Disconnecting protective conductors and false results when testing

Sdílet
Vložit
  • čas přidán 4. 09. 2024
  • When testing Ze we need to confirm the earth fault loop impedance.
    Incorrect disconnection of protective conductors can give us false results.

Komentáře • 17

  • @AlexJoker-mr9sf
    @AlexJoker-mr9sf Před měsícem +1

    "I love your video, to be honest. I'm just finishing my level 2, but I'm beyond advanced because of your videos."

  • @no_short_circuit
    @no_short_circuit Před měsícem

    Thanks again for explaining a complicated (and sometimes not properly understood) subject. Your use of graphics helps a great deal.

  • @jchidley
    @jchidley Před měsícem +1

    Another excellent video, from a chap round the corner from where I live.

  • @quinsboy7578
    @quinsboy7578 Před měsícem

    Very good....ideal for new/ inexperienced and great reminder for those who need a refresh 😊

  • @danielteyehuago1633
    @danielteyehuago1633 Před měsícem +1

    My favorite channel

  • @protectiongeek
    @protectiongeek Před měsícem

    Excellent video, thank you. It's clear you've spent a lot of time preparing such detailed graphics. I was wondering if you might mention something about checking for diverted neutral current on TN-C-S supplies before disconnecting the main earth from the MET, but perhaps you'll deal with that in a separate video. [Edit - and of course, you already have! CZcams just suggested that video to me]

  • @cfgman1
    @cfgman1 Před měsícem

    Excellent video.
    Parallel paths in EICRs is not well understood. A couple of really good shorts by "Mainly Electrical" have highlighted this.

    • @JPElectric
      @JPElectric  Před měsícem

      Thanks cfgman1, I will have a look at the shorts you suggest

  • @HeathenGeek
    @HeathenGeek Před měsícem

    great presentation 🙂

  • @freezefoot
    @freezefoot Před měsícem

    Thank you for this Ze tutorial."Artificial Neutral" @ 4:10 is a new term for me (googled it and got a lot of rocket science. Is their perhaps an easy definition?).Similarly never heard of Earth Marshalling Bar...Everyday’s a school day.Look forward to checking out
    your new Instagram page👍

    • @JPElectric
      @JPElectric  Před měsícem

      Thanks very much freezefoot. Re the artificial neutral, its something I need work on🙂
      The earth marshalling bar, is something thats not mentioned much. Its used in guidance note 8 earthing and bonding. Actually they call it a earth marshalling terminal

    • @freezefoot
      @freezefoot Před měsícem

      @@JPElectric Thanks JP👍

  • @danielteyehuago1633
    @danielteyehuago1633 Před měsícem

    I am first here