Main Filter Replacement on Print Head Doctor

Sdílet
Vložit
  • čas přidán 3. 10. 2013
  • This short video shows how to replace the main filter module (a.k.a. 2nd stage filter) on Print Head Doctor models 5,6,7 and 8. It takes no longer than 1 minute and requires no tools.
    Step 1: Purge the fluid out of the machine.
    Step 2: Remove 4 thumb screws from the filter plate.
    Step 3: Pull out the filter. Do not apply stress to the tubing.
    Step 4: Unscrew the color-coded Luer nuts and detach the fittings.
    Step 5: Get a new filter and attach Luer fittings.
    *******************************************************************************
    ATTENTION: attaching fittings should be according to this sequence:
    1) Slightly tighten the nut.
    2) Push the fitting in by pressing on it, not on the nut.
    3) Tighten the nut with a moderate force.
    Failure to follow these instructions will result in fluid leaks!!!
    *************************************************************************
    Step 6. Re-install the filter plate and secure it with thumb screws.