Hack: Increasing the time and adding reset switch to 555 Relay Timer

Sdílet
Vložit
  • čas přidán 25. 07. 2024
  • This tutorial show you how to change the timer time to 40 seconds or more and add reset switch to this 12V, 5V 555 Relay timer.
    **** Free Course ***
    Arduino Step by Step Course (over 100 lectures) Starts here • Lesson 00 What is Ardu...
    The best thank you for me is to not to skip ads and Subscribe 🔔 to my channel, like 👍 the video It is greatly appreciated. 🔔 😊.
    I will reply to all Subscriber's 🔔 questions. So make sure to Subscribe.😊 .
    Jump to different section of video by clicking on the time:
    00:00 Start
    00:29 Introduction
    02:03 Capacitor for longer time
    03:02 Adding reset switch
    04:07 Wiring
    04:36 Demonstration
    Resources and datasheet for this video: robojax.com/L/?id=224
    Purchase 555 Relay Timer module (Affiliated stores)
    Amazon USA: amzn.to/37Jlcow
    Amazon Canada :amzn.to/34wkfxG
    Amazon Deutschland : amzn.to/2G7wqI4
    Amazon UK: amzn.to/2HDaC7t
    Amazon Italy: amzn.to/3jA8ZVe
    Amazon Spain: amzn.to/31JWIrm
    Tutorial by Ahmad Shamshiri form Canada
    ****************************
    Arduino Step by Step Course (over 100 lectures) Starts here • Lesson 00 What is Ardu...
    Learn Arduino in 30 Minutes (video): robojax.com/L/?id=135
    ****************************
    If you found this tutorial helpful, please support me so I can continue creating contents like this. Here is PayPal link paypal.me/robojaxTV
    Follow me on Facebook robojaxTV
    Follow me on Twitter: / robojaxtv
    Follow me on Instagram: / robojax
    Tutorial by Robojax.com
    Get other projects code and learn Arduino
    robojax.com/learn/arduino
    #robojax #robojax_timer
  • Věda a technologie

Komentáře • 128

  • @frankcaccamo3568
    @frankcaccamo3568 Před 3 lety +7

    I’m only going to say , how smart all you people are. I’m slowly learning and enjoying all this. Fantastic

    • @robojax
      @robojax  Před 3 lety +1

      Welcome to electronics. I am glad you liked it. Please browse my channel and you will be amazed. Please don’t forget to subscribe. I appreciate it.

  • @sorenweisshartmann
    @sorenweisshartmann Před 3 lety

    Thanks for an excellent video, well explained. :)

  • @user-vz4mr3iq9j
    @user-vz4mr3iq9j Před 6 měsíci

    😊 thank you for this video! Your the best!

  • @mrcountry
    @mrcountry Před rokem +2

    Thank you for your tutorial. I need the reset button. Two thumbs up 👍👍

  • @rafikulrahaman9321
    @rafikulrahaman9321 Před 3 lety +2

    Very nicely explain, thanks.

  • @rickneill6924
    @rickneill6924 Před 2 lety +2

    Thanks. I needed an external reset. You saved me a lot of time. 👍👍 ✔️✔️

  • @Kris0725PL
    @Kris0725PL Před 3 lety

    This is very good!

    • @robojax
      @robojax  Před 3 lety

      You are welcome. Please subscribe. I appreciate it and helps my channel grow. Thank you

  • @Electronzap
    @Electronzap Před 6 měsíci

    Clever.

  • @emiliojosedavidpardodiaz6562

    Excelente video,muchas gracias por agregar la traducción así puedo entenderlo en español, me suscribo de inmediato a tu canal tienes información muy valiosa, muchas gracias de nuevo!

    • @robojax
      @robojax  Před 3 lety

      Me alegra saber que el video y la traducción te resultaron útiles. Gracias por suscribirte. Mantenerse a salvo.

  • @ahmedqatar5944
    @ahmedqatar5944 Před rokem

    Hello brother, thank you for your effort. I want to use this circuit to turn on and off the parking lights in cars. How can it be used? Is another relay added or the same circuit used?

