HVAC Gas Valve Problems and Solutions

Sdílet
Vložit
  • čas přidán 15. 08. 2024
  • Join this channel to get access to perks:
    / @taddydigest
    Wanna Learn more about hvac?
    Check out my hvac tips for technicians playist.
    • HVAC Tips for Technicians
    Fieldpiece SC440 True RMS Clamp Meter
    amzn.to/3rdGZ0e
    Go check out Fieldpiece Products to learn more about there multimeter the SC440
    Fieldpiece Dual-Port Manometer - SDMN5
    amzn.to/3SNNLoS
    How to set gas pressure for 2 Stage Heat?
    Video Link
    • Setting the Gas Pressu...

Komentáře • 76

  • @takethe101totarzana4
    @takethe101totarzana4 Před rokem +1

    The Dumb and Dumber reference was awesome, Lloyd Christmas is somewhere smiling. Thanks for posting Tad, solid video.

  • @houdini-GT-R
    @houdini-GT-R Před rokem +3

    A whole lot of components that I'm not used to I start my new job doing service calls next week I've been doing new construction for the past 8 years I like your content easy to follow and thank you for doing them for us new Jack's doing service calls

    • @TaddyDigest
      @TaddyDigest  Před rokem +1

      Good luck my friend wishing you great success
      Thank you for watching

  • @rolytech212
    @rolytech212 Před 8 měsíci +2

    Before taken the inducer motor out I would loosen the burner manifold out. A lot easier

  • @emac1111
    @emac1111 Před rokem +2

    Great as always. Everything is useful in this video. Go on Tad👍Your subscriber from Azerbaijan

  • @roqueherrera8471
    @roqueherrera8471 Před rokem +1

    TAD U ARE THE BEST….. I LOVE YOUR VIDEOS . I going from install to tech and all this is GOLD to me.

  • @thaison773
    @thaison773 Před 9 měsíci +2

    Thanks for taking the time to make the video.
    I would like to know the size of that gas valve fitting to check for gas pressure with the manometer or if you can share a link of where to buy it.
    Thank you

    • @ikecrook1450
      @ikecrook1450 Před 7 měsíci

      Your menometer comes with the fittings

  • @jon3862
    @jon3862 Před rokem +2

    You are best of the best 👌 👍 HI from GOLSTAR healing and cooling

  • @fazesenso2864
    @fazesenso2864 Před rokem

    I’m in my 2nd semester of HVac school and ur videos are really good for learning new things

  • @ebuzek3648
    @ebuzek3648 Před 10 měsíci +3

    never adjust a used belt. always install a new belt and then adjust if needed. put a spare or two in a plastic bag.

    • @ikecrook1450
      @ikecrook1450 Před 7 měsíci +2

      I agree then you get the new one you have to re adjust it again

  • @elmerramirez1215
    @elmerramirez1215 Před rokem +1

    Good video man, I’m starting as comercial pm technician and really looking forward to moving up

  • @user-ql2bz8on7m
    @user-ql2bz8on7m Před 2 měsíci +1

    It was an awesome video thank you

  • @ikecrook1450
    @ikecrook1450 Před 7 měsíci +1

    You can't go off the 24 volt to the gas valve I have had them read 24 but had bad common on board if you have analog volt meter it will read 0

  • @miguelrojas3394
    @miguelrojas3394 Před rokem +1

    I really like the videos the way you explained and thanks for your hard work.

  • @Eddy63
    @Eddy63 Před rokem +1

    Good info Tad ... Thx for posting ...

  • @migueldominguez4311
    @migueldominguez4311 Před 8 měsíci +1

    Great video !
    I have a issue with a gas comercial heather that is used in drive tru canopy !
    And is not turn on
    What could b the issue
    The valve or the main gas ?

  • @steveomac5001
    @steveomac5001 Před rokem +1

    It’s looks exactly like a carrier rtu but it has yorks shitty controller. Crazy

  • @hoppychulo1015
    @hoppychulo1015 Před rokem +1

    Great video

  • @yodamanrulz176
    @yodamanrulz176 Před rokem +1

    Thank you Tod good information all around. However, being new to HVAC, I find it disconcerting when the teacher uses their elbows/fingers to point at something of importance. Please strive to be super clear by using a probe tip or chopstick to point and maintain the point for three or four seconds for a screenshot reference. Thank you.

  • @alexibonnet2634
    @alexibonnet2634 Před rokem +1

    Good video, thank you

  • @oscarestrada5509
    @oscarestrada5509 Před rokem +1

    Great video bro

  • @antonioquatela4364
    @antonioquatela4364 Před 6 měsíci +1

    Hello. great content. I Have a question … have you ever experienced a commercial customer call you with a complaint of natural gas odor inside a store? I’m checking these units up and down but am almost out of theories. Is there a premature opening of the gas valve or maybe an induction motor with a leak somewhere? Pretty windy on the roof maybe it needs a exhaust extension brought up higher.

    • @TaddyDigest
      @TaddyDigest  Před 6 měsíci

      could be a bad board or something like that where its sending power to gas valve and not igniting.
      or regulator vent is leaking

  • @imbobbymuddah
    @imbobbymuddah Před měsícem +1

    Can you use Teflon instead of thread sealant

  • @garypoplin4599
    @garypoplin4599 Před 9 měsíci +1

    Do you have a video on how to clock the meter on a unit like this?

  • @glennlockwood7608
    @glennlockwood7608 Před rokem +1

    Nice video. How did you manage to have a replacement valve on hand?

