How to fix a radiator that`s been bled but still not working.

Sdílet
Vložit
  • čas přidán 28. 10. 2012
  • If you have already bled your radiator and find it is still not working then here are some simple things to try. Please note that if you have a really old heating system that has no inhibitor in the system that you may well have to drain the complete system flush through with a flushing agent and then refill with an inhibitor.Also if your pump is running down you may well need to renew it, I have another video on how to do that / qeoywlbb
    Got your own plumbing or heating problem? Ask Al at: www.dereton33.com
    Saved you money on a plumber? Want to donate? www.dereton33.com/page118.html The link is there thanks, Al.
    Not the video you were looking for? Save further searching. We have over 150 plumbing/heating videos that you really can do yourself! There is also an ask `AL tab` tab on our website. www.dereton33.co.uk
  • Jak na to + styl

Komentáře • 620

  • @davidrobertson9768
    @davidrobertson9768 Před 4 lety

    As the other reviewers have said this is a highly recommended video for sorting out a problem radiator. Your video on balancing is also very useful.

  • @rockyhudson
    @rockyhudson Před 5 lety +3

    Your advice was spot on! We'd had new, larger and extra radiators installed recently during a refurbishment. I turned all the radiators off, then on 1/4 of a turn at the valve (rather than the temperature valve) and opened the cold radiator to full. Turned the heating on and now the radiator is red hot, as are they ALL! Thanks again.

  • @helenmclaughlin1334
    @helenmclaughlin1334 Před 7 lety +7

    Thank you so much for taking the time to make these videos. You helped me to successfully replace my cistern pump earlier this year and you've just mended my radiators after a week of being freezing cold and sick with worry about there being a huge, expensive problem with the central heating! Thank you so much and all the very best :) x

    • @dereton33
      @dereton33  Před 7 lety

      No problem Helen. Glad you sorted it.

    • @jameznm
      @jameznm Před rokem

      fair play for having a go.

  • @Midzark
    @Midzark Před 7 lety +4

    Fantastic!!! I tried everything before coming across your video!! Now the rad is super hot and I've opened the rest half a turn and it's still beaming with heat!!! Thank You So MUCH!!!

    • @dereton33
      @dereton33  Před 7 lety +2

      No problem.

    • @julie-annhughes563
      @julie-annhughes563 Před 4 lety

      My problem is the other way around lol my downstairs radiators are boiling but all upstairs aren’t working I tried turning off the downstairs radiators to force heat to upstairs but it didn’t work. The heating system is only a few months old gas

  • @holdenmilner
    @holdenmilner Před 3 lety

    Brilliant. You saved me. I tried everything after taking my rad off the wall for decorating. Turning all the radiators off made it come back to life. All working now. Thank you

  • @kuljindersingh701
    @kuljindersingh701 Před 4 lety

    Dereton comes to the rescue as always, after a extension the new radiator was struggling to keep warm followed this advice and it has worked great. Thanks for your video. I always watch your videos. Keep up the good work.

  • @ch1r2ne
    @ch1r2ne Před 3 lety

    IT WORKED! Balancing the boiler/radiator actually worked and now I can sit in my new loft room without a cold nose and hands! Cannot thank you enough! My plumber had no idea how to solve the problem and I did it with your help.

  • @Blasterman124
    @Blasterman124 Před 3 lety +1

    Thank you. Been struggling with this problem, had plumbers in and electricians thinking it was a electric fault. Hundreds could of been save if I seen this first. Good luck and thanks again

  • @cantiryakioglu984
    @cantiryakioglu984 Před 8 lety +10

    Thank you for this - the third way solved our problem!

  • @paulmaxwell7788
    @paulmaxwell7788 Před 5 lety

    Just tried this and it worked a treat to get heat back into my kids bedroom after getting a new radiator installed in the downstairs bathroom,thank you very much for making this video to help others.you my friend are a star👍

  • @madirish88
    @madirish88 Před 8 lety +18

    Thank you so much for this! I had given up on this and had 2 very cold rooms literally for years! i feel like a right eejit! Wish I could buy you beer!

