How to bypass kent grand plus RO ballast

Sdílet
Vložit
  • čas přidán 10. 09. 2024
  • #kent #kentro #rowaterpurifier
    In previous video (Video link:- • how to reset filter ch... ) we saw how to reset electronic ballast of kent grand plus RO. But sometimes it fails to reset due to some defects in circuit board of electronic ballast. we can simply bypass this ballast by joining two jumpers at main connector.

Komentáře • 109

  • @anandnautiyal7122
    @anandnautiyal7122 Před měsícem

    Sir I am getting red light in the pcb and the output connectors for uv lamp have no voltage...what might be the issue?

    • @diyrepairs
      @diyrepairs  Před měsícem

      It supplies power to the UV lamp only when the green light on the PCB lights up. Usually the red light on the PCB flashes when the water storage tank is full. When the water level in the storage tank drops the water level sensor gives a signal to the PCB and then the PCB turns on, also do not check the voltage on the UV lamp connector, it can be dangerous.

  • @officialhonorupdates
    @officialhonorupdates Před 2 lety

    I have installed all filters new one so I have to flesh before use? And how much time i should flush them ? And

    • @diyrepairs
      @diyrepairs  Před 2 lety

      fill the tank once and then drain it.

  • @mayankkaushik1264
    @mayankkaushik1264 Před rokem

    Sir Please Reply...Technician Kent PCB me Problem bta rha hai .Power nhi aa rhi hai.After Some days RO apne aap on ho gya working Fine ,Just after 2-3 days again stop working .Kya problem ho skti hai?
    PCB bypass kerne per UV work krega ?
    PCB Coastly hai..Repair Cost ?

    • @diyrepairs
      @diyrepairs  Před rokem +1

      pcb me microcontroller laga hai wo kharab hone pe nahi banegi. ek fuse bhi hota hai. fuse check kar sakte hain. agar pcb me line nahi aa rahi hai to smps ko check karen wahan 24 volt aa rahi hai ya nahi. phir connector ko check karen kai baar connector me copper sulphate jama ho jata hai usko check karen aur agar hai to saaf kar len. pcb bypass karne par uv lamp nahi jalegi. pcb 1000 rupye me mil jata hai.

  • @Tradingview124
    @Tradingview124 Před 2 lety

    Sir my solenoid valve again failed....so I bypass the connection without solenoid valve....koi dikkat to ni h na

    • @diyrepairs
      @diyrepairs  Před 2 lety

      solenoid valve nahi lagane se paani machine nahi chalu rahne par bhi UF filter se water tank me jayegi aur paani leak kar sakta hai.

  • @itsdumpy
    @itsdumpy Před rokem

    can i use stabilizer for the long life of the choke?

    • @diyrepairs
      @diyrepairs  Před rokem

      The choke is powered by 24 volt SMPS. A good quality SMPS does not require a stabilizer.

  • @officialhonorupdates
    @officialhonorupdates Před 2 lety

    when removing filter water inlet pipe water comes out with pressure is it normal or my filter have some problem i have closed the water tap too still when trying to remove the water in pipe from filter. Water comes out with pressure?

    • @diyrepairs
      @diyrepairs  Před 2 lety

      There is some residual water in the filter that will come out when the pipe is removed. It's normal. But if the water is coming out with too much pressure then there is a possibility of the filter getting choked.

    • @officialhonorupdates
      @officialhonorupdates Před 2 lety

      @@diyrepairs i have checked all filters all are clear no blockages but water comes out with high pressure

    • @diyrepairs
      @diyrepairs  Před 2 lety

      @@officialhonorupdates don't worry its normal

  • @automobile._
    @automobile._ Před 2 lety +1

    Thank

  • @AMIT-ef3cm
    @AMIT-ef3cm Před 3 lety

    I have got a Kent Maxx system. I was getting continuous beep and the system was not working. I have changed the UV lamp but the beep is still coming. Tried to reset the ballast but the problem persists. Does it mean that the electronic ballast is defective?

    • @diyrepairs
      @diyrepairs  Před 3 lety

      The continuous beep sound is indicative of a filter change alarm, not a UV lamp. Yes, even after resetting it, beeps mean the ballast is defective. You can change the ballast or bypass it. Try one more time, press the reset button until the continuous beep sound stops.

