TRUE STAND UP FREEZER MAKING A WEIRD NOISE

Sdílet
Vložit
  • čas přidán 9. 07. 2024
  • The customer called complaining about a weird noise from their freezer, as usual it turned into a thing.
    HVACR VIDEOS NEW MERCH WEBSITE - www.hvacrvideos.com
    NEW HVACR TOOLS CHANNEL- / @hvacrtools
    Please consider supporting my channel by
    Becoming a Patreon member - Patreon / hvacrvideos
    Becoming a CZcams channel member / @hvacrvideos
    By purchasing tools via my affiliate links below at TRUTECHTOOLS.COM and use the offer code BIGPICTURE to save 8% on your total purchase (exclusions apply)
    Visiting my website and purchasing merch www.hvacrvideos.com
    HVAC OVERTIME CHANNEL LINK - / hvacovertime
    TOOL LINKS
    Fieldpiece MG44 micron gauge- www.trutechtools.com/fieldpie...
    Fieldpiece 10 cfm vacuum pump - www.trutechtools.com/fieldpie...
    Fieldpiece Infrared leak detector- www.trutechtools.com/fieldpie...
    Fieldpiece Large wireless pipe clamp- www.trutechtools.com/fieldpie...
    Viper hand pump sprayer - www.trutechtools.com/viper-2-...
    JB nitrogen purging adapter- amzn.to/3iwzaxc
    Ratchet tubing bender- www.trutechtools.com/BlackMax...
    Fieldpiece wireless scale www.trutechtools.com/SRS3?aff...
    Fieldpiece SC480 meter www.trutechtools.com/Fieldpie...
    Fieldpiece JobLink wireless probes www.trutechtools.com/JL3KH6?a...
    Sman 480 digital manifold www.trutechtools.com/Fieldpie...
    Fieldpiece MR45 recovery machine www.trutechtools.com/Fieldpie...
    Fieldpiece VP85 vacuum pump- www.trutechtools.com/Fieldpie...
    Wireless probes charging tee - www.trutechtools.com/AVT45?af...
    Samsung 8" Tablet amzn.to/3bW8QJ6
    OtterBox case amzn.to/2wgd0M5
    Bomber safety glasses - amzn.to/2yD6sbs
    Bomber safety sunglasses- amzn.to/2zmhdPp
    BlueVac Pro micron gauge - www.trutechtools.com/BluvacPr...
    TruBlu pro evacuation kit - www.trutechtools.com/Accutool...
    Accutools core removal tools - www.trutechtools.com/Accutool...
    Nitrogen purging regulator - www.trutechtools.com/Western-...
    Nylog blue - www.trutechtools.com/RT201B?a...
    Flir One Pro thermal imaging camera www.trutechtools.com/FLIR-One...
    Viper coil gun- www.trutechtools.com/Refriger...
    Viper Condenser coil cleaner Venom Pack- www.trutechtools.com/Viper-Ve...
    For Optimizing my videos I use Tube Buddy
    www.tubebuddy.com/HVACRVIDEOS
    Please consider subscribing to my channel and turning on the notification bell by clicking this link goo.gl/H4Nvob
    BRAZING MONTAGE MUSIC - YOUNG AGAIN BY LUPUS NOCTE
    Social Media
    Facebook / hvacr-videos. .
    Instagram / hvacrvideos
    For any inquiries please contact me at chris@hvacrvideos.com
    Mailing Address
    HVACR VIDEOS
    12523 LIMONITE AVE.
    440 - 184
    MIRA LOMA, CA. 91752
    00:00 TEASER
    00:40 SPONSOR CARD
    01:06 THINK SMART
    01:58 IT WON'T RESPOND
    02:45 TEMP CONTROL PART NUMBER
    05:00 WE ARE BACK
    05:28 DID YOU KNOW??
    06:44 THINK BIG PICTURE
    09:48 SENSOR SPLICING
    11:07 WTF MOMENT
    12:55 SKETCHY PINCH PROCESS
    15:41 ALWAYS CHECK FOR LEAKS
    19:56 FOUND THEM
    23:02 BRAZING WITH NITROGEN PROBLEM
    23:41 BRAZING MONTAGE
    27:25 EVACUATION TIME
    33:53 CLOSING WORDS