    • @dereton33
      @dereton33  Před 8 lety +5

      +madirish88 Have a donate button on my website, then I will drink to your good health.

  • @schalkburger3028
    @schalkburger3028 Před 8 lety +2

    Fantastic! I did as you advised and the radiator is back to normal. Thank you!

  • @timcollins4453
    @timcollins4453 Před 5 lety +1

    This is why I love CZcams! Amazing. This fixed my central heating problems.

    • @dereton33
      @dereton33  Před 5 lety

      It`s not U-tube, it is us guys prepared to give our time and knowledge to help out.

  • @helenmansfield637
    @helenmansfield637 Před 5 lety

    Thank you so much it has worked brilliantly, we have spent many an hour trying to figure out why the radiator wasn’t working properly and your advice has saved many a headache.

  • @Ghostsandbutterflys
    @Ghostsandbutterflys Před 3 lety

    Removed an old radiator and replaced with new one & moved it to opposite side of room - had to extend pipework by 4 metres to new position. Refilled system and bled all radiators. New radiator clold / luke warm and would not heat up. Was about to call plumber in but followed your instructions instead. It WORKED PERFECTLY. All radiators are now balanced and the new radiator in lounge is hot and cosy .... Thank you for posting this video ... saved me a lot of hassle & expense ..... SUBSCRIBED 👍👍👍

  • @duster.
    @duster. Před 7 lety

    Brilliant, thank you so much. The rad that was moved was just barely warm - you're a star. The balancing trick did it.

  • @l0ner1der
    @l0ner1der Před 4 lety

    We’ve had lots of plumbing done recently, just added the last rad and it wouldn’t heat up along with one other, the rest were roasting and I’d bled them all. Tried turning the others off as you suggested and hey presto they’re red hot now. Thank you and happy Christmas!!

  • @richmondclan
    @richmondclan Před 9 lety +1

    Thank you, after 2 radiators in our house went cold after some thermostats were fitted in our lounge we couldn't work out what had happened. It must have become unbalanced as you explained as we've just turned all the other rads off and these 2 are now working. Thanks for the tip!

  • @sohobee3438
    @sohobee3438 Před 5 lety

    Just sorted my problem with your help. It was stressing me out . Now a happy bunny. I raise my glass to you . Many thanks for your explanation.

  • @timwebb21
    @timwebb21 Před 5 lety

    Brilliant, had a non working radiator and by following your advice it came back on. Much appreciated.

  • @cecilrowley7704
    @cecilrowley7704 Před 8 lety

    WELL DONE SIR WAS EXPECTING VISITOR AND RADIATOR IN ROOM NOT WORKING.
    DID WHAT YOU ADVISED AND IT WORKED. BRAVO.

  • @STUART9603
    @STUART9603 Před 9 lety

    What a great bit of advice, worked a treat the balancing bit!!
    Thank you!!

  • @rawdany
    @rawdany Před 2 lety +6

    Job fixed ! Great video buddy very easy to understand and straight to the point

  • @richardmabe4186
    @richardmabe4186 Před 6 měsíci +1

    Good advice. I had a cold radiator on my landing, it's been a problem for years. I turned the heating on then went round shutting off each radiator. As I shut off the last radiator before the cold one there was the sound of air moving and the cold radiator started to get hot. It still gets hot a year since the treatment. Thanks for your help.

  • @skiguns4ever
    @skiguns4ever Před 9 lety +1

    Thank you - this worked for me, excellent clear and well explained advice.

  • @deputyvanhalen6386
    @deputyvanhalen6386 Před 5 lety

    Great video again. What can help the flow of clean water sround ghe sydtem is adding the inhibitir thats in one of your videos ALSO having a filter fitted.
    Sometimes you got to get a new boiler as the pump has gone, with other things likely to go and its 10 years old etc.

  • @shaistashirazi1235
    @shaistashirazi1235 Před 3 lety +1

    Very clear information. The balancing steps brought my dead hallway radiator back to life. Thank you for your video..

