INSTALLING a DAIKIN DUCTLESS MINI SPLIT | AIR CONDITIONER ❄️

Sdílet
Vložit
  • čas přidán 20. 06. 2022
  • HVAC | REFRIGERATION | AIR CONDITIONING VIDEO
    Today I installed another Air Conditioner. Unfortunately I had to rush at the end because it started to rain. I hope you enjoy the video!

Komentáře • 44

  • @adamisherwood6708
    @adamisherwood6708 Před měsícem +2

    The music and drilling sound track is ………it! But the thoughtful installation was Great !

  • @delspark
    @delspark Před rokem +3

    Very nice 👌 I normally core drill a 65mm hole through the wall

    • @maracservices
      @maracservices  Před rokem +1

      Thanks mate. I have a core hole bit but I don’t use it that often to be honest. I find stitch drilling is less messy as it doesn’t seem to throw the dust around the room as much. You might have a better technique though

  • @JuanTodoli
    @JuanTodoli Před 2 lety +1

    Good job Mitch 👌

  • @abuzarhalakoei8866
    @abuzarhalakoei8866 Před rokem +1

    great job👌

  • @VinceCuzmono
    @VinceCuzmono Před 2 lety +2

    Awesome content! Went back and watched your vrv stuff, I rarely get to see it here in the states and I'm in really hot Florida. 99% is single stage ducted cookie cutter abomination.

    • @maracservices
      @maracservices  Před 2 lety

      Haha thanks mate. I appreciate it! I love VRVs and am in the process of installing one at the moment which I’ll be filming 🤙🏼

  • @ianorr760
    @ianorr760 Před 2 lety +1

    Schmick job as usual mate 👌🏼

  • @seanz1983
    @seanz1983 Před rokem +3

    Hey Mitch excellent video. What kind of wall plugs do you use for fixing exterior brackets? You use some kind of plastic sleeves instead of regular dynabolts.

    • @maracservices
      @maracservices  Před rokem +2

      Thanks mate. I never used dynabolts. They’re actually designed for concrete slabs (I’m not sure why they come with most brackets). I use Hilti HRD anchors instead which are great. Cheers

  • @jonathonwilliams6722
    @jonathonwilliams6722 Před 2 lety +1

    The Daikin indoor unit pipe length has caught me out a few times. And why is the small pipe that's easier to bend longer haha if the lengths were reversed it would be so much easier. Great job as usual mate 👍

    • @maracservices
      @maracservices  Před 2 lety +1

      It’s so frustrating aye. I’ve had to do this that many times that I’ve lost count. Considering changing brands for double brick homes. I agree, why can’t the suction pipe be the longer one haha.

    • @jonathonwilliams6722
      @jonathonwilliams6722 Před 2 lety +1

      On back to backs I have been making the outside hole quite a bit lower than the inside hole and angled up heavily. Have found that easier to get the bend to keep it in the duct.
      Also talking of large outdoor units. Bloody floor consoles have huge o/d units 🤣 haha

    • @maracservices
      @maracservices  Před 2 lety +1

      @@jonathonwilliams6722 haha dude, the new 7kW Daikin ducted units (standard inverter) are so small they look like a 2.5kW. Couldn’t believe my eyes. 😂

    • @MarcelHVAC
      @MarcelHVAC Před rokem +1

      @@maracservices You should cut the flares of and braze the lineset directly on the inside unit, works so much better!

    • @maracservices
      @maracservices  Před rokem +1

      @@MarcelHVAC that’s what I did in this video. The flares would of been inside the wall so I just cut and brazed the pipe. 👍🏻

  • @volvot5turbo
    @volvot5turbo Před 7 měsíci

    I notice the outdoor unit is quite close to the outside wall. I have installed 2 x Electriq units on my wall, about 14" away but up on a flat roof like yours. Can I move them closer to the wall?

  • @MarcelHVAC
    @MarcelHVAC Před rokem +1

    I drill the holes 62mm with a diamon core drill with vacuum cleaner attached.
    That is how you guys should do that too.