Komentáře • 225

  • @gyrgrls
    @gyrgrls Před 2 lety +5

    R290 is an excellent refrigerant. It's nice to see that it is being accepted again in the USA. I used to run 290 in systems I built using R22 compressors about 30 years ago. But I was building dehumidifiers for lumber dry kilns in northern California in the early 1990s. Worked with R12, too before it was banned. R290 is almost a direct drop-in replacement for R22. It's good to see that flammable refrigerants are making a comeback. On larger systems, I was forced to use R22, due to fire regulations. But that was back in the 1990s... when R290 was still illegal in many areas.

  • @RobertLanghorn
    @RobertLanghorn Před 2 lety +77

    I specialize in small appliance refrigeration. I really like watching your videos. I love how meticulous you are. I technician the same way. A few tips. Yellow jacket makes a special manifold for R-290a with awesome colored 2mmID hoses (41868). Use a lab grade microgram scale for your R-290a. I also use an Accutools S10767 right on the refrigerant canister so I can turn it off right on the scale. I put another two S10767 on my core tools so I don't lose anything. TruBlu evacuation, attach manifold to core tool side ports, close pump, charge into the high side, start the compressor, home stretch into the low side leaving room for what's left in the hose leading to the refrigerant canister. Shut the can off on the scale. Let the last 0.04oz out of the refrigerant line. Then insert the high side shrader core and clear my hoses. I can consistently meet the exact charge weight every time. You've taught me so much, I hope this helps.

    • @REFRITEKREFRIGERACION
      @REFRITEKREFRIGERACION Před 2 lety +5

      I have not work on R-290a system yet, but nice tips. Thanks

    • @seanmichael8202
      @seanmichael8202 Před 2 lety +7

      Gotta hand it to you. I’ve grown to loath small systems like these. Super critical charges, cap tubes, tight spaces, all the abuse they take... I work on the opposite side of the spectrum in system size, so it makes it worse when I get calls out to systems with only a few lbs or less 🤣 I like working on the huge systems, but I have massive respect for anyone who is skilled with any system, giant or tiny. Sounds like you know wha you’re doing, my friend 🤙 Kudos

    • @gyrgrls
      @gyrgrls Před 2 lety

      The exact charge is not so much of a big deal in systems with liquid receivers. In small cap-tube units, it gets a little hairy. But propane is an excellent refrigerant. I used to use it in lumber dry kiln dehumidifiers in place of R22. Gotta change the oil, though...

    • @fitybux4664
      @fitybux4664 Před rokem

      Would a piercing valve be a better choice for adding a temporary service port on these small appliances instead of brazing on a whole new port and chopping it off every time? 😆

  • @htroberts
    @htroberts Před 2 lety +45

    I hope that was a warranty repair. Evaporator, control, and three visits have to be close to the cost of a new unit.

  • @DocNo27
    @DocNo27 Před 2 lety +25

    Smiled when you re-did the service ports and removed the crimps. Hope your customers appreciate the attention to detail you and your crews display!

  • @sonjagiljaca6555
    @sonjagiljaca6555 Před rokem +3

    It was very interesting because that r290(propane) system had two leaks. First in the evap coil then on that coiled discharge line in the drain pan. I watch your videos and they are awesome. I work on big refrigeration systems using r404a, but then I also work on household refrigerators which use isobutane(r600a) and most of them have leaks where cap tube enters the evap coil. Your sporlan's flare dryers and sight glasses are awesome, also sporlan's solenoid magnets and expansion valves are awesome too.

