Oil System YK York Chiller

Sdílet
Vložit
  • čas přidán 27. 08. 2024
  • This is an overview of a YK centrifugal chiller. I walk through the base components of the oil system for hvac technician. HVAC training is a vital part of every tech's career.
    Get 8% off at TruTech Tools with promo HVACTIME
    www.trutechtoo...
    Get tech support, training, and the Tech Blog at hvactimetx.com
    You can contact me at Hvactimetx@gmail.com
    Support my COFFEE problem through,
    venmo.com/code...
    Zelle @ Hvactimetx@gmail.com

Komentáře • 56

  • @HVACTIME
    @HVACTIME  Před 9 měsíci

    YK online training at chilleracademy.com
    Get Confidence and Accuracy with this Troubleshooting Guide!
    hvactime.shop/products/yk-tech-sheet

  • @jpac2g
    @jpac2g Před rokem +10

    This video is pure gold, thank you for sharing your knowledge. Videos like this weren't available, and in this detail, just years ago. I can tell that you know your stuff, keep them coming please, Thank You!

  • @bill8985
    @bill8985 Před rokem +3

    It has been decades since i had to buy, install, and maintain one of these guys... Your explanation was super clear and brought back some nostalgia. Thanks!

  • @Erikmiles87
    @Erikmiles87 Před rokem +1

    Thanks. Was explaining eductor lines to my apprentice. I’m going to show him this video so he can see the internals

  • @twilks7878
    @twilks7878 Před rokem +1

    I love these chiller videos, I work at JCI and you explain better than my JM.

  • @EverythingHVACR
    @EverythingHVACR Před rokem +1

    Great information Holden, thanks

  • @DannyBokma
    @DannyBokma Před rokem

    Ow man, all this information, thanks so much for sharing these insights! What a wonderful world an time we live in ^^!

    • @HVACTIME
      @HVACTIME  Před rokem

      Thank you for the support!

  • @TheRenaissanceBuilder

    Good video bud.
    I giggled a bit over the camera angles only because I recognize how difficult entertaining camera angles can be to find sometimes

  • @tylerferrell2959
    @tylerferrell2959 Před rokem

    Dude you kill it in these videos

  • @GordonHVACR
    @GordonHVACR Před rokem

    Thanks for making this outstanding video! Proud of your hard work !

  • @user-sx1rv9kb2q
    @user-sx1rv9kb2q Před 6 měsíci

    I am a JCI YK centrifugal turbo chiller engineer.
    The video was very helpful.
    I would appreciate it if you could upload more videos. I am curious about the role of each material inside the chiller. The information about the oil line is similar to what I thought. thank you

  • @fathmasameer7523
    @fathmasameer7523 Před rokem

    Great experience you deserve more subscribers dude thanks

  • @onesimpleman1
    @onesimpleman1 Před rokem

    Excellent video on oil system

  • @wata_laf
    @wata_laf Před 8 měsíci

    Wildly informative 👍🏼👍🏼

  • @gatoguevara71
    @gatoguevara71 Před rokem

    Great job thank you for sharing your experience

  • @DronePilot4k
    @DronePilot4k Před 4 měsíci

    Thanks!

  • @bornjanuary25
    @bornjanuary25 Před rokem

    Kindly make review for Carrier chiller GX30 and 30GT with your amazing manner ( operation , service and maintenance )

  • @DronePilot4k
    @DronePilot4k Před 4 měsíci

    Thanks for the video , appreciate you taking the time to share. What is the sequence for the solenoid on the oil return line? Is it open during on cycles and closed on off cycles?

    • @HVACTIME
      @HVACTIME  Před 4 měsíci +1

      Yes, and the oil temp will influence it opening

    • @DronePilot4k
      @DronePilot4k Před 4 měsíci

      Thank you very much , so if the oil temperature in the sump is already low it will stay closed?

    • @HVACTIME
      @HVACTIME  Před 4 měsíci +1

      @@DronePilot4k exactly

  • @texture6
    @texture6 Před rokem

    Thank you to infinity

  • @dmc357
    @dmc357 Před rokem

    Great video!!

  • @igariokmihailov4461
    @igariokmihailov4461 Před 7 měsíci

    great video buddy, i have a small leak on the oil sight glass, could be the o-ring , do i have to drain the oil in order to replace it, or i have to remove the front plate also? Thanks in advance

  • @brandonwalker4842
    @brandonwalker4842 Před 8 měsíci +1

    Did you have to recover all the refrigerant to work on the sump or where you able to isolate. I have to work on oil sump. I have isolation valve on discharge piping going to condenser but nothing on the evap. So, my question to you is do I need to recover the entire charge.

    • @HVACTIME
      @HVACTIME  Před 8 měsíci

      Yes, you wiil need to recover charge.

