How to Perform Proper Annual Maintenance on Central AC Outdoor Condensing Unit

Sdílet
Vložit
  • čas přidán 22. 05. 2024
  • Are you an experienced HVAC tech or mechanically inclined homeowner? This step by step how to video is for YOU!
    Let's Make The Trades Great Again! Join Mikey Pipes Philanthropy, Inc., an IRS 501(c)(3) non-profit public charitable organization. Our mission is to offer free or low-cost plumbing, heating and cooling services to those in our community who can't afford to hire a professional. Help us here: www.paypal.com/donate/?hosted...
    Need a website for your contracting business? Check out Footbridge Media for their amazing special on not only a website but SEO services for only $249/month! www.footbridgemedia.com/?ref=...
    Need a CRM or dispatching and invoicing app? Check out HouseCallPro: tinyurl.com/MikeyPipesHCP
    What’s in your Veto? Here is mine:
    Veto TP-XXL amzn.to/3zX10vg
    Testo Combustion Analyzer: amzn.to/3Zd7naH
    Digital Manometer: amzn.to/3EDt5ey
    Milwaukee M18 Blower: amzn.to/46iTo6j
    Milwaukee M12 Fuel 1/4" Impact Driver amzn.to/3I9yLfI
    Milwaukee PVC cutter: amzn.to/3sbrdUc
    Mini Waterproof Storage bin: amzn.to/3yfgsEv
    Wiha Allen Keys: amzn.to/33ipGmb
    HIKMICRO B20 amzn.to/33iGklx
    Furnace Switch amzn.to/31X89PT
    Milwaukee Light amzn.to/3I38Lmh
    Wagos amzn.to/34QoiaU
    Milwaukee Set amzn.to/33vnQOz
    Torpedo Level amzn.to/3no1oOk
    Crescent set amzn.to/3GtZeV8
    Wiha 7 piece set amzn.to/3rkISaK
    Milwaukee step bit amzn.to/3I395Bv
    Thermocouple Flare wrench: amzn.to/3noJZ8s
    Ridgid 10” wrench amzn.to/3GvRnqa
    Fluke non-contact tester amzn.to/31VQgAQ
    Klein drivers amzn.to/3qoe21W
    Knipex Wrenches amzn.to/3trzFjS
    Klein 11-1 amzn.to/3tpsPLD
    12” crescent amzn.to/3A0CZ6S
    Gerber Gear Pocket Knife amzn.to/3foaW7I
    Yellow Jacket Hand Ratchet amzn.to/3nrDgup
    I am on Discord & WhatsApp!
    Discord: / discord
    WhatsApp Group: chat.whatsapp.com/CHZWtZe4KMG...
    New oval raised silver stickers are from:
    Armored Decal Company Inc.
    35 Victoria St. E, Unit 9
    Alliston, Ontario L9R 1T3
    (p) 705-435-6665
    (e) ken@armoreddecal.com
    (Tell them Mikey Pipes sent you)
    Please support this channel and Mikey Pipes and consider the following…
    Pipe Doctor FlexFit Embroidered Caps
    Minimum donation of $37 is appreciated
    (If you are international - please add a minimum of $40 for shipping/postage)
    Shopping on Amazon? Please use my referral link amzn.to/2PjjS4v
    Sticker Requests:
    Do you want a sticker to show your support of this channel? Email your request to me! mike@mikeypipes.com
    Name
    Address
    City, State, Zip
    Consider making a donation of $5.00, or ANY amount, to the postage fund! I literally mail out stickers all over the globe. I've sent stickers to HVAC guys in Afghanistan, New Zealand & all over Europe.
    PayPal is: office@pipedoc.net
    Venmo: @PipeDoctor
    CashApp: $mikeypipesny
    Zelle: mike@mikeypipes.com
    Want to send a love letter, note or gift? Our mailing address is:
    Mikey Pipes, Inc.
    1010 Central Avenue
    Woodmere, NY 11598
    #hvac #mikeypipes #pipedoctor
    Music from #InAudio: inaudio.org/
    Other music from MOVAVI STUDIO SUITE 2024 under license by 3:10 Global Holding, Inc.
  • Jak na to + styl

Komentáře • 93

  • @russellhill5959
    @russellhill5959 Před 2 měsíci +3

    Might be a good idea to mount the Air cooled condenser starter capacitor upside down so that moisture doesn't accumulate in the bath tub top configuration when pointing up if connected wiring is long enough to allow you to reorient pointng down. Noticed the top of the capacitors were very rusty and tested good. Salty air environments rust everything. It's in a sealed compartment but doesn't keep out condensation and bug debris. Just a suggestion when doing maintenance. I really enjoy your channel. NJ Jersey Russ

  • @johnwalker890
    @johnwalker890 Před 2 měsíci +4

    Good job Mike...... You caught the sloppy work on the disconnect feeder.......

