Minimum size of Column 9"x12" reinforcement making / CIVILTECHCONSTRUCTIONS

Sdílet
Vložit
  • čas přidán 12. 09. 2024
  • MINIMUM Size of column reinforcement making process
    9inch X 12 inch
    #Civiltechconstructions
    FOLLOW ON INSTAGRAM :
    / civil_tech_cons. .
    Building Construction Process step by step process
    • Building / House Const...
    building construction individual videos plylist
    SLAB construction process Part -1
    • SLAB construction proc...
    1.5 feet deep BEAM 25mm Rods #civiltechconstructions / watch
    • 1.5 feet deep BEAM 25m...
    BEAM INSTALing TECHNICS #civiltechconstructions / WATCH
    • BEAM INSTALLATION TECH...
    BEAM MAKING PROCESS ON SITE #CIVILTECHCONSTRUCTIONS / WATCH
    www.youtube.co...
    Cantiliver Beam on site / watch #civiltechconstructions
    • Cantilever Beam on sit...
    Making of stirrups for beams
    • Making of stirrups for...
    Slab Form work Process Building constructio#civiltechconstructions
    • Technics for Slab Form...
    ON site safety and construction Tools for workers
    • CIVIL Worker On SITE S...
    Staircases casting BUILDING construchconstructionsction part-14/watch #civilte
    • Staircases constructio...
    Staircases Reinforcement BUILDING construction part-14
    • Staircases Reinforceme...
    Septic tank slab construction
    • Septic tank slab const...
    Column casting Building construction part-13
    • Column casting Buildin...
    Column Extension reinforcement Building construction part-12
    • Column Extension reinf...
    Starter After plinth beam Building construction part-11
    • Column Starter After P...
    Plinth Reinforcement Process Building construction part-9
    • Plinth Reinforcement P...
    columns building construction part-8
    • columns building const...
    Column starter Building construction part-7/ watch #civiltechconstructions
    • Column starter Buildin...
    Building construction part-5 columns reinforcement and installing
    • Columns Reinforcement ...
    Building construction-1 foundation Plan Implimentation technics on site / #civiltechconstruction
    www.youtube.co....
    Building construction part 2 marking of columns / watch #civiltechconstructions
    www.youtube.co....
    Sunkenslab reinforcement detail #civiltechconstructions / like,share,comment,subscribe
    • Sunkenslab reinforceme...
    Retaining wall construction
    • Retaining wall constru...
    Cantilever Retaining wall construction
    • Cantilever Retaining w...
    House design 200sq.yards, 25lacks with interior watch it
    • House design 200sq.yar...
    Stone wall construction to prevent entry of rats
    • Stone wall constructio...
    Curing techniques,compressive strength of concrete
    • Curing techniques,comp...
    Earth back filling & flooring PCC
    • Earth back filling & f...
    Channel Expansion,Contraction
    • Channel Expansion,Cont...
    Canal Regulator
    • Canal Regulator
    Column construction process
    • Column footing to grou...
    Stirrups and lateral ties reinforcement details
    • FULL Details about St...
    How to find Lateral ties length in drawing
    • How to find Lateral ti... ILTECHCONSTRUCTIONS

Komentáře • 10

  • @sacivilsites268
    @sacivilsites268 Před 3 lety +3

    Stirrup hook is not proper, it sholud be bend at 135°...

  • @mazedaarkitchen1843
    @mazedaarkitchen1843 Před 3 lety

    Nice

  • @aaletisrikanth3116
    @aaletisrikanth3116 Před 3 lety

    Sir how to face auto cad and GIS mapping interview please reply sir..,

  • @parthadutta6913
    @parthadutta6913 Před 3 lety

    Concrete covering kitna hoga

  • @paulbhatra2291
    @paulbhatra2291 Před 3 lety

    I think you should place #2 no.s of 12mm dia bar in 12" side rather than on 9" side. Let me know if I am wrong.

    • @civiltechconstructions
      @civiltechconstructions  Před 3 lety

      12mm size of 4 bars at 4 corners and where there is less width here 9" We put extra bar.

  • @arbazabaaz538
    @arbazabaaz538 Před 3 lety

    sir i have taken all 16 mm rods of 6nos in my column of 12,9 is it safe..?

    • @civiltechconstructions
      @civiltechconstructions  Před 3 lety

      Here design considerations important this is small house so minimum 12mm. As per Room sizes and number of floors we will design and implement it.