  • @wezboyes
    @wezboyes Před 8 měsíci

    Great video. Was confused after bleeding the radiators and still no fix to the problem. Followed this and rebalanced the system, and it's working great now! Thanks very much!!!

  • @MKPSG12
    @MKPSG12 Před 6 lety

    Thanks for the video, I got a new expansion tank fitted and the system must’ve imbalanced. Been chasing the plumber for weeks to come back and sort the radiator but done it myself with your help, thanks again!

  • @iandarby3639
    @iandarby3639 Před 4 lety

    Brilliant advice. Got all my radiators going and no need to pay a plumber. Quids in. Thank you very much

  • @rayhindle642
    @rayhindle642 Před 8 lety +3

    Thank you for freely giving away knowledge that has probably taken you years to acquire, I have now subscribed to your channel, I hope you yourself get some benefit from these video's........
    Thanks again Ray H.

    • @dereton33
      @dereton33  Před 8 lety +2

      +Ray Hindle Thanks Ray, I really love to give my years of knowledge freely to those that can use it.

  • @pontdain
    @pontdain Před 7 lety

    Wonderful. Worked a treat. Another video I watched (by someone else, I should add) didn't mention anything about balancing the rads, and I initially assumed my problem was therefore a dodgy TRV on the cold rad. Thanks very much.

    • @dereton33
      @dereton33  Před 7 lety

      No problem. Stick with my channel it is the best.

  • @freddyv7546
    @freddyv7546 Před 9 lety

    I recently bled all the radiators in my house and I couldn't figure out why there was one (1) radiator that wasn't getting hot. I followed the instructions you provided and fixed the problem. Thank you for sharing your knowledge. N.Y.

  • @ilyaasoow
    @ilyaasoow Před 7 lety

    you just saved me call-out charge as i only have boiler cover.
    thank you very much.
    keep up the good work.

  • @nicolaccio1972
    @nicolaccio1972 Před 9 lety +1

    Thank you very much for this excellent tutorial. I trust it applies if more than 1 radiator are not heating up (cold) properly in the same room. I applied your suggestion leaving open only the cold radiators on the same floor. It appears to be working. Thank you once again. Nicola

    • @dereton33
      @dereton33  Před 9 lety

      Nicola Saccà Pleased you sorted it Nicola.

  • @MatthewDay
    @MatthewDay Před 4 měsíci

    Thank you. Even after bleeding i had 1 cold rad. Shut all the valves off apart from this one as you suggested and the problem rad is now boiling hot! Thanks for the tips and sharing your knowledge.

  • @glcmcfc
    @glcmcfc Před 7 lety +1

    This guy is blinking good, Love your videos.... very helpful..... You are the ORACLE!!

    • @dereton33
      @dereton33  Před 7 lety

      Well, I don`t think I am that good, but thanks anyway. The Oracle humm.

  • @TheBlakej1
    @TheBlakej1 Před 9 lety

    My husband took the radiator out to desludge it and no progress. Found your video - and worked a treat. Thank you for a great video.

    • @dereton33
      @dereton33  Před 9 lety

      ***** No problem pleased you fixed it Ok. Al.

  • @wwtprez4594
    @wwtprez4594 Před 6 lety

    just when i thought id have to pay out some more money, i owe a thanks to this guy! Much appreciated

  • @humeiyoo
    @humeiyoo Před 8 lety

    Thank you. I moved to a new house n the heating in the lounge didn't work, tried bled all valves n been fiddling around with no luck. Tried ur method n switching off all upstairs radiators n only leave the lounge ones on. They all warm now. Thank you very much.

    • @dereton33
      @dereton33  Před 8 lety

      No problem, pleased you now have some heat. Al.

  • @leeogrady5433
    @leeogrady5433 Před 8 lety +2

    What a Guy....Awesome Geezer !!! You are a star !!!

  • @willkndy
    @willkndy Před 5 lety

    Thanks a lot this really helped me out. Had one radiator that wouldnt heat up at all, tried other ways of balancing the rads and had no luck, even had a plumber try balance them but didnt make any difference! Turning all the other rads off first worked really well! Love the channel keep up the good work 👍👍👍

  • @jon-paulmullin4139
    @jon-paulmullin4139 Před 9 lety +1

    Thanks for your video. Its so easy when you know how. You saved me a few bob.