  • @prasadkarlekar7856
    @prasadkarlekar7856 Před 4 lety

    You have not shown "UV" light connection in last bypass diagram. Without UV filter want to run the RO . ??? If i want to connect at wt voltage required to on UV light?

    • @diyrepairs
      @diyrepairs  Před 4 lety +1

      actually we are bypassing the ballast and UV lamp get power from ballast. if you want to glow UV lamp then you should have to replace the ballast.UV lamp require a choke to glow. Video link
      czcams.com/video/JOyO65tQK4o/video.html . Video link
      czcams.com/video/4HqjNFCnFRk/video.html

  • @officialhonorupdates
    @officialhonorupdates Před 2 lety

    Some wire from 220 to float switch is it safe or 24v should be used for float switch

    • @diyrepairs
      @diyrepairs  Před 2 lety

      24V is safe because at higher voltages such as 220V the contact point of the float switch can generate sparks and be damaged.

  • @JagatK_
    @JagatK_ Před 2 lety

    So, after doing this we won't need to change the entire set (which costs around Rs 5000) in every 12 months as written on them ?

    • @diyrepairs
      @diyrepairs  Před 2 lety +1

      yes, but change when TDS increases drastically

    • @JagatK_
      @JagatK_ Před 2 lety

      @@diyrepairs Thank you very much.

  • @officialhonorupdates
    @officialhonorupdates Před 2 lety

    I got a uf membrane it's weight is very less is it normal or that uf is not a good quality one

    • @diyrepairs
      @diyrepairs  Před 2 lety

      are you comparing the weight of two new UF membrane? if you comparing with old one then naturally the old one has more weight than new one because it has some water content.

    • @officialhonorupdates
      @officialhonorupdates Před 2 lety

      @@diyrepairs both empty

    • @diyrepairs
      @diyrepairs  Před 2 lety

      @@officialhonorupdates if both are new then use heavier one.

  • @shubhamkhandelwal858
    @shubhamkhandelwal858 Před 3 lety

    We should change blast or should bypass it ?

    • @diyrepairs
      @diyrepairs  Před 3 lety +1

      it is better to change the ballast, because if you bypass, UV lamp will not work.

    • @shubhamkhandelwal858
      @shubhamkhandelwal858 Před 3 lety

      DIY Repairs and if bypass along with uv lamp chock so as to keep uv functioning.

    • @diyrepairs
      @diyrepairs  Před 3 lety

      @@shubhamkhandelwal858 main part of the ballast is the microcontroller. it also controlls the uv lamp circuit. if ballast is defective then uv lamp will not glow.

  • @ishphaqbhatti5110
    @ishphaqbhatti5110 Před 4 lety

    Sir, I have a kent ro+ uv ballaste.
    The uv ballaste is starting time beeping sound produce than ro will not working.

    • @diyrepairs
      @diyrepairs  Před 4 lety

      reset the ballast Video link
      czcams.com/video/l_LQ_kjcNYQ/video.html

  • @haimurli
    @haimurli Před 3 lety

    Hello I am using Kent pearl
    Continuous like short circuit sound is coming near balast but water is coming
    What could be the problem

    • @diyrepairs
      @diyrepairs  Před 3 lety

      check the connector of ballast. it may be corroded. clean it.

  • @RahulKumar-qx3ys
    @RahulKumar-qx3ys Před 2 lety

    With old float switch?

  • @gmelectricalssalesservice2236

    Pl or video banavo

  • @goodkutty
    @goodkutty Před 4 lety

    Sir I have a grand plus which is not switching on at all times. A tap on the body with my hand sometimes switches on the machine again. What could be the problem ? Loose connection ? Please help.

    • @diyrepairs
      @diyrepairs  Před 4 lety +1

      yes loose connection or Sometimes the wire connectors rust due to moisture. open the machine and check it.

    • @goodkutty
      @goodkutty Před 4 lety +1

      @@diyrepairs Thanks !

  • @recordrepository1914
    @recordrepository1914 Před 4 lety

    Sir, i hv a Kent Excell + model. The connection from SMPS to 2 Pin on ballast gets heated up and sometimes doesn't works. What can be the fix ?

    • @diyrepairs
      @diyrepairs  Před 4 lety

      environment inside the RO is humid which can cause deposition of copper sulphate on connectors. open the connector and check for any corrosion, if present then clean it.

    • @sajithka1
      @sajithka1 Před 4 lety

      Thank you for the response, I have checked and cleaned the contacts.
      Can you suggest where can I buy wire harness / ballast for Kent. I didn't see it online.