    • @maracservices
      @maracservices  Před rokem +1

      I have a core hole bit too but I found stitch drilling it faster and less messy. However I like your idea about attaching a vacuum cleaner. Is it a special core hole bit or do you just hold the vacuum up against the hole you’re drilling? I’m curious.

    • @MarcelHVAC
      @MarcelHVAC Před rokem +1

      @@maracservices It is special drill and i sucks vacum thru the core of the drill In my country there is a lot of concrete so we have too use a good drill

    • @maracservices
      @maracservices  Před rokem +1

      @@MarcelHVAC that’s awesome. I want one.

  • @bzerk86
    @bzerk86 Před 2 lety +2

    Is the 7kw ducted unit a standard or premium? Standard wouldn't overspeed, the split would, maybe they allow for the extra capacity by having a larger unit? Just a thought.

    • @maracservices
      @maracservices  Před 2 lety +3

      The ducted was actually a Standard unit. I think it’s because the indoor coil is a lot bigger so therefore the outdoor coils don’t have to be as big.
      I know that other brands are different. For example the Panasonic 7kW outdoors are way bigger then Daikin but the indoors are smaller. Who knows, I just thought it was weird 😂

  • @cody8576
    @cody8576 Před rokem +2

    Hey Mitch this might sound like a silly question because I’m still learning how to install AC, but what is the main reason for running the drain pipe to the gutter down pipe? Could you just have it come straight out of the unit and straight down say 100mm?

    • @maracservices
      @maracservices  Před rokem +2

      That’s not a stupid question at all mate. I actually prefer running the drain pipe straight down and letting it drip into a garden or something however the reason I ran it to the drain is because I didn’t want it to just drip on top of the shed and create a puddle. However I personally don’t like connecting it straight to a down pipe incase the down pipe gets blocked. So to answer your question, the only reason I run a drain pipe is so it doesn’t create a puddle of water. Thanks

    • @cody8576
      @cody8576 Před rokem +1

      @@maracservices cheers for the fast reply man

  • @daveyboy8907
    @daveyboy8907 Před rokem +1

    Did you custom bend the outside pipe covers on a brake or is that store bought??

    • @maracservices
      @maracservices  Před rokem

      I just cut it on site using tin snips and a combination square mate. So to answer your question, I bend it on site. 👍🏻

  • @thestableman7406
    @thestableman7406 Před 2 lety +1

    Awesome work! You’ve made installing aircon in to an art !
    Speaking of installing.. Any chance you can install a Nintendo for me?

  • @BERESHIDA2008
    @BERESHIDA2008 Před rokem +1

    GREAT CONTENT , BUT WHY DRILL TO THE WRITE SIDE OF THE INTERIOR UNIT , WOULD BEEN BETTER TO DRILL TO THE LEFT, AND KEEP THE FLARE INSIDE AND NOT SOLDERING NEED IT

    • @maracservices
      @maracservices  Před rokem

      Thanks mate. In Australia, you’re not allow to have R32 flares inside the living space because the refrigerant is flammable.

  • @cody8576
    @cody8576 Před rokem +1

    Also how long would it normal take to do a mini split install like this one if your weren’t filming ect?

    • @maracservices
      @maracservices  Před rokem

      If it is with a helper. 4 hours. When I’m alone more like 7-8 hours. Back to back I could do much quicker though.

    • @cody8576
      @cody8576 Před rokem +1

      @@maracservices taking me about the same time maybe a bit longer. I Need to get a lifter like you man I like how you mount the condensers up high it looks much more professional and neat.

    • @maracservices
      @maracservices  Před rokem

      @@cody8576 thanks man appreciate it

    • @maracservices
      @maracservices  Před rokem

      @@cody8576 also who cares how long it takes. It’s all about how neat it looks. Just because people can install quicker doesn’t mean it’s any good 😂

  • @prowesstv
    @prowesstv Před 2 lety +1

    *Ductless minisplit