Future Proof Your Lights When Taking the Feed to the Switch - 2 Plate Method

Sdílet
Vložit
  • čas přidán 26. 07. 2024
  • How to change the connection in a light switch to make sure the electrical installation is future proofed when working at a ceiling rose and pendant. We look at the layout of a ceiling rose and its connections - loop, neutral and switching line. We see how we could replace the twin and CPC from the light switch with a 3 core and CPC and therefore take the permeant line from the switch to the light. The connections in the light switch are for the 2 plate method of wiring a lighting point are explained as well as the new connection in the light.
    🔵 Taking the feed to the switch 2 plate method playlist
    • Taking the Feed (Suppl...
    == 🕐 Time Stamps - Cut to the action 🕕 ==
    00:00 - How to get a permeant line (live) at the light
    00:43 - Neutral at the switch
    01:18 - Taking the feed to the switch (2 plate method)
    01:33 - Connections in the switch
    01:56 - Connection in the lighting point
    03:32 - Lights that come on at the same time
    03:55 - Replace the twin and CPC cable
    04:56 - Wiring a 3 core and CPC from the switch to the light
    05:37 - 3 core conductors identified
    06:26 - Making the 3 core and CPC off into our ceiling rose
    08:37 - Ceiling rose connections
    10:03 - Connection at the switch
    12:14 - Recap the connections at the switch
    Videos are training aids for City and Guilds (C and G) and EAL courses Level 1, 2, 3 plus AM2, AM2S and AM2E.
    You can follow me day by day on Facebook, Instagram, Twitter and TikTok lookout for "GSH Electrical”.
    ▶️ FACEBOOK / gshelectrical
    ▶️ INSTAGRAM / brihzmraygdtmjmdb9lunq...
    ▶️ TWITTER / gsh_electrical
    ▶️ TikTok vm.tiktok.com/ZMRBLFdhe/
    #GSHElectrical #Electricaltrainingvideos

Komentáře • 76

  • @nik2573
    @nik2573 Před 2 lety +5

    Love to see this! I've been doing this for a while now, it makes the installation so much neater & if the customer ever wants home automation in the future then we've got them covered!

  • @KendalMike
    @KendalMike Před 2 lety +10

    I have done all my feeds through light switches for a very long time now and also, where possible, used oval conduit for the switch drops so another cable can be added later. Adding a permanent line to roses as well makes a lot of sense and gives even more flexibility for future alterations. Great Video, Gary.

    • @GSHElectrical
      @GSHElectrical  Před 2 lety

      Thanks for the great comment and watching. Gaz 👍🏻

  • @steve11211
    @steve11211 Před 2 lety +6

    I think this is genius yet simple, I have always been against 2 plate method because its such a pain to get a permanent live for a new accessory, but this either way you do it is a great idea..

    • @GSHElectrical
      @GSHElectrical  Před 2 lety

      Thanks for taking the time to watch and comment 👍🏻 Gaz

  • @tommythomson99
    @tommythomson99 Před 2 lety +2

    Love it.
    Such a simple solution, it should be standard in any rewire.

    • @GSHElectrical
      @GSHElectrical  Před 2 lety

      Thanks for taking the time to comment 👍🏻

  • @snazy7777
    @snazy7777 Před 2 lety +2

    Thank you for the Sunday morning revision 👍

  • @sonicstep
    @sonicstep Před 2 lety +8

    06:33, having a 'permanent feed' is essentially what is done for commercial applications requiring emergency lighting. Including multiple occupier residential homes, hotels, student halls of residence and such like where there would be non-maintained emergency lighting (maintained typically within actual dwellings).
    The commercial aspect to this may be worth covering at some point. You have PIR (passive infrared) activated lights within toilets, office spaces, commmunal corridors to save energy. Luminares within those areas that would have permanent feeds supplying non-maintained luminaires.
    Within office spaces and such like, it's not unusual to have them supplied by LCMs (lighting controller modules) which can be controlled via remote software.

  • @Britcoolful
    @Britcoolful Před 2 lety

    Wow, finaly all normal timing switches from EU can be installed and not those pneumatic rubbish. What a relief, I had to rip all the cables to make it work previously.

  • @hasankhan-ey5oz
    @hasankhan-ey5oz Před 2 lety +3

    Yours videos makes easy to understand consept Good job 👍

  • @rimmersbryggeri
    @rimmersbryggeri Před 2 lety +2

    I like to put tails into the rose ant the fitting with a 2 hole wago on the rose end. Makes it really quick and easy to connect stuff.