    • @sap123singh
      @sap123singh Před 3 lety

      hhji

  • @brijeshprajapati838
    @brijeshprajapati838 Před 2 lety

    1 and 3 pin out of 7 pins are not giving 24v ..
    What to do?

    • @diyrepairs
      @diyrepairs  Před 2 lety

      check 24 volt from smps at pin 6 and 7 then float switch which is connected at pin no.2

  • @deepakmaheshwari6430
    @deepakmaheshwari6430 Před 4 lety

    Hello, I have Kent Grand + water purifier, have tried doing ballast reset for alarm, but it didn't work. The ballast bypass seems complicated and needs change of a part, is there any simpler way to get the purifier working during lockdown?

    • @diyrepairs
      @diyrepairs  Před 4 lety +1

      switch off the machine for some time then again try to reset the ballast. During reset, machine should be on. if fail then do the bypass. Bypassing is very simple just take out the connector from the ballast and you have to connect two jumpers as shown in the diagram in video. no need to change the overflow switch during lock down. Just switch off the machine, when water is about to fill in the tank.

    • @deepakmaheshwari6430
      @deepakmaheshwari6430 Před 4 lety

      Thanks a lot, I put the two jumper wires and it worked. You also mentioned another video to get the UV lamp working, can you please provide the link

    • @diyrepairs
      @diyrepairs  Před 4 lety

      Video link
      czcams.com/video/4HqjNFCnFRk/video.html

    • @pradipbarot1713
      @pradipbarot1713 Před 4 lety

      Aapne blast bypass kiya magar usme magnetic switch ki jagah par kya flot switch lagana jaroori tha? Magnatic switch ok Rahagato vo use kar sakte ha kya ? Uv chalane ke liye algse uv choke laga sakte ha kya ?

    • @rolandsequeira
      @rolandsequeira Před rokem

      kent purposely made the ballast that when you try to reset the entire circuit fails then you have to get a new ballast for 2-3k, better is to bypass it and save your money.

  • @k.s.srinivasan6846
    @k.s.srinivasan6846 Před 28 dny

    How is UV LAMP REMAIN CONNECTED.

    • @diyrepairs
      @diyrepairs  Před 27 dny

      Since we have bypassed the ballast, the UV lamp will no longer work. I have uploaded two videos for making simple UV lamp driver and one video for extracting the UV lamp circuit from the ballast. You can watch these videos on the playlist named kent RO on my channel.

  • @starpainter559
    @starpainter559 Před rokem

    Cooler pump connect kaha say kary aapy pass water tank nah hai

  • @deepeshyadav121
    @deepeshyadav121 Před 4 lety

    Can i remove pressure switch and connect wire directly. Is there any problem

    • @diyrepairs
      @diyrepairs  Před 4 lety +1

      yes sir, you can connect wires directly. this is only to protect booster pump and to prevent air gap in pipes.

    • @deepeshyadav121
      @deepeshyadav121 Před 4 lety

      @@diyrepairs thank you😊

    • @diyrepairs
      @diyrepairs  Před 4 lety

      @@deepeshyadav121 welcome

  • @vipinsingla7757
    @vipinsingla7757 Před 3 lety

    Hi, Thanks for such a nice video explaining in detail. In my case, I got the UV fail alarm and reset switch also didn't solve the problem. I changed the UV lamp also thinking it might have got problems. But even after that i get the UV fail alarm. (Its a single short beep and then 2 sec silent). When i start the machine it switches on and off UV lamp 2 times and then starts beeping. I can see the aqua light in the UV chamber so UV lamp is fine. For 1 day it automatically worked also but then failed again after 1 day. I doubt that blast might have failed. For the time being I am bypassing the blast, but wanted to know is there some way I can check which component in the choke/blast is faulty and replace it only. Float switch is giving 22 volts high correctly but I do not get 22 volts for SV and pump. So this makes me thing some fault in choke itself.
    Thanks.

    • @diyrepairs
      @diyrepairs  Před 3 lety

      short beep after 2 sec is a signal of UV fail, but you say that UV lamp is good. then check the sensor of UV lamp inside the ballast. the sensor consist 4 zener diode connected in bridge with small toroidal transformer after the big transformer. check the diodes and and other components in uv section. if still not find any bad components then the microcontroller might be defective.