  • @lutboy2909
    @lutboy2909 Před 2 lety +4

    Dude a small trick for the condenser drain Heater i learn on the imbera fridge workshop, they put Heat shrink on the coper line, and that help you a lot with the corrosion by water or any fluid in it also still transfer the heat to the water, isn't like proof of leaking but at least make it last more without leaks

  • @christiansarkisian5820
    @christiansarkisian5820 Před 2 lety +21

    Hey Chris. Saw you on the 60 the other morning with my coworker! That was me who said what’s up in the stake bed. We were on our way out to build a little reach in cooler. Keep it up with the videos bro! You’ve taught me a lot!!

  • @seanmichael8202
    @seanmichael8202 Před 2 lety +2

    Dude, this is why I got the Inficon D-Tek Stratus... I’ve had the Fieldpiece and the TIF, which I know some people swear by, and that’s cool for them. But, I’ve had soooo many headaches with feeling ABSOLUTELY sure there’s a leak where it goes off, and then it disappears, reappears, kinda beeps... You throw some bubbles on it, and nothin’. Once I bucked up and paid for the Stratus, I haven’t once regretted it. I’ve found some of the smallest leaks just doing CARB audits on racks, and was actually recently called out to follow up on a milling machine chiller because the initial tech’s leak detector was messin’ him up (had to go all the way to Santa Clarita from Running Springs for that one 🤦🏼‍♂️), but I totally understood his plight, and frankly, that’s the only time I wish I didn’t have such a legit leak detector. Found the leak within 5 minutes of looking. My supervisor was like, “You got the Stratus, right?” Which was ultimately why I got sent to that one... haha... Anyway, I thought I remember one of your videos where you had one. Maybe I’m trippin’. In any case, Inficon Stratus is the best leak detector I’ve ever used. Awesome vid, as usual 🤙

  • @bradknick4220
    @bradknick4220 Před 2 lety +32

    I am not in the industry, but I enjoy watching...I have learned so much...even noticing the WAGO connectors in this unit...keep being awesome.

    • @glenjones4404
      @glenjones4404 Před měsícem

      An expensive repair as you have nearly changed a good half of the fridge freezer sys
      tem 😂

  • @wolphin732
    @wolphin732 Před 2 lety +24

    For the sensor replacement splicing... I would suggest you get phone splice connectors, and get the wet environment ones that are gel filled, as they are designed to splice low voltage thin wires and be in hostile environments without much monitoring.

    • @petersmart1999
      @petersmart1999 Před 2 lety +3

      Yes ,the ur and s.u.r connectors,also the gray ones for 22-26awg,pretty much good for submersion .

  • @mwiz100
    @mwiz100 Před 2 lety +6

    It may have been hard to see on site but the second service port you could actually see it leaking. Much like the ripples you see over a candle the same thing happens with leaking refridgerants or the like - that gas has a different density which causes the refraction of the light and you see it as that "wiggling" of the air. I was able to spot it on the second one because the camera angle was just right.

  • @fer.g.4319
    @fer.g.4319 Před rokem +2

    You're really good at explaining things to new techs and costumers and that's not easy to do and definitely I need to work on that... thanks for all your videos they help a lot

  • @theberrybest
    @theberrybest Před rokem

    Communication is key. I'm enjoying these vids.

  • @chris76-01
    @chris76-01 Před 2 lety +18

    Instead of using butt connectors, you can use the jelly bean connectors like they use with telephone wires.
    They're designed for small gauge wires and are waterproof. 👍

    • @petersmart1999
      @petersmart1999 Před 2 lety +8

      Absolutely,I am an Hvac mechanic for a very large communication company,and when in doubt we use the 3m scotchlok connectors,UR,S-UR,reds orand and the grays

    • @HVACRVIDEOS
      @HVACRVIDEOS  Před 2 lety +10

      I'm gonna order some of those !! Thanks guys

    • @74FirefighterEMT
      @74FirefighterEMT Před 2 lety +1

      @m9 ovich butt connectors are not rated for solid conductors, they are ONLY rated for stranded conductors.

