Webinar: Conext MPPT 80 600 Solar Charge Controller Installation and Programming Best Practices

Sdílet
Vložit
  • čas přidán 11. 07. 2024
  • Join Sandra Herrera for this technical webinar on Conext™ MPPT80 600 solar charge controllers. The MPPT 80 A 600 Vdc solar charge controller offers optimum system performance for DC coupled solar and storage installations, with easy, flexible installation of large PV arrays.
    In this webinar, you will learn the MPPT 80 600 charge controller’s functions, features as well as installation, programming best practices. Additionally, we will discuss NEC 2017 690.11, 690.12, and 690.15 and how it applies to this solar charge controller.
    ►Click here to learn more about what the MPPT 80 600 can do for you: solar.schneider-electric.com/...
    -------------------------------------------------------------------------
    ►Click here to subscribe to Schneider Electric Solar Business: czcams.com/users/Schneide...
    Connect with Schneider Electric:
    ►Solar Business Website: solar.schneider-electric.com
    ►Visit our blog: solar.schneider-electric.com/...
    ►Twitter: / sesolar
    ►LinkedIn: / se-solar
  • Věda a technologie

Komentáře • 33

  • @RR42636
    @RR42636 Před 3 lety +5

    Sandra is a fantastic instructor. I am sometimes skeptical of videos like these, because I've seen too many cases where the video focuses on flashy features and provides only a little useful advice. As soon as I heard here though, I knew it would be a legit vid. Thanks Sandra!

  • @runinguy
    @runinguy Před 2 lety

    Great lecture, thank you.

  • @TerraFirmaX
    @TerraFirmaX Před 3 lety

    Thank you, I learned a lot

  • @Impakzy
    @Impakzy Před 4 lety

    Hi! Good job. Waiting for your Webinar on Conext MPPT 60 150 too

  • @jasonwang2754
    @jasonwang2754 Před 4 lety +1

    Really good video, make it simple and clear enough. One question, where can I get the Modbus protocol for lithium battery integration?

  • @bartthatcher5799
    @bartthatcher5799 Před 3 lety

    Awesome description of this product!! Any chance can I use the "MPPT Disconnect RS" as a Combiner box? Currently setting up a plan using your Xantrex XW6048 Dual Inverter system along with Two MPPT 80-600 Charge Controller. Basically looking for combiner options as well and Rapid Shutoff would be ideal for our 32 panel Ground mount system. Any suggestions?

  • @albertrosa7767
    @albertrosa7767 Před 3 lety

    Hola gracias por su vídeos son muy buenos puedes hacer uno de context 4048 inverte como desactivar el cargador de baterias

  • @ericjones3697
    @ericjones3697 Před 3 lety

    Hi Sandra, thank you so much for the insight into how these work. I have a dual inverter/dual charge controller system using 2 of these MPPT 80 600 controllers, however, one of my inverters (the master) is no longer actually charging even though it still tells the slave inverter to and that one is working as expected. Is it possible that one of my charge controller fuses is blown? If so, what would be my procedure to test it? Thanks!!

  • @kosanrachid7417
    @kosanrachid7417 Před 3 lety

    Can you please explain the difference between Combox and SCP? And can I configure my SW inverter with one?

  • @KS_Realtor
    @KS_Realtor Před 3 lety

    At 18:40 you show a photo of three inverters and five charge controllers. I have two inverters and three controllers. Where can I find a video or documentation on how to wire such a system?

  • @jefflongino4999
    @jefflongino4999 Před rokem

    For the controls options, I would prefer the simple local control panel and NOT any iPhone/Cloud application. Is the locally attached non-internet control panel an option still today?

  • @joselmoralesrodriguez6890

    Buenas tarde Sandra por que no puedo ver sus otros video que estaban en español.

  • @fernandogonzalezcruz6204

    Saludos Sandra desde Puerto Rico. Desde hace tiempo he estado viendo tus video y los encuentro muy educativos. Me gustaria si es posible que hablaras un poco de qué parámetros hay que cambiar cuando se reemplazan las baterías del gel por baterías de litio. En mi caso luego de reemplazarlas estoy teniendo dificultades para que el inversor entre en modo de venta a la red. Ayer por ejemplo fue un dia donde pude exportar 22kw sin embargo hoy bajo similares condiciones del clima no ha exportado nada. Mi sistema consiste en un xw 6848+, 2 mppt-60-150, 24 paneles de 280w y 2 baterias fortress lfp 10kwh

    • @SESolar
      @SESolar  Před 3 lety

      Para los parámetros de las baterías, siempre recomendamos seguir las instrucciones del fabricante.