    • @vipinsingla7757
      @vipinsingla7757 Před 3 lety

      @@diyrepairs Thanks for a quick reply. I am not from electronics background. It will be great if you can tell me how does the sensor look? I do have multimeter, soldering iron etc. Can i test it using multimeter? how?

    • @diyrepairs
      @diyrepairs  Před 3 lety +1

      @@vipinsingla7757 yes you can check with multimeter. send the pic of the board at sushilkr11@rediffmail.com

    • @vipinsingla7757
      @vipinsingla7757 Před 3 lety

      @@diyrepairs hi
      Sorry took a little long to reply. The image of my uv choke is at drive.google.com/file/d/1NBySXhpfVowfy-Evzi2M0F78v12_Rq9O/view?usp=drivesdk

    • @gs7458
      @gs7458 Před 4 měsíci

      RO system never stop delivering water if need filters replacement until water flow is there. Only taste changed.
      Normal beep can reset only part damage can be level sensor. That can be by pass.

  • @officialhonorupdates
    @officialhonorupdates Před 2 lety

    My filter power supply always go bad like in 1 month or 2 why ? That too that power supply is orginal Kent one

    • @diyrepairs
      @diyrepairs  Před 2 lety

      Check for fluctuations in the power supply coming from the power grid. change your phase from electric pole.

    • @officialhonorupdates
      @officialhonorupdates Před 2 lety

      @@diyrepairs no power fluctuations still power supply is getting bad i tried to change all ro candles too membrane sediment ect sv too still same problem

    • @diyrepairs
      @diyrepairs  Před 2 lety

      filters have nothing to do with the power supply. only ballast, solenoid valve and booster pump can affect the power supply. change the ballast.

  • @prasadkarlekar7856
    @prasadkarlekar7856 Před 4 lety

    Wt would be the problem? Continues non stop beeeeeeeeeee... sound and RO is not working? UV light also off. ?

    • @diyrepairs
      @diyrepairs  Před 4 lety

      Actually the choke or ballast inside the machine is programmed in such a way that after 700 hours of use it starts beeping. It does not give the exact condition of your filters, when uv lamp fails, also then ballast beeps. UV fail alarm sign is 2 short beep in every 2 second. try to reset the ballast. Video link
      czcams.com/video/l_LQ_kjcNYQ/video.html

    • @prasadkarlekar7856
      @prasadkarlekar7856 Před 4 lety

      @@diyrepairs it's not short beep. . It's countinues "keeeeeee......." sound.

    • @diyrepairs
      @diyrepairs  Před 4 lety +1

      @@prasadkarlekar7856 this sound is a indicator of filter change. you can reset it.

  • @applebpo5059
    @applebpo5059 Před 4 lety

    sir wonsering can i bypass the whole RO system in my Kent RO ? i dont need RO water i just need the UV +UF, thanks in advance

    • @diyrepairs
      @diyrepairs  Před 4 lety +1

      yes sir you can www.google.co.in/url?sa=t&rct=j&q=&esrc=s&source=web&cd=27&cad=rja&uact=8&ved=2ahUKEwiVgvKGsP_oAhVfzTgGHYdtBTMQFjAaegQIAxAB&url=https%3A%2F%2Fwww.kent.co.in%2Fpdf%2Fkent-grand-user-manual-new.pdf&usg=AOvVaw20E8MmcFZZ6TSyIce85D8u this is the link of user manual of kent grand plus . page no 6 has diagram.

    • @applebpo5059
      @applebpo5059 Před 4 lety

      @@diyrepairs thanks sir , i am not a tech guy , so just removing the membrane will do ? or i need to remove anything else too?

    • @diyrepairs
      @diyrepairs  Před 4 lety +1

      @@applebpo5059 only remove membrane and booster pump but do not remove solenoid valve. other filters do not change water TDS.

    • @applebpo5059
      @applebpo5059 Před 4 lety +1

      @@diyrepairs thank you

    • @deepakmaheshwari6430
      @deepakmaheshwari6430 Před 4 lety

      @@diyrepairs thanks for response, does this mean there is need for new parts and UV lamp has gone bad?

  • @RahulKumar-qx3ys
    @RahulKumar-qx3ys Před 2 lety

    Can I bypass old float switch ?

    • @diyrepairs
      @diyrepairs  Před 2 lety +1

      float switch is important to stop the machine when water tank is full. you cannot bypass it.

