condensation in pitched roof, poor ventilation,

Sdílet
Vložit
  • čas přidán 13. 09. 2024
  • No air flow, only vented on one side, need tile vents

Komentáře • 10

  • @leeparkes3819
    @leeparkes3819 Před rokem +2

    simple fixed by inserting short pieces of plastic water main pipe where the first layer of felt overlaps at the bottom, allowing air through the gap created and thro the pipe.
    if the pipes want to slip through the felt laps then simply fit a screw into the top of said pipe thus stoping it falling through

  • @robertcaswell3914
    @robertcaswell3914 Před rokem +2

    Pull that insulation away from felt air flow is blocked

  • @Orgakoyd
    @Orgakoyd Před rokem

    Doesn't this indicate poor airtightness of the attic floor, letting in interior humidity into the cold roof space which then condenses? Just like it does on walls near windows inside the house?

  • @taffytop
    @taffytop Před rokem

    Uninsulated loft hatch, to much heat escaping from the living quarters

  • @gunther1955
    @gunther1955 Před rokem

    Check the basement -if dirt floor needs vapor barrier. Venting will help but stopping moisture from entering is key to solving issue

  • @andytownsend9163
    @andytownsend9163 Před rokem +1

    They will be breathing indoors, cooking food or showering. Big cause of that

  • @30JMD
    @30JMD Před rokem +1

    They will be drying washing indoors. Usually the biggest cause of that

  • @davebatman847
    @davebatman847 Před rokem +1

    Manthorpe lap vents mate

  • @bensmith3613
    @bensmith3613 Před rokem

    Tile vents will help if you put them near the ridge