    • @edswider9309
      @edswider9309 Před 6 měsíci

      No stay with solder and shrink tube

  • @smokemadbuds991
    @smokemadbuds991 Před 2 lety +3

    seriously love your videos, after a long hard day of service work nothing beats this. no lie.

  • @Goldstacker1972-kp2bh
    @Goldstacker1972-kp2bh Před 4 měsíci +1

    Marine connectors work good for sensors. They're like a butt connector that you put the wires in and they have solder in them. You use a lighter and it melts the solder and the outside of the connector is heat shrink so you get a good connection.

  • @YuShudNoe
    @YuShudNoe Před 2 lety +2

    That screw from the door reminded me of that scene from The Breakfast Club 😂

  • @fitybux4664
    @fitybux4664 Před rokem

    "Let me just pull everything out of your freezer and rebuild it." LOL. 😆 (Well, I guess the compressor and fan motor got to stay.)

  • @hmrody
    @hmrody Před rokem +2

    I saw something interesting about 8:33+. One on the Wago connector's levers was raised slightly. I saw another video recently that as standard practice, wrap the connectors with electrical tape to prevent a problem if a lever gets bumped and raised. Wago's are good connectors, but possibly they need to have a bit more "click" when closing. Just a thought...

    • @hmrody
      @hmrody Před rokem

      You are kind. I really like what you are doing. I understand that you started the channel as a way to train employees, but it is doing so much more. Thank you!

  • @roseanncloskey
    @roseanncloskey Před rokem +1

    Excellent Trouble Shooting and repairs, 1/22 /2023yr

  • @edswider9309
    @edswider9309 Před 6 měsíci +2

    You made a bundle on the reachin new evap new heater no call back nice

  • @SidebandSamurai
    @SidebandSamurai Před 2 lety +2

    A recommendation (of course what do I know about refrigeration because I don't) I would make because you are dealing with high humid / water areas, you could use the butt splices that are impregned with dielectric grease which further seals the connection from water/moisture. The shrink tube is a great method though.

  • @kfl611
    @kfl611 Před 2 lety +1

    You are so knowledgeable ! And explain things so well.

  • @terrygrant8126
    @terrygrant8126 Před 2 lety +2

    Well done my friend!.....that was my first time seeing pinch-off tools....

  • @bradsmith9293
    @bradsmith9293 Před 2 lety +4

    Could have sworn I saw some bubbles when leak checking condensate coil WHILE IT WAS IN WATER. Go back and have a look see.

  • @jamestoy426
    @jamestoy426 Před rokem +1

    I always learn from your videos

  • @birknerjohn
    @birknerjohn Před 2 lety

    Love the videos, Chris! I watch all of your videos and strongly encourage all my younger techs to do the same, great work!

  • @chadhartsees
    @chadhartsees Před rokem

    That condensation evaporator loop is pretty clever.

  • @joseamaya1906
    @joseamaya1906 Před 2 lety

    thanks for everything you do! I'm learning new tricks from your videos.

  • @victoruribe885
    @victoruribe885 Před 2 lety +2

    My God. finally an HVACR video. You could make a retro video of what tools you started with and make a comparison to the new stock. Piz Out Chris! from Chile.

  • @kyberking
    @kyberking Před 11 měsíci

    Nice work! I hate the crimp tool, just slap a pierce valve on it pull a vac after the dump and get it to boil off and never had an issue, i like to add way more discharge loop to it and help these little cu's out, filling the pan with water and pressure check is how i find these, true are the good ones to work on, your doing the trade a favor posting these, thank you sir!

  • @jaysonhines1
    @jaysonhines1 Před 2 lety

    That was awesome. Thanks Chris.

  • @georgevillazana8378
    @georgevillazana8378 Před 2 lety

    Great video. i enjoyed it while drinking a beer on a Friday night, and learned about the hot gas condensate heater, thanks for your videos!

