Functional Parts Layout an Daikin VRV-4 air-conditioning (A-series)

Sdílet
Vložit
  • čas přidán 25. 08. 2024

Komentáře • 133

  • @brandonle4930
    @brandonle4930 Před 2 lety +3

    Love this version of how you do a break down on the unit. Always looking forward to your video. Thank you for the education.

  • @ayelwin5894
    @ayelwin5894 Před 7 měsíci +2

    Good inspection

    • @BonMj
      @BonMj  Před 6 měsíci

      Thanks 👍

  • @goparismail9727
    @goparismail9727 Před 2 lety +2

    sukses selalu bos ku Bon MJ ilmuya bermanfaat buat teknisi infoneaia🙏🏻🙏🏻🙏🏻🙏🏻 sehat selau

    • @BonMj
      @BonMj  Před 2 lety

      Terima Kasih master.

  • @moorthilatha5739
    @moorthilatha5739 Před 2 lety +2

    🥰👌👌good explain 👌👌

  • @chandrarul365
    @chandrarul365 Před rokem +1

    Hi Boss, I am watching all the video’s so helpful thank you so much I can improve my skills once again thank you so much. Chandr

  • @salimagwan9672
    @salimagwan9672 Před 2 lety +2

    You keep making videos like this and keep guiding us thank you mj sir

  • @manikandanmani646
    @manikandanmani646 Před 2 lety +2

    Hi Bro Good job And very useful information 👏🥳👨‍🔧

  • @BonMj
    @BonMj  Před 2 lety +1

    CORRECTION
    7:28 minutes Right hand side is Compressor 1 and left hand side is Compressor 2.
    Sorry for the inconvenience.
    Thanks🙏🙏

  • @ayyanraj6593
    @ayyanraj6593 Před rokem +1

    Thank you sir✌️😊 your videos all are very use ful tips and gifts to technicians and project leaders because they are also learn and gain knowledge ☺️☺️

  • @andyreyes6464
    @andyreyes6464 Před 8 měsíci +1

    thank you for the explanation, very wise

    • @BonMj
      @BonMj  Před 8 měsíci

      You're very welcome

  • @Kahobbyfarming
    @Kahobbyfarming Před 2 lety +1

    Very professional product demostration regarding parts and operation of the equipment,Thanks for the video.

  • @queentekindoutama484
    @queentekindoutama484 Před 5 měsíci +1

    Mr bon your perfect mantapp

    • @BonMj
      @BonMj  Před 5 měsíci

      Terima kasih

  • @CCL13984
    @CCL13984 Před rokem +1

    Thx,sir !I learned more knowledge by this viedo

    • @BonMj
      @BonMj  Před rokem

      👍

    • @CCL13984
      @CCL13984 Před rokem

      @@BonMj sir, I have a problem, why I disable whole slave 1, the master unit was error and show UA-54 on display, at same time, the master unit can be normally operation, Which is VRV X7!🙏🙏

  • @wd8557
    @wd8557 Před 2 lety +1

    More people should do this, god bless you.

  • @toufikmatib9855
    @toufikmatib9855 Před 2 lety +1

    Thank you for sharing Bon

  • @moisesgarcia7708
    @moisesgarcia7708 Před 5 měsíci +1

    I like you video sir 👍👍👍

    • @BonMj
      @BonMj  Před 4 měsíci

      Keep watching.Thanks

  • @ahamedwashim5537
    @ahamedwashim5537 Před rokem +1

    Thanks 👍

  • @allanbayten3959
    @allanbayten3959 Před rokem +1

    thank you sir bon mj ❤

  • @sureshshirsath9325
    @sureshshirsath9325 Před rokem +1

    thank you so much sir,...

  • @matazmataz4287
    @matazmataz4287 Před 2 lety +1

    Ich bin dir sehr dankbar 😊 und du bist der bester

  • @karimchiu7527
    @karimchiu7527 Před rokem +1

    thank sir Bon

    • @BonMj
      @BonMj  Před rokem

      Welcome 🙏🙏

  • @footballguy4209
    @footballguy4209 Před rokem +1

    ❤Thank you Mr.Bon🙏

  • @RLTVCHANNEL
    @RLTVCHANNEL Před rokem +1

    Thanks for your video I learned on refrigeration..

