24VOLTS EARTH FAULT BURNT 2 POWER SUPPLIES

Sdílet
Vložit
  • čas přidán 6. 06. 2022

Komentáře • 84

  • @lechzekjacobs2752
    @lechzekjacobs2752 Před 2 lety +30

    Laughed so hard when he said 'fuck up the new psu' not used to him swearing😆

    • @jlarellano7350
      @jlarellano7350 Před rokem +3

      I can definitely say why cuz what he did was was definitely time consuming. 😂

    • @dirkcanyow
      @dirkcanyow Před rokem

      10:23 bahhahah cracked me up.

  • @Bill_N_ATX
    @Bill_N_ATX Před 2 lety +13

    Great troubleshooting. I have trained many computer technicians and engineers and troubleshooting is not only a skill but an art. You clearly have the knack!

    • @leckyjake
      @leckyjake  Před 2 lety +3

      thank you for this wonderful comment

  • @r-ainjel4735
    @r-ainjel4735 Před 2 lety +3

    Great video of troubleshooting. Not only replacing a power supply but tracing the root cause of the problem (earth fault).
    Very essential in ballasting/deballasting and bunkering operation. Good Job lecky. Salute

  • @nopatience1417
    @nopatience1417 Před rokem +2

    You are very good at your job,tracking electrical faults is not easy.

  • @briwire138
    @briwire138 Před rokem +1

    Great job. I'm retired and I really miss searching out faults like this.

  • @fridaynighthikes
    @fridaynighthikes Před 2 lety

    Awesome troubleshooting. 🥇

  • @reefercontainerph4182
    @reefercontainerph4182 Před 2 lety

    Nice. Good Job Sir! 👍

  • @mohamedroomy1985
    @mohamedroomy1985 Před 2 lety

    Extremely informative and God bless you, Bro

  • @engkamel6240
    @engkamel6240 Před 2 lety +1

    Keep up the good work your videos inspired me to become an ETO . you're awesome 😎👍

  • @ehbbhe5011
    @ehbbhe5011 Před 2 lety +1

    excellent troubleshooting sir patience is the key on isolating trouble on electrical control system👍Godbless and keepsafe sir

  • @s895s607
    @s895s607 Před 2 lety

    Thank you sir,your vedio is very good and useful.

  • @junmaromega2747
    @junmaromega2747 Před 2 lety

    Galing mo talaga sir..thank you for sharing.

  • @johncantrell614
    @johncantrell614 Před 2 lety

    Thanks for sharing!

  • @naushadansari7343
    @naushadansari7343 Před rokem +1

    i am a big fan of your work sir i have learned a lot from your videos.
    Lots of love for you from India

  • @Arkiko
    @Arkiko Před 2 lety

    Very informative, thanks.

  • @renzruiztv139
    @renzruiztv139 Před 2 lety

    Good Job Partner.. Safety First

  • @cameronboyett6386
    @cameronboyett6386 Před 2 lety

    Good troubleshooting

  • @Dyllanes_Ingeniero
    @Dyllanes_Ingeniero Před 2 lety +2

    Saludos desde México 🇲🇽. Greetings from Mexico. Excelente 👌👍

  • @dnlcmndjr
    @dnlcmndjr Před 2 lety

    great vid . informative !!

  • @thefishingsmith4430
    @thefishingsmith4430 Před rokem

    galing kabayan..

  • @jenverjulian8201
    @jenverjulian8201 Před 2 lety

    thats the trouble shoot very tensions need patience..but you did great job i learn that work...keep it up

  • @BobHannent
    @BobHannent Před 2 lety +2

    Previously I have located shorts using a TDR because it can give you a "distance to fault" and if you move to a different probe point you'll either be closer or further, although with lots of open circuits in this way, it might be harder than when I do it with data lines. Another electronics technique from circuit diagnosis is to use a micro-Ohms meter so you can see the very small differences in resistance as you get closer to the fault. Both these are more expensive/complex than simply disconnecting each node and checking it, but time is money in some cases.

  • @rodneycololot5467
    @rodneycololot5467 Před 2 lety +2

    Thank you sir for your advice and knowledge sharing

  • @officerkrupke4966
    @officerkrupke4966 Před rokem

    . Breakers and fuses are mainly there to protect the wiring from burning up, but I would install a fast blow, it sometimes protects dc power supplys. The 3amp uc1 cello lite fuse you have shown is a time delay fuse. Slow blow fuses will fry power supplys for sure.