  • @danpresson
    @danpresson Před 2 měsíci +2

    Great job Mikey pipes

  • @stephenzies8867
    @stephenzies8867 Před 2 měsíci +1

    Mr. D You Are A True Professional 👍

  • @mannyhendrix1
    @mannyhendrix1 Před 2 měsíci +1

    So much information in this video really makes it easier to understand the usual difficult part of checking pressures 🙏❤️‍🔥

    • @PipeDoctor
      @PipeDoctor  Před 2 měsíci +1

      Glad it was helpful!

    • @numchux2
      @numchux2 Před 2 měsíci

      there's always more to it, remember your ABC's! (airflow before charge)

  • @dkinfishing
    @dkinfishing Před 2 měsíci

    I appreciate this video a lot Mikey! Your making me a better tech, my company is pretty thorough, but man you do a damn good maintenance 🤟🏾👏🏾

  • @TomHolcombe-fh1kv
    @TomHolcombe-fh1kv Před 2 měsíci

    Thanks for recommending that meter I bought one in great. I love it even though I don’t you do Service work anymore but it’s great when I have to diagnose something after Install.

  • @brikaf6001
    @brikaf6001 Před 2 měsíci +1

    excellent vid, thanks mikey!

  • @wilmer23340
    @wilmer23340 Před 2 měsíci

    Good job I love watching your videos
    Some important information I have been working for about 15 years for a company that is married to Lennox and we have many problems with the evaporators coils due to the tremendous leaks they cause. I know that all evaporators usually leak liquid but the ones manufactured by Lennox are still of poor quality. I have not repaired the ones they sell made of aluminum, so when they are low on refrigerant, pay attention to the evaporator coils Lennox gives a 10-year warranty on the evaporator and is not responsible for labor or Freon.

  • @wolfy33789
    @wolfy33789 Před 2 měsíci +1

    With those thermostats and returns so close together they might as well have twinned the systems together as one big system.

  • @user-zi9ww5mt5s
    @user-zi9ww5mt5s Před 2 měsíci +1

    This is the best step by step video i have seen on how to perform maintenance to a condenser unit. I hope you are able to do the same thing for the air handler straight cool system, it will be very beneficial. Mikey, does a 10 year warranty covers coil damage due to gulf salt exposure?
    You mentioned making observations if your audience could see anything you could do better? I liked your safety approach with how to disconnect power with your left hand behind your back, but by the same token you are wearing a metal bracelet (is not plastic) on your right wrist. This is an osha violation for any person doing some sort of electrical work.
    Other than that, you are very professional outspoken individual for the trade.

    • @numchux2
      @numchux2 Před 2 měsíci

      it is probably not manufacturer warranty, but maybe under home warranty

  • @bagtube
    @bagtube Před 2 měsíci +1

    Because it’s Closer to the ocean. That had me laughing. 😂

    • @gtpforever
      @gtpforever Před 2 měsíci

      Why?

    • @bagtube
      @bagtube Před měsícem

      @@gtpforever Not sure must have been the gummies. LOL! I think my mind went that one unit was closer to the ocean and it was falling apart faster.

  • @AdamTrailglider
    @AdamTrailglider Před 2 měsíci

    Great information, Mike, and very clear explanations. Question: Since you had to add a small amount of refrigerant and you suspected a small leak somewhere in the system, would you proactively add some Easy Seal to try and solve the leak? Thanks!

  • @nickcangelosi1836
    @nickcangelosi1836 Před 2 měsíci

    This was very in detail and great for learning. The right tools for the right job makes all the difference in the whole world. What year were those? Luv the STIKA but where’s the FILTA?

  • @soldadosdejesucristo5280
    @soldadosdejesucristo5280 Před 2 měsíci +1

    El mejor

  • @mitchdenner9743
    @mitchdenner9743 Před 2 měsíci

    Looks dam thorough to me. Man, those fins were crumbling like a vanilla wafer.😮 so the subcooling happening in the evaporator is the temputure in degrees lower than the saturation point of the refrigerant ? And that basically accounts for the heat load in the house?

