Minimum size of Column 9"x12" reinforcement making / CIVILTECHCONSTRUCTIONS
Vložit
- čas přidán 12. 09. 2024
- MINIMUM Size of column reinforcement making process
9inch X 12 inch
#Civiltechconstructions
FOLLOW ON INSTAGRAM :
/ civil_tech_cons. .
Building Construction Process step by step process
• Building / House Const...
building construction individual videos plylist
SLAB construction process Part -1
• SLAB construction proc...
1.5 feet deep BEAM 25mm Rods #civiltechconstructions / watch
• 1.5 feet deep BEAM 25m...
BEAM INSTALing TECHNICS #civiltechconstructions / WATCH
• BEAM INSTALLATION TECH...
BEAM MAKING PROCESS ON SITE #CIVILTECHCONSTRUCTIONS / WATCH
www.youtube.co...
Cantiliver Beam on site / watch #civiltechconstructions
• Cantilever Beam on sit...
Making of stirrups for beams
• Making of stirrups for...
Slab Form work Process Building constructio#civiltechconstructions
• Technics for Slab Form...
ON site safety and construction Tools for workers
• CIVIL Worker On SITE S...
Staircases casting BUILDING construchconstructionsction part-14/watch #civilte
• Staircases constructio...
Staircases Reinforcement BUILDING construction part-14
• Staircases Reinforceme...
Septic tank slab construction
• Septic tank slab const...
Column casting Building construction part-13
• Column casting Buildin...
Column Extension reinforcement Building construction part-12
• Column Extension reinf...
Starter After plinth beam Building construction part-11
• Column Starter After P...
Plinth Reinforcement Process Building construction part-9
• Plinth Reinforcement P...
columns building construction part-8
• columns building const...
Column starter Building construction part-7/ watch #civiltechconstructions
• Column starter Buildin...
Building construction part-5 columns reinforcement and installing
• Columns Reinforcement ...
Building construction-1 foundation Plan Implimentation technics on site / #civiltechconstruction
www.youtube.co....
Building construction part 2 marking of columns / watch #civiltechconstructions
www.youtube.co....
Sunkenslab reinforcement detail #civiltechconstructions / like,share,comment,subscribe
• Sunkenslab reinforceme...
Retaining wall construction
• Retaining wall constru...
Cantilever Retaining wall construction
• Cantilever Retaining w...
House design 200sq.yards, 25lacks with interior watch it
• House design 200sq.yar...
Stone wall construction to prevent entry of rats
• Stone wall constructio...
Curing techniques,compressive strength of concrete
• Curing techniques,comp...
Earth back filling & flooring PCC
• Earth back filling & f...
Channel Expansion,Contraction
• Channel Expansion,Cont...
Canal Regulator
• Canal Regulator
Column construction process
• Column footing to grou...
Stirrups and lateral ties reinforcement details
• FULL Details about St...
How to find Lateral ties length in drawing
• How to find Lateral ti... ILTECHCONSTRUCTIONS
Stirrup hook is not proper, it sholud be bend at 135°...
Nice
Sir how to face auto cad and GIS mapping interview please reply sir..,
Concrete covering kitna hoga
Footing 50mm
Column ,Beams 25mm
@@civiltechconstructions thank you sir
I think you should place #2 no.s of 12mm dia bar in 12" side rather than on 9" side. Let me know if I am wrong.
12mm size of 4 bars at 4 corners and where there is less width here 9" We put extra bar.
sir i have taken all 16 mm rods of 6nos in my column of 12,9 is it safe..?
Here design considerations important this is small house so minimum 12mm. As per Room sizes and number of floors we will design and implement it.