Understanding International Plumbing Code: Water Pipe Sizing

Sdílet
Vložit
  • čas přidán 24. 10. 2023
  • International Plumbing Code addresses water pipe sizing in Appendix E in the back of the book. There are several methods for water pipe sizing. There is the segmented loss method, which involves a lot of calculations as pressure losses from pipe, valves and fittings are subtracted.
    The more basic method is the Selection of Pipe Size method. In this video Plumber-Tom explains the four basic steps for this method, and then demonstrates the use of the method using several examples.
    This video is based on the 2021 International Plumbing Code.
    To purchase a copy of Plumber-Tom's study companion published by Upstryve, click on this link: www.amazon.com/Journeyman-Plu...
  • Zábava

Komentáře • 40

  • @ryantags4677
    @ryantags4677 Před 3 měsíci +3

    Tom, I don’t know if you’re going to see this and I don’t know how to get in touch with you personally. I passed my New Hampshire plumbing code test because of you.
    You are a very good teacher, in knowledge and how you delivered the information.
    I already had my Massachusettes Plumbing license, but I was just testing in New Hampshire because that’s where I live.
    I was out of the game for two years, so I forgot pretty much some of the stuff I learned in Massachusetts. I know it’s similar but it’s still different.
    Thank you from the bottom of my heart . You the man.

    • @plumber-tom9470
      @plumber-tom9470  Před 3 měsíci

      Awesome! Glad to hear it! Congratulations on passing your test.

  • @mountainplumbing
    @mountainplumbing Před 3 měsíci +1

    Awesome. 30 years and have a lot of rule of thumb experience. Working on some design builds with minimal prints. Mostly have done commercial work. So, never had to size anything. A lot of help. Subscribed and added to favorites. Thanks sir.

  • @user-ly5ew7zt2z
    @user-ly5ew7zt2z Před 4 měsíci +1

    I work in commercial / industrial pipe design. This is a clear explanation of how to size pipe.

  • @palanikumar8267
    @palanikumar8267 Před 2 měsíci +1

    Hi Tom. Very useful. I interest to see Chapter 11 Storm Drainage. Thanks

  • @MrTay675
    @MrTay675 Před 6 měsíci

    Wish I found you sooner. About to take my exam this Friday and not ready. Your videos make it much easier to understand

  • @jacobgeorge7801
    @jacobgeorge7801 Před 8 měsíci

    Great start, Practice problems!!!!!!!

  • @codyg3423
    @codyg3423 Před 8 měsíci

    Man this is awesome. I take my masters test December 1st. It’s been 12 years since I took my journeyman test. I appreciate you taking time to help teach!

    • @plumber-tom9470
      @plumber-tom9470  Před 8 měsíci

      Thanks! I hope these videos are helpful. I'm glad you have your test schedule. You can do this!

    • @codyg3423
      @codyg3423 Před 7 měsíci

      I passed! Thanks again. Great stuff!

    • @plumber-tom9470
      @plumber-tom9470  Před 7 měsíci

      Awesome! Your hard work paid off! Nice job!@@codyg3423

    • @user-xd9qj1hm2x
      @user-xd9qj1hm2x Před 3 měsíci

      Boss plz confirm me international standard plumbing mearments. Thanks

  • @mattm2177
    @mattm2177 Před 2 měsíci

    You forgot a couple of very important steps - 2.1 deduct 0.5 psi for each foot of difference in elevation, and Step 3 - multiply total developed length by 1.5 for pressure loss through fittings. Very important for the test.

  • @XPERTMINDing
    @XPERTMINDing Před 2 měsíci

    Hey!! nice video really helpfull.. could you answer a few question i have...
    do we consider the pressure loss due to fitting, elevation, meter and backflow preventer? in code its mention to multiply dev. length by 1.2 for fitting. is it right?
    and do you get an accurate answer for service pipe being lesser than building pipe. Thanks

    • @plumber-tom9470
      @plumber-tom9470  Před měsícem

      You can go deep into the details, but I don't know if it is worth the time. When in doubt, oversize a little. I don't think the service needs to be bigger than the main distribution line in the building if the service pressure is higher than what is delivered in the building after the PRV.