  • @johncameron8356
    @johncameron8356 Před 5 lety

    Cheers. I had a new rad fitted and no heat. Just tried what you said and worked straight away. 👍👍👍

  • @manolis2501
    @manolis2501 Před rokem

    Your are right... 9/10 is that and it was that with mine too - so good to know there are people out there who know what they are talking about - Well Done and Thank You!

  • @highlander2377
    @highlander2377 Před rokem

    your a legend mate! tried everything else then came across your video, it worked straight away! thanks champ i owe you a beer!

    • @dereton33
      @dereton33  Před rokem +1

      No problem. PS it`s John Smiths.

  • @tomfewins5803
    @tomfewins5803 Před rokem

    Thank you , I too had given up on a couple of radiators after removing them and flushing, but by turning off all the radiators but the furtherest one, and working backwards as you explain, I have my closest radiator burning hot on an eighth of a turn open and my furthest open all the way and burning hot too! You have helped me no end ! Thank you

  • @DM43685
    @DM43685 Před 4 lety

    Thank you so much, you are a genius!!! Had to replace my 3 way valve, emptied, replaced, inhibited and the exact problem you mentioned happened once I refilled and reheated.. To make sure I had a good flow of pressure and water (when emptying) I initially opened both lock sheer and thermostatic valves. Your help by fully closing them upstairs and then slightly opening them, fixed the problem, and as a bonus I found the last RAD!!! which means I can drain from that in the future....THANKS AGAIN!!!

  • @behappee4212
    @behappee4212 Před 3 lety +1

    Watched this and solved in 15 minutes.What a star you are! Honest trades need more people like you.

    • @dereton33
      @dereton33  Před 3 lety +1

      Thank you for your kind comments.

  • @joewigfall8046
    @joewigfall8046 Před 9 lety

    Thanks for your help. I called a plumber, but he failed to show. After listening to your advise about balancing radiators, I set to work. System works well now, thank you

    • @dereton33
      @dereton33  Před 9 lety

      Joe wigfall Great!! Saved you some money!! Al

  • @marksmithard7801
    @marksmithard7801 Před 2 lety

    Thanks for this video. Looked at many utube videos on this issue and none fixed it. Tried bleeding, knew it wasn’t that, checking the thermostat valve and balancing it no joy. Your method of turning all rads off, half a turn back on each when the problem rad warmed up worked. Yes it’s only balancing but you explained it so clearly. I’d buy you a beer if you were in the pub. Cheers🍺🍺

    • @dereton33
      @dereton33  Před 2 lety +1

      Ha ha thanks Mark, a pint of tribute thanks.

  • @Melv245
    @Melv245 Před 8 lety

    Thank you. It worked!!! My system was unbalanced. Excellent advice. Thanks again.

  • @julie-annhughes563
    @julie-annhughes563 Před 4 lety

    Thank you , I watched a few videos on this problem no fix then I saw your video which was the only one that was the right method and worked now my two radiators are working 😃

  • @HH-green
    @HH-green Před 8 lety +1

    Thank you so much for your video. Your advice helped me save some money.

  • @simonjohnstone7405
    @simonjohnstone7405 Před 4 lety

    Mate,
    thank you very much for sharing this, you have just saved me a few bob calling out a plumber that I can bot afford.
    I owe you a pint mate.

  • @LeonSkerritt
    @LeonSkerritt Před 7 lety

    Great tip. Just saved me a whole lot of bother after getting a new boiler fitted. Thanks.

  • @jamestaylor9855
    @jamestaylor9855 Před 4 lety

    Legend! It worked. As soon as I turned the rest off it was hot within 1 minute. Thank you.

  • @dereton33
    @dereton33  Před 11 lety +1

    It`s ok it does not matter which side you shut down the effect will be the same.For info,the lockshield cap that fits on one of the valves when they were new was designed to be adjusted to balance the system then when the cap was reffited that radiator would be in balance with the rest of the radiators without stealing too much heat.
    Hope that makes sense,regards
    al.