  • @scottvolage1752
    @scottvolage1752 Před 2 měsíci +2

    #1 Make the trades great again Mikey Pipes. #LoveBosch Smash that Like Button and Subscribe.

  • @Ryan-RM
    @Ryan-RM Před 2 měsíci +1

    Hi Mike, for the faded label do you know about the highlighting the faded area with a maker/pencil or flashing a flashlight over the label tricks so that you can read it? Good video!

    • @PipeDoctor
      @PipeDoctor  Před 2 měsíci +1

      Not that I know of, good tip

  • @throttlebottle5906
    @throttlebottle5906 Před 2 měsíci

    14:34 that would be ok, "if it was an outdoor sub panel" with four or more breaker spaces, holding two "two pole breakers" one per unit(as the disconnect). the wire appears to be 8-3 or 6-3 with ground. I'm guessing it was right with an outdoor sub panel at one point, then the hacks came along. 😉

  • @molk17
    @molk17 Před měsícem

    How do these coils get mangled? They are so well protected. What affects them, and how can you protect them even better?

  • @butchiemcginnis
    @butchiemcginnis Před 2 měsíci +2

    Am I wrong in believing that a single pole contactor only breaks 1 line going to the unit, leaving the other line always providing 120 volts ?

  • @robertlamey7612
    @robertlamey7612 Před 2 měsíci

    I like testing the caps under load

  • @jesseflory9910
    @jesseflory9910 Před 2 měsíci

    Do you ever spray anything like corrosion block on the connections in your maintenance?

  • @brian2359
    @brian2359 Před 2 měsíci +1

    Every year it surprises me how bad the ocean eats those condensors!

    • @PipeDoctor
      @PipeDoctor  Před 2 měsíci

      Crazy. Salt. Air. Death. 💀

  • @HonchHeado
    @HonchHeado Před 2 měsíci

    17:56 you said my testo wireless temperature probes to read my suction discharge pressures 🤣😂

  • @markeckman3662
    @markeckman3662 Před 2 měsíci

    Question - Why don't you use a protective coating to prevent corrosion on those terminals? We do it with car batteries

  • @numchux2
    @numchux2 Před 2 měsíci

    I bet someone checked the charge at some point after it was installed with the coils plugged up, and it probably showed correct subcool at the time

  • @russellhill5959
    @russellhill5959 Před 2 měsíci

    Which HVAC system do you prefer. Carrier Infinity or Bosch 2.0? Seems that Infinity has a larger remote air-cooled condenser.

  • @bernardaflores1720
    @bernardaflores1720 Před 2 měsíci

    Great job. To minimize the amps pull at start up, will it help if you put a starting capacitor to minimize amps pull

  • @TomHolcombe-fh1kv
    @TomHolcombe-fh1kv Před 2 měsíci

    Here in Seattle, we always put vinyl on the exposed line sets that comes out of line hide but I see no vinyl ever on your stuff in Florida or New York. You should think about getting some vinyl.

  • @chuckq54
    @chuckq54 Před 2 měsíci +1

    Why can’t the factory mount the info sticker on the inside of the contactor cover plate with other decals

    • @markcotter2355
      @markcotter2355 Před 2 měsíci

      There are stickers inside to read the model numbers

  • @justinhayward5027
    @justinhayward5027 Před 2 měsíci

    👍

  • @TomHolcombe-fh1kv
    @TomHolcombe-fh1kv Před 2 měsíci

    Mikey, do you use nylok on the service port caps when you put them back on

  • @markcotter2355
    @markcotter2355 Před 2 měsíci

    It is a Lennox so you know its low. Looked like both units were low. Did you charge both?

  • @TomHolcombe-fh1kv
    @TomHolcombe-fh1kv Před 2 měsíci +1

    Had to clean a coil like that I’m outdoor unit because you’re afraid you’ll take some of the aluminum bins away when you clean it but what do you have as an option? Nothing you got to

  • @brianholle9498
    @brianholle9498 Před 2 měsíci

    I've always added R-410A to a system with the bottle upside down. This is because it's a blended refrigerant and it ensures the two are mixed properly. Am I wrong?

