Does Annual Maintenance on HVAC Systems Matter? MUST WATCH Tips from Master Plumber

Sdílet
Vložit
  • čas přidán 4. 03. 2024
  • During this actual service call we performed a combustion test BEFORE a cleaning and tuneup. Then another AFTER! The results will shock you!
    Make The Trades Great Again! Join Mikey Pipes Philanthropy, Inc., an IRS 501(c)(3) non-profit public charitable organization. Our mission is to offer free or low-cost plumbing, heating and cooling services to those in our community who can't afford to hire a professional. Help us here: www.paypal.com/donate/?hosted...
    Curious on our dispatching and invoicing app? Check out HouseCallPro: tinyurl.com/MikeyPipesHCP
    What’s in your Veto? Here is mine:
    Veto TP-XXL amzn.to/3zX10vg
    Testo Combustion Analyzer: amzn.to/3Zd7naH
    Digital Manometer: amzn.to/3EDt5ey
    Milwaukee M18 Blower: amzn.to/46iTo6j
    Milwaukee M12 Fuel 1/4" Impact Driver amzn.to/3I9yLfI
    Milwaukee PVC cutter: amzn.to/3sbrdUc
    Mini Waterproof Storage bin: amzn.to/3yfgsEv
    Wiha Allen Keys: amzn.to/33ipGmb
    HIKMICRO B20 amzn.to/33iGklx
    Furnace Switch amzn.to/31X89PT
    Milwaukee Light amzn.to/3I38Lmh
    Wagos amzn.to/34QoiaU
    Milwaukee Set amzn.to/33vnQOz
    Torpedo Level amzn.to/3no1oOk
    Crescent set amzn.to/3GtZeV8
    Wiha 7 piece set amzn.to/3rkISaK
    Milwaukee step bit amzn.to/3I395Bv
    Thermocouple Flare wrench: amzn.to/3noJZ8s
    Ridgid 10” wrench amzn.to/3GvRnqa
    Fluke non-contact tester amzn.to/31VQgAQ
    Klein drivers amzn.to/3qoe21W
    Knipex Wrenches amzn.to/3trzFjS
    Klein 11-1 amzn.to/3tpsPLD
    12” crescent amzn.to/3A0CZ6S
    Gerber Gear Pocket Knife amzn.to/3foaW7I
    Yellow Jacket Hand Ratchet amzn.to/3nrDgup
    I am on Discord & WhatsApp!
    Discord: / discord
    WhatsApp Group: chat.whatsapp.com/CHZWtZe4KMG...
    Mikey Pipes Uncensored: / @mikeypipesuncensored
    New oval raised silver stickers are from:
    Armored Decal Company Inc.
    35 Victoria St. E, Unit 9
    Alliston, Ontario L9R 1T3
    (p) 705-435-6665
    (e) ken@armoreddecal.com
    (Tell them Mikey Pipes sent you)
    Please support this channel and Mikey Pipes and consider the following…
    Pipe Doctor FlexFit Embroidered Caps
    Minimum donation of $37 is appreciated
    (If you are international - please add a minimum of $40 for shipping/postage)
    Shopping on Amazon? Please use my referral link amzn.to/2PjjS4v
    Sticker Requests:
    Do you want a sticker to show your support of this channel? Email your request to me! mike@mikeypipes.com
    Name
    Address
    City, State, Zip
    Consider making a donation of $5.00, or ANY amount, to the postage fund! I literally mail out stickers all over the globe. I've sent stickers to HVAC guys in Afghanistan, New Zealand & all over Europe.
    PayPal is: office@pipedoc.net
    Venmo: @PipeDoctor
    CashApp: $mikeypipesny
    Zelle: mike@mikeypipes.com
    Want to send a love letter, note or gift? Our mailing address is:
    Mikey Pipes, Inc.
    1010 Central Avenue
    Woodmere, NY 11598
    #plumber #hvac #mikeypipes
  • Jak na to + styl

Komentáře • 60

  • @antoniolaracuente437
    @antoniolaracuente437 Před 4 měsíci +6

    I wish I can go back 40 years and have these videos I was trained by the wrong guys who are deceased now I love your perfectionism I watch your videos for years now thank you again Mike

    • @earlestes8649
      @earlestes8649 Před 4 měsíci

      Ru retired now? Sounds like it. I am retired but I’m still doing some work when able, and not sick or in hospital

  • @Chris_In_Texas
    @Chris_In_Texas Před 4 měsíci +4

    27:17 Did you notice on the low water cutoff that came off that it states "DO NOT USE PIPE SEALANT. ONLY USE TEFLON TAPE AND HAND TIGHTEN." 🤠👍