  • @brianpope5243
    @brianpope5243 Před 6 lety

    Thanks for you're help, even the man from British Gas didn't solve why the radiators came on except the one in our living room, which is the most important, once again thanks & thanks to CZcams.

  • @Karl1969Peter
    @Karl1969Peter Před rokem

    Thanks for posting this.
    I had bled my radiators until it was just water.
    All radiators downstairs were cold.
    Looks like my system was unbalanced. I followed your advice and hey presto! Heat.

  • @TheKentoss
    @TheKentoss Před 6 lety

    Thank you very much for explaining so simply, thought I was going mad!! Great video, big help thank you

  • @mikecollins8094
    @mikecollins8094 Před 3 lety

    Your a legend thankyou , all radiators working again after balancing .Happy New year to you sir

  • @The_One_Called_Keith
    @The_One_Called_Keith Před 7 lety

    Thank you SO much, just turning them all off and then back on afterwards did the trick !! So happy and grateful

  • @Highlander1518
    @Highlander1518 Před 6 lety

    Had this issue today. All radiators fine with the exception of one in the kitchen. Bled the radiator slightly and then followed this video. The radiator is now steaming hot. Thanks!

  • @cianfurlong6336
    @cianfurlong6336 Před 3 lety

    Thank you a lot. This fixed the weird rad downstairs after 8 months of head-scratching. Great advice and vid!

  • @BubblyCreative
    @BubblyCreative Před 5 lety

    Just used this video to help me with my issue and worked. Fantastic! Thanks

  • @johnallen4468
    @johnallen4468 Před 9 lety +1

    Cheers for your advice it worked for me. Saved me a few quid on calling a plumber out too :) thankyou

  • @alanfinal30
    @alanfinal30 Před 2 lety

    Nice one , old council upstairs flat with 4 runs up into the loft and down ,when I took off a radiator for decorating it wouldn't get warm again ,did as you said and balancing the system worked.

  • @tudorbostan8973
    @tudorbostan8973 Před 5 lety +4

    You're a star! Amazing. Thank you for the advice.

  • @davidcoleman6032
    @davidcoleman6032 Před 2 lety

    Great video!You make a great instructor and turn alot of head scratching into a solution 👍many thanks!🙂❤

  • @breifne555
    @breifne555 Před 3 lety

    Thank you, thank you, Thank you...you solved my conundrum that the local plumber couldn't. 17 rads and the end one just wouldn't get hot. Done.

  • @mscrace
    @mscrace Před 5 lety

    Thank you for sharing this video, it certainly pointed me in the right direction! I had several radiators that were cold and bled fine. It turned out to be a sticky pin in the thermostatic valve (all of which were the same design(old)), I just took the valve control knob off and moved the pin in and out(a spot of WD40 might also help long-term). Toasty house!

  • @aerodrum
    @aerodrum Před 8 lety

    Wow man, it TOTALLY WORKED!!!!
    Thank you!!!

  • @neldadog
    @neldadog Před 11 lety +1

    Tried what you said, worked a treat! Thanks very much!

  • @JonGritton
    @JonGritton Před 9 lety

    Thanks for this - our bathroom radiator was stone cold and we were on the verge of calling a plumber. Watched this and solved it in a couple of minutes... turned out to be the balancing thing. Invaluable!

    • @dereton33
      @dereton33  Před 9 lety

      Jon Gritton No problem Jon . Al.

  • @EvagorasMandrides
    @EvagorasMandrides Před 9 lety +1

    Thank you... Perfect! Worked within seconds.

    • @dereton33
      @dereton33  Před 9 lety

      Evagoras Mandrides No problem. Al.

  • @CasualTimes
    @CasualTimes Před 6 měsíci

    Always a great help your videos, helped me a few times with various issues regarding heating systems. Cheers 🍻

  • @4TheRecord
    @4TheRecord Před 7 lety

    Will try this out tomorrow, the strange thing is we had a new radiator put in and it wasn't until a few weeks passed that the one closer to the boiler went cold.