  • @mohamadmosavi1625
    @mohamadmosavi1625 Před rokem +1

    Good man
    Thank you

  • @GodofredoTalin
    @GodofredoTalin Před 2 lety +1

    Thank you mr. Bon

  • @sezginkaradeli3072
    @sezginkaradeli3072 Před 5 měsíci +1

    Bon mj thank you süper

    • @BonMj
      @BonMj  Před 5 měsíci

      Always welcome

  • @matazglb5346
    @matazglb5346 Před 2 lety +1

    Hi, thank you 😊

  • @sivakumar-te5kt
    @sivakumar-te5kt Před 2 lety +1

    Good Explanation thank you so much sir

  • @peramaraj2763
    @peramaraj2763 Před 2 lety +1

    Good explain sir i would like to know more technical videos sir

  • @mualacorachgiabestbuy1072

    Good job

  • @wandritira1973
    @wandritira1973 Před 4 měsíci +1

    mantap

    • @BonMj
      @BonMj  Před 4 měsíci

      Terima Kasih

  • @tapumondol41
    @tapumondol41 Před 10 měsíci

    I like your video

  • @imranalam8575
    @imranalam8575 Před rokem

    Very appreciated

    • @BonMj
      @BonMj  Před rokem +1

      Thanks

    • @imranalam8575
      @imranalam8575 Před rokem +1

      @@BonMj sir I want to learn more about inverter technology. I need your opinion if there is any online classes in your platform.

  • @agusanwar107
    @agusanwar107 Před 2 lety +1

    thanks Master HVAC

  • @popescuvalentin3711
    @popescuvalentin3711 Před rokem +1

    😊😊😊

  • @karaors8970
    @karaors8970 Před 2 lety +1

    Hi bro. Super video bon 🤳🛠️👍✋🇹🇷

    • @BonMj
      @BonMj  Před 2 lety +1

      Thanks master🙏

  • @khaidang8614
    @khaidang8614 Před rokem +1

    ❤🎉❤🎉

  • @hitmankingdom825
    @hitmankingdom825 Před 2 lety +1

    Thanks you sir

  • @janshaw5472
    @janshaw5472 Před 2 lety +1

    看的头疼,这么多thermistor

    • @BonMj
      @BonMj  Před 2 lety

      是一套的。

  • @narayanaya5519
    @narayanaya5519 Před rokem +1

    Please post video about dc fan motor how to check good or defect

  • @noside8469
    @noside8469 Před 2 lety +1

    Hello Sir, Uncle Bon,
    Can you also make a video explaining the difference between VRV, VRF and ordinary split 5tr type aircon.
    Watching from the Philippines 🇵🇭🇵🇭🇵🇭💚❤💚❤

  • @sathishkumarsamson3558
    @sathishkumarsamson3558 Před 2 lety +2

    Hi am working in dubai in VRV 4 E9-3. alarm recived . We replaced EEV and motor as well also we replaced NEW Pcb .but still alaram same .E09-3
    Kindly help me to get solve this problem .

  • @narayanaya5519
    @narayanaya5519 Před rokem +1

    Let me know that copper pipe connected near pcb what purpose

  • @ayyanraj6593
    @ayyanraj6593 Před rokem +1

    Could you please all thermistor actual range sir

  • @tabresztabu562
    @tabresztabu562 Před 2 lety +1

    Tq boss ✌️

  • @peramaraj2763
    @peramaraj2763 Před rokem +1

    How to find ambient temprature sir ?

  • @user-rc1lu6ig1q
    @user-rc1lu6ig1q Před 2 lety +1

    👍👍👍

  • @lokeshlokeshkumar2107
    @lokeshlokeshkumar2107 Před 2 lety +2

    Daikin vrv CFM how to check plz explain sir..

  • @user-ol4sw6rm3h
    @user-ol4sw6rm3h Před 5 dny +1

    Hey bon having a Lc-30 error code on daikin vrv , reset power supply but error code still came back.

    • @BonMj
      @BonMj  Před 2 dny

      LC-30 check inverter pcb 2

  • @hashim3062
    @hashim3062 Před rokem +1

    How to reset the LC-14 error alarm? I've tried resetting, always the LC-14 error alarm

    • @BonMj
      @BonMj  Před rokem

      May Pcb faulty

  • @leelichard5092
    @leelichard5092 Před 2 lety +1

    Bon,感谢您的技术分享;我刚去荷兰的一家空调公司,我们有大金的系列,这次学到了不少,您是这方面专家,有机会希望可以请教到您。

    • @BonMj
      @BonMj  Před 2 lety

      谢谢你看我的视频。

  • @amfox8298
    @amfox8298 Před 2 lety +1

    Sir daikin VRV 4 PCB and senser available please replay me

  • @LC-qi5ff
    @LC-qi5ff Před rokem +1

    Is gas pipe the suction pipe?