  • @Henryolson09
    @Henryolson09 Před 6 měsíci

    Ferncos and PVC on the pressure safety valves!? That might be worse than not piping them outside at all

  • @jasonjohnsonHVAC
    @jasonjohnsonHVAC Před rokem

    Good stuff

  • @hvac8826
    @hvac8826 Před měsícem

  • @kobebryant4750
    @kobebryant4750 Před rokem

    What is the meaning of oil variable speed pump contacts open? Plss help me

  • @rmalanis13
    @rmalanis13 Před měsícem

    Having issues with a yk right now. While running sump LOP is about 60psig and evap is 38 psig. Changed oil filter and eductor. All valves open. Oil return solenoid working. But eductor filter stays hot, could it be bad balance piston seal, or faulty/plugged eductor block? If any one can assist it would be greatly appreciated

    • @rmalanis13
      @rmalanis13 Před měsícem

      To clarify Changed eductor filter, not block

  • @justinkendollrozinek
    @justinkendollrozinek Před rokem

    Super smart

  • @foodtravelxp24
    @foodtravelxp24 Před 11 měsíci

    Dear boss my york centrifugal chiller a Alam coming oil-low differential pressure calibration. So i can remove this alarm??

  • @user-rd5vm7si4o
    @user-rd5vm7si4o Před 7 měsíci

    please advice have you ever have this problem ?, I am getting the oil loss in oil sump chiller York YK Centrifugal. The oil seems goes to evaporator
    The above problems occurs after :
    1. We have changed the oil Return Solenoid
    2. add extra valve for changing the TXV oil temp control (so if we need to change the txv no need to transfer pump down the R134a)
    3. Change the new oil pump
    The actions that we already redone :
    1. change again the oil return solenoid to the old one
    2. change the oil cooler heat exchanger
    3. change the txv oil temp control to the old one, but the extra valve for service still there (because of welded)
    4. checking the oil block eductor inside the oil sump ( the springs are doing pretty well)
    The problem still remain ,getting the oil loss in oil sump chiller York YK Centrifugal. The oil seems goes to evaporator
    please advice, do you have any suggestion

    • @HVACTIME
      @HVACTIME  Před 7 měsíci

      How much run time in-between trips?

    • @user-rd5vm7si4o
      @user-rd5vm7si4o Před 7 měsíci

      only about start up 5 minutes , the oil sump level already minimum. The chiller still can run, but we just turn off the chiller off because the low level oil

    • @user-rd5vm7si4o
      @user-rd5vm7si4o Před 7 měsíci

      before we already pump down out the oil in the evaporator with its r134a , drain all the r134a and the oil in evaporator side

  • @jarredallen
    @jarredallen Před rokem

    I hate opening york chiller oil sump. they are always in an awkward location. they either in between compressor and condenser shell or at the bottom of the shells.

  • @andrewjacks8671
    @andrewjacks8671 Před 11 měsíci

    What does MTT mean? Multi-task trebuchet?

    • @HVACTIME
      @HVACTIME  Před 11 měsíci +1

      Make The Time for your spouse and family with our busy schedules.

    • @andrewjacks8671
      @andrewjacks8671 Před 11 měsíci

      @@HVACTIME MTT. I like it. Thanks for the in-depth videos. Much appreciated.

  • @joshstevens9826
    @joshstevens9826 Před rokem

    I'm curious, do you take annual oil samples?
    Or is it when a problem is suspected?
    Where I am wr do filters and oil samples with every annual we do.

    • @HVACTIME
      @HVACTIME  Před rokem

      I do annual samples with lab analysis

  • @technicalfeatures5748

    Sir can you tell me how to cooling YK chiller heartsink, i have facing this problem high heart sink temperature

  • @Ariff-zt2gc
    @Ariff-zt2gc Před rokem

    Hi bro Holden , basically i've experiencing quite a number of times OIL - VARIABLE SPEED PUMP - DRIVE CONTACTS OPEN FAULT ALARM .
    Checked and verified no voltage across the output . Replaced to a brand new VSOP Board as well but the fault came back again in just 2 months . Any other alternatives or solution on what to check ? Can temporarily bypass somewhere to make the system online ?

    • @southendcycleworks
      @southendcycleworks Před rokem

      The VSOP boards lately are not very good quality. They usually come with a 1 year warranty and I've had to use it many times

    • @nellAyaR2034
      @nellAyaR2034 Před rokem

      Might want to get the input line inductor for vsop

  • @HVAC-EngineerRam
    @HVAC-EngineerRam Před rokem

    I want join this channel in Hindi language

  • @HVAC-EngineerRam
    @HVAC-EngineerRam Před rokem

    Sir what is your language

  • @HVAC-EngineerRam
    @HVAC-EngineerRam Před rokem

    This video want in Hindi language please share

  • @ahmedabdeldayem8252
    @ahmedabdeldayem8252 Před měsícem

    thanks for your help but please speak slowly 😅