diy super dry air on the cheap.

Sdílet
Vložit
  • čas přidán 14. 01. 2021
  • one year review on my air compressor drying system
    the original build video link
    • How to build a compres...
    link to the parts used
    amzn.to/38KHZAs
    amzn.to/3ssGTRC
    amzn.to/39Hqh06
    amzn.to/3idSb7G
    amzn.to/35KfHnC
    amzn.to/3ifM6aE

Komentáře • 40

  • @jsnyara
    @jsnyara Před 3 lety +21

    Nobody has corrected you on how to say it but I must! Desiccant (Dess-i-kent). Thanks for the follow up video! Really appreciate it. I planned on using coiled copper line for my aftercooler (between the compressor and tank) but you showed me those transmission coolers can handle the pressure just fine. Thanks!

  • @scottjames5385
    @scottjames5385 Před 8 dny

    Interesting video. Clearly successful which is great. But I wonder if a little overcomplicated? For instance, why use desiccant chambers at the bottom of the loops when you could simply have a 150mm down stand on each loop with a purge valve? You know there will be condensed water there. You don’t need desiccant for condensed water. Desiccant is useful to eliminate vapour. Another example is the cooler before the compressor tank. If the water condenses in the tank, then the tank is essentially a condenser. That moisture is no longer in your air, although it will increase the humidity of the air in the tank. But that’s what your drier loops are for! Just empty the compressor tank daily. 👍🙂

  • @randywheeler3236
    @randywheeler3236 Před 3 lety +1

    Nice system!! Now I know what I am going to do, Thanks for the education.

  • @samthompson1270
    @samthompson1270 Před 3 lety +1

    Good information John and another great video.

  • @jakemodrell3821
    @jakemodrell3821 Před 3 lety +1

    Great system. Another good video. Keep it up.

  • @daviddaniels3591
    @daviddaniels3591 Před rokem +1

    Thanks for explaining your build. Hadn’t researched my water problem yet and now I see what causes it. Peace ✌️

  • @DustinApple
    @DustinApple Před 3 lety +5

    Built a dryer with a large oil cooler, 12v adapter on a electric radiator fan and a single water trap. Only spent like $150 on everything. Took 300⁰ head temps down to 5⁰ above outside temperature keeping my tanks dry. At the chuck I used the dry crystal trap but after a year its still blue.

    • @bholarizwan73
      @bholarizwan73 Před rokem +1

      Hi. Can you share the details of your setup

  • @michaelbyrnes7944
    @michaelbyrnes7944 Před 5 měsíci +1

    That’s awesome air man great set up

  • @chriszbodula1894
    @chriszbodula1894 Před měsícem

    I like the idea of cooling the air before it goes into the tank, very smart. I plan on experimenting with a desiccant filter on the air intake to stop the moisture before it goes into the pump as well as your radiator cooling system. Will have the stock air filter first, then the desiccant filter and into the compressor. Will try that first before adding the radiator

  • @1D10CRACY
    @1D10CRACY Před 3 lety +2

    I second the oil cooler! Did that to mine a while back with the water separator in line before going into the tank and as you said, its well worth the investment.

  • @PaulThomas-qo9vy
    @PaulThomas-qo9vy Před rokem +1

    Nice copper work & experimentation to improve your system, Kudos! A few suggestion: #1)Add an electric fan to the oil cooler. The logic is: A 1 inch + gap exists between the flywheel/fan blades & the cage mounted oil cooler & most of the air just goes anound the cooler because the fins resist air flow by design. With a fan pushing air thru the cooler, the cooling efficiency goes up + the extra airflow will cool the pump fins, reducing air discharge temp., further adding to the efficiency. Then flow the comp. air thru the water trap on the tank. The final solution to stop all water in the tank is: #2)Flow the air from the water trap into a Schedule 40 2" dia. × 36" long galvanized pipe, loosely stuffed with stainless steel wool scrub pads. Vertically mount the 2" pipe + a top bell reducer for air inlet & a bottom 2" "T" with bottom drain valve & side air exit to go to the tank inlet/check valve. This 2" vertical pipe is the rest of the magic formula. It provides reduced air velocity (more dwell time) to allow the remaining moisture to grab ahold of the stainless steel wool (coalescing) into droplets that fall into the drain valve area. Now you have air dry enough that No water will accumulate in the tank or lines. Use a desicant & then a particle filter combo At the Point of Use (taken from the wall mounted copper tube thingy because it is not necessary). About the up/down copper tube device: Have you ever seen an automobile cooling radiator made from copper tubes & No fins & No air flow? Or a modern car with solid wood wheels right? All these have been surpassed by surperior technology. For the ultimate engineer designed, hobby sized passive (No refrigerated driers), see Doug Kronemeyer's 3 part CZcams video series "DIY #9" where he presents, in Part 1, schematics & system design logic & knowledge. Part 2 is in his own shop, looking at each part of his sys. & how & why it works so efficiently. Alright, keep experimenting & learning every day! Peace, Paul from hot & super humid S. Central Tx.. P.S.A shoutout to Bud Stiner, THE Compressor Guru! He has many DIY tutorial repair & diagnostic videos (CZcams) & offers & ships parts, & local service/repair. Great guy!