  • @0dbm
    @0dbm Před 2 lety

    Nothing like a good ground fault to chase down , job well done

  • @abhijitnayak5445
    @abhijitnayak5445 Před 2 lety +2

    Thank you sir..as a trainee ETO I must salute you..

  • @shadowbanned69
    @shadowbanned69 Před 2 lety +4

    Lmao..so will not um...fuck up the new power supply...nice Jake
    If ya can't find the words...cuss at it till it works...
    Your on your way to becoming a honorary American sailor buddy 👍

  • @tomtom7520
    @tomtom7520 Před 2 lety

    Curious on when to use a ground on a vessel? My main job is a diesel mechanic. When I watch electricians, I've heard them say things like never to use a ground, or the hull is a ground. Should a ground on a circuit be set up like a residential electrical?

  • @sebbosich2142
    @sebbosich2142 Před 2 lety

    you are the king boss

  • @adityaputra6747
    @adityaputra6747 Před rokem

    I hope i could work with you someday.. but the video giving alot of inspirations and lessons.. terimakasih po

  • @scotts4125
    @scotts4125 Před 2 lety

    I hope you make another video with the cause and repair.

  • @trcostan
    @trcostan Před 2 lety

    70k ohm seems like a high resistance to cause damage to a 2 amp power supply! But I suppose it could be a non linear thing like water in a connection

  • @mahzirslumber9720
    @mahzirslumber9720 Před 2 lety +1

    Hello I have questions why same voltage different ampere?.. and before that I had got the answer ampere from friend value ampere depends on load work... So That right or not?

  • @YouTubeviolatesmy1stamendment

    But why didn't the fuse blow if the power supply rating was more than 3 amps why didn't the 3 amp fuse blow first

  • @weetv69
    @weetv69 Před 2 lety

    Galing sir 😀👍 moore. Hehe

  • @gosho0
    @gosho0 Před 2 lety +1

    Awesome video, I only did not understand - how did you found which valve is the culprit?

    • @kurtronaldesteban8190
      @kurtronaldesteban8190 Před 2 lety +1

      In the last part, when he is measuring one by one the white wires (going to the limit switches of the valves). He measured line to earth resistance and from there he was able to see which particular valve was causing the earth fault.

  • @cck1496
    @cck1496 Před 2 lety

    Good video. What is FG on Power Supply & U & V lines feeding the Power Supply?
    I am mechanical. Thanks.

  • @robertpeters9438
    @robertpeters9438 Před rokem

    Could those power supplies be still good and were only in current limit?

  • @andyfannan8298
    @andyfannan8298 Před 2 lety +1

    Good video. How did you earth chase at the start of the video? Did you put the neg and pos probes across the fuse and it should read OL but read 70k ohms indicating earth?

    • @cck1496
      @cck1496 Před 2 lety +1

      Is it important to remove the fuse for checking the ground fault?
      Thanks.

    • @JohnvetMarcellana
      @JohnvetMarcellana Před 2 lety

      The line is line-to-neutral and if you test for resistance between the two you should not get resistance and it means not shorted. The negative or neutral is bound to grounding, so he focus on hot line side which he found out shorted or connected to ground or having earth fault. He test all others(connected to line side) line to ground to determine which is connected to ground/shorted. That's all I understand.

    • @JohnvetMarcellana
      @JohnvetMarcellana Před 2 lety

      @@cck1496 I think it's for safety and at the same time reducing the work itself. Imagine the line below the fuse is good(no line to ground fault), you will just focus on upper side of the fuse, and it's just a wire so it's easier troubleshooting

    • @andyfannan8298
      @andyfannan8298 Před 2 lety

      He checked the load side of the fuse to ground?

    • @JohnvetMarcellana
      @JohnvetMarcellana Před 2 lety

      @@andyfannan8298 Yes

  • @mohamedessa8146
    @mohamedessa8146 Před 2 lety +2

    good job.but even reading 70 k ohm is not too much earthing .by equation I=24 v/70000 ohm=3 mA .so I think that's not the main reason for burned power supply

    • @Nerd3927
      @Nerd3927 Před 2 lety +6

      It is an indication that something is not right. And the fluke only measures at a few volts. At 24V the resistance can be a lot lower.

  • @2912dungha
    @2912dungha Před 9 měsíci

    Please show us how to take 24 vol earth alarm for battery charger room Japanese type vesel. From one Fan of U.

  • @00hate00
    @00hate00 Před 2 lety

    I'm a refrigeration service technician, specializing in light commercial however I have experience in supermarket refrigeration as well. I have an AA in refrigeration mechanics but I am wondering how much more education and training I would need to work as a marine electrician like yourself?