  • @rios7916
    @rios7916 Před 2 lety +1

    Great video Chris, thank you so much

  • @tristanhameleers7506
    @tristanhameleers7506 Před 2 lety +2

    5:25 nice that there are still good company's that try to make everything as easy as possible.

  • @aperdue100
    @aperdue100 Před 2 lety

    Thxs for the great video. Learning all I can for r290.

  • @demonknight7965
    @demonknight7965 Před 2 lety

    Some of the best advice for any industry. CYA!!!

  • @metalfusion67
    @metalfusion67 Před 2 lety +1

    professional explanation all the way thru. Keep up the great work. A+++

  • @MikeB9771
    @MikeB9771 Před 2 lety

    Love these videos, this is the equivalent I work on all this stuff.

  • @JaegerWrenching
    @JaegerWrenching Před 2 lety +2

    I'm surprised I don't see you use a thermal imaging unit more often to view the temp of multiple things simultaneously like evaporators for even cooling across them and so forth. I think they are very underrated when things are going wrong and i'm scratching my head trying to figure it out lol.

  • @ZeroStatic
    @ZeroStatic Před 2 lety

    Thanks for another great video Chris. 👍

  • @k4vms
    @k4vms Před 2 lety

    FYI - Instead of bending these wires over to increase the bulk of the wire a best pratice would be to tin those wires then put the butt connectors on. This will give you a much more reliable mechanical and electrical connection not to mention. I am not an HVAC person just an engineer.
    Ricky from IBM, Ret

  • @nsaglian
    @nsaglian Před 2 lety +2

    Thanks for a another great video! With the extra bonus of brazing montage music!

  • @edswider9309
    @edswider9309 Před 6 měsíci +1

    Chris the restaurant work is the toughest

  • @aungthiha5050
    @aungthiha5050 Před 2 lety

    When the music come, i realized that what a perfect video

  • @vlfreak
    @vlfreak Před 2 lety

    cheers for the content man 👍🍻

  • @Ted_E_Bear
    @Ted_E_Bear Před 2 lety +1

    Great video Chris !

  • @jonathanlanglois2742
    @jonathanlanglois2742 Před 2 lety +3

    15:50 even as you say "we'll do a test to say if it is sealed", the gas escaping is clear as day. Might not have been visible from your perspective, but your camera sure caught that.

  • @oneeye1960
    @oneeye1960 Před 2 lety

    It’s a crying shame True puts out a pile of garbage like that! I bet your poor customer put out $2000 to fix that pile of crap. Those fancy control modules are junk they should have never gotten away from the dial temp control and a $100 defrost timer. I know the battle when you have several problems at once it always seems the customer never understand this. Keep up the good content!

  • @deanmohamed7575
    @deanmohamed7575 Před 2 lety

    my man Chris brazing upside down so that we can see his work. Good to see you are still pumping away. you tube stopped promoting your videos to me.

  • @DWAYNE2ism
    @DWAYNE2ism Před 2 lety +1

    great info

  • @macabre19
    @macabre19 Před 2 lety

    Great video. Small refrigerators/ freezers are tough.

  • @thesilentonevictor
    @thesilentonevictor Před 2 lety

    Clean job Chris 👌

  • @anthonywoolf9087
    @anthonywoolf9087 Před 2 lety

    Nice video love watching

  • @EdOlivett1
    @EdOlivett1 Před 2 lety +1

    Get some solder sleeves for those small wires! Way better than butt connectors!

  • @oscarpineda8360
    @oscarpineda8360 Před rokem +1

    Hello Cris my name is Oscar Pineda from Honduras I really like the videos I thank you for the effort you make I would like a video of the electrical circuits of a culler on how to install it grace

  • @ignacio9399
    @ignacio9399 Před 2 lety

    Thing nice thing about True is that they have great tech support. Those guys will pretty much diagnose it for you over the phone if you're ever unsure.

  • @Brokenwings1962
    @Brokenwings1962 Před rokem

    Love your videos. I used to be a maintenance HVAC supervisor for a retirement village. We did splits and package units as well as geothermal and fan coil systems as well as the boiler and chiller. Do you ever do videos about those ??