    • @lynchcreekmuzzy5759
      @lynchcreekmuzzy5759 Před měsícem

      Thank You for the info!! ....Just watched the 3 part series by Doug and about to watch Stiner. Looks like i will be setting up my air dryer starting today....doing this for DIY auto painting in garage. This was a huge help!! 😁👍

  • @sloppydoggy9257
    @sloppydoggy9257 Před 4 měsíci +1

    Cooling the air back down to ambient before it goes into the tank is probably the best dollar per benefit possible in terms of getting water out of the air.

  • @craigwavra3495
    @craigwavra3495 Před 3 lety +1

    That’s what I like about you and your channel. You are always thinking about how to improve something.

  • @user-vc9jq4ws7k
    @user-vc9jq4ws7k Před 8 měsíci

    T job. Makes so much since

  • @twopassionsfishing386
    @twopassionsfishing386 Před 3 lety +1

    Great video friend, God bless your weekend

  • @arthurjackson
    @arthurjackson Před 11 měsíci +1

    Diekessent? Made me laugh out loud. 🤣🤣🤣 Great video though. I really like the radiator and will probably add one to my system. Makes me wonder why they aren’t sold as an option.

  • @chriszbodula1894
    @chriszbodula1894 Před měsícem

    Can you use a temp gun to get the temp on the pump side, then the output side of the radiator pipe after it’s been running for a good long time so it’s nice and hot. Curious to see the difference. My abrasive blasting system keeps getting clogged with moisture

  • @billabram8512
    @billabram8512 Před 2 měsíci +1

    Thank you for a great really informative video on cooling compressed air! It sounds like something I will do now that I have seen yours. 1 question I have is, How does the radiator cool the air without a fan on it? how does that work? do you need to run electricity for it?

    • @JDSOutdoors
      @JDSOutdoors  Před 2 měsíci

      Not at all the compressor runs the fan which pulls the air through the radiator. Works extremely well.

  • @benhightowerv
    @benhightowerv Před 3 lety +1

    I remember the system being upgraded on the wall, that tank mod though, that's ingenious. I need to do that.
    Can you do a video specifically on the trans radiator mod? Like how to run it, the pulley and fan, e.t.c?

    • @JDSOutdoors
      @JDSOutdoors  Před 3 lety +2

      I can make one but it's super easy. No modifications to the pully or fan at all. The trans cooler is literally zip tied to the fan shroud and plumbing ran from the pump, to the cooler, to the auto drop, then back to the tank.

    • @benhightowerv
      @benhightowerv Před 3 lety +1

      @@JDSOutdoors I kinda figured that's how it was but I wanted to be sure. That's awesome and definitely easily attainable

    • @JDSOutdoors
      @JDSOutdoors  Před 3 lety +2

      @@benhightowerv super easy and extremely effective for a cheap price tag. I have the parts I used linked below minus the plumbing which really needs to be purchased locally with the pieces brought in

  • @mrmotofy
    @mrmotofy Před rokem

    Probably cheaper and simpler precooler option is a 5gal bucket of water with a coil of copper pipe in it with an auto drain at the bottom that expels it occasionally.

  • @jimwright9500
    @jimwright9500 Před 2 lety +6

    Its' called DES-E-CANT.

    • @JDSOutdoors
      @JDSOutdoors  Před 2 lety +3

      Feel better?

    • @thardyryll
      @thardyryll Před rokem +2

      The high school graduates among us will feel better if he manages to pronounce it correctly.

    • @jhyland87
      @jhyland87 Před rokem

      God forbid he help you out by saying how to pronounce it properly.. lol.

  • @robbieodum9345
    @robbieodum9345 Před 3 měsíci

    My only question is, what are the ends you put on the copper pipe to screw in and feed to the transmission cooler, and how do you install them on the copper pipe? Trying to do a similar setup now for my air compressor for a blasting cabinet. Awesome video btw.

  • @mrmotofy
    @mrmotofy Před rokem +1

    The HF line drier is up to $550...no effort/maintenance except turn it on

    • @lynchcreekmuzzy5759
      @lynchcreekmuzzy5759 Před měsícem

      The HF reviews are kinda sketchy on that dryer...not sure it's worth the risk. It seems these diy systems are durable and very few things to go wrong, if at all.

  • @leonrodenburg1
    @leonrodenburg1 Před 7 měsíci +1

    Jo please can you send me a video how i can make that air cooler on your compressor please 😬

    • @JDSOutdoors
      @JDSOutdoors  Před 7 měsíci

      Unfortunately I can't but next time I build one I'll film it

  • @immanutt4442
    @immanutt4442 Před rokem

    wayment ... if I watch this video from 2 years ago about how this drying system has worked for past year ...

  • @icebluscorpion
    @icebluscorpion Před rokem

    That's sounds stupid to me. Why don't you put the cool air not through your drying system first before putting it in the tank? If your drying system is that good then you would get no condensation whatsoever in your tank in the first place, right?