  • @markandrews8437
    @markandrews8437 Před 2 lety +2

    These videos are brilliant

  • @jeremykemp3782
    @jeremykemp3782 Před 2 lety +1

    Definitely the way forward, nice video

  • @sukhi17
    @sukhi17 Před 2 lety +3

    I learnt something new 👍

  • @ashvanbro9329
    @ashvanbro9329 Před 2 lety +1

    Great video gaz

  • @thattoolguy9432
    @thattoolguy9432 Před 2 lety +8

    Good idea Gaz, ive been adding 3 cores for a different reason, usualy when adding downlights, as i have had a few calls a few weeks later.. "is it possible to add a 2 gang switch and have certain zones lit .. saved me a ton of headaches.. esp as the plastering has already been done .. i'm going to adopt your idea too .. pennies on the cable but saves a ton of work after the fact

  • @FirstDan2000
    @FirstDan2000 Před 2 lety +3

    Great idea. I'll watch out for opportunities to do this in future.
    I'm often baffled why the cable manufacturers don't give us a blue core in the 3core+CPC cable. I don't remember any time I've ever used a 3core+CPC as a three phase cable.
    Any feedback on this is welcome.
    Thanks for the video.

    • @stuartandrews4344
      @stuartandrews4344 Před 2 lety +1

      Before they harmonised the wire colours way back in March 2004, 3 core and earth' cable used in two way lighting was blue, yellow and red with a bare copper earth, if I wasn't doing 2 way switching, then quite often I us 3 core cable & use blue wire as a netural for future use.Nowadays I tend to use Quinetic wireless switches, no drops to chase, only back boxes,if not surface mounting, 1 receiver can be controlled by up to 10 switches,so 2,3,4 way or more, is so easy now & quicker to install,less mess, so I think offsets the cost of the switches,etc.

  • @BATMANONLINE01
    @BATMANONLINE01 Před 2 lety +3

    Great idea but i dont see many people doing this. More likly to get rid of the cable to the switch completely and use a kinetic

  • @billsbasementworkshop1902

    Hi Gary,
    I wasn'r aware that there was an idustry standard for which colour of conductor was used as newtral.
    I always ues the black as common and the grey as live as well as the brown . All are usually sleved as live conductors.
    Why would the industry try to move away from useing the black as newtral? I'm 65 now and was brought up during my
    training with the old red and black cable, so it is easier for me to use the black as newtral. This is how I remember it.
    Why can't the industry have a standard for this? or at least use the colours of brown, blue and grey and call the blue as newtral.
    Nice video, Keep up the good work, Regards, Bill.

  • @seandempsey7351
    @seandempsey7351 Před 2 lety +2

    Brilliant demonstration and clear explanation, I get the idea behind it, but I don’t think it is a good idea, why we’ll a lot of sparks don’t like Ring mains and don’t stall them some say because we don’t need them and some say it’s a waste of cable ? It seems to me that This type lighting circuit is doing the self same thing only in favour of smart technology,
    So we stop installing Ring to save on cost and reduce the amount of cable used then
    Loose that saving by using more cables on lighting circuits,
    The same as CUs we used to install metal CUs then changed to plastic and now we have to install metal CUs , the industry is going backwards. It’s only technology that’s moving forward’s . The world has gone mad positively gaga I tell you.
    But what do I know ? I’am just a humble electrician who’s opinion means nothing 😂
    Fantastic video as always Gaz
    👍👍👍👍❤️

  • @andrewdavis2443
    @andrewdavis2443 Před 2 lety +2

    Great video and a very good idea. Can you show how to add a 2 way switch when feeding the switch? Thanks

    • @GSHElectrical
      @GSHElectrical  Před 2 lety +1

      Wiring Diagram Lighting Circuit 2 Plate Method Taking the Feed to the Switch - 2 Way Switching
      czcams.com/video/QX1B4gtqisc/video.html

    • @GSHElectrical
      @GSHElectrical  Před 2 lety +1

      Lighting Circuit 2 Plate Method How to Wire and Connect up 2 Way Switches (Connections Explained)
      czcams.com/video/zfsP-C7DjSo/video.html

  • @raychambers3646
    @raychambers3646 Před 2 lety +1

    Also handy to have 3 core when fitting an emergency fitting .

  • @adammccormick4852
    @adammccormick4852 Před 2 lety

    In a two way setup- for a smart switch- would you need a neutral at both switches?

  • @raj080288
    @raj080288 Před 9 měsíci

    How would you take the feed to another room from this futureproof setup? Do you just connect a twin and earth that goes into cpc, neutral and live?

  • @robertwilliamson3934
    @robertwilliamson3934 Před 2 lety +2

    It a good idea but in a time of trying to be Green should we be using more material than we need I think prob do it to random lights not all

  • @rajnirvan3336
    @rajnirvan3336 Před rokem

    When connecting both brown wires into common is it OK to us Wago 3 terminal with 2 connecting together and 1 wire into common

  • @ColinRichardson
    @ColinRichardson Před 2 lety

    It's there a clean way to extend the switching line to a 2nd light? Or just jam two blacks into a single rose connector?

  • @Harrycowlton
    @Harrycowlton Před 8 měsíci +1

    👍👍👍👍👍

  • @stevendouglas3860
    @stevendouglas3860 Před 2 lety +1

    Would you say Gaz ..3 core is best (for rewiring and adding lights to loft , outside lighting .