    • @TaddyDigest
      @TaddyDigest  Před rokem

      I did not I ordered it it came in in 2 days
      I am an hour and a 1/2 from Nashville to an hour
      2 hours from Memphis
      One hour from Jackson
      I have suppliers all over near me

  • @aarongray503
    @aarongray503 Před rokem +2

    Man that was a wealth of knowledge!! Thanks tad! What size of manometer fittings do you typically use? I'm in commercial hvac in Texas but still green.

    • @TaddyDigest
      @TaddyDigest  Před rokem

      Hey Aaron send me an email thank you so much for joining and being a member
      tadfuller1@gmail.com

    • @TaddyDigest
      @TaddyDigest  Před rokem

      Glad I could help

    • @ikecrook1450
      @ikecrook1450 Před 7 měsíci

      They are all standard simple barbed fitting works should come with manometer

  • @brandoncorrea511
    @brandoncorrea511 Před rokem +1

    Keep doing these vids. I like it 👍

  • @hectorgonzalez8185
    @hectorgonzalez8185 Před rokem +1

    Good video

    • @TaddyDigest
      @TaddyDigest  Před rokem +1

      Thanks Hector
      I have some guides I want
      To send you
      Please send me an email at tadfuller1@gmail.com

  • @stevencovington1776
    @stevencovington1776 Před rokem +1

    Hey great video, but did have one question, you normally check your sensor by ohms reading and not continuity?

    • @TaddyDigest
      @TaddyDigest  Před rokem

      Normally I check the resistance reading
      Continuity is also a good check

    • @srobeck77
      @srobeck77 Před rokem

      Its generally going to be an ohms reading. Continuity is generally for broken wires. Either way, its the same mode on your meter to look for low ohms or O.L.

    • @ikecrook1450
      @ikecrook1450 Před 7 měsíci

      It will work the same way I use continuity

  • @stevencovington1776
    @stevencovington1776 Před rokem +1

    which membership is with the private videos and support?

  • @roqueherrera8471
    @roqueherrera8471 Před rokem +1

    I would hate to ask but do u have any Carrier/Trane/Rheem unit trouble shoot

    • @TaddyDigest
      @TaddyDigest  Před rokem

      I'm not sure if I do or not
      I think I do but if I don't I'll have some soon

  • @paulrozinski1488
    @paulrozinski1488 Před rokem +1

    Why all the rust on the gas pipes and disconnect switches ?? What area of the US is this ??

    • @TaddyDigest
      @TaddyDigest  Před rokem

      Tennessee near Nashville

    • @srobeck77
      @srobeck77 Před rokem

      Pipes rust everywhere doesnt matter the location. Even indoors. In salty air, close by oceans, is where metal will rust much faster.

  • @Ray-wr2wr
    @Ray-wr2wr Před 7 měsíci +1

    hi what are they symptoms when dirty burners ?

    • @TaddyDigest
      @TaddyDigest  Před 7 měsíci +1

      flame will not spread across burners if dirty

    • @Ray-wr2wr
      @Ray-wr2wr Před 7 měsíci

      @@TaddyDigest thanks

    • @Ray-wr2wr
      @Ray-wr2wr Před 7 měsíci

      @@TaddyDigest what's causing mini explosions /bang on commercial RTU ? gas furnace

  • @sergioramirez9025
    @sergioramirez9025 Před rokem +1

    Hey tad quick question how did you know that sensor was supposed to be 10k ohm? I haven't diagnosed that sensor before but on the ODA and SAT MAT sensors RTA sensors etc how do you check those? Is that with a 10 k ohm chart? And has to match the same ambient temp outside???

  • @juliocastillo1988
    @juliocastillo1988 Před 7 měsíci +1

    👍👍

  • @marwinbrown5089
    @marwinbrown5089 Před 5 měsíci +1

    Awesome video, giveaway

  • @abdullah_q8171
    @abdullah_q8171 Před rokem +1

    Microchannel is Cheap coil .

    • @srobeck77
      @srobeck77 Před rokem +1

      I think they actually cost more and are have better efficiency. But on the other hand, they break easier and are harder to repair. We require them to have hail guards on the rooftops units in our facility.

  • @srobeck77
    @srobeck77 Před rokem +2

    Your pipe doping skills are lacking here. First, you gotta clean the old threads with a wire brush. Next, apply a thin coat (more is not better). Last, you have to make sure to not get any pipe dope on the end of the pipe (you definitely got a big gob on the end of the pipe) so that it doesn't go into the system and cause problems. A final recommendation is that cogged belts are superior to those straight, standard belts.

    • @TaddyDigest
      @TaddyDigest  Před rokem +1

      thanks for watching and for the great tips 😀 👍

    • @srobeck77
      @srobeck77 Před rokem +1

      @@TaddyDigest I hope that didnt come as me being a jerk. Its very hard to strike a balance between criticism and not coming off as being insulting or disrespectful. (The same problem happens with text messages too Ive found.) I did very much enjoy your video here and look forward to more.

    • @TaddyDigest
      @TaddyDigest  Před rokem

      Friends look out for each other friends say something when others say nothing.
      It's better to say something
      Iron sharpening Iron
      Thanks brother.

  • @mahabubulalamshusom6327
    @mahabubulalamshusom6327 Před 8 měsíci +1

    Big fan of your videos@Taddy_Digest

    • @TaddyDigest
      @TaddyDigest  Před 8 měsíci

      Thank you brother. I really appreciate your support and I appreciate you watch the videos