  • @javierrivera9835
    @javierrivera9835 Před 4 lety

    Hello.. I recently install one off those chargers with one XW+ 6848 and the charger is giving me a W55 code heat sink temperature error. I also notice the top fans did not come on...any help will be appreciated. Thanks

  • @josesortiz8281
    @josesortiz8281 Před 3 lety

    Buenos dias sandra necesito saber como le doy reset al mppt 80 150

  • @nicholasgrammatico403

    The 80 600 mppt handles 4800 in from pv , the xw pro handles 8500 pv in. Does this mean I need 2 80 600 mppt s’?

  • @earlwilliams3772
    @earlwilliams3772 Před 2 lety

    my assist circuit from grid is showing voltage but no watts on the monitor

  • @pravindesai3186
    @pravindesai3186 Před 4 lety

    Hi Sandra I have just acquired 3x8548xw+ and 3 x 80/600 mppt . I am going to connect 2 of 48v/200 ah batteries i want to connect 1 on each phase . My question is can I connect all the batteries to all sets .

    • @Off-Grid
      @Off-Grid Před 3 lety

      Check out our channel where I install a 15.36Kw Multi Inverter and Charge Controller Schneider System.

  • @godwinwonder2622
    @godwinwonder2622 Před 3 lety

    Hi! Will this charge my 220v battery bank?

    • @ericbentsen1597
      @ericbentsen1597 Před 2 lety

      HVMPPT models only charge 24V and 48V battery banks.

  • @SpencerLAPower
    @SpencerLAPower Před 2 lety

    What happened to Sandra's Channel everything is going

  • @edwinrosado3886
    @edwinrosado3886 Před 3 lety

    Como lo veo en español?

  • @JohnSmith-lv8xk
    @JohnSmith-lv8xk Před 3 lety

    Wouldn't it be more efficient to bring the PV 500v onto the inverter's DC bus ? Rather than converting it to 48v and back again ?

    • @billjohnson3344
      @billjohnson3344 Před 3 lety

      It would. But you still need the 48VDC to 240/120VAC conversion aspect in the inverter for when there is no solar production (nightime).

    • @JohnSmith-lv8xk
      @JohnSmith-lv8xk Před 3 lety

      @@billjohnson3344
      Well of course but if there is sun and a load you wouldn't be stepping it down and back up again, all other conditions would remain the same.

    • @billjohnson3344
      @billjohnson3344 Před 3 lety

      @@JohnSmith-lv8xk Yes, I agree. But the Schneider concept is very modular and supports various setups - so there is some inefficiency and redundancy to support that. For example, the inverter can be used without solar at all and only for battery backup - hence the need to have the step-up (and no need at all for solar DC in that case). But, because of that flexibility, you end up with needing two things to charge the battery - both the charge controller (from solar) and the hybrid inverter (from grid). A compromise they chose for the system flexibility. Some definite design optimization could have been done if supporting only specific use-cases.

    • @boblatkey7160
      @boblatkey7160 Před rokem

      Well the inverter does not have a 500 V DC bus!

  • @ParveenKumar-oc1yg
    @ParveenKumar-oc1yg Před 2 lety

    What is charge controller price

    • @SESolar
      @SESolar  Před 2 lety

      Hi Parveen, Could you please fill out this form so that our sales agent could assist you? solar.schneider-electric.com/purchase-products/

  • @FMercuryEA
    @FMercuryEA Před 3 lety

    The cost of this controller is not worth investing in it. I would better buy solar panels equal to it's power rating complete with a pwm charge controller.
    What happened to cost benefit analysis ? The cost per watt of pv from china isn't worth investing in that controller.

    • @unionse7en
      @unionse7en Před 2 lety

      Can the cheap inverters handle 600v input at high amps and are they UL listed to pass inspections?