    • @GSHElectrical
      @GSHElectrical  Před 2 lety

      👍🏻 thanks for commenting

    • @stevendouglas3860
      @stevendouglas3860 Před 2 lety

      @@GSHElectrical is 3 the best for extending ....

    • @tobysherring1369
      @tobysherring1369 Před 2 lety +1

      @@stevendouglas3860 only in the circumstances in the video. You don't need more than 2-core+cpc until you want to switch something and either provide neutrals at the switch, or a permanent live in an accessible place for possible *future* expansion.

    • @stevendouglas3860
      @stevendouglas3860 Před 2 lety

      @@tobysherring1369 thanks 👍

  • @raj080288
    @raj080288 Před 4 měsíci

    How would this work with a 3 plate downlight in terms of wiring?

    • @GSHElectrical
      @GSHElectrical  Před 4 měsíci

      How to Future Proof Your Lighting Circuit with a Neutral at the Switch - 3 Plate Wiring Method
      czcams.com/video/1XcxdvFRyY0/video.html

    • @raj080288
      @raj080288 Před 4 měsíci

      @@GSHElectrical amazing! I did see this one but its referencing a pendent as opposed to a downlight where the connections differ between the two.

  • @chrisbaker1991
    @chrisbaker1991 Před 2 lety

    Meaning 3 cables in the permanent connection at the switch for the circuit

  • @BK-it6te
    @BK-it6te Před 2 lety

    Very good but you might never use it, the three core cable is quite expensive

  • @Pegaroo_
    @Pegaroo_ Před 2 lety

    Sounds a bit like a ring main but for lighting

    • @tobysherring1369
      @tobysherring1369 Před 2 lety +1

      Err, no. It's still radial. The point of a ring is there's no end point because you go from the last fitting/plate back to the CU. What's being suggested here is nothing like that.

    • @Pegaroo_
      @Pegaroo_ Před 2 lety

      @@tobysherring1369 Maybe it should be as you'll be adding more and more current the further you extend this

    • @tobysherring1369
      @tobysherring1369 Před 2 lety +1

      @@Pegaroo_ the current is limited by the cpd at the cu, and the cable is rated accordingly. If your radial lighting circuit is likely to draw something near 6A (well over 1kw) you shouldn't extend it but install a new one for the new area.

  • @isaacjohnson1734
    @isaacjohnson1734 Před 2 lety

    Can you explain the 2 plate method when the neutral is in the ceiling rose and not at the switch (run in pvc singles), I see this mainly in council houses.

    • @GSHElectrical
      @GSHElectrical  Před 2 lety

      Wiring Diagrams for Lighting and Motor Circuits
      czcams.com/play/PL2Ea5r9gxUUfm4SACOSOZigCeSxxC5xaO.html
      The above playlist may help

  • @jonathanrose456
    @jonathanrose456 Před 2 lety +2

    Try getting them to do it in 1.5mm2 6243Y rather than 1.0mm2 😂

  • @terryhutchinson6503
    @terryhutchinson6503 Před 2 lety

    A 3 core for every switch drop is gonna get pricey.

    • @GSHElectrical
      @GSHElectrical  Před 2 lety

      The most expensive cable is the one you forgot to install 👍🏻

    • @terryhutchinson6503
      @terryhutchinson6503 Před 2 lety

      @@GSHElectrical Thats what cable schedules are for.

    • @kierenparry1995
      @kierenparry1995 Před 8 měsíci

      You would need an extra neutral to go between two way lighting to have a neutral at each switch, your 3 core strapper wouldn’t have a neutral

    • @terryhutchinson6503
      @terryhutchinson6503 Před 8 měsíci

      Why would you want a neutral in a switch drop?@@kierenparry1995

  • @ronwharton086
    @ronwharton086 Před 2 lety

    If you can't work this out yourself don't open your tool box become a plaster

  • @JohnSmith-kb5ku
    @JohnSmith-kb5ku Před 2 lety

    Why? Why would we use an expensive resource like copper when we have switches that like Quinetic and use another piece of copper when they aren’t required in the first instance.
    Nobody future proofs when technology is moving fast.
    Economic efficiency will mean switch wires go the way of the dodo. Even Ethernet cables and PoE could provide a solution.
    Just think of the savings and decorations from not using switch wires. They even do smart switches that don’t require a neutral.
    Everything is becoming more modular and easier to install too. Lower power, less resources are the future. People in the industry need to be aware and BMS system will become more prevalent in houses as products get cheaper and more reliable.

    • @GSHElectrical
      @GSHElectrical  Před 2 lety

      Thanks for taking the time to share your thoughts

  • @davidclarke2513
    @davidclarke2513 Před 5 měsíci

    Every sparks worth his salt knows that the best place to find a permanent line is in the floorboards or roof space ,in running in a 3 core from the light to the switch is ridiculous because you are just adding connections to the circuits,in my long 50 year career as an Industrial sparks it was frowned apon to have connector blocks inside switches,so what is the point of this new system,answer nothing but adding loose connectors to your circuit and making switch boxes having to be deeper to take these connectors,if you believe in this system compared to the 3 plate system then you astound me