  • @nalindathushara3065
    @nalindathushara3065 Před 9 měsíci

    Can i use this timer for beam sensor,v for increase the alarm response time

  • @hefnijaber7088
    @hefnijaber7088 Před 6 měsíci

    Dear Mr. Ahmed it is great explanation as per my understanding this time delay for circuit off ( ie circuit switch off after predetermined time ) I do not no if can modify such circuit to be delay for circuit on ( ie circuit switch on after predetermined time ) best wishing and regards

  • @ranaqamarali109
    @ranaqamarali109 Před 8 měsíci

    Sir you are best teacher

    • @robojax
      @robojax  Před 7 měsíci

      I am glad to be helpful.

  • @akutenshi7023
    @akutenshi7023 Před 4 lety

    Ohh cool

  • @MechanicForGMCCars
    @MechanicForGMCCars Před rokem

    Sir I hoppe you can answer my question I like to use hv ceramic capacitors with my hei ignition system series of capacitors soldered together and I place it any where on my e core ignition coil mostly coil + side the other side I ground to chassys or wia some trip switch .
    Now the problem acured my car is 80s Opel it has the Delco 12si alternator I think its A circuet alternatir I use only pin 1 with light bulb the other pin 2 isnt used I do not have any diodes in my car only bulb when ever I use those multipel 3 kw capacitors in seies my alternator starting charge gets displaced so my alternator constantly back feading true the bulb unless I give it more revs and the alternator starts charging my baterry and the alternator light goes off but If I run on normal idel speed the bulb turns on again .
    So can you tell my please what thoes capacitors have to do with the alternators voltage regulator amd how can I counter this strange effect?
    How much I culd understand inside my alternator regulator I found miniature ic chip and 2 small capacitors how much I culd understand the ic chip is also baterry negative voltage potential controled some sort of?
    So how to chuse capacitor or value to counter this effects?
    I have lot capacitirs resistors and 500k potenciometer also have insulated alternator voltage regulator screws but dont know how its calculated out come that my alternator charges in what rpm ranges.
    So I hoppe you understand my question .
    So Im not shure what to use honestly resistor/capacitor box ,cloosed loop voltage regulator Im still cinde of woried to over charge my baterry

  • @electronic7979
    @electronic7979 Před 4 lety +1

    👏👏👏

  • @ABUHUZAIFA1979
    @ABUHUZAIFA1979 Před rokem

    Alsalam o Alikum
    I want to convert this module to 5v ,
    And use 3-32 v npn sensor to restart timer,
    Input power supply regular on ,
    Bro tell me how can I do ,
    JazakAllah

  • @electronicsandsweets5424

    Good

  • @Shawbonez
    @Shawbonez Před 4 lety

    Hi! Great video! I will add the reset button, but how many amps will relay handle for 12v? I want to use as a kill switch in my vehicle to turn off 10A starter fuse. Tnanks!

    • @robojax
      @robojax  Před 4 lety

      Hi, thanks. it seems you have directly jump to this video while I mentioned that yo have to watch the introduction here czcams.com/video/RjWW4nbUyio/video.html

    • @anthonysleight9244
      @anthonysleight9244 Před 3 lety +1

      Use this relay to operate auto relay

    • @Shawbonez
      @Shawbonez Před 3 lety

      @@anthonysleight9244 Thank you!

  • @lllAstridddlll
    @lllAstridddlll Před 3 lety +1

    👍👍il serait intéressant de lui ajouter une extinction automatique du module une fois le décompte fini 👍

    • @robojax
      @robojax  Před 3 lety

      possible. but it would need another switch to turn it ON again.

  • @vaskovaskez2053
    @vaskovaskez2053 Před 2 lety +1

    Hi, excelente explain, thanks ... I have same module but as delay on mode ... Can you explain how to change to delay off mode

    • @robojax
      @robojax  Před 2 lety

      For the load just connect it to the middle and other connector of the relay and the operation will be reversed. Instead of On it will OFF

    • @vaskovaskez2053
      @vaskovaskez2053 Před 2 lety

      @@robojax Thanks for quick response!
      Obviously I was not explained right, sorry for my english...
      My module work opposite than yours. When I turn power on after couple of seconds (after desired time delay) the relay turn on and green light is on unlimited time. On your video it is opposite, after turn power on or push the swich you have desired time delay for relay and green light turned on after that it turned off.
      Can I do something to change operation mode as on your module?