  • @falloutguy8878
    @falloutguy8878 Před 2 lety

    Great video Chris thank you for sharing it was very interesting and impressive your the man dude? Have a great day dude

  • @panagiotispsomas5611
    @panagiotispsomas5611 Před 2 lety

    This expansion cable are for temperature recorder if the customer wants to record the temperature over the internet you have to use RS232 to RS485 with lae recorder

  • @shawns6135
    @shawns6135 Před 2 lety

    Love the videos bud. I know they say r290 when working properly should drop a degree a minute. I love how clean you did the wiring! I started using the vice-grip access valves. I also switched to the mastercool r290 - r600 scale. It’s a great scale.
    Have you ever looked at subcooling when it comes to cap tubes? Keep up the good work!Awesome videos

  • @805HVACR
    @805HVACR Před 2 lety +3

    Use dolphin connectors for the small wire. I use those on all CPC and Danfoss sensors. Just a thought. Instead of butt-connectors

  • @johnwalker890
    @johnwalker890 Před 2 lety

    Good job Chris.

  • @donhill3rd
    @donhill3rd Před 2 lety

    True had me affix a 1" piece of PVC to the back of the box and drill a hole in the box and run the wiring in the pipe... It worked...

  • @ReliableHVACR
    @ReliableHVACR Před 2 lety

    Nice! I used to work on true reach ins daily. They can be troublesome, the smaller they are.

  • @pedrojardim1163
    @pedrojardim1163 Před 2 lety

    Thanks. Chris. Aprociate cool. Video

  • @mark351
    @mark351 Před 2 lety +1

    At one point I said to myself, he's going back again!

  • @rickybobbyracing
    @rickybobbyracing Před 2 lety

    Chris, look into UY crimp connectors, that's all we use to splice in sensors, waterproof and cheap

  • @KingOfKYA
    @KingOfKYA Před 2 lety

    That serial port I would probably not be be too concerned those serial chips are generally have pretty good protections, often can handle kv of -or + surge voltage.

  • @bryanharayda1975
    @bryanharayda1975 Před 2 lety

    True has a 3 year P&L warranty and a 5 year compressor warranty. If the system runs in a vacuum within the first 5 years due to a Freon leak True will warranty the whole condenser skid. So that means new compressor, condenser coil and fan motor. Also, no paperwork to True for the parts, if it’s between 3-5 years old you don’t have to purchase the condenser section and then request credit, they just send you the whole thing

  • @jimharmon3404
    @jimharmon3404 Před rokem +1

    It makes you wonder what could be in that condensate water that it would corrode copper tubing like that. It kind of looks like the underside of salt belt cars here in Upstate NY. I think that maybe when these units are new that you could spray a bit of Fluid Film on that copper coil so it may never spring a leak. Since it works really well even on rust buckets it it would be wonderful in the environment at bottom of a fridge or freezer.

  • @elijahtalbot5288
    @elijahtalbot5288 Před 2 lety

    Nice video

  • @jasonjohnsonHVAC
    @jasonjohnsonHVAC Před 2 lety +1

    Brazing montage had little Beverly Hills Cop music in it. Get em Axel Foley. Lol

    • @josephconway1968
      @josephconway1968 Před 2 lety +1

      Ha! Ha! I was thinking 80's cinema soundtracks! Love the music he uses!😁

  • @manolotech1110
    @manolotech1110 Před 2 lety

    Hey Chris looks like you went all out on that little reach in. Kinda of like fishing for a minnow with a harpoon🙂. Lol. Guess if the customer is gonna pay, what the hell. Great vid as always.

  • @alouisschafer7212
    @alouisschafer7212 Před rokem

    Pretty cool that Propane is a good refrigerant gas.

  • @justtime6736
    @justtime6736 Před 2 lety

    23:41
    Loved the whole segment.