    • @BonMj
      @BonMj  Před rokem

      Red for discharge pipe
      Blue for return pipe

  • @andhykafredysasmito4131
    @andhykafredysasmito4131 Před rokem +1

    berarti gas sama liquid jadi satu y pak

  • @ronellolpos8668
    @ronellolpos8668 Před 2 lety +1

    Hello my friend im here in philippines, i got a costumer service call, daiken model RKC35PVM error f3, i just cleaning the condenser but unit run only for just 2days, and now the customer call me again said that the a,c is brinking again, any idea for this my friend

    • @BonMj
      @BonMj  Před 2 lety

      Check gas pressure
      Check discharge pipe thermistor

    • @ronellolpos8668
      @ronellolpos8668 Před 2 lety

      @@BonMj gas pressure standing is 250 psig, running pressure of 130psig and amps of 6.58 on clamp meter out 8.28 amps, discharge pipe thermistor is 11 ohms in 37 ambient temp

    • @ronellolpos8668
      @ronellolpos8668 Před 2 lety

      I am the second technician who check the unit, and according to the customer the first tech finding is eev problem,

    • @brandonle4930
      @brandonle4930 Před 2 lety +1

      Did you hook up the service checker to see what temperature of the compressor surface area compare to the actually temp? If temperature is incorrect from the service checker compare to your actual check. Replace main PCB

    • @ronellolpos8668
      @ronellolpos8668 Před 2 lety

      @@brandonle4930 sir, i have only guage manifold and clamp meter

  • @samirfroid3928
    @samirfroid3928 Před 2 lety +2

    hi sir i have a problem in this vrv (pj 04) please would you help me

    • @BonMj
      @BonMj  Před 2 lety +1

      Do you replace pcb?

    • @samirfroid3928
      @samirfroid3928 Před 2 lety

      @@BonMj yes

    • @samirfroid3928
      @samirfroid3928 Před 2 lety +1

      the old pcb is EB12042(F)
      the new one is EB12042(L)

    • @BonMj
      @BonMj  Před 2 lety +1

      @@samirfroid3928 may setting not match

    • @samirfroid3928
      @samirfroid3928 Před 2 lety +1

      @@BonMj Can you give me the special edits because they didn't come with the new PCB EB12042(L) please .

  • @Lee-mu2jc
    @Lee-mu2jc Před 2 lety +1

    Boss r3t to r6t how many ohm thankyou

    • @BonMj
      @BonMj  Před 2 lety

      Aound 14K ohm

  • @kayodejulius2388
    @kayodejulius2388 Před 2 lety +1

    How can I bring back the master after bypass

  • @khaidang8614
    @khaidang8614 Před rokem +1

    Việt Nam HCM

  • @ANKITKUMAR-qu7vm
    @ANKITKUMAR-qu7vm Před rokem +1

    E4 error vrv x

    • @BonMj
      @BonMj  Před rokem

      Check pressure

  • @peramaraj2763
    @peramaraj2763 Před 2 lety +1

    Today just happen sir whenever you free you explain to me VRV-3 one CU 7 nos of FCUs Blinking E3 error code is have after reset all FCUs just CU run up compressor 2 or 3 minute cut off similarly 3 times after MCB trip what is the issue sir please explain.

    • @BonMj
      @BonMj  Před 2 lety

      Inverter compressor ok?
      Standard compressor ampere?

    • @peramaraj2763
      @peramaraj2763 Před 2 lety +1

      @@BonMj inverter compressor already faulty standard compressor from 6 to 10 reached within 1 after cut off the compress sir

    • @BonMj
      @BonMj  Před 2 lety

      @@peramaraj2763 if standard compressor running amps over 10amps consider over current.need to replace compressor or you try wash CU first

    • @peramaraj2763
      @peramaraj2763 Před 2 lety +1

      @@BonMj standard compressor running amps-19.89 ,low side - 198 psi,high side -360 psi .sir

    • @BonMj
      @BonMj  Před 2 lety

      @@peramaraj2763 19.8A compressor over current. (Make sure the cu is one inverter and one/two standard compressor)