    • @throttlebottle5906
      @throttlebottle5906 Před 2 měsíci

      that's the right way to do ALL blended refrigerants, inverted bottle drawn off as liquid. of course you have to throttle it down so it flashes to gas as it enters the system, don't want to feed the compressor liquid! you can do the initial charge with system "off" as straight liquid, generally into the high side only, unless there's a receiver tank, as you still do not want to flood the compressor, possibly pushing oil out or leaving it full of liquid.
      single component refrigerants can be charged gas or liquid, since there's nothing to keep blended.

    • @throttlebottle5906
      @throttlebottle5906 Před 2 měsíci

      whoops, to be clear, he did "flip the tank over and reset the scale weight" just before adding charge. forgot to say that.

  • @BlahBlah-em2ed
    @BlahBlah-em2ed Před 2 měsíci

    Someone missed the rally in the Bronx

  • @scottmaz4063
    @scottmaz4063 Před 2 měsíci +2

    #2 hay Scott v

  • @MarkNehemiah
    @MarkNehemiah Před 2 měsíci

    Has anyone ever worked on a concord? They are supposedly made by Lennox. I had a forced air heating and air concord system for 18 years in my last house. Went through 2 or 3 control boards, capacitors, was not reliable. It never leaked though and it was a R12 unit. The people that bought the house installed a carrier 😂

  • @spyder1125
    @spyder1125 Před 2 měsíci

    Trane or Carrier?

  • @steveg5576
    @steveg5576 Před 2 měsíci

    Anybody know what those large gray units with the heavy duty round switch -- above the horiz elec duct on the wall are ?

  • @suecrets5169
    @suecrets5169 Před 2 měsíci +6

    Lennox crap worst system ever, been a nightmare for 15 years. Leaks and coils get dirty so quickly. Bosch or Split system next time.

    • @PipeDoctor
      @PipeDoctor  Před 2 měsíci

      Yup 👍

    • @banderson5144
      @banderson5144 Před 2 měsíci

      When you're that close to the ocean, does rinsing the coil once a week help at all or will it still corrode regardless

    • @jhimeon
      @jhimeon Před 2 měsíci

      Last company I worked for w a s Lennox dealer and I would do multiple coils a week

    • @jhimeon
      @jhimeon Před 2 měsíci

      Mo s t 1 or 2 years old

  • @HonchHeado
    @HonchHeado Před 2 měsíci

    Hey Mike what happened to that guy you had workin for you Tove?

    • @PipeDoctor
      @PipeDoctor  Před 2 měsíci +1

      He moved on

    • @HonchHeado
      @HonchHeado Před 2 měsíci

      @@PipeDoctor Weird he was ok thanks mike

    • @HonchHeado
      @HonchHeado Před 2 měsíci

      @@PipeDoctor Did he move on in a good way? Reason I ask is cos of all the shit heads we get lol

  • @edbuscus360
    @edbuscus360 Před 2 měsíci

    Got a complaint at the end of an annual ac service. Guy said he only paid 45 dollars for the last one and my price was way too high. Mind boggling to see handymen wiping off the outside of a condenser and calling it an “ac clean and check” it’s just sad.

    • @numchux2
      @numchux2 Před 2 měsíci

      so dude makes 200 dollars a day at best waxing condensers...chump change

  • @Kevin-wj4ed
    @Kevin-wj4ed Před 2 měsíci

    Wouldn't it be great if manufacturers designed there equipment so it would easier to work on!!!!!!!!!!!!!!

  • @tuffram2165
    @tuffram2165 Před 2 měsíci +2

    Lennox is the absolute worst residential unit's period. I absolutely hate them I would actually prefer Goodman over Lennox.

    • @numchux2
      @numchux2 Před 2 měsíci +1

      I used to work for a Lennox premier dealer, and yes Lennox is just goodman with a business suit and a haircut at best

  • @kens.3729
    @kens.3729 Před 2 měsíci +2

    Shut-Off Breaker is Absolutely Ridiculous. How do Hacks stay in Business ? It’s quite Obvious the Hack that Installed this Danger Condition doesn’t Live here. 🤪👎

  • @HonchHeado
    @HonchHeado Před 2 měsíci

    You put 2 pounds? Dude leak.

  • @kemarp1
    @kemarp1 Před 2 měsíci

    First of all Why is everyone speeding.?!... slow down.!.. and youre deiving too close