    • @justtime6736
      @justtime6736 Před 2 lety

      35:28
      Work-hardened copper, it's a bitch.

  • @shine-cg9uf
    @shine-cg9uf Před 2 lety

    Great video. Do digital controls take the place of 3 switch klixon ? Or will they have both digital control with a dtfd in evaporator section wired back to digital control ?

  • @jakem117
    @jakem117 Před rokem

    I bury those HGC loops in big blue and stare. Quickest and most reliable method IMO. It's messy though sometimes

  • @docmanx10
    @docmanx10 Před 2 lety

    I got that same true book
    2 years ago at kalos symposium

  • @seantubbs4694
    @seantubbs4694 Před 2 lety

    Have you ever used a steamer for clearing evaps? I do mostly residential and love mine. probably wouldn't work super well for walk ins, but for smaller reach ins, they make a lot less mess than a hose

  • @baelevatorsmore728
    @baelevatorsmore728 Před 2 lety

    We had a similar sounding fan in a True beverage display cooler at my work. As it turns out, the fan cover had been shoved up into the fan blade and it was chewing up the blades. Interestingly, it seems like these coolers are known for having their compressors fail if left unpowered for a period of time. I don’t know how many beverage coolers we’ve had dump all of their refrigerant out onto the floor. Quite the mess.

  • @realestateservicessaleshea99

    Thanks again for the videos!
    🥃🥃🍺🍺🍺🍿🎯🏌🏻‍♀️
    Stay safe.
    Retired (werk'n)keyboard super tech. Wear your safety glasses!

  • @RobertSzasz
    @RobertSzasz Před 2 lety

    I think Wago makes gel filled boxes you can close around their connectors now.

  • @Goldstacker1972-kp2bh
    @Goldstacker1972-kp2bh Před 4 měsíci +1

    I want 3 arms to work on stuff. Lol

  • @ErickHernandez93
    @ErickHernandez93 Před rokem +1

    Hey Chris hope all is well brother
    Wondering where did you get the support to gadget to hold the R290 can? I’m having to sit sideways & hold the hose so it doesn’t move with something heavy lol let me know if you have a link, thanks 🙏

  • @MariosACandRefrigeration
    @MariosACandRefrigeration Před 2 lety +1

    like you had mention before,pan must be dry or your pressures will be very low and it will cool slow.

  • @timballam3675
    @timballam3675 Před rokem

    We have freezers like this in the UK but it's always a replacement never a repair unless it's just the controller!

  • @robertpeters9438
    @robertpeters9438 Před 2 lety

    Try using the self sealing marine connectors for wires in these settings.

  • @k.sullivan6303
    @k.sullivan6303 Před 2 lety

    FYI... I think there are butt connectors that you can also insert solder into, or just heat them up and they have solder already in them. Maybe some shrink wrap afterward too.

  • @patrick12399
    @patrick12399 Před 2 lety +1

    You are seeing the propane leaking even before you hit it with the flame. This is called schlieren I think.

  • @fridgemanuk6696
    @fridgemanuk6696 Před 2 lety +1

    How would you bill this job mate?
    1st visit..callout + labour (1hr)
    2nd visit. Travel time + labour + parts
    3rd visit. Travel time + labour + parts
    It's the return on 2&3 I'm having problems asking for! I know the above happens as its happened with myself!