  • @vinodgogna7846
    @vinodgogna7846 Před 4 lety +1

    Thanks. I Will try this. I have three rads in the loft two are working but one is not.

  • @DetailingandtheBeast
    @DetailingandtheBeast Před 2 lety

    Thank you so much! I have been struggling getting heat into our lounge for literally months.
    Twenty minutes and you have solved us a massive problem.
    All our lockshields were wide open.
    Now sorted and ALL radiators are hotter than they were.
    Again, thank you so much.

  • @seanmcardle4007
    @seanmcardle4007 Před 2 lety

    Balancing the rads worked a treat. Thank you v much.

  • @sarawhitticombe7362
    @sarawhitticombe7362 Před 8 lety +2

    Worked incredibly well and so easy! Thank you so much! We are now warm again. :)

  • @doriangriffiths6099
    @doriangriffiths6099 Před 5 lety

    Thank you for this. Sorted our problem out

  • @gatorsinthebayou
    @gatorsinthebayou Před 6 lety

    My living room radiator was ice cold, it was freaky when you said it would be the living room..!!
    Did as you said & you sir, are a legend!
    Everyone who watches these kinds of videos is extremely grateful, thanks a lot buddy, working perfect now 👍🏽

  • @johnydee6775
    @johnydee6775 Před rokem

    Thanks a lot it solved my issue. As you suggest I closed all radiators above and these down started working. Now will check the pump, if can increase the speed. I think - will be better if the pump work at higher speed.

  • @mdsoulsounds
    @mdsoulsounds Před 8 lety

    Thanks again for your video. It was very clear and made very good sense to work things out by the process of élimination.

  • @esox4809
    @esox4809 Před 9 lety

    Cheers mate
    Turned the heating on this morning first time this year 2 rads wouldn't work
    Followed your advice and problem sorted
    Thanks again ;-)

    • @dereton33
      @dereton33  Před 9 lety

      Kenny Powers No problem Kenny. Al.

  • @anthonyroberts6704
    @anthonyroberts6704 Před 6 lety

    After trying to bleed my downstairs radiators that always stayed half hot and half cold. Found this video via google and now my downstairs radiators are blistering hot. Genius!!!!

  • @tonyrook5489
    @tonyrook5489 Před 8 lety

    Top man! Sorted out my central heating system following this video thank you

  • @SuperChemist007
    @SuperChemist007 Před 8 lety +1

    thanks chap . new pump is firing them all up nicely

  • @adammcerlain3977
    @adammcerlain3977 Před 8 lety +1

    AWESOMEEE !! thank you , what happened me was i lowered some pipes in roof space with pushfit fittings all worked except 2 radiators which would`nt bleed, could`nt figure it out, this made sense to add pressure to the remaining 2 and fixed it in seconds BRILL !!! you are the man :)

  • @samanadam2442
    @samanadam2442 Před rokem

    You absolutely star thank you very much for the information I’ve seen so many videos no one explain as you did thanks again keep doing it

  • @Mygezzatv
    @Mygezzatv Před 8 lety

    Thank you and thank you for your quick response

  • @awesumbzr620
    @awesumbzr620 Před 3 lety

    Thanks mate... The air lock technique worked perfectly.

  • @malakai651
    @malakai651 Před 3 lety

    Thank you very much, what you say makes a lot of sense and helped me solve two problems. You are a star!

  • @lucylewendon578
    @lucylewendon578 Před 2 lety

    Thanks, your solution cured our bathroom towel rail that was not heating up.

  • @ammarhasan
    @ammarhasan Před 6 lety +1

    Thank you very much, this worked a charm :)

  • @seabhreach
    @seabhreach Před 8 lety +1

    Thanks, worked a treat!

  • @coolrocknroll
    @coolrocknroll Před 5 lety

    Worked perfectly, thank you! I now have a better understanding of how is distributed in the home. A question please . . is it a good idea to turn off the rads in rooms which are not occupied for long periods of time?

  • @dennybwoy
    @dennybwoy Před 2 lety

    You are the man!!!!! Just sorted my problem out … thank you 👍👍