  • @taniorganik4702
    @taniorganik4702 Před 2 lety

    Thks for subscribe

  • @gerryjamieson1861
    @gerryjamieson1861 Před 3 lety

    Hello. I'm not sure if you can suggest a fix for my situation. I have a 2005 Dodge Grand Caravan. The rear intermittent wiper motor, when turned on pulses the wiper every 6 seconds. This is very annoying. Can what you are showing help me to control an increase in time between impulses. Ideally I'd like the rear wiper to pulse on between 30 seconds and a minute. Thank you

    • @robojax
      @robojax  Před 3 lety

      Hello, you can't change that timer. but you can change the continuous operation by putting this relay on the path of motor wiper.

  • @hefnijaber7088
    @hefnijaber7088 Před 6 měsíci

    Kindly I request you to provide sketch for this best regards

  • @cobraAH1
    @cobraAH1 Před 2 lety

    hi, how about adding proximity sensor switch?

    • @robojax
      @robojax  Před 2 lety

      Hi, use any switch that creat the same high or low state.

  • @patrickb3469
    @patrickb3469 Před 3 lety +3

    Hi, I followed the wiring for the switch minus the additional capacitor but not resetting. Mine module seems to work opposite yours. Only one led on until it reaches time then both on, while yours starts with both on and turns off. What's going on there?

    • @robojax
      @robojax  Před 3 lety +1

      then either your module is different or you've connected the load wires different. I am not sure.

    • @shubhamjain7036
      @shubhamjain7036 Před 3 lety

      I have same module.
      Our modules are different

  • @Rodatum
    @Rodatum Před 2 měsíci

    I'd like to make a delayed start signal for a project but I can't wrap my brain around these timers offered on Amazon.
    I have an inverter (Schneider Electric XW+) that will use a battery bank to power my critical loads. It can also get power from a generator that it will start when told to do so.
    I want to connect a 12vDC relay to a power adapter connected to a grid outlet, that is, not a critical load outlet. When the power goes out the relay will switch and the normally open connection will close. That's the trigger that the grid power is out.
    That trigger needs to delay start the generator after grid is down for 15 minutes by momentarily closing a connection on the inverter. However if the grid comes back up before the 15 minutes then everything is canceled, that is, I don't want to signal the inverter to start the generator.
    Another delayed timer relay is to stop the generator after the grid is up for 15 minutes. If it comes up and then down again before the 15 minutes, then nothing happens. But if the grid stays up for 15 minutes, (12vDC relay connected to grid power adapter is on), then a different connection on the inverter is momentarily made signaling it to stop the generator and return to using grid power for the critical loads.
    Any thoughts, comments, ideas, etc. will be appreciated!
    Thank you

  • @narendrabhatia6140
    @narendrabhatia6140 Před 11 měsíci +1

    V NICE EXPLAIN 👍👍👍🙏🙏

  • @jan5504
    @jan5504 Před rokem

    why my time delay won't work if the electricity gets cut out and immediately return, I want to use it as a surge protector but with this it removes it's purpose...

  • @Bernhard_V
    @Bernhard_V Před 4 lety

    Hi Robojax, is it possible to make a hack for battery-powered lamps?
    The timer module is not connected to the voltage. Only when the push button is pressed, the module is supplied with voltage via the relay and after the time, everything is disconnected again. So the lamp and the module do not need any power. Is that possible?

    • @robojax
      @robojax  Před 4 lety

      Hi, we have control system and the lamp. Relay and controller must have power available to them. They simply disconnect the lamp.