  • @dashcamandy2242
    @dashcamandy2242 Před 2 lety +1

    Kudos on your perseverance in tracking down those leaks!
    I've used a lot of True products over the years, I find them to be quite robust - especially in the abusive food service environment. I can't tell you how many times I get the "Andy, water is coming up through the floor under the Coke cooler again" complaint, where I have to educate my coworkers that there's this thing called a condensate pan, and when it's full and an employee jostles the cooler, the water spills over the side of the pan (and, during the humid summertime, the pan overflows daily anyway - there's nothing we can do about it but keep tabs on it and mop as needed). The water is NOT coming up through the floors!
    We have three separate spots where I hear the "water comes up through the floor, meaning the foundation is cracked" complaints, and I have to keep telling them, "LOOK UP!" The cause is always condensation on the A/C outlets or the leaking roof every time, and one might think that over 8 years of complaints about the roof leaking the property manager would do SOMETHING, but no, they won't even get up on the roof to mow the lawn. Yes, you read that right - we have a small garden of weeds growing on the roof. Someday I want to get up there to take a look at one of our exhaust hoods that isn't working, so I can tell Idiot With Toolbox to fix it. I don't know which unit(s) in the building, if any, have a roof hatch - if we had one, my nosy butt would have already scaled the ladder and poked around!
    Yesterday, when closing, one of the crew shut off the only working exhaust fan, and the manager (she's only been with us for 2 months) had no idea why the oven refused to turn on. I discovered by accident a week ago that the oven was disabled when the hood fan was off - something I picked up in one of Chris' previous videos, and luckily was able to pass on this bit of knowledge. She was a bit disappointed to find the solution was simple, meaning the oven will still not be fixed. I had to bake my croissants an extra 25 minutes today because the oven preferred to stay 100° or more below its setpoint. It was 125° low the other day, had to power-cycle it to make it work again. This is another problem that has existed since I last worked at this store 8 years ago.
    We bring in $200K of profit annually, can we maybe get the renovations we've been promised for over a decade? Or even just FIX OR REPLACE faulty equipment? Nope, we don't ABUSE the equipment, so therefore we must keep the dilapidated stuff we've been limping along with while the stores that destroy their equipment get NEW replacements. In my opinion, the stores that ruin brand new equipment should be forced to use the old stuff until they can prove they're willing to be a little more careful, and they should get the hand-me-downs from stores that take care of their equipment and deserve the latest and greatest...
    This is why I could never be in an Upper Management position, because I'd be treating staff that acted like irresponsible children in a manner fitting to their attitude.

  • @garypoplin4599
    @garypoplin4599 Před rokem +1

    30:55 - Your Fieldpiece app is screaming 2.00. Where are you seeing 2.08?!

  • @Georges3DPrinters
    @Georges3DPrinters Před 2 lety

    High pressure leaks can be fun.

  • @minigunnathaniel
    @minigunnathaniel Před 2 lety

    If you guys are wondering why it's flashing is because the camera shutter it keeps on shutting it shut so fast that it looks like it's flashing but in IRL it's not flashing

  • @DomManInT1
    @DomManInT1 Před 2 lety +1

    I do not pinch/unpinch. I evacuate the system and add the ports needed. To each their own I suppose.

  • @unacceptable6625
    @unacceptable6625 Před 2 lety +3

    I don't do refrigeration work, so I don't have experience on finding leaks with R-290, but I was curious if you ever used an ultrasonic on one of these reach-ins? I feel like it might have a little bit of an easier time picking up a squeal from a heat loop considering they work better on wet copper. I have an Accutrak GN that I use and so far I like it a lot better than the heated diodes that i've used in the past; for residential AC.

    • @grantkenney118
      @grantkenney118 Před 2 lety +2

      i use ultrasonic for leak finding but has its up and downs too especially background noises. its a great tool too have but not as clear cut as you may think. there is audio to visual device fluke ii900 that i would love to try but its 20k

  • @zacharysamenfeld2487
    @zacharysamenfeld2487 Před 2 lety

    So soft copper with the pinch off tool works a lot better. You can soften the copper by heating it red hot for a few seconds, at that point you can either cool it down with some water or just let it cool down naturally. The important part is just getting it red hot. Of course that's NOT something you wanna do with a charged 290 system so I'm not sure when this tip will ever be useful...

  • @hvactechpr7872
    @hvactechpr7872 Před 2 lety

    Nice video if that was here id do a a421 with a supco EDT 10...

  • @CyberlightFG
    @CyberlightFG Před 2 lety +1

    1000$ bill for a 3000$ freezer.