    • @petesilvestri
      @petesilvestri Před 4 měsíci +3

      Good catch…. Looks like someone can’t read 🤣

    • @TheRAMBO9191
      @TheRAMBO9191 Před 4 měsíci

      And if you notice at 28:35....it states to use the manual for new item. Manual takes over anything else. 🤠

    • @Chris_In_Texas
      @Chris_In_Texas Před 4 měsíci +1

      @@TheRAMBO9191Except that the manual is for the much newer version that is brass threaded, and not plastic threaded like that older version, that was installed. 😉👍

  • @abrucetar
    @abrucetar Před 4 měsíci +5

    I was stating to think you were not going to bless us tonight! Now I can relax

    • @PipeDoctor
      @PipeDoctor  Před 4 měsíci +4

      Hope you enjoyed it!

    • @abrucetar
      @abrucetar Před 4 měsíci +2

      @@PipeDoctor it was a great educational episode

  • @xxk0pxx
    @xxk0pxx Před 4 měsíci +4

    Great explanation of everything completed on this system. The customer sounded very happy with the work you did. 👏 👏 👏 👏

  • @nikyjim
    @nikyjim Před 4 měsíci +1

    I like the floor drain around the boiler and HWT

  • @kens.3729
    @kens.3729 Před 4 měsíci +2

    Very Nice Updates, Mike! 👍🙏

  • @dgeoffreyfitton2836
    @dgeoffreyfitton2836 Před 4 měsíci

    very professional and cost sensitive work, well done Mikey

  • @PedroPerez-rw1uy
    @PedroPerez-rw1uy Před 4 měsíci +2

    PTFE stands for polytetrafluoroethylene and is a synthetic fluoropolymer AKA thread seal tape/teflon tape/plumber's tape.
    My husband and I really enjoy your CZcamss. Explanations are clear and understandable. Keep up the great job!👍

  • @antoniolaracuente437
    @antoniolaracuente437 Před 4 měsíci +1

    Thank you Mikey for all this great information you are the man

  • @jetboy770371
    @jetboy770371 Před 3 měsíci +1

    Sitting in our cold house on a Saturday waiting for a HVAC repairman to come on Monday to troubleshoot our boiler. I have been watching yours and similar videos to get a better understanding of the entire system. Our older system has 4 zones and looks to be all in the correct location except our expansion tank is mounted horizontal. The boiler won't fire for some reason. Several days ago it failed to fire and I turned off the power main power switch momentarily and back on and the flue valve opened and the boiler fired up. That trick stopped working for me and now stone cold. Only the pilot is working. As far as maintenance they come and vacuum out like you did and that's it for $85. Just looking at the condition I see water leaking from the air scoop thingy. The expansion valve is probably beyond it's service life and maybe several other components. I'm a retired airline mechanic and things like this really interest me. This hydronic heating doesn't seem to be popular and fewer repairmen will take the job. I'm thinking transformer failed. It needs a major inspection and overhaul like a aircraft.

    • @PipeDoctor
      @PipeDoctor  Před 3 měsíci +1

      Sometimes it’s best to have a professional come in every couple years and look over the whole system with a fine tooth comb

  • @bronsonmccall6845
    @bronsonmccall6845 Před 4 měsíci +1

    Good educational video. St. Mike!

  • @jasongeo2
    @jasongeo2 Před 4 měsíci

    Mike you are great at drilling those fresh holes....owwwww.

  • @T.MacThePlumber-ny5dj
    @T.MacThePlumber-ny5dj Před 4 měsíci

    Plastci shank, wooah. That part has 2 b are around $500-$600. Nice work Mike !

  • @matteberry58
    @matteberry58 Před 4 měsíci

    I live in Texas, so the only knowledge I have on boilers is from you and Daniel-son. I've been watching you for 3 years. I do watch Steve L in NE, because he's pretty darn funny. "She's a crusty one!" If I ever a home I will put hydronic in slab heating. I hate forced air heating! Shalom.

  • @phillipjoy1305
    @phillipjoy1305 Před 4 měsíci +1

    Great videos 😊

  • @MokenaBob
    @MokenaBob Před 4 měsíci

    👍Great Job
    always

  • @chuckq54
    @chuckq54 Před 4 měsíci +1

    Sweet job Mikey 👍 Agree 100% on replacement of the thermocouple during this service…I’m guessing you have a new client now 👍👍🏆🏆

  • @scottvolage1752
    @scottvolage1752 Před 4 měsíci +1

    Makey Pipes Keeping it real. Make the trades great again. Smash that Like button. Smash it.

  • @kat2641
    @kat2641 Před 4 měsíci +4

    I just CAN NOT understand why Tecks install expansion tanks every direction but the right way 🤦‍♂️🤷🏻‍♂️ nice service!!!!