  • @manojvc6356
    @manojvc6356 Před 4 lety

    😍

  • @obedobi5554
    @obedobi5554 Před 3 lety

    Hi,
    Is it possible i can use a limit switch instead of reset switch. And as soon as the limit switch is pressed, the power is cut off, and after 2 seconds the power starts again irrespective of limit switch is kept pressed or depressed.
    Thanks

    • @robojax
      @robojax  Před 3 lety

      Hi, this can't do anything else. see other modules czcams.com/users/RobojaxTVsearch?query=Timer or Learn Arduino in 30 Minutes (video): robojax.com/L/?id=135

  • @taniorganik4702
    @taniorganik4702 Před 2 lety

    Assalamualaikum i am from Indonesia

    • @robojax
      @robojax  Před 2 lety

      walaikum salam Tani from Indonisia.

  • @GoodMods
    @GoodMods Před 3 lety

    Hi Robojax, I need your knowledge... I want to have a module which I can connect to my computer and adjust it on there, and set the time between 0-1 second, so i want microseconds... Or adjust the microsettings with my phone, what module do I need? thanks

    • @robojax
      @robojax  Před 3 lety

      hi, you need Arduino with relay. I have tones of videos on that.

    • @GoodMods
      @GoodMods Před 3 lety

      @@robojax also microseconds? You have any links to one of them?

    • @robojax
      @robojax  Před 3 lety

      You were talking about relay which can never be turned on of at microseconds. Relay is very slow like I.2 seconds

    • @GoodMods
      @GoodMods Před 3 lety

      @@robojax i need something which is very fast, like 0.1 seconds or 0.2 seconds

    • @robojax
      @robojax  Před 3 lety

      relay is not good option for that. relay is mechanical switch and I am not sure if it responds at 0.1s very well.. if you control DC load you can use mosfet and if you control AC load then use TRIAC to turn ON or oFF quickly.

  • @omarhamada221
    @omarhamada221 Před měsícem

    What capacitor would it take to increase time half an hour?

    • @robojax
      @robojax  Před měsícem

      It is R times C but I did not try it. So experiment with different size. Once you find time for a certain size then you know the what size to capacitors to use. Is simply try sizes.

  • @marisamorena8452
    @marisamorena8452 Před 3 lety

    I people I need some help 😢
    I have that module and I think they never work (relay and green led) try same circuit 12v for lamp.
    how do I fix it and make it loop 10sec on 10sec off ?

    • @robojax
      @robojax  Před 3 lety

      Can’t do loop see this czcams.com/video/81XzLwt3dqo/video.html

  • @ahmedeskafi8670
    @ahmedeskafi8670 Před 3 lety

    if i turn off the main power and turn it on again the relay will start working directly whit out press the button right ? than how i make relay run by just pressing the button even if i restart the main power ?

    • @robojax
      @robojax  Před 3 lety +1

      yes. Use Arduino. forget about this czcams.com/video/6DGQhQgr7Ak/video.html or this czcams.com/video/BhEIFzFSMuE/video.html

    • @ahmedeskafi8670
      @ahmedeskafi8670 Před 3 lety

      @@robojax thanks for reply 😊🌹

  • @terryroe2023
    @terryroe2023 Před 3 lety

    How about adding a PIR sensor to activate the relay? Can be done?

    • @robojax
      @robojax  Před 3 lety +1

      Hello, yes watch this video czcams.com/video/mZCJNOf69JI/video.html and instead of Arduino, connect it to this module. I believe it should work.

    • @terryroe2023
      @terryroe2023 Před 3 lety

      @@robojax I shall watch right now

    • @terryroe2023
      @terryroe2023 Před 3 lety

      @@robojax maybe wrong video, it's about arduino connection

    • @robojax
      @robojax  Před 3 lety

      that is correct video. you learn how the motion sensor works. the sensor simply outputs voltage and you connect it to this timer instead of Arduino. if trigger level is the opposite of what you expect, then make circuit like this snipboard.io/vERWPt.jpg to change HIGH level to LOW or in reverse.

  • @HardcoreEDM
    @HardcoreEDM Před 2 měsíci

    Correct me if i am wrong, you increase the charge capacity by parallel capacitor, so it will take longer time to charge the capacitor?

    • @robojax
      @robojax  Před 2 měsíci

      the larger the capacitor, the longer the time that holds. Yes.

