Video není dostupné.
Omlouváme se.

Simply Supported Beam Reinforcement || 3D Beam Animation ||| RCC Structure

Sdílet
Vložit
  • čas přidán 1. 06. 2023
  • A Simply Supported Beam Reinforcement is beam which is supported at its both ends.Typical practical applications of simply supported beams includes bridges, beams in buildings, and beds of machine tools.
    Subscribe the channel for more videos
    / @druk-engineer
    #simplysupportedbeam
    #beam
    #beamanimation
    #3danimation
    #column
    #columnanimation
    #columnconstruction
    #buildingdesign

Komentáře • 25

  • @faisalfulad1874
    @faisalfulad1874 Před 4 dny

    Liked❤

  • @goallegend2k23
    @goallegend2k23 Před rokem +1

    Great. Keep it up

  • @manoj46507
    @manoj46507 Před měsícem

    Awesome

  • @harrinsonjavieraragonlanza6713

    Verygood

  • @rajveermittru1909
    @rajveermittru1909 Před rokem +2

    Very good brother. Keep it up..

  • @abdurrahim3605
    @abdurrahim3605 Před rokem +1

    Thanks a lot

  • @visano.
    @visano. Před 6 měsíci +1

    Is'nt that fixed beam? If not whats the main key difference

  • @jperianroshan4936
    @jperianroshan4936 Před rokem +6

    If the beam is simply supported, then why did you provide the extra bar at support?
    Simply supported beam has the maximum moment at middle and no moment at support.

    • @Gary-pogi
      @Gary-pogi Před 9 měsíci

      Negative bending moment at support.

    • @jperianroshan4936
      @jperianroshan4936 Před 9 měsíci +1

      @@Gary-pogi simply supported beam has not negative bending moment.

    • @skillhnter1303
      @skillhnter1303 Před 4 měsíci

      in this animation concrete poured on both ends with columns so its fixed beam. Title is wrong@@jperianroshan4936

  • @thealbert6s
    @thealbert6s Před rokem +1

    Bro, may I know what animation software did you use? Thanks.

  • @aieedabood6295
    @aieedabood6295 Před 8 měsíci

    Can i know which animation software you use?

  • @harrinsonjavieraragonlanza6713
    @harrinsonjavieraragonlanza6713 Před 2 měsíci +1

    Hay medidas estándares para altura de un segundo piso

  • @user-qy1zq9vf6b
    @user-qy1zq9vf6b Před 10 měsíci +1

    I wish if you provided us with what code you had used.

    • @drukengineer
      @drukengineer  Před 10 měsíci +1

      We use Indian Standard Codes (IS Codes), IS 456:2000 for design of Plain and Reinforced Concrete

  • @Gary-pogi
    @Gary-pogi Před 9 měsíci

    Drunk Engineer, no extra bar in tension zone?

  • @user-oz7zv3bc4u
    @user-oz7zv3bc4u Před rokem +1

    Varför inga sjuvningsjärn?

  • @skillhnter1303
    @skillhnter1303 Před 4 měsíci +1

    its a fixed beam

  • @taemoorhassan486
    @taemoorhassan486 Před 9 měsíci +1

    How you inserted the column ties at 1:11 ? It is not practical.

    • @drukengineer
      @drukengineer  Před 9 měsíci +2

      There are two different ties , a normal and a confining ties
      I have show in below link u can watch there
      czcams.com/video/IDpP6sXQFCE/video.htmlsi=SqSAcsEc7hkgIzvY

    • @taemoorhassan486
      @taemoorhassan486 Před 9 měsíci +1

      Yes. But column ties would have to be inserted before binding beam steel. Otherwise ties won't pass down as shown.

    • @drukengineer
      @drukengineer  Před 9 měsíci +2

      Oh yes you are right thankyou for information. I have done that to increase clarity of beam steel at the end (joint).

    • @SaurabhKumar-kr2rs
      @SaurabhKumar-kr2rs Před měsícem

      @@drukengineer animation software name

  • @user-oz7zv3bc4u
    @user-oz7zv3bc4u Před rokem +1

    Varför inga sjuvningsjärn?