    • @cliveramsbotty6077
      @cliveramsbotty6077 Před 3 měsíci +1

      where does it say they always need to be installed on the hang? thanks

    • @kat2641
      @kat2641 Před 3 měsíci +1

      @@cliveramsbotty6077
      Pick a company brand an Google the proper installation. Most come with directions on proper positioning. To my knowledge their is only 1 brand that can be installed laying flat a that is for domestic hot water not a home residential/commercial heating boiler. Now can you install it backwards? Yes but the diaphragm inside was not designed to have pressure on only one part of the diaphragm.. usually result in early failure. I can always tell if an install was inspected by an Inspector, if it’s in the wrong position you know a permit was not drawled on the install an/or replacement if Things are not properly professionally installed correctly ( edited fur a spell boo boo)

  • @jimmy8653
    @jimmy8653 Před 4 měsíci

    That insulation he has behind the boiler is flammable no no no !

  • @petersamios5409
    @petersamios5409 Před 4 měsíci +1

    Nice job as usual-thanks also for the education. I'm also a Caleffi fan.

  • @gomerhondo7249
    @gomerhondo7249 Před 4 měsíci

    LWC with plastic shank states to “only use Teflon tape” (@27:16). So use of Teflon tape is fine for the old one.

  • @rudyseventwo7592
    @rudyseventwo7592 Před 4 měsíci

    RTFM = 💰

    • @PipeDoctor
      @PipeDoctor  Před 4 měsíci

      It’s a win win for all parties.

  • @TheRAMBO9191
    @TheRAMBO9191 Před 4 měsíci

    Wwwoooo! 💪🏻🍻

  • @arunaround5191
    @arunaround5191 Před 4 měsíci

    Shalom Mikey!!! Have you ever left a non luminous pilot flame blue and blowing ?? It appears that all the pilot lights are left yellow tipped only to produce soot and or aldehyde odors...using the tip wire of a pipe cleaner after burning and twisting away the fiber material works great in cleaning the pilot orifice...very surprised that you don't ✔️ check the burner orifices for spiders...lastly that you don't place the burner panel door on the floor as the Boiler is firing up as a shield to protect against gas man eczema 😂😂..just curious and humble suggestions 😂🎉🎉🎉Toda and Shalom

    • @PipeDoctor
      @PipeDoctor  Před 4 měsíci

      Thanks for watching and sharing your comments.

  • @paulyanega2373
    @paulyanega2373 Před 4 měsíci +3

    well done again, did you add screws in the flue ?

  • @AmericanFarmerHVAC2024
    @AmericanFarmerHVAC2024 Před 4 měsíci

    Still havent hung a modine in the shop yet? Probably been so warm you didnt need too!

  • @DCHVAC
    @DCHVAC Před 4 měsíci +3

    First

  • @jamesfitzsimmons5218
    @jamesfitzsimmons5218 Před 4 měsíci

    Good job Micheal. 😊 I was a boilerman for the state. Worked on massive Cleaver Brooks steam and hydronic boilers. Principles the same but on alot larger equipment. Dual fuel that we tuned every year. Kinda miss it. Enjoy watching your videos. Good to see someone who cares about what they do.

  • @flyingmachineworks
    @flyingmachineworks Před 3 měsíci

    Did you ever put the screws in for the flue?

  • @mitchdenner9743
    @mitchdenner9743 Před 4 měsíci +1

    You remind me of the saab mechanic that stole Jerry's car for neglect.

  • @instrumenttech4220
    @instrumenttech4220 Před 4 měsíci

    The old dead men that fought me gas would always clean a lazy pilot like that 😢

  • @Al-sq5ti
    @Al-sq5ti Před 4 měsíci

    Posting kind of late buddy easy peasy

  • @scottmaz4063
    @scottmaz4063 Před 4 měsíci +2

    #2🎉🎉😂😂

  • @greekmaster1001
    @greekmaster1001 Před 4 měsíci

    HACKS=STACKS 💵💵💵💵

  • @thedink5
    @thedink5 Před 4 měsíci

    You lost me at great state of NY! God TEXAS

  • @TheMrBrandonlewis
    @TheMrBrandonlewis Před 4 měsíci

    Polytetrafluoroethylene - paa
    ·
    lee
    ·
    teh
    ·
    truh
    ·
    flaw
    ·
    row
    ·
    eh
    ·
    thuh
    ·
    leen

  • @tphvac87
    @tphvac87 Před 4 měsíci

    What an awful install no air scoop, zone valves, expansion tank wrong orientation, jeez….they went bare bones cheap! Wait did I see only one hy-vent too?

  • @ThumperKJFK
    @ThumperKJFK Před 4 měsíci

    👍✌