    • @HardcoreEDM
      @HardcoreEDM Před měsícem

      @@robojax Something wrong, the relay went on and off very repeatedly, sometime it's duration became shorter, seem like not enough current.

  • @GerryJ08
    @GerryJ08 Před 3 lety

    Can you please explain what you mean. Thanks

    • @robojax
      @robojax  Před 3 lety

      First of all you are watch the wrong video. Please watch this video czcams.com/video/RjWW4nbUyio/video.html and instead of bulb shown in the video, connect the positive wire going to the motor of your wiper. this will work when you set the wiper in continuous mode and this module will intervene and turn ON or OFF at interval required. I am sorry I can't explained better than this. See also this image snipboard.io/AHhRpV.jpg

  • @user-vs2yu4cu5v
    @user-vs2yu4cu5v Před 26 dny

    Hello sir, nice work for time increasing, but I want some more, I have a request to make video about how to convert this (off delay timer relay) to (on delay timer relay) that actual gives output after the time ends.

    • @robojax
      @robojax  Před 26 dny

      Relay has 3 connectors . Keep the middle wire connected. Move the second wire to the 3rd relay connector

    • @user-vs2yu4cu5v
      @user-vs2yu4cu5v Před 26 dny

      @@robojax Actually I want to change the output to open after delay( not the NO and NC of the circuit) and thanks sir for faster reply, you are very kind, who replies on a video published 3 years ago

  • @hefnijaber7088
    @hefnijaber7088 Před 6 měsíci

    Dear Mr. Ahmed please provide circuit diagram for this module best regards

    • @robojax
      @robojax  Před 6 měsíci

      Hi, as simple search for "555 timer circuit diagram" showed this www.circuits-diy.com/time-delay-relay-using-555-timer-ic/

  • @thanhtrung.productions
    @thanhtrung.productions Před 3 měsíci

    How to do it: when the first trigger signal causes the relay to close, if the waiting time has not expired, if we add another signal, the module will only reset the time without the relay opening. Until the last signal's waiting time expires, the relay will open.

    • @robojax
      @robojax  Před 3 měsíci +1

      Hi, may be you need a device like this Home Automation: How to use 7 Program 0.1s to 9999 minutes Relay Timer XY-LJ02
      czcams.com/video/s4oNCpH_I0E/video.html and I have more videos on different modules, just search

  • @TheTtreasure
    @TheTtreasure Před 2 lety

    Hi, how are you connecting the push button switch to the circuit??

    • @robojax
      @robojax  Před 2 lety

      Hi, it is shown in video and that’s why I made this video

    • @TheTtreasure
      @TheTtreasure Před 2 lety

      @@robojax OK, thanks, the reset switch is the same energizing switch, right?

    • @robojax
      @robojax  Před 2 lety +1

      we have one switch and whatever you call it.

    • @TheTtreasure
      @TheTtreasure Před 2 lety

      Thanks man

  • @wootdeco
    @wootdeco Před 2 lety +1

    It seems that there are two versions of this module. One that is ON and then it shuts OFF after timer and one that is OFF and turns ON after timer. On the first video you have second one and on this video you have first version. It's strange that there is second version since then relay is on all the time and you still have NC and NO open connections. Anway since this video i managed to rewire mine to put capacitor in place of potentiometer and potentimeter in place of capacitor.

    • @cdrive5757
      @cdrive5757 Před 2 lety

      Robojax should pin your comments as the top comment. From what I've read in these comments you're the only viewer that understands how this chip works. Including Robojax. Sadly, it's buried down deep in replies. You're absolutely correct in your assessment of this board. The logic as it configured is ass backwards. I've worked with the 555 for over 49 years and have never seen one wired like this one. It's absurd to have a board that spends 60 seconds with the relay de-energized while the rest of the 24 hour day the relay is energized and the board is powered on! WTF? Surfing through the data sheets I think anyone would be hard pressed to find Rt tied to GND and Ct tied to Vcc! It's simply unorthodox and inefficient. My 555 project is intended for a self cleaning (60 sec) filter cleaning cycle for my shop vac. Note: For fast recovery (re -trigger) add a reversed biased Diode across 'Rt' timing resistor. It speeds up discharge of the timing cap 'Ct'.
      Wakodahatchee Chris

  • @griffmoses8043
    @griffmoses8043 Před 2 lety

    I asked for help about why the push button reset does work. It is connected just as you describe in this video but it will not reset. Please help!!