    • @RahulKumar-qx3ys
      @RahulKumar-qx3ys Před 2 lety

      @@diyrepairs old switch are not required .

  • @ravishaw9157
    @ravishaw9157 Před 4 lety

    sir , i have pureit ultima Ro can you please help me in bypassing the same from its circuit board. its shows error and stops water dispensing. Can u please help? i have already spent more than the cost of purifier in the name of maintenance .

    • @diyrepairs
      @diyrepairs  Před 4 lety +1

      Basically each RO system has 3 to 4 electrical systems. They are pressure motor, UV lamp, solenoid valve, autoflush valve. They all receive power from smps and the main board (ballast). To bypass the main board, connect float switch(it should be switch type not magnetic type) in series with smps and then connect directly to both the motor and solenoid valves. The motor and solenoid valves are connected parallel to each other. when you bypass this way your uv lamp will not work. to make it work you have to put a uv lamp driver circuit.

    • @ravishaw9157
      @ravishaw9157 Před 4 lety

      @@diyrepairs Okay! I will definitely DIM(do it myself) and let you know the the results. Many thanks for intended help. :) Thank u

  • @powergridmapusa5156
    @powergridmapusa5156 Před 4 lety

    Can RO candle may be bypassed in water purifier

    • @diyrepairs
      @diyrepairs  Před 4 lety

      yes it can be bypassed but RO is the main filter, it can filter the dissolve salts in water, all other filters are just for removing sediments impurities like sand, dust, rust etc.

  • @deepaksantwani1422
    @deepaksantwani1422 Před 4 lety

    Sir aquaguard superb chip wala filter bypass karana ho to kese kare

    • @diyrepairs
      @diyrepairs  Před 4 lety

      i do not have this water filter. if you send me the block diagram of your filter which is available in manual then i will suggest you. sushilkr11@rediffmail.com

  • @somashekarsoma7267
    @somashekarsoma7267 Před 4 lety

    You are showing two types of bypass connection. Which way is better to connect bypass?

    • @diyrepairs
      @diyrepairs  Před 4 lety

      Both are similar, you can use any. My aim was to show that the booster pump does not have polarity.

    • @somashekarsoma7267
      @somashekarsoma7267 Před 4 lety

      @@diyrepairs thank for giving very use full information. Please upload pure it ultima active copper purifier installation video.

  • @vishnugupta2050
    @vishnugupta2050 Před 3 lety

    How to by pass RO membrane ?
    Our water TDS is already in range of 150 PPM

    • @diyrepairs
      @diyrepairs  Před 3 lety

      bypass the membrane by taking out input pipe from membrane and connect it to the uv chamber or simply open the TDS controller valve to maximum. Video link
      czcams.com/video/pE4riKO4tHY/video.html

  • @CSPatil-bd5tv
    @CSPatil-bd5tv Před 4 lety

    Sir aquar gaurd service kit price was very hight make a vedio to bypass 3 chiptype filters in PCB filter model aquagaurd NRICH HD UV model

  • @yashjaiswal3683
    @yashjaiswal3683 Před 4 lety

    How much does a new ballast cost?

  • @preetamthakur
    @preetamthakur Před 3 lety

    Your audio is not loud enough to be perceptible.

  • @imranrahman4488
    @imranrahman4488 Před 2 lety

    Please hindi mey

  • @imranrahman4488
    @imranrahman4488 Před 2 lety

    Sir hindi me

    • @diyrepairs
      @diyrepairs  Před 2 lety

      ok sir, abhi jitna bhi video daal raha hoon wo hindi aur english dono me hain.

  • @anirbanjsr
    @anirbanjsr Před 3 lety

    Sir, please guid me...in my kent RO uv ballast is producing sound of kit kit and red led blinking continuously.. machine is not starting only sound and red light blinking..what is the issue...kindly help

    • @diyrepairs
      @diyrepairs  Před 3 lety

      if 2 short beep in every 2 second then UV lamp is bad. change the UV lamp.Video link
      czcams.com/video/S8BxVBPIdUc/video.html
      if some other type of beeping then reset the ballast. Video link
      czcams.com/video/l_LQ_kjcNYQ/video.html

    • @anirbanjsr
      @anirbanjsr Před 3 lety

      @@diyrepairs sir it's not beeping it is continuously off on and red led blinking

    • @diyrepairs
      @diyrepairs  Před 3 lety

      @@anirbanjsr try to reset the ballast