  • @samn2160
    @samn2160 Před 3 měsíci

    What about if you exceed the developed length based on Table E201.1? Can I still apply the simple method?

    • @plumber-tom9470
      @plumber-tom9470  Před 3 měsíci

      If your length exceeds the charts, go big. There will be friction loss over the long distance

  • @DontLookBehindYou1
    @DontLookBehindYou1 Před 2 měsíci

    Hey Tom or comments section...
    With water savers being almost everywhere in the house, say on a 2 1/2 bathroom house, if you bring 1" into the house then 3/4" to water heater, and branch off with 1/2... would using extra 90s instead swoop/looping the PEX make a big difference when it's near the fixtures? There's some places that make it very difficult to swoop... I'm wondering -- since everything is ~ 2.2 gallons per minute approximately, if it's not near a hose bibb, washing machine, or water heater, will using extra 90s before the fixture actually affect the flow with a properly set PRV.
    I wasn't really sure how to even calculate this particular situation or if it even needed to be addressed with such low flow in showerheads and aerators.
    I couldn't really find it addressed anywhere in the book

    • @plumber-tom9470
      @plumber-tom9470  Před měsícem +1

      I use 90s instead of tight loops. I think, as you mentioned, with low flow faucets and shower heads, a few 90s really does not affect delivery that much. I have never had customers complain, and I set up my houses about like you described.

    • @DontLookBehindYou1
      @DontLookBehindYou1 Před měsícem

      @@plumber-tom9470 thank you for that info. I haven't had anyone complain either, but recently it seems like customers are reading or YouTubing and have acquired this info about 90s and are seeming to be really anal about them and their turns.
      Again... Appreciate you and your channel.

    • @plumber-tom9470
      @plumber-tom9470  Před měsícem

      @@DontLookBehindYou1 Interesting. You can remind them that you are the expert. 😎

    • @DontLookBehindYou1
      @DontLookBehindYou1 Před měsícem

      @@plumber-tom9470
      Epic response

  • @user-ey6wv8xh1h
    @user-ey6wv8xh1h Před 6 měsíci

    what about buildings with multiple floors. don't we loose head pressure going vertical ?

    • @plumber-tom9470
      @plumber-tom9470  Před 6 měsíci

      Yes. For every 1 foot of vertical rise the pressure will decrease by 0.433 psi. So the higher it has to go, the lower the pressure will be.

  • @je-niseghana7377
    @je-niseghana7377 Před 5 měsíci

    Thanks for taking your time to teach into details. With regards to step 2, what if you're using roof water tanks...about 6no 2500litres tanks with height 1.33m and diameter 1.55m? how do you calculate the psi ?

    • @plumber-tom9470
      @plumber-tom9470  Před 5 měsíci +1

      Hello. The PSI would be determined by the height of the tank above the ground. The size of the tank is not important, but the pull of gravity is. So you would take the height of the tank above the ground and multiply by 0.433 to get the psi at ground level. Then remember that for every foot above ground, you lose 0.433 psi. So at 10 feet you would subtract 4.33 psi from your reading at ground level, and so on.

    • @je-niseghana7377
      @je-niseghana7377 Před 5 měsíci

      @@plumber-tom9470 also with regards to the pressure ranges in determining the service and distribution pipe size .....the lowest pressure range in the IPC book is 30 to 39 psi. What do you do if your pressure is lower? let's say 11psi.574?

    • @je-niseghana7377
      @je-niseghana7377 Před 5 měsíci

      ​@@plumber-tom9470 Also what type of pipe is the main service or meter pipe in Table 104.1 refering to? is it PPR pipes or uPVC pipes?.....asking because 1/2" ppr pipe differs in size to 1/2" uPVC pipe?

    • @plumber-tom9470
      @plumber-tom9470  Před 4 měsíci +1

      11 psi is not sufficient to provide adequate flow at fixtures. Chapter 6 details minimum flow rates and pressures. Even 30 psi to 39 psi leaves fixtures with poor delivery. @@je-niseghana7377

    • @plumber-tom9470
      @plumber-tom9470  Před 4 měsíci +1

      approved water pipe options can be found on the tables in IPC 6 tables 605.3 and 605.4 @@je-niseghana7377