    • @robojax
      @robojax  Před 2 lety

      It must work if you do it properly.

  • @thinkingpanot5283
    @thinkingpanot5283 Před 2 lety

    What will happen if i press and hold the reset button? Is the time will not run?

    • @robojax
      @robojax  Před 2 lety

      It will be on . I believe I have shown and pressed it. When you release the time count down starts

  • @kamleshpatel2684
    @kamleshpatel2684 Před 2 lety

    I have added a capacitor so IC is heating what is problem& solution

    • @robojax
      @robojax  Před 2 lety

      capacitor is should not do anything. you must have connecting the + and - in reverse. Capacitor should explode if you connect it in reverse.

    • @kamleshpatel2684
      @kamleshpatel2684 Před 2 lety

      I heve using 470 uf/35 v capacitr with polarity pl. Solution

  • @shubhamjain7036
    @shubhamjain7036 Před 3 lety

    Sir
    May I get circuit diagram?

  • @rashidnoor5477
    @rashidnoor5477 Před 2 lety

    I dont understand on fixing reset switch please explain again

    • @robojax
      @robojax  Před 2 lety

      It is done. Play it 2,3, or 4 times

  • @riyagupta-ob3gh
    @riyagupta-ob3gh Před 7 měsíci

    1000uf 50v and 1m after remove trimpot increase 10min

  • @sorenweisshartmann
    @sorenweisshartmann Před 3 lety

    How do you increase the time to 60 seconds? Thanks

    • @robojax
      @robojax  Před 3 lety

      That is exactly why I made the video to tell

    • @sorenweisshartmann
      @sorenweisshartmann Před 3 lety

      @@robojax With 220 it goes to about 40 second. What would.it take to go to 60 seconds?

    • @robojax
      @robojax  Před 3 lety

      I did not calculate it. just experiment. the capacitor size is unknown.

    • @omarhamada221
      @omarhamada221 Před měsícem

      Please did you knew how to do this

    • @omarhamada221
      @omarhamada221 Před měsícem

      ​@@sorenweisshartmannPlease did you knew how to do this

  • @lordrahulcool
    @lordrahulcool Před rokem

    Can i make it 2 hours???

    • @robojax
      @robojax  Před rokem

      Anything you like. Just add larger capacitor

  • @shubhamjain7036
    @shubhamjain7036 Před 3 lety

    Where is trigger pin connected?

    • @robojax
      @robojax  Před 3 lety +1

      You have skipped the video. Please watch fully

    • @shubhamjain7036
      @shubhamjain7036 Před 3 lety

      @@robojax extremely sorry sir
      Video was very helpful

  • @jonalynrapsing410
    @jonalynrapsing410 Před rokem

    I try it.but push button is not working.

    • @robojax
      @robojax  Před rokem

      You just have done something wrong. Check again

  • @shubhamjain7036
    @shubhamjain7036 Před 3 lety

    Sir
    Where is pin 7 connected?

    • @robojax
      @robojax  Před 3 lety

      I don’t have the board , just look at it from both side and use multimeter to figure it out. Also look at 555 timer datasheet you easy read it.

    • @rickneill6924
      @rickneill6924 Před 2 lety

      In this use of the NE555, pin 7 is not used. It is the discharge pin for a timing capacitor. In an astable multivibrator circuit it would be used to discharge the timing capacitor to continually repeat the charging cycle. In this case the NE555 is used to create a monostable multivibrator (Also called a "one-shot") so pin 7 is simply not connected to anything.

  • @sayedalibahrain5592
    @sayedalibahrain5592 Před rokem

    Rest not working

    • @robojax
      @robojax  Před rokem

      Working . You are not doing right . I have shown on video . Watch again