will be very expensive less size column beam can biuld G+2

  • @muruganmuthusamy9976
    @muruganmuthusamy9976 Před 3 lety

    Fine

  • @chatpatgamingyt2707
    @chatpatgamingyt2707 Před 2 lety +1

    What will be the size of footing for same building if soil bearing capacity is 70kn/m2?

    • @SandeepKumar-eg1kw
      @SandeepKumar-eg1kw Před rokem

      It is good decision to choose deep foundation than shallow foundation if you cam to know soil is till 70kn of bearing

  • @nyantehemmanuel7089
    @nyantehemmanuel7089 Před 9 měsíci

    maximum span between columns

  • @engrijazali282
    @engrijazali282 Před rokem

    if the span btween 2 column is 16ft...and the building is G+1+2 than explain size of column and beam...

  • @lakshmanang8316
    @lakshmanang8316 Před 3 lety

    I have one doubt ,
    In your previous video you say As per Indian standard min depth of beam is d/16 = 19/16= 1.2 ft but you say now 1 ft is enough . how !?

  • @himangshupatra5000
    @himangshupatra5000 Před 3 lety +1

    SIR I HAVE 16 feet span G+1.stroy, i have provide beam ( 9 inch *12 inch ) , with 16 mm 2 bar, and 12 mm 1 bar at bottom, and 2 bar of 12 mm at top with 8mm stirrups @150mm c/c spacing, is it safe?? Also column size -(9"*15")

    • @ayaan5633
      @ayaan5633 Před 3 lety

      absolutely save for G+1

    • @trishan2739
      @trishan2739 Před 3 lety

      Can you explain that what is column and beam size with how many steel used with size
      Also length and width distance of each column

  • @izharulhaq8435
    @izharulhaq8435 Před 3 měsíci

    And calculate the no. Of beams for 40 by 16 feet

  • @musahhamid5461
    @musahhamid5461 Před 2 lety

    Pls I need picture of G+1 and G+2 story building

  • @ramakantapradhan7932
    @ramakantapradhan7932 Před 2 lety

    If column to column clear span 19', i want provide 6 nos 12mm bar in column and in beam 16mm 4nos bar, any problem plz solve it

  • @awishhamza6368
    @awishhamza6368 Před 7 měsíci

    12x9'' beam isn't safe for 19-20 feet span in beam column structure. do stress analysis

  • @logisticsh.n.a.a4136
    @logisticsh.n.a.a4136 Před 3 lety

    Do pakistan and india have the same engineering principles for rcc construction .

    • @MehrbanRana
      @MehrbanRana Před 3 lety +1

      Dear All over the world is same principles.
      Even here in GCC countries are same principles.

    • @logisticsh.n.a.a4136
      @logisticsh.n.a.a4136 Před 3 lety

      @@MehrbanRana thanks .

  • @izharulhaq8435
    @izharulhaq8435 Před 3 měsíci

    No. Of beams used for 40 by 16 feet

  • @palashmatubber8496
    @palashmatubber8496 Před 2 lety

    I love u sar

  • @izharulhaq8435
    @izharulhaq8435 Před 3 měsíci

    Please answer my question

  • @DeepakKumar-oo9si
    @DeepakKumar-oo9si Před 2 lety

    18fit distance mi kon sa colum lgta hi

  • @nawalshrivastav6032
    @nawalshrivastav6032 Před rokem

    Please hindi Language used.

  • @muhammadafzaal8670
    @muhammadafzaal8670 Před 3 lety

    Agr urdu mai lecture daitai to aor acha hota......

  • @shanjaiks7583
    @shanjaiks7583 Před 2 lety

    We are watching a religious programe . Inshallah

  • @intkhabahmad453
    @intkhabahmad453 Před rokem

    Your beam steel is not correct for 19 ft span... Moreover depth of beam is also very less for 19 ft... It should be minimum 19 ft... Rest of the calculation and suggestions are well.

  • @muzammilkhan3054
    @muzammilkhan3054 Před 2 lety

    Abhe main br 16 mm aygi

  • @idriveridesharing6493
    @idriveridesharing6493 Před 2 lety

    It's all confusing

  • @252adeshpatade3
    @252adeshpatade3 Před 2 lety

    Sir for 3 storey house
    6 no 12mm bars are sufficient or not
    Column size 9 * 15 "
    Please guide

  • @faritherwandy2126
    @faritherwandy2126 Před 3 lety

    Not economical.