    • @stillthakoolest
      @stillthakoolest Před rokem

      First you need to train as a merchant mariner. School is the easiest way to start.

    • @zxcvbnmzxcv4244
      @zxcvbnmzxcv4244 Před rokem

      You can work on passenger ships as an HVAC technician.
      You need to speak to a crewing agency near you, write down their suggestions.
      Inform yourself what it means to work on sea. Maybe the lifestyle is not suitable for you or maybe your health does not allow it.
      Look at an job opening for a hvac technician on passenger ships to have a feeling for the requirements.
      You can also work as an reefer technician on container ship, also check job description.

  • @mannyantipolo1066
    @mannyantipolo1066 Před 2 lety

    Wer it does belong sir d wire did u isolate..?

  • @fredsalter1915
    @fredsalter1915 Před rokem

    What does "lecky" mean? Is it Tagalog? Thanks, good sir! I love watching your vids!!!

  • @boshy0989
    @boshy0989 Před rokem

    Need help here. How can the Power Supply be burned or shorted when the fuse was intact to begin with? Shouldn’t the fuse be burned down first and save the power supply?

    • @arnelbolo5720
      @arnelbolo5720 Před rokem

      I think the fuse is to high value rating. Use the correct fuse size.

  • @sivaprasad-nk6ij
    @sivaprasad-nk6ij Před 2 lety

    Hlo sir. Can you please make a video about how to charge freon properly to reefer.

  • @davidmears9410
    @davidmears9410 Před 2 lety

    Total star

  • @syedraheelhussain3904

    U should teach diagram

  • @raphaelflores9496
    @raphaelflores9496 Před 2 lety +1

    Helo Sir ask ko lang po about sa battery na lead acid. Pwede ba haluan ng battery solution ang battery kahit kaunti lang like 5cc?

    • @leckyjake
      @leckyjake  Před 2 lety

      i suggest follow kung ano ang specs at required sa batteries ninyo.

    • @raphaelflores9496
      @raphaelflores9496 Před 2 lety

      @@leckyjake ok po Sir.. Kasi ang S.G. below 1.5 kasi or 1.5 Sir

  • @f2p481
    @f2p481 Před 2 lety

    Hindi ba sya kasama sa grounding alarm ng 24v sir jake?

    • @leckyjake
      @leckyjake  Před 2 lety

      hindi siya kasi ang main supply is 100V so kasama sa 110V na system

    • @f2p481
      @f2p481 Před 2 lety

      @@leckyjake Makes sense at hindi rin sya madedetect ng 110v sa low insulation. Dapat may sarili sya kasama sa panel nya. This is really good as an additional learning. Thanks sir jake.

  • @jhundystv2554
    @jhundystv2554 Před 2 lety

    Good day sir. I would like to ask about my reefer trouble for STARCOOL. SET POINT = - 3.0, SUPPLY = 11.6, RETURN= 12.3. After 4 to 5 hours na mamatay po yong compressor nya. Pro wala nmn pong alarm sa panel. Ano po kaya problema nya. Please confirm po salamat

    • @leckyjake
      @leckyjake  Před 2 lety

      better check the pressure. to troubleshoot, kailangan alam mo yung working pressures.

    • @jhundystv2554
      @jhundystv2554 Před 2 lety

      @@leckyjake pressure check muna gagawin ko dito sir?

    • @jhundystv2554
      @jhundystv2554 Před 2 lety

      Goodmorning po sir.. Sir panaano po ba proper na pag refill nang freon sa reefer container. Nka off po yung compressor motor or naka andar po? Salamat

  • @rodelocon6791
    @rodelocon6791 Před 2 lety +1

    Thank you sir new learning!
    May question po ako sir anu po ginawa nyu sa isolated cable the one that's causing the fault. Bakit na disregard napo. Wla po ba cyang bilang sa ckt diagram sir. Salmt po

    • @leckyjake
      @leckyjake  Před 2 lety +1

      hi, bubuksan pa yung valve na yun kung ano problema but for the mean time hindi muna magbibigay ng indications sa panel kung open siya or close pero magagamit parin siya yun nga lang need i check manually kung talagang naka bukas or sara sa actual.

    • @rodelocon6791
      @rodelocon6791 Před 2 lety

      @@leckyjake Thank you sir.

  • @adnanabro3733
    @adnanabro3733 Před 2 lety

    Sir generator wiring diagram make video on it kindly.

    • @leckyjake
      @leckyjake  Před 2 lety +1

      have some for the governor. pa check nalang sa channel